HomeMy WebLinkAboutPlansGodwin Engineering andDesign, LLC8378 Foxtail LoopPensacola, FL 32526D. Chad Godwin, PEChad@godwineng.comR-1# Modules (19)Pitch: 24°Azimuth: 269°R-2# Modules (8)Pitch: 24°Azimuth: 179°5'-6"3'-3"FRONTOFHOUSER-1R-22/2/2021GM..605 W Lumsden Rd,Brandon, FL 33511855-577-79991st Responder Accessminimum of 36" unobstructed as perSection R324 of the 2018 IRCCustomer Info:S-1Date:Drawn by:Revised by:Rev #: 00Rev Date:Page:Represents all Fire Clearanceincluding Alternative methodsUtility Meter2020 FL Residential Code & FBC, 7th Edition (2018 International Residential Code) - 2nd Printingmodified by the FL Building Standards , 2018 International Energy Conservation Code,County of Saint Lucie Code, 2017 National Electric Code.LegendFirst responder accessSheet IndexS-1 Cover Sheet / Site PlanS-2 DetailE-1 One - LineS-1A Mounting PlanUtility MeterPV DisconnectVent PipeChimneySatelliteNInverter Type:PV Panel:Racking:Total Wattage:Roof Type:Wind Load:Fastener Type:SolarEdge SE7600H-US(27) Aptos DNA-120-MF23-330WIron Ridge8,910WComposition Shingles20 to 27 DegUse 5/16" Dia 4" LagsFRONTOFHOUSELayout Subject to Change Based on Site ConditionsMeets All Editions of Florida Fire Prevention Code 6th EditionCompass for AerialSystem meets the requirements of NFPA 70th Edition, Chapter 11.12Install will be done to Manufacturer SpecSolarEdge Inverter-COGEN DisconnectLocated adjacent toUtility meter-SE7600H-USInverterGeneral Notes:-SolarEdge SE7600H-US Inverterlocated near utility meter-SolarEdge P340 Optimizers are located on roof behind each module.-First responder access maintained andfrom adjacent roof.-Wire run from array to connection is 60 feet.Michael Knowlton5207 Indian Bend Ln.Fort Pierce, FL34951Ground Access Point2' Access PathwayGround Access PointGround Access PointGround Access Point3' Access PathwayDonnie C Godwin2021.02. 04 15:00:25'00'06-
Godwin Engineering andDesign, LLC8378 Foxtail LoopPensacola, FL 32526D. Chad Godwin, PEChad@godwineng.com2/2/2021GM..605 W Lumsden Rd,Brandon, FL 33511855-577-7999Designed as per ASCE7-16Modules mounted flush to roofno higher than 6" above surface.Customer Info:S-2Date:Drawn by:Revised by:Rev #: 00Rev Date:Page:Inverter Type:PV Panel:Racking:Total Wattage:Roof Type:Wind Load:Fastener Type:SolarEdge SE7600H-US(27) Aptos DNA-120-MF23-330WIron Ridge8,910WComposition Shingles20 to 27 DegUse 5/16" Dia 4" LagsInstall will be done to Manufacturer SpecMichael Knowlton5207 Indian Bend Ln.Fort Pierce, FL34951Ironridge XR-10Roof SectionPitchRoof Rafter and Spacing OverhangNotes:R1-R25/122"x4" @ 24 O.C.12"TrussGeneral Notes:- Flashlocs are secured to roof rafters. @ 48" O.C. in Zone 1, @ 24" O.C in Zone 2e, @ 24" O.C. in Zone 2r, @ 24" O.C in Zone 3using 5/16" x 4" stainless steel Lag bolts.- Subject roof has One layer.- All penetrations are sealed and flashed.Donnie C Godwin 2021.02.04'00'06- 15:01:49
Godwin Engineering andDesign, LLC8378 Foxtail LoopPensacola, FL 32526D. Chad Godwin, PEChad@godwineng.com2/2/2021GM..605 W Lumsden Rd,Brandon, FL 33511855-577-7999In Case of Emergency CallACDC Solar LLCat 855-577-7999Customer Info:SolarEdge InverterSE7600H-USw/ Integrated Disconnect Equipment listPV:(27) Aptos DNA-120-MF23-330W(27) SolarEdge Power Optimizer P340(1) string of (14)(1) string of (13)Inverter:(1) SolarEdge SE7600H-USSolarEdge AC/DC Safety SwitchAC Disconnect:60A DisconnectAll wiring to meet the 2017 NEC and2015 Energy CodeSoladeckTypE-1Date:Drawn by:Revised by:Rev #: 00Rev Date:Page: Power OptimizerMeterAC Distribution Panel or Sub PanelLine Side Tap60A Service RatedFused DisconnectNeutral to Ground BondAC Disconnect40A Fuse #8 AWG THWN(1) Line 1(1) Line 2(1) Neutral #8 (1) EGCin @ least 3/4" Conduit Typically #6 AWG THWN(1) Line 1(1) Line 2(1) Neutralin 3/4" Conduit Typically(1)#8 AWG EGC & GECRefer to NEC 312.8 forConditions on taps in switchand over current devicesEnclosures.If the conditions are notmet a tap box willneed to be installed.Main Distribution Panel200A MainManual DisconnetOptional Line side connection(when available) Per 705.12(A)PHOTOVOLTAIC SYSTEMEQUIPPED WITHRAPID SHUTDOWNInstall will be done to Manufacturer SpecWARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATED ALLNORMALLY GROUNDEDCONDUCTORS MAY BE UNGROUNDEDAND ENERGIZEDApply to InverterWARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH THE LINE ANDLOAD SIDES MAY BE ENERGIZED INTHE OPEN POSITIONApply to DisconnectsWARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM AREUNGROUNDED AND MAY BEENERGIZEDApply to each J box, combinerbox, disconnect,and device whereenergized, ungrounded circuitsmaybe exposed during service.WARNING: PHOTOVOLTAICPOWER SOURCEApply to DisconnectsPHOTOVOLTAIC SYSTEM DC DISCONNECTMAX POINT CURRENT: 22.28 AMAX POWER POINT VOLTAGE: 400 VDCMAX SYSTEM VOLTAGE: 480 DCMAX CIRCUIT CURRENT: 15 AApply to DCdisconnect/inverterWARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRID AND PVSOLAR ELECTRIC SYSTEMApply to MSPPHOTOVOLTAIC SYSTEMEQUIPPED WITHRAPID SHUTDOWNLABEL PER NEC 690.56(C)-PROVIDE AT NEW SUBPANEL OR SERVICE PANEL FOR RAPID SHUTDOWNCOMPLIANT SERVICESNote:-All wiring to meet the 2017 NEC andFlorida electric codes. 60A Disconnect-Type of conduit to be determined on site by contractor. Must be metal if DC ran interior.AC Max Output CurrentAC Max Output Current * 1.25%Overcurrent Protection (A)No. of Current Carrying CondConductor Gauge (AWG)Inverter Output CktTo Overcurrent Protection Device324040<48Including the label belowMichael Knowlton5207 Indian Bend Ln.Fort Pierce, FL34951 #8 AWG THWN(2) Hot(1) Neutral #8 AWG EGCin @ least 3/4" Conduit Typically40AMain Service200A200A BusLoad side connection Per 705.12(D)(2)(3)(b)Use Matching or equivalent approved breaker if deratingBusbar Rating200200404040Load Side ConnectionMain Breaker SizeBus Rating *1.2-Main Break SizeMax Allowable Load SideLoad Size Breaker SizeUtility PV AC Disco60A Non-Fused DisconnectManual Lockable DisconnectLocated Adjacent to Utility MeterInverter Type:SolarEdge SE7600H-USPV Panel:(27)Aptos DNA-120-MF23-330WTotal Wattage:8,910WSystem meets the grounding requirements of NEC 690.43PHOTOVOLTAIC SYSTEM! AC DISCONNECT !RATED AC OUTPUT CURRENT: 32ANOMINAL OPERATING VOLTAGE: 240VACSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PVSYSTEM AND REDUCESHOCK HAZARD IN THEARRAY.SOLAR ELECTRICPV PANELS3/8 IN MIN. TEXT3/16 IN MIN. TEXT! WARNING !POWER SOURCE OUTPUT CONNECTION:DO NOT RELOCATE THIS OVERCURRENTDEVICE(4) #10 AWG Wire(1) #8 EGCIn 3/4" EMT typ orFMC,PVC, LFNC(depending on route toinv. Metal if interior)GEC NOTES Provide a grounding electrode system for an ungrounded system per 690.47(C)(3).- GEC must be installed per 250.64- GEC must be continuous un-spliced or irreversibly spliced from inverter to existing service ground system or continuous from the arrays to the existing service ground system.- If GEC is not continuous from the array to the existing service ground an additional ground system must be provided from the arrays to a grounding electrode per 690.47(D)- GEC must be min #8 AWG and installed in conduit- If GEC is not in conduit, it must be #6 min per NEC 690.54Donnie C Godwin2021.02. 04 15:02:04'00'06-
Godwin Engineering andDesign, LLC8378 Foxtail LoopPensacola, FL 32526D. Chad Godwin, PEChad@godwineng.comXR-10 17'XR-10 14'XR-10 7'Splice Bar49Iron Ridge UFO's646464'Iron Ridge Sleeves/End Caps20Iron Ridge Ground Lugs25Iron Ridge RailAptos DNA-120-MF23-330WSolarEdge SE7600H-US2727Combiner60A Non-Fused Disconnect1140A Breaker1P340 OptimizerUnirac FlashlocR-1# Modules (19)Pitch: 24°Azimuth: 269°R-2# Modules (8)Pitch: 24°Azimuth: 179°21'-11"54'-4"16'-7"33'-2"9'-3"5'-6"3'-3"LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL2/2/2021GM..605 W Lumsden Rd,Brandon, FL 33511855-577-7999Customer Info:S-1ADate:Drawn by:Revised by:Rev #: 00Rev Date:Page:Inverter Type:PV Panel:Racking:Total Wattage:Roof Type:Wind Load:Fastener Type:SolarEdge SE7600H-US(27) Aptos DNA-120-MF23-330WIron Ridge8,910WComposition Shingles20 to 27 DegUse 5/16" Dia 4" LagsInstall will be done to Manufacturer SpecMichael Knowlton5207 Indian Bend Ln.Fort Pierce, FL34951Plans satisfy zones FBC-1510.7.1Max cantilever is 16" as per manufacturer spec.Max Cantilever = Max Span * (13)=48"*(13)=16"Zone 1:Zone 2e:Max cantilever is 16" as per manufacturer spec.Max Cantilever = Max Span * (13)=24"*(13)=16"Max cantilever is 16" as per manufacturer spec.Max Cantilever = Max Span * (13)=24"*(13)=16"Zone 2r:Zone 3:Max cantilever is 16" as per manufacturer spec.Max Cantilever = Max Span * (13)=24"*(13)=16"Donnie C Godwin 2021.02.04'00'06- 15:02:28