HomeMy WebLinkAboutAPPROVED DESIGN PRESSURE (WINDOW &DOOR) r �
9 Sol
STORM
License e chobee Blvd,
4047 Okeechobee Blvd,Ste 105,
MART
west Palm)each, 33409
Phone{551}229-004648
ASuwzv StormSmanSE com
of Southeast Florida
Property Information Building Information
Owner: Kenneth Julien Wind Zone: 160 MPH.
Address: 8132 Links Way Exposure Category: C
Port 5t Lucie,FL 34986 Minimum Building Dimension: 6 ft.
Mean Roof Height: 16 ft.
K lit Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) IFElevation(ft) Pressure(Psf) Pressure(psf}
2 End 100 114 9.5 29.4 -36.3
3 End 260.5 114 9.5 27.3 -32.1
4 Int 36 73 7 32.6 -35.5
5 Int 73 73 7 31.1 -33.9
6 Int 36 73 7 32.6 -35.5
7 Int 32.5 81 7 32.6 -35.5
8 Int 94 96 8 29.9 -32.8
Prepared in accordance with:ASCE7-16,Chapter 311.Wind Loads•Components and Cladding.7th Edition(2020)Florida Building Cade.