HomeMy WebLinkAboutProduct Approval FREDERICK J. LEWIS, State Certified Building Contractor
Florida Licensed/Insured #CB C047820
9765 Fleming Grant Road, Micco, FL 32976
Tel: 772-646-1703 E-Mail: filewis9765@att.net
THtSE PLAINS AID ALL PROPOSED WORK
May 4, 2017 - ARV:51 kL ir. T TU s '`i'C('pp*CTIOdIS
To: �a n n�l i ��°� fig' RFOUIRE0 6�Y Ff LD INVE—CTOAS THAT
MAY BE NECESSARY IN ORDER TO
t
Re: f'S =flee U�`C1 I �'� COMPLY WITH ALL APPUCABLE CODES,
Remove and replace lap siding on four gable ends (hardeeboard)
Remove and replace lap siding on front of house
Replace 4'X8' vertical siding on southeast ccorner of house from
Porch to rear corner
Price includes labor, materials, permit, clean=up and removal of all debris
Total price CONCEALED FASTENERS OR ATTACHMENTS, $24.600.
ARE T HE RESPONSIBILITY OF THE
Deposit (East Coast Lumber materials)CONTRACTOR OF RECORD 5,000.
Skyline Scaffold rental S I���vl 1.000.
Deposit Fred Lewis Construction �u ./t(,J 5,000.
Balance ST. LUCIE COUNTY $13,600
BUILDING DIVISION
REVIEWED
FOR CO NCE
Due upon 50% completion of sidin REVIEWED BY 7,600.
DATE 6
PLANS AND PERMIT
Due upon completion MUST SE KEPT ON JOB OR 6,000.
NO INSPECTION WILL DE MADE
Accepted by: Fred Lewis Construction Accepted by: Owner
Date Date
FILE COPY
ll
MIAMI• AIIAt1II-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONO1111C RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) Nv%vw.miamidade.eov/cconomy
James.Hardie Building Product,Inc.
10901 Elm Avenue
Fontana,CA 92337
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: "Hardie", "Cem" and "Prevail"Planks and Panels Fiber Cement Siding and Soffit
APPROVAL DOCUMENT:Drawing No.PNL,PLK& SOFF,titled "HardiePanel,CemPanel,Prevail
Panel;HardiePlank,CemPlank Prevail Lap Siding;HardieSoff it,CemSoffit Panel;Installation Details
Wood/Metal Stud Construction",sheets I through 12 of 1.2,dated 04/24/2013,prepared by the
manufacturer,signed and sealed by Ronald I.Ogawa,P.E., bearing the Miami-Dade County Product
Control revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade
County Product Control Section.
MISSILE IMPACT RATING:Large and Small Missile Impact Resistant
LABELING:A permanent label with the manufacturer's name or logo,Plant City,Florida,and the
following statements: "ASTM C 1186 Type A compliant"and"Miami-Dade County Product Control
Approved"is to be located on each siding plank or panel and per FBC 1715.9.2 and 1715.9.3 on soffit
panels.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in'he applicable building code negatively affecting the performance of this product.
'TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA f# 12-0214.14 and consists of this page 1 and evidence page E-1,as
well as approval doctunent mentioned above.
The submitted documentation was reviewed by Carlos M.Utrera,P.E.
NOA No. 13-0311.07
CMIAMlilDADE Courtnr Expiration Date:May 1,2017
Approval Date:May 9,2013
0510 1�,17I Page 1 COPY
James Hardie Building Products,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. PNL,PLK&SOFF,titled"HardiePanel, CemPanel,Prevail Panel;
HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel;
Installation Details Wood/Metal Stud Construction", sheets i through 12 of 12,dated
04/24/2013,prepared by the manufacturer,signed and sealed by Ronald I. Ogawa,
P.E.
B. TESTS
1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Cyclic Wind Pressure Loading per FBC,TAS 203-94
along with marked-up drawings and installation diagram of HardiePlank, HardieSoffit
and HardiePanel,prepared by Intertek Testing Services NA LTD,Test Report No.
100733361COQ-004,dated 08/24/2012,with revision 1 dated 04/25/2013, signed and
sealed by Rick Curkeet,P.E.
C. CALCULATIONS
1. None,
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources(RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to 2010 FBC issued by Ronald L Ogawa&
Associates,Inc.,dated 04/26/2012,signed and sealed by Ronald 1. 0gawa,P.E.
4 75�/o
I/V0 13
Carlos A Utrera,P.E.
Product Control Examiner
NUA No.13-0311.07
Expiration Date:May 1,2017
Approval Date: May 9,2013
E- 1
—WALL LENGTH PRODUCT DESCRIPTION
Stud Spacing at 16"O.C. SEE HardiePanel®,CernpaneM,&
B4__i DETAIL A Prevail®Panel Siding materials are
nonasbestos fiber-cement products
T•----�... ;� --+ •.•-- '•f�7yt7.ts��viry r / 5/8"thick!5 ply APA rated -,
tested in accordance with ASTM
111 QA /Q ( plywood sheathing in
+l1 �' ,•.�.; � \ C1186 Grade II,Type A and meeting
;. �� ;, • ' /�, accordance with Florida the requirements of the Florida
p� aE i ��� �\ �1 l3uildng Code Section Building Code.
VA CO UV 'ilnl will+lhb 'llorid� r �' i •� +• 2322.3
WALL 9WI&W#C& I ; 1
Amcpbm ow Noi/.i. G's''�l % �., �C Water-resistive PANEL DIMENSIONS
HEIGHT i f;;!7 -4 I Width length Thickness
bonier per Florida
4' 8,9,10' 5l16"
i j ?E �O• �, ��` i; Building Code
R Section 1404.2
Miami Ph�duer4"c�tral j' �QF � �I.��C?� x► DESIGN PRESSURE.RATING
2•X 4"S-P-F Installation Design Pressure
Wood Studs -76 psf
S
Wood tads
------------
B
i
HardiePanei, Impact Resistant—
Planks installed over 5/8"thick/5
j SECTI.ON B_B Cempanel, Ply
Nails at 16"O.G.(typ.)3/$"Minimum Edge Distance Prevail Panel APA rated plywood sheathing
Siding
DETAILA Sheathing fastener,as described in HARDIEPANEL,_CEMPANEL,PREVAIL PANEL SIDING_fNSTALLATION DETAILS
Note 1 All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's
installation recommendations, and the applicable sections of the Florida Building Code.
0 N Wood studs where HardiePanei, Cempanel, Prevail Panel Siding will be installed shall be
Panel fastener, as described in designed by an Engineer or Architect per the Florida Building Code and the requirements of this
Note 2 N.O.A.
[Note 1]5!8"thick/5 ply APA rated plywood sheathing shall be attached to the studs in
accordance with Florida Building Code Section 2322.3.
• The siding panels shall be installed over 5/8"thick/5 ply APA rated plywood sheathing supported i
< < HardiePanel, Cempanel, by a minimum of2"X4"S-P-F wood studs spaced a maximum of 16"O.C.
1 Prevail Panel Siding [Note 21 The siding panel fastener shall be a 2"long, 0.223"head diameter, 0.092"shank
diameter, corrosion resistant siding nail;the fasteners shall be spaced at 6"O.C.at panel edges
and intermediate studs:the fasteners shall be driven through the 518"thick/5 ply APA rated
% plywood sheathing into wood studs located at 16"O.C.
Water-resistive barrier per Fasteners shall have a minimum edge distance of 3/8"and a minimum clearance of 2"from
Florida Building Code Section comers.
1404.2 I
HARDIEPANEL,CEMPANEL, PREVAIL PANEL
5/8"thick/5 ply APA rated INSTALLATION DETAILS WOOD STUD CONSTRUCTION
plywood sheathing fastened in
accordance with Florida Building James Hardie Building Products, Inc.
Code Section 232-2.3 10901 Elm Avenue
2"X 4"S-P-F Wood Studs
Fontana, CA 92337
The wall and soffit frames are to be designed Phone:909-356-6300 SIZE FScV,No owG NO Rev
by the Architect or Engineer of Record in Fax 909-427-0634 A PNL-PLK-SOFF 1
compliance with the Florida Building Code, Creator: E. Gonzales SCALE 1/2"=T-o" Date:4/24/2013 SHEET t OF 12
i Cladding
Fastener Spacing per Florida
Building Code Section 2322.3� 16.00m.
• �" Framing
• ^_��'~ • \ � �• •in r Florida
•I Sheathing
Fastener g per o
Building Code
Section 2322.3
\ IIf Gp -
ty1 _
PRODUCL iLEV45M �� • •( `<< �•'.•.` L
tm COMV ymg with the Florida \ ��
Bm7ffm6 CO& r; 1
Aotrpmm No 13 p /1, , ; Nb-
-o STATE 01
r ti�tt► aera Cettaa Pt OR S
FRAMING
■ NOMINAL 2"X 4"S-P-F WOOD STUDS 16"O.C. FASTENED
WITH 3-1/2' 16d COMMON NAILS(2 PER TOP AND FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
BOTTOM CONNECTION) NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
S_H__EATHING —
■ NOMINAL 5/8"THICK/5 PLY APA RATED PLYWOOD HARDIEPANEL,CEMPANEL, PREVAIL PANEL
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA INSTALLATION DETAILS WOOD STUD CONSTRUCTION
BUILDNG CODE SECTION 2322.3
CLADDING
1 THE PANEL IS FASTENED WITH 2"LONG,0.223"HEAD _ _ James Hardie Building Products, Inc.
DIAMETER,0.092"SHANK DIAMETER, CORROSION 10901 Elm Avenue
RESISTANT SIDING NAILS, PLACE NAILS 6"O.C.AT Fontana, CA 92337
PANEL EDGES AND INTERMEDIATE STUDS Phone:909-356 6300 size FscM.NO owc NO Rev
j Fax 909-427-0634 A PNL-PLK-SOFF 1
I
Creator: E. Gonzales SCALE 1"= 1'll" Date:4/24/2613 s+eEr 2 OF 12
—WALL LENGTH---.-
Stud Spacing at 16"O.C. SEE DETAIL A HardiePanelO,CempaneKD,&Prevail®
a*- Panel Siding materials are nonasbesros
plywood sheathing fastened
._._..._ ............. .....:.r......._.....rr- N � 5 thick/5 ly APA rated accordance dance with ASTM�Ct1 86 Grade q,
/8
{ I ! ii�l�r OG;4 (` to metal studs as described Type A and meeting the requirements of',
the Florida Building Code.
> cx>tac7 silaVti �.( ,�� in Note 1 g
i t t aet-Oyi"with Wo Florida
i '•j BkviQzggCod� i• �; ,f PANELDIMENSIONS
j Water-resistive
o Width i ticap�i�na+No i� i1.t77 dth Lenth Thickness
WALL �• ct i No
. barrier per Florida 4 g,g,g01
51,16"
HEIGHT i y?Z * Building Code
CA Section 1404.2
STATEDESIGN_PRESSURE RATING
S Installation Design Pressure
t j t I I i — D,0" F4 0 R�Q 20ga,3 5/8"X 1-Sl8"
i »_^ Metal Studs -104 psf
of Metal C-stud
Cempa
}_ ._-- r s- —_3- impact Resistant—
,,,m,� N Panel installed over 5/8"thick/5 ply
g 4__� SECTION H-6 � Cempanel,el,
Prevail Panel APA rated plywood sheathing
3/8"Minimum Edge Distance Nails at 6"O.C. (typ.) Siding
HARDIEPANEL—CEMPANEL_PREVAIL_PANEL SIDING INSTALLATION DETAILS.
• All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's
DETA{L A installation recommendations,and the applicable sections of the Florida Building Code.
Metal studs where HardiePanel, Cempanel, Prevail Panel Siding will be installed shall be
Sheathing fastener, as designed by an Engineer or Architect per the Florida Building Code and the requirements of this
described in Note 1 N.O.A.
■ [Note 1]5/8"thick/5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oa
/ Panel fastener,as described in at panel edges and all intermediate supports using a No.8-18,0.315"head diameter x 1-1/4`long
Note 2 bugle head screw
r The siding panels shall be installed over 5/8"thick/5 ply APA rated plywood sheathing
supported by a minimum 20ga, Nominal 3-5/8"X 1-5/8"Metal C-studs spaced a maximum of 16"
O.C.
t HardiePane]S Siding [Note 2]The siding panel fastener shall be a minimum No. 8-18, 0.315"head diameter X 1-5/8'
long'ribbed bugle head screw("or screw shall have at least 3 full threads penetrating metal
r framing); the fasteners shall be spaced at 6"O.C.at panel edges and intermediate studs,the
\ i fasteners shall be driven through the 5/8"thick/5 ply APA rated plywood sheathing into metal
Water-resistive barrier per studs located at 16"O.C.
Florida Building Code Section Fasteners shall have a minimum edge distance of 3/8"and a minimum clearance of 2"from
1404.2 corners.
1 HARDIEPANEL,CEMPANEL, PREVAIL PANEL
5/8"thick/5 pry APA rated INSTALLATION DETAILS METAL STUD CONSTRUCTION
plywood sheathing fastened
to metal studs as described James Hardie Building Products, Inc.
in Note 1. 10901 Elm Avenue
20ga, 3-5l8"X 1-5/8"Metal C-stud
Fontana,CA 92337
The wall and soffit frames are to be designed Phone:909-356-6300 SIZE owa No REV
by the Architect or Engineer of Record in Fax 909-427-0634 A PNL-PLK-SOFF 1
compliance with the Florida Building Code. Creator: E.Gonzales SCALE 1/2"=1'-0" Date:4/24/2D13 sHEer 3 OF 12
Cladding 1
6.00in. 16.001in.
6.00h I I
II i
.) .I I• 1.1 Framing
I II Ii II I
i I It
I I Shaming
6.00in.
I t I
A �
I II
6.00in. I t I t
"OGA '
as«timpybe..&dw Flunik
Dlit&*Caen
A=Veoste No Lr^
7 I lei o. 121
By
> Z- o I t t ' �` STATE OF
I
SI O N
FRAMING
■ NOMINAL 20 GAUGE 3-5/8"X 1-5/8"STEEL STUDS 16"O.C. I
FASTENED WITH 5/8"WAFER HEAD SCREWS(2 PER TOP
AND BOTTOM CONNECTION)
■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
■ NOMINAL 5/8"THICK/5 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6"OC AT PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A HARDIEPANEL, CEMPANEL,PREVAIL PANEL
NO.8-18,0.315"HEAD DIAMETER X 1-114" LONG BUGLE INSTALLATION DETAILS METAL STUD CONSTRUCTION
HEAD SCREW
CLADDING
■ THE PANEL IS FASTENED WITH NO.8-18, 0.315"HEAD James Hardie Building Products, Inc.
DIAMETER X 1-518" LONG CORROSION RESISTANT * Fontana,
Elm Avenue
RIBBED BUGLE HEAD SCREWS(SCREW SHALL HAVE AT Fontana, CA 92337
LEAST 3 FULL THREADS PENETRATING THE METAL Phone:909-356-6300 SIZE FSC+n reo )'�W-1 aev
FRAMING), PLACE SCREWS 6"O.C.AT PANEL EDGES
AND INTERMEDIATE STUDS Fax 909-427-0634 A PNL-PLK-SOFF 1
Creator: E. Gonzales sCALE 1"= 1'-0" Date:4124/2013 sr+eer 4 OF 12
Stud Spaang at 16"4.C. WALL LENGTH SEE PRODUCT AE5CR1PTION
DETAIL A HardiePlank®,Cemplank®, &
---- _J---- Prevail®Plank Lap Siding materials
......_.....1_: - ---.-----
....i,..___......i.r........._�.L...._....._. __..._. _r._. .......,_�_.__...,i_r r� ~`\ 5/8"thick 15 ply APA are nonasbestos fiber-cement
- ?' I Y �1 t M I f E, 11 rated plywood products tested in accordance with
sheathing in ASTM C1186 Grade II,Type A and
i ?i i, i; i i i ii�i���. meeting the requirements of the
i.; t j ii� � _ .1
accordance vrith
1 ;; Florida Building Code.
j } l as mtoYmB wft the Fbcida i Florida Building Code
WALL I i i,` DwI&OFCode �,, i 1 .47 ,�►� �` � r;, Section 2322.3
HEIGHT l i i ; Fxpi�tiru f ' ; �. PANEL DIMENSIONS
1 ,, :! _ Water resistive Width Length Thickness
i barrier per Florida e _1/2" 12' 5116"
y�11�
i ---~ Building Code
trH t ;;. ;�► Section 1404.2 pESIGNPRES$UFE RAfFG_ _
Hi L WX '4J ` 2"X 4"S-P-F Installation Design Pressure
Wood Studs Wood Studs -92 psf
--------------
Lap Siding Impact Resistant--
3/4"Minimum Edge Distance Nails at 16"O.C.(typ.) tl'��., �ir� L SECTiO_�� Planks installed over 5/8"thick/5 ply
g_B 1-114"tall X 5116" APA rated plywood sheathing
thick starter strip
DETAILA Sheathingfastener,,as HARDIEPI.ANK,CEMPI..ANK,,PREVAI,LLLAP SIpING INSTALLATION_DETAILS
described in Note 1 All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's
installation recommendations,and the applicable sections of the Florida Building Code.
\" Wood studs where HardiePlank,Cemplank, Prevail Lap Siding will be installed shall be designed by an
\ Engineer or Architect per the Florida Building Code and the requirements of this N.O.A.
1 [Note 1]5/8"thick/5 ply APA rated plywood sheathing shall be attached to the studs in accordance s
I , Sidina fastener,as with Florida Building Code Section 2322.3.
1 described in Note 2 Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4"vide
laps at the top of the plank such that the exposure area of each plank is 5&1/4"vertically.
HardiePlank, [Note 2]The siding fastener shall be a 2-1/2"long,0.223"head diameter, 0.092"shank diameter,
( — Cemplank, Prevail corrosion-resistant siding nail;The siding is fastened s 8-1/4"O.C.vertically and 16"O.C. horizontally;
i Lap Siding fasteners are driven into wood studs through 5/8"thick/5 ply APA rated plywood sheathing,fasteners i
are placed in the overlapping area approximately 3/4"from the bottom edge of the overlapping plank.
' Vertical joints shall be placed over studs.
Water-resistive barrier The planks shall be installed over 5/8"thick/5 ply APA rated plywood sheathing supported by a
per Florida Building minimum of 2"X4"S-P-F wood studs spaced a maximum of 16"O.C.
Code Section 1404.2 Fasteners shall have a minimum edge distance of 3/8".
5/8"thick/5 ply APA rated HARDIEPLANK,CEMPLANK, PREVAIL LAP SIDING
—� plywood sheathing fastened INSTALLATION DETAILS WOOD STUD CONSTRUCTION
in accordance with Florida S '
Building Code Section James Hardie Building Products, Inc.
2322,3 10901 Elm Avenue
Fontana, CA 92337
2"X 4"S-P-F Wood Studs Phone:909-356-6300 s,ze FscN n a Qv,G ao asv
The wall and soffit frames are to be designed Fax g09-427-0634 A PNL-PLK-SOFF 1
by the Architect or Engineer of Record in
compliance with the Florida Building Code. Creator: E. Gonzales scALe 1/2"=1'-0" Date:4124/2Q13 sxeEr 5 OF 12
Fastener Spacing per Florida
Building Code Section 2322.3--'! 16 in.OC Cladding
I �
Framing
---------------- ---- --------
Fastener Spacing per Florida I Sheatl>M
Building Code Section 2322.3
-------------------------------- -------------------------- -
0.75in '
i
-------------- ---------------------------- ----------- - - -
PRODUCT REVLSED
a6-Gyms web the)Elan&
l3m1�Coa
Ar_cvto"w No f �' f1 G}7 kN� ��"'•%
- .. ._. ,e� i pA
vliero. adt Product L ontrot \� �'
s8.25in.
. , , No. 121
STATE OF
FRAMING !�� F�ORIDP-
F
• NOMINAL
HIN 1/2" 6d COMMON 2 PER TOP AND �Al.
WOOD STUDS
FASTENED
WITH .sS�0 E �
BOTTOM CONNECTION) ( sloop$
■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND�f Vfff LOAD ARE
BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
• NOMINAL 5/8"THICK/5 PLY APA RATED PLYWOOD —
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA HARDIEPLANK,CEMPLANK, PREVAIL LAP SIDING
BUILDING CODE SECTION 2322,3 INSTALLATION DETAILS WOOD STUD CONSTRUCTION
CLADDING
• PLANKS OVERLAP 1-1/4"
■ THE EXPOSURE IS 58-1/4" James Hardie Building Products, Inc.
■ THE PLANKS ARE FACE NAILED NTH 2-112" LONG,0.223" 10901 Elm Avenue
HEAD DIAMETER, 0.092"SHANK DIAMETER, CORROSION- w Fontana,CA 92337
RESISTANT SIDING NAILS, PLACED 3/4"UP FROM THE Phone:909-35"300 SIZE FSCMNO DWG NO REV
BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION Fax 909-427-0634 A PNL-PLK-SOFF 1
Creator: E. Gonzales SCALE 1"=1'•0" Date:412412013 SHEET 6 OF 12
Stud Spacing at 16"O.C. WALL LENGTH SEE PRODUCT DESCRIPTION
Bt_ DETAIL HardiePlank(®, Cemplank®,and
--� 518^thick/5 ply PA Prevail®Plank La Siding materials
..........-� ---- �..--r..............r•-_.._._.�. ,,_......_._ are nonasbestos fiber-cement
I.[.... i ��_~��+� s ! 7!--��' s ` rated plywood products tested in accordance with
sheathing fastened
ASTM C1186 Grade It,Type A and
to metal studs as
i meeting the requirements of the
described in Note 1
! ! a,` �e with Am Fto.� , Florida Building Code.
! (' Codr Water-resistive
WALL t` 1 - ' ! , = barrier per Florida
HEIG PLANK DIMENSIONS
! t K MENSI
Building Code Width Length Thickness
s.' i. : ' • 'i Section 1404.2 5 9-1/2" 12' 5/16"
! I !! i i r Prc,Auct�Go ►I l; ?i ` 20ga,3 5I8"X 1-5/8^ DESIGN_PRESSURE_RATING
Metal C-stud
i �OF �� R Installation Design Pressure
1..---- ................?.......- t).............a ......__...__li. .._....__.. --- �Q 44/ \�� HardiePlank, Metal Studs -92 psf
B ( l ►� ss/O•... —� ���� Cemplank,Prevail p
'� t �CTlO Lap Siding Impact Resistant
NQ S
Planks installed over 5/8"thick/5 PIY
3/4"Minimum Edge Distance Nails at 16"O.C.
(ryp•) +~ g-g 1-1l4"tat)X 5/16"
thick starter strip APA rated plywood sheathing
DETAIL,6 HARDIEPLANK.CEMPLANK. PREVAIL_LAP SIDING INSTALLATION DETAILS
�'� All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's installation
Sheathing fastener, as recommendations, and the applicable sections of the Florida Building Code.
described in Note 1 Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an
Engineer or Architect per the Florida Building Code and the requirements of this N.O.A.
/ [Note 1]5/8"thick/5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc at panel
/ Siding fastener, as edges and all intermediate supports using a No.8-18, 0.315"head diameter x 1-1/4" long bugle head screw
r described in Note 2 ' Planks shall be applied horizontally commencing from the bottom course of the wall with 1-114'wide laps at
( the top of the plank such that the exposure area of each plank is s 8-1/4"vertically.
[Note 2]The siding fastener shall be a minimum No.8-18,0,315"head diameter X 2-1/4"long'bugle head
s r HardiePlank, screw over metal studs('or screw shall have at least 3 full threads penetrating metal framing);The siding is
r Cemplank, fastened s 8-1/4"O.C.vertically and 16"O.C. horizontally;fasteners are driven into metal studs through 5/8"
thick/5 ply APA rated plywood sheathing,fasteners are placed in the overlapping area approximately 3/4" j
7 Prevail Lap Siding from the bottom edge of the overlapping plank.
\ / 0 Vertical joints shall be placed over studs.
Water-resistive The planks shall be installed over 5/8"thick/5 ply APA rated plywood sheathing supported by a minimum
\ 20ga, Nominal 3-5/8"X 1-5/8"Metal C-studs spaced a maximum of 16"O_C.
barrier per Florida Fasteners shall have a minimum edge distance of 3/8".
Building Code
Section 1404.2 HARDiEPLANK,CEMPLANK, PREVAIL LAP SIDING
5/8"thick/5 ply APA rated INSTALLATION DETAILS METAL STUD CONSTRUCTION
plywood sheathing fastened to
metal studs as described in James Hardie Building Products, Inc.
Note 1 _ 10901 Elm Avenue
Fontana,CA 92337
209a, 3-5/8"X 1-5/8"Metal C-stud Phone:909-356-6300 SIZE Fsc+r,No owl No REV
The wall and soffit frames are to be designed Fax 909 427_0634 A PNL-PLK-SOFF 1
by the Architect or Engineer of Record in
compliance with the Florida Building Code. Creator: E. Gonzales SCALE 112"=1'-0" Date;4/24/2013 SHEET 7 OF 12
6.001n. 16 in.OC Cladding
I '
6 001n.
i
Framing
------ I■ �-- •
6.001n.00 I Sheathing
i
-�
•--•---•--------•-------------- ------------------------------------------
0.75in
-- • •i ��-
I '
i�lt the ' OGA(vM
• w commlyinE.r Florida I 1( F
BMW"Code
--- - L?�e r. t-; I `
121
Miax i �i l `�, STATE OF w
0.25in.
_ �OR10P• ���'����
• G
FRAMING
■ NOMINAL 20 GAUGE 3-5l8"X 1-5/8"STEEL STUDS 16" `l �
O.C. FASTENED WITH 5/8"LONG RIBBED BUGLE HEAD
SCREWS(2 PER TOP AND BOTTOM CONNECTION)
■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
• NOMINAL 5/8"THICK/5 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6"OC AT PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A
NO.8-18,0.315"HEAD DIAMETER X 1-1/4' LONG BUGLE HARDIEPLANK,CEMPLANK, PREVAIL LAP SIDING
HEAD SCREW
C_L_A_DDING INSTALLATION DETAILS METAL STUD CONSTRUCTION
• PLANKS OVERLAP 1-1/4'
• THE EXPOSURE IS 5 8-1/4" James Hardie Building Products, Inc.
■ THE PLANKS ARE FASTENED WITH NO,8-18,0.315" 10901 Elm Avenue
HEAD DIAMETER X 2-1/4" LONG CORROSION- •
Fontana, CA 92337
RESISTANT RIBBED BUGLE HEAD SCREWS(SCREW
SHALL HAVE AT LEAST 3 FULL THREADS Phone:909-356-6300 51ze FSCM NO oVVG NO RSV
PENETRATING THE METAL FRAMING), PLACED 3/4"UP Fax 909-427-0634 A PNL-PLK-SOFF 1
FROM THE BOTTOM EDGE OF THE PLANK AT EACH
STUD LOCATION Creator: E. Gonzales SCALE 1"=1'-0' Date:412412013 SHEET 8 OF 12
WAIL LENGTH SEE P1�30DUCT DESCRI�f10N
Stud Spacing at 16"O.C. DETAIL A HardieSoffit®&Cemsoffi*materials are
B� nonasbestos fiber-cement products tested in
i — � accordance with ASTM C1166 Grade 11,Type A
�_..�_.� .........:...:,.-.--_.._ ,;._s..1..ti...4...---_-... and meeting therequirements r uirements of the Florida
Building Code.
} i �.i ;
'� SOFFIT DIMENSIONS
{.; I ,.i ` }.� i. 2°x 4"5-P-F Width Length Thickness
Wood Studs N
WALL
HEIGHT __P_RE.,SSURE__
RATING
i ;.; ;; ;•i HardieSoffd, Installation Design Pressure
} } Cemsoff,t Wood Studs 70 psf
`,
[]t
B t---�
'1 PRa =REVMM
Nails at 4"O.C.(typ.)
318"Minimum Edge Distance B ft mQ F�°`� No. 4 21
Accept im tvo f 3 V 3/" :Z ;
E Darr
lay -a ' STATE OF
;�
HARDIES_O_F,FIT�CEMS_O_F�tX PANEL INSTAJLLAJIQN DETAILS
Soffit fastener,as + All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's
described in Note 1 installation recommendations,and the applicable sections of the Florida Building Code.
\ • Wood studs where HardieSoffit,Cemsoffit will be installed shall be designed by an Engineer or
Architect per the Florida Building Code and the requirements of this N.OA
HardieSoffit,Cemsoffit The soffit shall be installed over minimum 2"X4"S-P-F wood studs spaced a maximum of 16"O,C.
[Note 1]The soffit fastener shall be a 2"long,0,223"head diameter,0.D92"shank diameter,
corrosion resistant siding nail;the fasteners shall be spaced at 4"O.C.at panel edges and
1 intermediate studs;the fasteners shall be driven into wood studs located at 16"O.C.
+s Fasteners shall have a minimum edge distance of 3/8"and a minimum clearance of 2"from corners.
HARDIESOFFIT,CEMSOFFIT PANEL
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
'Minimum 2"X 4"S-P-F Wood Studs James Hardie Building Products,Inc.
The wall and soffit frames are to be 10901 Elm Avenue
designed by the Architect or Fontana,CA 92337
Engineer of Record in compliance Phone:909-356-6300 SIZE PSCM NO om NO Rev
with the Florida Building Code. Fax 909-427-0634 A PNL-PLK-SOFF 1
Creator:E.Gonzales SCALE 1r2"-1'-0" Dane:4/242013 sHeET 9 OF 12
4.001n. 16.00in. Cladding
. . . . . . . . . . . .
Framing
.4.00in.1
1
• PRoDwrlltEVl +,, ; N 4GAV�lq
Aux�pND G�/1ji�/ `�� • ..
• Emir atioo cla0e. / "c'�7 NO. 121
• 1'4 P'A d C°"w STATE OF
FRgMING
NOMINAL 2"X 4"S-P-F WOOD STUDS 16"O.C.FASTENED
WITH 3-1/2" 16d COMMON NAILS(2 PER TOP AND BOTTOM FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
CONNECTION) NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY
THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE
WITH THE FLORIDA BUILDING CODE
CLADDING
THE SOFFIT IS FASTENED WITH 2•LONG,0.223"HEAD HARDIESOFFIT,CEMSOFFIT PANEL
DIAMETER,0.092"SHANK DIAMETER,CORROSION INSTALLATION DETAILS WOOD STUD CONSTRUCTION
RESISTANT SIDING NAILS,PLACE NAILS 4"O.C.AT PANEL (B
EDGES AND INTERMEDIATE STUDS James Hardie Building Products, Inc.
_ 10901 Elm Avenue
Fontana,CA 92337
Phone:909-35"300 SIZE FSW No DOG NO Rev
Fax 909-427-0634 A PNL-PLK-SOFF 1
Creator. E.Gonzales SLUE 1"=1'-0" Date:4/24/2013 SNEET 10 OF 12
+ — WALL LENGTH SEE
PRODUCT DESCRIPTION
Stud Spacing at 16"O.C. DETAIL A HardieSoffitO&Cemsoffit®materials
B�--- are nonasbestos fiber-cement products
..;.•........... _.... ........_ tested in accordance with ASTM C1186
'1'1..
Grade II,Type A and meeting the
_.._ requirements of the Florida Building
Code.
WALL ! i !'} !'� " i'I ( 20ga,3-5/8"X 1-5/8" SOFFIT.DIMENSIONS
_ }} �•� 'i 1 Metal C-stud fdth Length Thickness
HEIG i'i 8'
HardieSoffit,
Cemsoff t DESIGN PRESSURE RATING
Installation Design Pressure
Metal Studs -55,9Z
B•f---! �- SECTION_B-B �,1 j. ... A'
PROLliICi]�2EYLSED � �� � ''• -
Nails at 6'O.C.(typ.) as wmpiy:W with the Fioci& �
3/8"Minimum Edge Distance 11widingCode N
1
0 No 12,4cceptm►on 13��%i 1•�i
3 sTATE o
DETAI.L-A R-
L-6 �c Pdct u Ccad JC
ro �tr s�;• ERICA �` ,�Y, '
/ \ HAiRPIE;QFFIT,CEMSOEFIT_PANEI_INSTALLATIONDETAILS ���0NAL BA
�\ All installation shall be done in conformance with this Notice of AcceptanfWOWManufacturer's S
installation recommendations,and the applicable sections of the Florida Building Code.
Soffit fastener,as Metal studs where HardieSoffit,Cemsoffit will be installed shall be designed by an Engineer or
described in Note 1 Architect per the Florida Building Code and the requirements of this N.O.A.
/
• The soffit shall be installed over minimum 20ga, Nominal 3-5/8"X 1-5/8"Metal C-studs spaced
t
HardieSoffit.Cemsoffit a maximum of 16"O.C.
• [Note 1]The soffit fastener shall be a minimum No.8-18,0.315"head diameter X 1-1/4"long*.
ribbed bugle head screw("or screw shall have at least 3 full threads penetrating metal
framing);the fasteners shall be spaced at 6"O.C.at panel edges and intermediate studs;the
fasteners shall be driven into metal studs located at 16"O.C.
Fasteners shall have a minimum edge distance of 3/8"and a minimum clearance of 2"from
\� comers.
HARDIESOFFIT, CEMSOFFIT PANEL
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
' 20ga,3-5/8"X 1-5/8"Metal C-stud , 10901 Elm Avenue
i The wall and soffit frames are to be Fontana, CA 92337
-- designed by the Architect or Engineer Phone;909-356-6300 SIZE FSCM NO i anc No REV
Of Record in compliance with the Fax 909-427-0634 A PNL-PLK-SOFF 1
Florida Building Code`
Creator, E. Gonzales Scare 1/2"=1'-0" Date:4Y24/2013 SHEET 11 OF 12
6.00in"� 16.00in.---� '
Cladding
• Fmming
' 6.00ir.
P'ROWC't gE�Lg'D
oomoyiN w is ft Florida
BY
OM& covaol \ �' 2-1 �t
' cc
O,c�' 11"
SS1014
FRAMING
• NOMINAL 20 GAUGE 3-5/8"X 1-5/8"STEEL STUDS 16"O.C.
FASTENED WITH 5/8"WAFER HEAD SCREWS(2 PER TOP FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
AND BOTTOM CONNECTION) NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN I
COMPLIANCE WITH THE FLORIDA BUILDING CODE
CLADDING HARDIESOFFIT, CEMSOFFIT PANEL
THE SOFFIT IS FASTENED WITH NO.8-18, 0.315"HEAD INSTALLATION DETAILS METAL STUD CONSTRUCTION
DIAMETER X 1-1/4"LONG CORROSION RESISTANT RIBBED
BUGLE HEAD SCREWS(SCREW SHALL HAVE AT LEAST 3 — "
FULL THREADS PENETRATING THE METAL FRAMING), PLACE James Hardie Building Products, Inc.
SCREWS 6"O.C.AT PANEL EDGES AND INTERMEDIATE 10901 Elm Avenue
STUDS
Fontana, CA 92337
Phone:909-356-6300 SME Fsc►a NOUNG No Rev
Fax 909-427-0634 _ A PNL-PLK-SOFF 1
Creator: E. Gonzales scan~ 1"_'I'-0" Date:4/24/2013 SHEET 12 OF 12