Loading...
HomeMy WebLinkAboutENERGY CALCA 2.9.21FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SIME RESIDENCE Builder Name: Street: WATERSONG WAY Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH , FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(5189.2 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=5.0 4909.20 ft2 b. Frame - Wood, Adjacent R=13.0 280.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 10. Ceiling Types (4765.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 4765.00 ft2 6. Conditioned floor area above grade (ft2) 4765 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(1025.2 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU 1 CLST 6 200 a. U-Factor: Sgl, U=0.30 1025.20 ft2 b. Sup: Attic, Ret: Attic, AH: AHU 2 CLST 6 130 SHGC: SHGC=0.20 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 48.5 SEER:17.00 b. Central Unit 25.4 SEER:17.30 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 5.599 ft. Area Weighted Average SHGC: 0.200 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (4765.0 sqft.) Insulation Area EF: 0.980 a. Raised Floor R=19.0 3634.00 ft2 b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 1131.00 ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 138.10 Glass/Floor Area: 0.215 PASS Total Baseline Loads: 166.46 I hereby certify that the plans and specifications covered by Review of the plans and t � G this calculation are in compliance with the Florida Energy specifications covered by this l� Code. calculation indicates compliance G'00 with the Florida Energy Code. PREPARED BY- Before construction is completed DATE: 1-1 1-2 11 this building will be inspected for �N E S compliance with Section 553.908 0� I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Florida Statutes.ti' C7 ��i,�p� �.�`�•••�` OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/11/2021 10:43 AM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 10 FORM R405-2017 INPUT SUMMARY GFiEGKLIST REPORT PROJECT Title: SIME RESIDENCE Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 4765 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: WATERSONG WAY Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: JENSEN BEACH , Family Type: Detached FL , New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2887 28870 2 AHU 2 1878 18780 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfllID Finished Cooled Heated 1 LIVING ROOM 458 4580 No 0 1 Yes Yes Yes 2 DINING 138 1380 No 0 1 Yes Yes Yes 3 KITCHEN 268 2680 Yes 0 1 Yes Yes Yes 4 HALLWAY 118 1180 No 0 1 No Yes Yes 5 AHU 1 CLST 15 150 No 0 1 Yes Yes Yes 6 ELEV 2ND FLR 25 250 No 0 1 Yes Yes Yes 7 BATH 3 84 840 No 0 1 Yes Yes Yes 8 BEDROOM 3 234 2340 No 0 1 1 Yes Yes Yes 9 WIC 3 48 480 No 0 1 Yes Yes Yes 10 BEDROOM 2 249 2490 No 0 1 1 Yes Yes Yes 11 BATH 2 77 770 No 0 1 Yes Yes Yes 12 WIC 2 42 420 No 0 1 No Yes Yes 13 WASHER DRYER 48 480 No 0 1 Yes Yes Yes 14 BATH 1 66 660 No 0 1 Yes Yes Yes 15 AC STORAGE 50 500 No 0 1 Yes Yes Yes 16 ELEVATOR 1ST FL 25 250 No 0 1 Yes Yes Yes 17 STORAGE CLST 26 260 No 0 1 Yes Yes Yes 18 FOYER 238 2380 No 0 1 Yes Yes Yes 19 STAIRS 52 520 No 0 1 Yes Yes Yes 20 STORAGE 626 6260 No 0 1 Yes Yes Yes 21 M BATH 192 1920 No 0 1 Yes Yes Yes 1/11/2021 10:43 AM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 10 FORM R405-2017 INPUT SUMMARY GFiEGKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 M TOILET 21 210 No 0 1 No Yes Yes 23 M WIC 159 1590 No 0 1 Yes Yes Yes 24 LAUNDRY 88 880 No 0 1 Yes Yes Yes 25 AHU 2 CLST 16 160 No 0 1 No Yes Yes 26 HALL 107 1070 No 0 1 No Yes Yes 27 ELEV 3RD FLR 25 250 No 0 1 Yes Yes Yes 28 WIC 5 48 480 No 0 1 Yes Yes Yes 29 BATH 5 84 840 No 0 1 Yes Yes Yes 30 BEDROOM 5 220 2200 No 0 1 1 Yes Yes Yes 31 BEDROOM 4 234 2340 No 0 1 1 Yes Yes Yes 32 BATH 4 77 770 No 0 1 Yes Yes Yes 33 WIC 4 42 420 No 0 1 No Yes Yes 34 MASTER BEDROO 477 4770 No 0 1 1 Yes Yes Yes 35 STAIRS 3RD FLR 88 880 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor LIVING ROOM ___ ___ 458 ft2 19 1 0 0 2 Raised Floor DINING ___ ___ 138 ft2 19 1 0 0 3 Raised Floor KITCHEN __ ___ 268 ft2 19 1 0 0 4 Raised Floor HALLWAY ___ ___ 118 ft2 19 1 0 0 5 Raised Floor AHU 1 CLST ___ ___ 15 ft2 19 1 0 0 6 Raised Floor ELEV 2ND FLR __ ___ 25 ft2 19 1 0 0 7 Raised Floor BATH 3 ___ ___ 84 ft2 19 1 0 0 8 Raised Floor BEDROOM 3 ___ ___ 234 ft2 19 1 0 0 9 Raised Floor WIC 3 ___ ___ 48 ft2 19 1 0 0 10Raised Floor BEDROOM 2 ___ ___ 249 ft2 19 1 0 0 11Raised Floor BATH 2 ___ ___ 77 ft2 19 1 0 0 12Raised Floor WIC 2 ___ ___ 42 ft2 19 1 0 0 13SIab-On-Grade Edge Insulatio WASHER DRYE 14 ft 0 48 ft2 ___ 1 0 0 14SIab-On-Grade Edge Insulatio BATH 1 11 ft 0 66 ft2 ___ 1 0 0 15SIab-On-Grade Edge Insulatio AC STORAGE 10 ft 0 50 ft2 1 0 0 16SIab-On-Grade Edge Insulatio ELEVATOR 1ST 5 ft 0 25 ft2 ___ 1 0 0 17SIab-On-Grade Edge Insulatio STORAGE CLST 2 ft 0 26 ft2 1 0 0 1/11/2021 10:43 AM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 18SIab-On-Grade Edge Insulatio FOYER 20 ft 0 238 ft2 1 0 0 19SIab-On-Grade Edge Insulatio STAIRS 4 ft 0 52 ft2 1 0 0 20SIab-On-Grade Edge Insulatio STORAGE 49 ft 0 626 ft2 ___ 1 0 0 21Raised Floor M BATH ___ ___ 192 ft2 19 1 0 0 22Raised Floor M TOILET ___ ___ 21 ft2 19 1 0 0 23Raised Floor M WIC ___ ___ 159 ft2 19 1 0 0 24Raised Floor LAUNDRY ___ ___ 88 ft2 19 1 0 0 25Raised Floor AHU 2 CLST ___ ___ 16 ft2 19 1 0 0 26Raised Floor HALL ___ ___ 107 ft2 19 1 0 0 27Raised Floor ELEV 3RD FLR ___ ___ 25 ft2 19 1 0 0 28Raised Floor WIC 5 ___ ___ 48 ft2 19 1 0 0 29Raised Floor BATH 5 ___ ___ 84 ft2 19 1 0 0 30Raised Floor BEDROOM 5 ___ ___ 220 ft2 19 1 0 0 31Raised Floor BEDROOM 4 __ ___ 234 ft2 19 1 0 0 32Raised Floor BATH 4 ___ ___ 77 ft2 19 1 0 0 33Raised Floor WIC 4 ___ ___ 42 ft2 19 1 0 0 34Raised Floor MASTER BEDRO ___ ___ 477 ft2 19 1 0 0 35Raised Floor STAIRS 3RD FLR __ ___ 88 ft2 19 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 5328 f? 0 ft2 Light N 0.4 No 0.9 No 20 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 4765 ft2 N N 1/11/2021 10:43 AM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 10 FORM R405-2017 INPUT SUMMARY GHEGKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) LIVING ROOM 20 Blown 458 ft2 0.1 Wood 2 Under Attic (Unvented) DINING 20 Blown 138 ft2 0.1 Wood 3 Under Attic (Unvented) KITCHEN 20 Blown 268 ft2 0.1 Wood 4 Under Attic (Unvented) HALLWAY 20 Blown 118 ft2 0.1 Wood 5 Under Attic (Unvented) AHU 1 CLST 20 Blown 15 ft2 0.1 Wood 6 Under Attic (Unvented) ELEV 2ND FLR 20 Blown 25 ft2 0.1 Wood 7 Under Attic (Unvented) BATH 3 20 Blown 84 ft2 0.1 Wood 8 Under Attic (Unvented) BEDROOM 3 20 Blown 234 ft2 0.1 Wood 9 Under Attic (Unvented) WIC 3 20 Blown 48 ft2 0.1 Wood 10 Under Attic (Unvented) BEDROOM 2 20 Blown 249 ft2 0.1 Wood 11 Under Attic (Unvented) BATH 2 20 Blown 77 ft2 0.1 Wood 12 Under Attic (Unvented) WIC 2 20 Blown 42 ft2 0.1 Wood 13 Under Attic (Unvented) WASHER DRYE 20 Blown 48 ft2 0.1 Wood 14 Under Attic (Unvented) BATH 1 20 Blown 66 ft2 0.1 Wood 15 Under Attic (Unvented) AC STORAGE 20 Blown 50 ft2 0.1 Wood 16 Under Attic (Unvented) ELEVATOR 1ST 20 Blown 25 ft2 0.1 Wood 17 Under Attic (Unvented) STORAGE CLST 20 Blown 26 ft2 0.1 Wood 18 Under Attic (Unvented) FOYER 20 Blown 238 ft2 0.1 Wood 19 Under Attic (Unvented) STAIRS 20 Blown 52 ft2 0.1 Wood 20 Under Attic (Unvented) STORAGE 20 Blown 626 ft2 0.1 Wood 21 Under Attic (Unvented) M BATH 20 Blown 192 ft2 0.1 Wood 22 Under Attic (Unvented) M TOILET 20 Blown 21 ft2 0.1 Wood 23 Under Attic (Unvented) M WIC 20 Blown 159 ft2 0.1 Wood 24 Under Attic (Unvented) LAUNDRY 20 Blown 88 ft2 0.1 Wood 25 Under Attic (Unvented) AHU 2 CLST 20 Blown 16 ft2 0.1 Wood 26 Under Attic (Unvented) HALL 20 Blown 107 ft2 0.1 Wood 27 Under Attic (Unvented) ELEV 3RD FLR 20 Blown 25 ft2 0.1 Wood 28 Under Attic (Unvented) WIC 5 20 Blown 48 ft2 0.1 Wood 29 Under Attic (Unvented) BATH 5 20 Blown 84 ft2 0.1 Wood 30 Under Attic (Unvented) BEDROOM 5 20 Blown 220 ft2 0.1 Wood 31 Under Attic (Unvented) BEDROOM 4 20 Blown 234 ft2 0.1 Wood 32 Under Attic (Unvented) BATH 4 20 Blown 77 ft2 0.1 Wood 33 Under Attic (Unvented) WIC 4 20 Blown 42 ft2 0.1 Wood 34 Under Attic (Unvented) MASTER BEDRO 20 Blown 477 ft2 0.1 Wood 35 Under Attic (Unvented) STAIRS 3RD FLR 20 Blown 88 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belowo nrnt1 Space N Exterior Concrete Block - Int InstilVING ROO 5 18 0 10 0 180.0 ft2 4 0 0.4 0 2 E Exterior Concrete Block - Int InsIIIVING ROO 5 22 0 10 0 220.0 ft2 4 0 0.4 0 3 SE Exterior Concrete Block - Int InstiIVING ROO 5 9 11 10 0 99.2 ft2 4 0 0.4 0 4 S Exterior Concrete Block - Int InsIIIVING ROO 5 8 0 10 0 80.0 ft2 4 0 0.4 0 5 S Exterior Concrete Block - Int Insul DINING 5 14 0 10 0 140.0 ft2 4 0 0.4 0 1/11/2021 10:43 AM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space o 6 N Exterior Concrete Block - Int InsulKITCHEN 5 13 0 10 0 130.0 ft2 4 0 0.4 0 7 S Exterior Concrete Block - Int InsiNHU 1 CLST 5 3 0 10 0 30.0 ft2 4 0 0.4 0 8 S Exterior Concrete Block - Int InSELEV 2ND F 5 5 0 10 0 50.0 ft2 4 0 0.4 0 9 S Exterior Concrete Block - Int Insul BATH 3 5 5 0 10 0 50.0 ft2 4 0 0.4 0 10 S Exterior Concrete Block - Int InsBEDROOM 3 5 15 0 10 0 150.0 ft2 4 0 0.4 0 11 W Exterior Concrete Block - Int InsBEDROOM 3 5 14 0 10 0 140.0 ft2 4 0 0.4 0 12 S Exterior Concrete Block - Int Insul WIC 3 5 8 0 10 0 80.0 ft2 4 0 0.4 0 13 N Exterior Concrete Block - Int InsBEDROOM 2 5 15 0 10 0 150.0 ft2 4 0 0.4 0 14 W Exterior Concrete Block - Int InsBEDROOM 2 5 15 0 10 0 150.0 ft2 4 0 0.4 0 15 N Exterior Concrete Block - Int Insul BATH 2 5 11 0 10 0 110.0 ft2 4 0 0.4 0 16 E Exterior Concrete Block - Int InsVIJASHER DR 5 6 0 10 0 60.0 ft2 4 0 0.4 0 17 S Exterior Concrete Block - Int InsVASHER DR 5 8 0 10 0 80.0 ft2 4 0 0.4 0 18 S Exterior Concrete Block - Int Insul BATH 1 5 11 0 10 0 110.0 ft2 4 0 0.4 0 19 S Exterior Concrete Block - Int InSAJC STORAG 5 10 0 10 0 100.0 ft2 4 0 0.4 0 20 S Exterior Concrete Block - Int InsFLEVATOR 1 5 5 0 10 0 50.0 ft2 4 0 0.4 0 21 N Exterior Concrete Block - Int InsFrfORAGE C 5 2 0 10 0 20.0 ft2 4 0 0.4 0 22 S Exterior Concrete Block - Int Insul FOYER 5 14 0 10 0 140.0 ft2 4 0 0.4 0 23 W Exterior Concrete Block - Int Insul FOYER 5 6 0 10 0 60.0 ft2 4 0 0.4 0 24 W Garage Frame - Wood FOYER 13 4 0 10 0 40.0 ft2 0 0.1 0.4 0 25 NW Garage Frame - Wood FOYER 13 4 0 10 0 40.0 ft2 0 0.1 0.4 0 26 N Garage Frame - Wood FOYER 13 8 0 10 0 80.0 ft2 0 0.1 0.4 0 27 N Exterior Concrete Block - Int Insul STAIRS 5 4 0 10 0 40.0 ft2 4 0 0.4 0 28 W Garage Frame - Wood STAIRS 13 12 0 10 0 120.0 ft2 0 0.1 0.4 0 29 N Exterior Concrete Block - Int InsuSTORAGE 5 26 0 10 0 260.0 ft2 4 0 0.4 0 30 E Exterior Concrete Block - Int InsuSTORAGE 5 23 0 10 0 230.0 ft2 4 0 0.4 0 31 N Exterior Concrete Block - Int Insul M BATH 5 16 0 10 0 160.0 ft2 4 0 0.4 0 32 E Exterior Concrete Block - Int Insul M BATH 5 12 0 10 0 120.0 ft2 4 0 0.4 0 33 S Exterior Concrete Block - Int Insul M BATH 5 10 0 10 0 100.0 ft2 4 0 0.4 0 34 N Exterior Concrete Block - Int Insul M WIC 5 15 0 10 0 150.0 ft2 4 0 0.4 0 35 N Exterior Concrete Block - Int InsuLAUNDRY 5 7 0 10 0 70.0 ft2 4 0 0.4 0 36 S Exterior Concrete Block - Int InSELEV 3RD F 5 5 0 10 0 50.0 ft2 4 0 0.4 0 37 S Exterior Concrete Block - Int Insul WIC 5 5 8 0 10 0 80.0 ft2 4 0 0.4 0 38 S Exterior Concrete Block - Int Insul BATH 5 5 5 0 10 0 50.0 ft2 4 0 0.4 0 39 S Exterior Concrete Block - Int InsBEDROOM 5 5 14 0 10 0 140.0 ft2 4 0 0.4 0 40 W Exterior Concrete Block - Int InsBEDROOM 5 5 14 0 10 0 140.0 ft2 4 0 0.4 0 41 N Exterior Concrete Block - Int InsBEDROOM 4 5 14 0 10 0 140.0 ft2 4 0 0.4 0 42 W Exterior Concrete Block - Int InsBEDROOM 4 5 15 0 10 0 150.0 ft2 4 0 0.4 0 43 N Exterior Concrete Block - Int Insul BATH 4 5 11 0 10 0 110.0 ft2 4 0 0.4 0 44 E Exterior Concrete Block - Int InSMASTER BE 5 17 0 10 0 170.0 ft2 4 0 0.4 0 45 S Exterior Concrete Block - Int InSMASTER BE 5 29 0 10 0 290.0 ft2 4 0 0.4 0 46 N Exterior Concrete Block - Int InsSTAIRS 3RD 5 8 0 10 0 80.0 ft2 4 0 0.4 0 1/11/2021 10:43 AM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated WASHER DR None .27 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 2 E 2 Vinyl Low-E Single Yes 0.3 0.2 N 144.0 ft2 7 ft 0 in 1 ft 4 in None None 3 SE 3 Vinyl Low-E Single Yes 0.3 0.2 N 48.0 ft2 7 ft 0 in 1 ft 4 in None None 4 S 5 Vinyl Low-E Single Yes 0.3 0.2 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 5 S 5 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 6 N 6 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 7 S 9 Vinyl Low-E Single Yes 0.3 0.2 N 6.2 ft2 2 ft 0 in 1 ft 4 in None None 8 S 10 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 9 W 11 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 10 W 11 Vinyl Low-E Single Yes 0.3 0.2 N 20.0 ft2 5 ft 0 in 1 ft 4 in None None 11 N 13 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 12 W 14 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 5 ft 0 in 1 ft 4 in None None 13 W 14 Vinyl Low-E Single Yes 0.3 0.2 N 20.0 ft2 5 ft 0 in 1 ft 4 in None None 14 N 15 Vinyl Low-E Single Yes 0.3 0.2 N 4.0 ft2 2 ft 0 in 1 ft 4 in None None 15 S 22 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 16 W 23 Vinyl Low-E Single Yes 0.3 0.2 N 48.0 ft2 12 ft 0 in 1 ft 4 in None None 17 N 27 Vinyl Low-E Single Yes 0.3 0.2 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None 18 N 29 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 19 E 30 Vinyl Low-E Single Yes 0.3 0.2 N 144.0 ft2 10 ft 0 in 1 ft 4 in None None 20 E 32 Vinyl Low-E Single Yes 0.3 0.2 N 40.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 21 N 34 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 22 N 35 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 23 S 37 Vinyl Low-E Single Yes 0.3 0.2 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 24 S 38 Vinyl Low-E Single Yes 0.3 0.2 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 25 S 39 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 26 W 40 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 27 W 40 Vinyl Low-E Single Yes 0.3 0.2 N 20.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 28 N 41 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 29 W 42 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 30 W 42 Vinyl Low-E Single Yes 0.3 0.2 N 20.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 31 N 43 Vinyl Low-E Single Yes 0.3 0.2 N 4.0 ft2 2 ft 0 in 1 ft 4 in None None 32 E 44 Vinyl Low-E Single Yes 0.3 0.2 N 96.0 ft2 10 ft 0 in 1 ft 4 in None None 33 S 45 Vinyl Low-E Single Yes 0.3 0.2 N 45.0 ft2 2 ft 0 in 1 ft 4 in None None 34 N 46 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 1/11/2021 10:43 AM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 600 ft2 600 ft2 28 ft loft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 W holehouse Proposed ACH(50) .000444 5559.2 304.99 572.59 .1381 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 34 kBtu/hr 1 COP:1 17 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Singl SEER: 17 48.5 kBtu/hr 1455 cfm 0.8 1 Singl SEER: 17.3 25.4 kBtu/hr 762 cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None AHU 1 CLST 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 200 ft2 Attic 6 130 ft2 Attic Attic 20 ft2 Default Leakage AHU 1 CLS (Default) (Default) 13 ft2 Default Leakage AHU 2 CLS (Default) (Default) 1 1 2 2 1/11/2021 10:43 AM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: ling Jan F eb Mar pr May Jun Ju Oct Nov Dec H IM �X� �X� € ri Jun 4 Jul Aug Oct Sep �Xj NovOct �X� JJanan Venting lX� FFeb eb Maar r Apr May Jun [ Jul [ Aug lXj [ ]Sep l lx� Nov DDec ec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU 1 CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 ELEV 2ND FLR Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WASHER DRYER Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 AC STORAGE Default(8 Ibs/sq.ft. ft2 ft 0.3 ELEVATOR 1ST FL Default(8 Ibs/sq.ft. ft2 ft 0.3 STORAGE CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRS Default(8 Ibs/sq.ft. ft2 ft 0.3 STORAGE Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU 2 CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 ELEV 3RD FLR Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 5 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 5 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 5 1/11/2021 10:43 AM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 9 of 10 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRS 3RD FLR 1/11/2021 10:43 AM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 10 of 10 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.