Loading...
HomeMy WebLinkAboutProduct Approval (2) rICC EVALUATION . .• Accepted • • Trusted e c SERVICE Report • I I ICC-ES 1 :00 i 0 . This report is subject to re4newal 10/2018. DIVISION:06 00 00-WOOD,PLASTICS AND COMPOSITES SECTION:0616 00—SHEATHING DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION SECTION:07 2S 00—WATER-RESISTIVE BARRIERS/WEATHER BARRIERS SECTION:07 27 00—AIR BARRIERS REPORT HOLDER: HUBER ENGINEERED WOODS;LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE,SUITE 300 CHARLOTTE,NORTH CAROLINA 28262 EVALUATION SUBJECT: ZIP SYSTEM®WALL SHEATHING Icc ]cc ICC Q)P 49 i) PING LWD Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council e (WSSPC)Award in Excellence" A Subsidiary of Wrr ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service,LLC,express or implied as to any fending or other matter in this report,or as to any product covered by the report. 2=1= eon Copyright©2016 ICC Evaluation Service,LLC. All rights reserved. FILEP c0 , e ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1474 Reissued October 2016 This report is subject to renewal October 2018. www.(cc-es.ora-1 (800)423-6687 1 (562)699-0543 A Subsidiary of the International Code Council® DIVISION:06 00 00—WOOD,PLASTICS AND 3.0 DESCRIPTION COMPOSITES 3.1 Sheathing Panel: Section:0616 00--Sheathing The ZIP Systern®Wall Sheathing panel is an OSB wood- DIVISION:07 00 00—THERMAL AND MOISTURE structural panel having a laminated exterior facer. The PROTECTION Exposure 1 OSB complies with US DOC PS 2 for wood Section:07 25 00—Water-resistive BarriersiWeather structural panels.The exterior facer is a medium-density, Barriers phenolic-impregnated, polymer-modified sheet material Section:07 27 00—Air Barriers qualifying as a Grade D water-resistive barrier(required by Section 2510,6 of the 2012 and 2009 IBC).The panels are REPORT HOLDER: nominally 4 feet wide by 8, 9, 10, 11 or 12 feet long and have a square-finished-edge or machined-edge profile. HUBER ENGINEERED WOODS,LLC When tested in accordance with ASTM E96 water ONE RESOURCE SQUARE method the polymer-modified sheet overlay has a 10925 DAVID TAYLOR.DRIVE,SUITE 300 minimum vapor permeance of 12 perms 168.6 X CHARLOTTE,NORTH CAROLINA 28262 10"kg/(Pa-s-m2)]. Equivalent Water Vapor Transmission (800)933.9220 www.huberwood.com rate (WVT) of the polymer-modified sheet overlay is 83.4 g/(24h-m)-when tested at 73.4+F(23°C). EVALUATION SUBJECT: The water-resistive barrier and air barrier properties of the ZIP System®Wall Sheathing Panels are not affected ZIP SYSTEIN®WALL SHEATHING when the panels are manufactured to comply as facing materials.for Sips in accordance with Section R610.3.2' 1.0 EVALUATION SCOPE and Table R610.3.2 of the 2015 IRC(Section R613.3.2 Compliance with the following codes: and Table R613.3.2 of the 2012 and 2009 IRC). ■2015,2012 and 20091ntemational,Budding Code®(IBC) 3.2 Seam Tape: ® The ZIP SystemTts seam tape-is a self-adhering membrane ■2015, 2612 and 2009 Intemationa/Residential Code tape consisting of acrylic adhesive laminated to a (IRC) polyolefin backing,The tape is 0.0121nch'(0.30 mm)thick ■2015,2012 and 2009 International Energy Conservation with a minimum width of 3/4 inches(95.2 mm),and comes Code®(IECC) in rolls of various lengths. Properties evaluated: 4.0 INSTALLATION ■Weather resistance 4.1 General: ■Air leakage Installation of ZIP System®Wall Sheathing panels must comply with the applicable code, this report and the 2.0 'USES manufacturer's published installation instructions. The manufacturer's published installation,Instructions must be ZIP System® Wall Sheathing panels are used as available at the jobsite during installation. combination wall sheathing,air barrier,and water-resistive 4.2 Application: ' barrier, This report recognizes the use'of ZIP System pp Sheathing, when installed with ZIP SystemTte flexible 4.2.1 General:The ZIP System®Wall Sheathing panels flashing seam tape,in walls of Type V'construction(IBC) must be attached to wall framing in accordance with the and dwellings under the IRC, and as an alternate to the applicable code for wood structural panels, and in water-resistive barrier required in Chapter 14 of the IBC compliance with their panel span rating.The panels must and Chapter 7 of the IRC,and to the air barrier required by be installed with the.polymer-modified sheet overlay Sections R402.4 and C402.5.1 of the 2015 IECC(Sections '. facing the exterior. In accordance with the manufacturers- R402.4 and C402.4.1 of the 2012 IECC;Sections 402.4.1 published Installation instructions,it is recommended that and 502.4.3 of the 2009 IECC). the square edges,of the panels be installed with a gap !CC-ES Evaluation Reporla ore not to be cam7rtrrdar representing oer{helm or any other atMbmer,rof tpecylaofry oddruxd rrorare fl ey fo 6e mnrfrued as an endornment of the subject of the repon or o recrommendaaon far ltr we Them a no warmly by ICC Evaluation Service•LLC,espretr or hnplfed,as \� / to arryQnding or olhermoaer lrt thtr mpare,orartoonypmdctcoveredbythereport. Copyright®20181CC Ewivation Service,LLC.All rights reserved. Page 1 of 6 ESR-1474 I Most Wide/yAccepted and Trusted Page 2 of 6 between adjacent panels and between panels and alternative to what is specified in, those codes listed in dissimilar materials.All ZIP System®Wall Sheathing panel Section 1.0 of this report, subject to the following seams must be sufficiently sealed with ZIP System seam conditions: tape.All overlay surfaces must be dry and free of sawdust 6.1 This evaluation report and the manufacturer's and dirt prior to application of the ZIP System seam tape. published installation instructions, when required b The ZIP SystemTM seam tape must extend a minimum of he code official, must be submitted at the time of ' 1 inch(25.4 mm)past the panel edge Tmjoint intersections permit application. and must be centered within /2 inch (12.7 mm)over the middle of panel seams.The tape must be pressed firmly to 6.2 The ZIP System® Wall'Sheathing panels must be adhere to the surfaces and seal the seams.Wrinkles in the manufactured, Identified and Installed in accordance ZIP SystemTM seam tape are acceptable unless they with this report and the manufacturer's published create a leak path to the panel seam, installation instructions. In the event of a conflict 4.2.2 Flashing: Flashing complying with the applicable between the instructions and this report, this report must govern. code must be installed at the perimeter of door and window assemblies, penetrations and terminations of 6.3 The ZIP Systeme Wall Sheathing panels must be exterior wall assemblies, exterior wall intersections with covered with a code-complying exterior wall covering, roofs, chimneys, porches, decks, balconies, and similar or one that is recognized in a current ICC-ES projections, and at built-in gutters and similar locations evaluation report. where moisture could enter the wall.An adhesive-backed 6.4 The OSB sheathing must comply with US DOC PS-2. flashing tape recognized in a current ICC-ES evaluation report must be installed to seal all ZIP System® Wall 6.5 Fire-resistance-rated construction is outside the Sheathing flashing joints. Penetration items must be scope of this report sealed to the panels. The adhesive-backed flashing tape 6.0 EVIDENCE SUBMITTED must comply with the ICC-ES Acceptance Criteria for 6.1 Data in accordance with the ICC-ES Acceptance Flexible Flashing Materials(AC148)and must be installed in accordance with the manufacturer's published Criteria for Water-resistive Membranes Factory- Installation instructions. See Figures 1 through 7 of this Water-resistive Barriers (AC310), dated May 2008 report for typical dashing, water-resistive barrier and air (editorially revised August 2015). barrier assembly installation details. 4.2.3 Air Barrier Assembly: ZIP System® Wall 6.2 Air leakage data In accordance with ASTM E2357. Sheathing fastened to maximum 24-inch-on-center 7.0 IDENTIFICATION (610 mm), wood wall framing, using minimum 6d nails Each ZIP System®Wall Sheathing panel described in this spaced at 6 inches(152 mm)around panel edges and at report must bear a label that includes the manufacturer's 12 inches (305 mm) in the field, leaving a1/8-Inch name(Huber Engineered Woods LLC),the product name, (3.18 mm) gap between panels, forms an air barrier nominal panel thickness, the evaluation report number assembly when the gaps between panels and the (ESR-1474),and the words"Mill 229,Crystal Hill,Virginia'; perimeter of penetrations are sealed with ZIP SystemTM "Mill 228,Easton,Maine';'Mill 227,Commerce,Georgia"; seam tape as required by Section 4.2.1.The assembly has or'Mill 290,Broken Bow,Oklahoma."The OSB sheathing demonstrated a2maximum air leakage of 0.0072 cfm/ft2 must also bear a label demonstrating compliance with 10.037 U(S•m)l infiltration and 0.0023 cfm1f? US DOC PS 2 from an approved inspection agency.The [0.012 U(s•m)] exfiltration at a pressure differential of ZIP SystemTM seam tape roll must be labeled with the 1.57 psf (75. Pa) when tested in accordance with ZIP System, logo and the evaluation report number ASTM E2357. ESR-1474(see Figure 8). 5.0 CONDITIONS OF USE The ZIP System®Wall Sheathing panel and tape system described in this report complies with, or is a suitable t ESR-14T4 I Most Widely Accepted and Trusted Page 3 of 6 &WE V� E Ym I� rac sDmpo ADNM+nL SACK m AMOVE-M i1i17RIW TAPE RQYIiI FAAILIIC � _ avil.�nuro ' tow-ar�ssmE vanswE+nua ronw -TME 6190E ' Y7NDCm HW7 ' SILL SECTION HEADER SECTION VADOW,taus aurnoE ZIP SYSIFM' - WALL}{EAIFIWC ' AAHESyE-BACKED FLASf114G'TAPE IME LOW-PRESSURE POLYURETHANE FOAM JAMS SECTION FIGURE 1—TYPICAL CROSS SECTIONS OF FLANGED WINDOW ESR4474 Most Widely Accepted and Trusted Page 4 of 6 GRrsue Rom mob s >SAII'�CAniNO 170DG'M 9A,\ - /L1dalE:BI.CRV rt/emw'T/iC 0.GUGN i4AYV>G -1 Edema= Fm CNAM DAM ImF-Flasara �waflxus FIA9M17G WCABG WA F A7GiII ROUGH F000 DP LYSRNr WAIL 40TMG GUT= FYI yDwvjt II SILL SECTION HEADER SECTION b - WNDOW d1M8 aP SYSTEM' AMMYE-OACKEO WALL SHEA1}tlNC FASMNO TAPE OUTSIDE 'GULI(INC ROACH O'DOG INSIDE POWIRETHANE FOAM JAMS SECTION FIGURE 2—TYPICAL CROSS SECTIONS OF INSTALLED BRICK MOLD WINDOW a ESR-1474 I Most Widely Accepted and Trusted Page 6 of 6 ZIP SYSTEMTM ZIP SYSTEMTM WALL SHEATHING WALL SHEATHING WALL FRAMNO , ' WALL FRAM NG ADHESIVE-BACKED FLASHING TAPE ADHESIVE-BACKED FLASHNO TAPE FLASHING FASTENERSHING METALFLASHING CAUNTE SHINO INO TE • FLAS490 FASTENER BASE FIASHINO ADHESIVE,W*DFLASHINGTAPE FLASHING FASTENER _ HINO TAPE ROOF UNOERLAYMENT(FELT) ROOFIINDERLAYMENTffELT) ROOF SHFATHNG ROOF SHEATHNO ROOF JOIST ROOF JOIST FIGURE 3—ROOF-WALL INTERSECTION(OPTION 1) FIGURE 4—ROOF-WALL INTERSECTION(OPTION 2) rm AM ' OO kDm taT fN1T8fO1q O[illbd 1WlPADO— OO 6lNOd nI1PGOlO M4 tiR'Ii ULMAIT 14 euaa 4OWAXT OOOIpT qq I,lp�MOgpF9OD W� n= A�WWROOIPiO�IC4pW V�f� YO03Rt3ID61�� �A�O¢OIa1NTgT!N R�OO tOOtIILudJ�p ,•1 ��� T• mC/awOtae •a.'1t,•.'• � fana6R0�rO `,',5' �t . k i WWWI* nwna - AtROtL FIGURE 5—TYPICAL WALL-SILL INTERSECTION FIGURE 6-7YPICAL WALL-SILL INTERSECTION AND FLASHING DETAILS FOR BRICK SIDING AND FLASHING DETAILS FOR LAPPED SIDING ESR4474 I Most Widely Accepted and Trusted Page 6 of 6 Adhesive-Backed Flash' Tape FIGURE 7—INSTALLATION AT PENETRATION OPENING(NON-FIRE-RESISTANCE RATED) FIGURE 8—LABELING FOR THE ZIP SYSTEM SEAM TAPE ROLL e SERVICE Most Widely Accepted and Trusted IMES Evaluation Report ESR-1474 FBC Supplement Reissued October2016 This report is subject to renewal October 2018. www.lcc-es.orct 1 (800)423-6687 1 (562)699-0543 A Subsidiary of the International Code Councils DIVISION:06 00 00—WOOD,PLASTICS AND COMPOSITES Section:0616 00—Sheathing DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION Sectlon:07 25 00—Water-Resiative BarrlerstWeather Barriers Section:07 27 00—Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS,LLC ONE RESOURCE SQUARE 10926 DAVID TAYLOR DRIVE,SUITE 300 CHARLOTTE,NORTH CAROLINA 28262 (800)933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM°WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: -The purpose of this evaluation report supplement Isla indicate that ZIP System®Wall Sheathing panels, recognized in ICC-ES master evaluation report ESR-1474,have also been evaluated for compliance with the codes noted below. Applicable code editions: ■2014 Florida Building Cods,.—Building ■.2014 Florida Building Code—Residential, 2.0 CONCLUSIONS The ZIP System®Wall Sheathing panels,described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, comply with the 2014 Florida Building Code--Building and the 2014 Florida Building Code—Residenfial,provided the design and installation are in accordance with the International Building Code®provisions noted in the master report, Use of the ZIP System®Wall Sheathing panels for compliance with the High-Velocity Hurricane Zone_provisions of the 2014 Florida Building Code—Building and the 2014 Florida Building Code—Residenfial has not been evaluated, and is outside the scope of this evaluation report. For products falling,under Florida Rule 9N-3,verification that the report holder's quality-assurance program is audited by,a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity(or the.code official,when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report,reissued October 2016. 1CC-ES Ewruation ReparR are not to be carcrtrued as representing oesthenp or any olherattributes nor spedJlcally addressed,nor arc they to be cawlrued gran endorsementofihesuyectofdterepartoraremmmendoilonforhiwc There isno warranryby1CCEw1ca11on Servroe,LLC,express or imp/ied,w to anyfbtding or other miter in this report,or as to any produci covered by the report. Copyrfpht02016[CC Evaluation Semdoe,LLC.All righta reserved. - Papa 1 of 1 tICC EVALUATION SERVICE Most Widely Accepted and TrUsted IMES Environmental Report VAR-1012 Reissued September 2015 This report is subject to renewal September 2017. www.lt c-es,aralep 1 (600)423-6687 (562)699-0543 A Subsidiary of the international Code Council® DIVISION:06 00 00—WOOD,PLASTICS AND ..2013 California Green Building Standards Code COMPOSITES (CALGreen),Title 24,Part 11(see Table 3 for details) Section:0612 00--Structural Panels National Green Building Standard (ICC 700.2008) Section:as 16 00--Sheathing (see Table 4 for details) DIVISION:07 00 00—THERMAL AND MOISTURE, • National Green Building Standard (ICC 700-2012) PROTECTION (see Table 5 for details) Section:07 21 00—Thermal Insulation, Section:07 25 00—Water-Resistive Barriers/Weather • LEED for Homes 2008(see Table 6 for details) Barriers •:LEED v4 for Homes Design and Construction (see Section:07 27 00—Air Barriers Table 7 for details) REPORT HOLDER: • LEED 2009 for New Construction and Major Renovations (see Table 8 for details)LEED 2009 for HUBER ENGINEERED WOODS,LLC Schools New Construction and Major Renovations(see 10925 DAVID TAYLOR DRIVE Table 9 for details) CHARLOTTE,NORTH CAROLINA 28262 • LEED v4 for Building Design and Construction(BD+C) (800)933-9220 (See Table 10 for details) www.huberwood.com ANSIlGBI 01-2010 — Green Building Assessment • EVALUATION SUBJECT: Protocol for Commercial Buildings (see Table 11,for details) ADVANTECH°(AT-SERIES)SHEATHING SPAN; 2.0 USES ADVANTECH®(AT-SERIES)FLOOR SPAN;ZIP SYSTEM® • ®, o ROOF SHEATHING;ZIP SYSTEM°WALL SHEATHING; AdvanTech (AT-Series) Sheathing Span, AdvanTech ZIP SYSTEM°RSHEATHING(INSULATING SHEATHING) (AT-Series)Floor Span,ZIP System Roof Sheathing and ZIP System® Wall Sheathing are used for a variety of 1.o EVALUATION SCOPE interior and exterior framing and sheathing applications. Compliance with the following evaluation criteria: ZIP System® R-Sheathing panels are used as combination wall sheathing and continuous insulation in • ICC-ES Environmental Criteria for Determination of Bio- conventional'wood-framed wall construction. . based Material Content(EC102),dated March 2012. 3.0 DESCRIPTION . ICC-ES Evaluation Guideline for Determination of AdvanTech®(AT-Series)Sheathing Span and AdvanTech® Source of Recovery, Extraction, Harvest and (AT-Series) Floor Span wood structural panels are Manufacture for Materials or Products (EC114), dated Exposure 1 oriented strand board (OSB) panels March 2012 manufactured with strands from a single wood species or a • ICC-ES Environmental, Criteria for Determination of combination of wood species blended with an exterior-type Formaldehyde Emissions of Composite Wood and adhesive system to comply with'U.S. DOC PS-2 and the Engineered Wood Products (EC108), dated March applicable ICC-ES report as indicated in Table 1. 2012. ZIP System®.Roof Sheathing and ZIP Systeme Well • ICC-ES Environmental Criteria for Determination of Sheathing wood structural panels are OSB panels with Certified Wood and Certified Wood Content in Products laminated, resin-impregnated, polymer-modified sheet (EC109),dated March 2012. material manufactured to comply with U.S.DOC PS-2 and the applicable ICC-ES reports as indicated in Table 1.The, Compliance eligibility with the applicable sections of panels are installed with ZIP System® self-adhering the following green building rating systems,standards membrane tape, The tape is outside the scope of this and codes: evaluation report. • 2012 International Green Construction Code (IgCC) ZIP System® R-Sheathing Is an insulated sheathing (see Table 2 for details) made by combining 7/le-inch-thick ZIP System® Wall ICGEs Vrrlfmlloa ofAlMbulee Report,ere ieraedmderthe IMES VAR Firvlro, _rd Pngmm.Theta mpare men01o6ee0m1medmnrpxnnlingaea1hed.WM other woibma„at rpeelfw11y odd=g aor'are thry ro be rnmlmed m ax etdamemeat of the mb)w of thr mpod or a« xemfadl for 10 me.nme is m,ro, fy by ICC Ewhatlox SIMce,LLC,rVm.or implied•m10-yP,0,g orothermaxerin ft report,am m axyp,odnd coati dby the,e m- Copydght 0 2016 ICC Evaluagan SarAce,LLC.A0 rights reserved. Page 1 of 6 ESR-1474 Most Widely Accepted and Trusted Page 4 of 6 W1S0[ IMaOE 8 S45PJI" 7911'SwTop " 90aw M-\ :� RWIX P1AW1C "Esm PMIU8MKW ibW Cgo= AGt MY uv lmV-fl37 s•olwr+ErnAu ronu aoxcrn-uom aan Sao � wc nwc nA�am eaoi Hum+o ar.rsml. au�s umna OUrZE gem[ wmvxluA SILL SECTION HEADER SECTION ZIP 5551EN' AOHE`YE-EIAMEO WALL SHEghIINC i ." nASHING'TAPE OIITSICE 'CAULKWr. ROUGH OPENING IHSIOE LRES'a7RE 'e POLOW-P.MIHANE FOAM JAMB SECTION FIGURE 2—TYPICAL CROSS SECTIONS OF INSTALLED 8R1CK MOLD WINDOW ESR-1474 I Most Widely Accepted and Trusted Page 6 of 6 ZIP SYSTEMTM ZIP SYSTEMTM WALLSHEATHING WALL SHEATHING WpLLFRMANO WALLFRWNG ' _ADHES)VE•BACKED FLASHING TAPE ADHESIVE-BACKED FLASHNGTAPE FLASKNO FASTENER INEI'AL FLASHING OOUNTERFLASHINO i - FLASHING FASTENER BASE FIASHNO ADHESIVE.SAt iED FLASHNG TAPE FLASHNO FASTENER R60F IINOERLAYmENT(FELT) ADHESIVE-SACKED FLASHING TAPE ROOF SHEATHING ROOFUNDERLAYMENT FELT) ROOF SHEATHING ROOF JOIST ROOF JOIST FIGURE 3—ROOF-WALL INTERSECTION(OPTION 11 FIGURE 4—ROOF-WALL INTERSECTION(OPTION 2) � -rwoa 4nlmu+ roaa wremtro �m,q aa�wa nn� waza xwnwon u° txsaxswMT9 400fty wiOlq) Heim 0011��Wy-polqopY7p IIOG1 �VVJLK1�q � /i ImliRdWVAIIwMT�N QDII ,` f Auu aMNI .0mm .7DiODL FIGURE 5—TYPICAL WALL-SILL INTERSECTION FIGURE B—TYPICAL WALL-SILL INTERSECTION AND FLASHING DETAILS FOR BRICK SIDING AND FLASHING DETAILS FOR LAPPED SIDING ESR4474 I Most Widely Accepted and Trusted Page 6 of 6 Adhesive-Backed Flash( 'Tape • FIGURE 7—INSTALLATION AT PENETRATION OPENING(NON-FIRE-RESISTANCE RATED) FIGURE 8—LABELING FOR THE ZIP SYSTEM SEAM TAPE ROLL I ICC EVALUATION SERVICE Most Widely Accepted and TrUSted i IMES Evaluation Report ESR-1474 FBC Supplement ' Reissued October 2016 This report is subject to renewal October 2018. www.lec-es.ora 1 (800)423-6587 (562)699-0543 A Subsidiary of the International Code Council® DIVISION:06 00 00—WOOD,PLASTICS AND COMPOSITES Section:0616 O"heathing DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION Section:07 26 00—Water-Rssistive Barrlers[Weather Barriers Section:07 27 00-A1r Barriers REPORT HOLDER: HUBER ENGINEERED WOODS,LLC. ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE,SURE 300 CHARLOTTE,NORTH CAROLINA 28262 (800)933-9220 www.huberwood.com EVALUATION SUBJECT. ZIP SYSTEM®WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP System®Wall Sheathing panels, recognized in )CC-ES master evaluation report ESR-1474,have also been evaluated for compliance with the codes noted below. Applicable code editions: a 2014 Florida Building Code—Building ■.2014 Florida Building Code—Residentlal 2,0 CONCLUSIONS 'The ZIP System®Wall Sheathing panels,described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, comply with the 2014 Florida Building Code—Building and the 2014 Florida Building Code—Residential,provided the design and installation are in accordance with the international Building Code®provisions noted in the master report. Use of the ZIP Systeme Wall Sheathing panels for compliance with the High-Velocity Hurricane Zone provisions of the 2014 Florida Building Code—Building and the 2014 Florida Building Cade—Residential has not been evaluated,,and is outside the scope of,this evaluation report.. For products falling under Florida Rule 9N-3,verification that the report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted'is the responsibility of an approved validation entty(or the code official,when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report,reissued October 2016. [CC-ES Evolvaiton Reports are not to be mauard as representing aesthetics or any other andbutee not specylmlly addressed,nor are they to be camtrued as an endorsement of thg!whiecl of the repair or emmmen ivion for lu we There is no worronry byrCC Evafmtion Service,LLC,express or implied,as \� I to mryfhdingar athermaaer in this report•arm to pnyproductcovered by the report. g, Copyright®2016 ICC Evaluallon Service,LLC.A I rights reserved. Prago 1 or 1 EVALUATIONICC SERVICE Most Widely Acrepted and Trusted IMES Environmental Report VAR-1012 Reissued September 2015 This report is subject to renewal September 2017. www.Icc-es.org/eo 1 (800)423-6587 1 (562)699-0643 A Subsidiary of the International Code Council® DIVISION:06 00 00-WOOD,PLASTICS AND 2013 California Green Building Standards Cade COMPOSITES (CALGreen),Title 24,Part 11(see Table 3 for details) Section:0612 Section:06 16 00—Structural tructural Panels . National Green Building Standard (ICC 700-2008) O (see Table 4 for details) DIVISION:07 00 00—THERMAL AND MOISTURE - : National Green Building Standard (ICC 700-2012) PROTECTION (see Table 5 for details) Section:07 21 OD—Thermal Insulation Section:07.25 00—Water-Resistive BarrierslWeather • LEED for Homes 2008(see Table 6 for details) Barriers • LEED v4. for Homes Design and Construction.(see Section:07 27 00—Alr Barriers Table 7 for details) REPORT HOLDER:' LEED 2009 for New Construction and Major. Renovations (see Table 8 for details) LEED 2009 for HUBER ENGINEERED WOODS,LLC Schools New Construction and Major Renovations(see 10925 DAVID TAYLOR DRIVE Table 9 for details) CHARLOTTE,NORTH CAROLiNA 28262 . LEED v4 for Building Design and Construction(BD+C) www huber o (See Table 10 for details) www.huberwood.com " ' ANSI/GBI 01-2010 — Green. Building Assessment EVALUATION SUBJECT: Protocol for Commercial Buildings (see Table 11 for details) ADVANTECH®(AT-SERIES)SHEATHING SPAN; 2.0 USES ADVANTECHs(AT-SERIES)FLOOR SPAN;ZIP SYSTEM® ROOF SHEATHING;ZIP SYSTEM®WALL SHEATHING; AdvanTecO (AT-Series) Sheathin%Span, AdvanTeche. ZIP SYSTEM®R-SHEATHING(INSULATING SHEATHING).`- (AT-Series)Floor Span,ZIP System Roof Sheathing and ZIP'System®Wall Sheathing are used for a variety of 1.0 EVALUATION SCOPE interior and exterior framing and sheathing applications. Compliance with the following evaluation criteria: ZIP System® R-Sheathing panels 'are used as combination wall sheathing and continuous insulation in - ICC-ES Environmental Criteria for Determination of Bio- - conventional wood-framed wall construction. based Material Content(EC102),dated.March 2012. 3.0 DESCRIPTION • ICC-ES Evaluation Guideline for Determination of AdvanTech®(AT-Series)Sheathing Span and AdvanTech® Source of Recovery, Extraction, Harvest •and Manufacture for.Materials or Products(EC114),dated I (AT-Series) Floor Span wood structural panels are March 2012 Exposure 1 oriented strand board (OSB) panels' manufactured with strands from a single wood species or a r ICC-ES Environmental Criteria for Determination of combination of wood species blended with an exterior-type Formaldehyde Emisslons of Composite Woad and adhesive system to comply with U.S.DOC PS-2 and the Engineered. Wood Products (EC108), dated March- applicable ICC-ES report as indicated in Table 1. e 2012: -ZIP System® Roof Sheathing and ZIP System® Wall ICC-ES Environmental Criteria for Determination of Sheathing wood structural panels are OSS panels with Certified Wood and Certified Wood Content in Products laminated, resin-impregnated, polymer-modified sheet (EC109),dated March 2012. material manufactured to comply with U.S.DOC PS-2 and the applicable ICC-ES reports as indicated in Table 1.The Compliance eligibility with the applicable sections of panels are installed with ZIP System® self-adhering the following green building rating systems,standards 'Membrane tape. The tape is outside the scope of this ' and codes: evaluation report • 2012 International Green Construction Code .(IgCC) ZIP System® R-Sheathing Is an insulated sheathing (see Table 2 for details) made by combining '1464nch-thick ZIP System° Wall= IMES lit-d ofAlefbdes Repassme luo,dorderthe ICC-ES VAR Enw—ew&Pmgw 7heeerepo,0mend fo be WWOed at repnxndnggees/herlm armry other alMbafu mof spedfoolly addreved nor'are Ihry la bo rnminred m an erdoriemenf of the nrbJen of dre fapmr a o reaommeMadon for In we.rune 6 no•n mfy by ICC IBM ' Ewlomlon SerWw LLC erpn on plied,m to anyfhding or olhermanerin Ihls eepod,germ fa myprod6a—.d by the raPon. WE - CopyrigM 0 2016 ICC Evaluadan Service,LLC.AN dghts reserved. Page 1 of s VAR-1012 j Most Widely Accepted and Trusted Page 2 of 6 Sheathing as described in ESR-1474 with a layer of 6.2 ICC-ES EC114. [Evaluation applies to IgCC Section maximum 1-inch-thick (25.4 mm) rigid foam plastic 505.2.5;CALGreen Section A5.405.1;ICC 700-2008 insulation laminated to the interior face with PVA adhesive. Section 608.1; ICC 700-2012 Sections 609.1, Refer to ESR-3373 for additional product description. 11.609.1•& 12.1(A).609.1; LEED Homes MR 2.2(c); 4.0 CONDITIONS LEED v4 Homes MRc3; LEED NC MR 5; LEED Schools MR 5;LEED v4 BD+C MRc3;ANSI/GBI 01- 4.1 Code Compliance: 2010 Section 10.1.4.11. AdvanTech® (AT-Series) Sheathin% Span, AdvanTech® S.3 ICC-ES EC108 [Evaluation applies to IgCC Section (AT-Series)Floor Span,ZIP System Roof Sheathing,ZIP 806.1;ICC 700-2008 Section 901.4(6);ICC 700-2012 System®Wall Sheathing and ZIP System® R-Sheathing Sections 901.4(6)& 11.901.4(6); LEED NC EQ 4.4; have been evaluated for compliance with the requirements LEED Schools EQ 4.4;LEED v4 BD+C EQc2]. of the International Codes as listed in Table 1 of this report. 6.4 ICC-ES EC109[Evaluation applies to[CC 700-2008 4.2 Green Rating Systems, Standards and Code Section 606.2; ICC 700-2012 Sections 606.2(2), Eligibility.; 11,606.2(2) & 12.1(A).606.2; ANSI/GBI 01-2010 The information presented in Tables 2 through 11 of this Section 10.3.2.11. report provides a matrix of areas of evaluation and 6.5 Documentation establishing and documenting all corresponding limitations andlor additional project-specific major sources of primary manufacturing energy requirements, and offer benefit to individuals who are [Evaluation applies to ICC 700-2008 Section 606.3; assessing eligibility for credits or points. ICC 700-2012 Sections 606.3&11.606.3]. The final interpretation of the specific requirements of the 5.6 ICC-ES ESR-1474 documenting that ZIP System Wall respective green building rating system, standard and/or Sheathing is equivalent to a code-prescribed water- code rests with the developer of that specific rating system resistive barrier [Evaluation applies to CALGreen or standard or the Authority Having Jurisdiction, as Section 5.407.1; ICC 700-2008 Section 602.9; ICC applicable. 700-2012 Section 602.1.8). Compliance with items noted as "Verified Attribute' is 5.7 Refer to ICC-ES ESR-1474 for evaluation of the ZIP subject to any conditions noted in the tables.Decisions on System Wall Sheathing as an air barrier assembly compliance with those items noted as"Eligible for Points" [Evaluation applies to IgCC Section 605.1.2.1.1; ICC in Tables 2 through 11 rests with the user of this report, 700-2008 Section 703.2.1; ICC 700-2012 Sections and those items are subject to the conditions noted.The 701.4.3.2, 11.701.4.3.2 & 12.1.701.4.3.1; LEED user is advised of the project-specific provisions that may Homes EA 3;LEED v4 Homes F-Ac7]. be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this, 6.0 IDENTIFICATION report, Rating systems or standards often provide AdvanTech® (AT-Series) Sheathing Span, AdvanTech® supplemental information as guidance. (AT-Series)Floor Span,ZIP System Roof Sheathing,ZIP 6.0 BASIS OF EVALUATION System® Wail Sheathing and ZIP System®R-Sheathing The information in this report, including the "Verified products are identified with a stamp noting the Attribute,' is based upon the following supporting manufacturer's name(Huber Engineered Woods,LLC)and address,the product name the manufacturing location,the documentation: ICC-ES evaluation report number(if applicable),and the 6.1 ICC-ES EC102 [Evaluation applies to IgCC Section name or logo of the inspection or grading agency. The 505.2.4; CALGreen Sections A4.405.4 & A5.405.7 report subjects are also identified on the product and/or ICC 700-2008 Section 606,1(2); ICC 700-2012 packaging with the VAR Environmental Report number Sections 606.1, 11.606.1 &12.1(A).606.1;ANSI/GBI (VAR-1012)and the[CC-ES SAVE Mark,as applicable. 01-2010 Section 10.1.2.2]. TABLE 1—REFERENCE STANDARD OR EVALUATION REPORT NUMBER FOR HUBER ENGINEERED WOODS LLC PRODUCTS PRODUCT REPORT NUMBER/ REFERENCE STANDARD AdvanTech®(AT-Series)Sheathing Span S - 765 AdvanTech®(AT-Series)Floor Span ZIP System®Roof Sheathing ESR-1473&ESR-2227 ZIP System°Wall Sheathing ESR-1474&ES8-2227 ZIP System'R-Sheathing S€R-33Z3 VAR-1012 I Most Wlt Accepted end Tnrsted Pepe 7 of B TABLES 2 THROUGH ill Zm BymAm 21P swbm saemn Pa.elaa AaomrTom Adw,nro<n zm sret.m Numbm 9ectlan mbnt Painb Cmtlldana of Web CaaelY BA.athNs FMerhp Raul Was RSTestldnp Bhealhmp BheaAm• TABLE 2-SUMMARY OF AREAS OF ELEGIBILITY WITH 20121NTERNA7IONAL GREEN CONSTRUCTION CODE s55A4 B.bbw patluch WA Hubueood prodwteM Wesdedw bbmna6 • • • ■ OB Pradm abs ba rm>T'vlad,ha.MAa t-WBm-hr WWMa 50a Id (BbOmn1 re65m dlFebdOdNp Wh Where any a pammtafe m2edel mprotlud b rewnled,hJresetal,edrwm a mnmrtaavea w»d.s00mhJ(aa0 mnl,any 5=5 Imlp—m.l WA aW pedimi Md b•h"ad Yema rtaamm enVa4Pp Wby a rmr40u O 0 O O ftd bBro b Wlq•5•ahalq dA W dq m@pybp ew nAurb e■tW reePiutleJ uebwepmletl gaam mnl q 6.8,6adRpexl mm�ber W We tllM bamww by mem•dw Ihen nterm nd 6a5.t.21,1 Wuler WmeOdlm, IyA IbarGWdc-■uC.1ea uemowdLn dpa4r PnR ml nronpfmMrmEVWa•ha1Y4wwrM4, X n f U,MaMu mVa9na DlaaMC Pta5fe2h(See l aTtJlobnW l ntaot VlMam(eom Wei WOW. a1 po w • • • • • • O° TABLE S—SUMMARY OF AREAS OF ELEGIBILITY WITH 2017 CALIFORNIA GREEN BUILDING STANDARDS CODE A54ast R Vmly I pWmtnm uoemaea4 Pbxad—month WntthW aplondrr■teM4 cwfm m5W m1w mWn olWe 0.W O O O O law AS..2A4.401 Bleamod matMJh AOlmbaraeod paA°cb Nrfuaslhdw 6bbaeed • • • • Oe F eNn Ma05.451 R■Mntla sauces Nelmla•Rom ieMYaBle tadw leutlfwap'ntteMwao6) • • • • O° A5AMV CL0WVbatl UrdcreNewq CaCaNa BW&VsbnCaltle GPnar•)on• WA WA WA WA WA 1401.1 —4WNWetlmwag-s Y Hater padaaa D'artleewvla*eaUlanl mtnbrwa9am bpa O O 4504.5 BafGaNy e.5w.4.5 CamPasaawca0 podum mNubm E1NP patlucb Da McPpybee mmnwtlevgod pmmM doW■mn' TABLE 4—SUMMARY OF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD(ICC 700.200a) Wde .wsmr mrda uurdrtn hmtd erAtm4wheve buNruWlm MYWepan JAY.mb MpimWrvaxu 1� _T • • .name aoyPee NlPabaeN naWde•ebu ror Toeun BpahOJ taadKb matb dtoau l%o11M mMirufimm•ML mrt 61.1(21 man•en txwmopryat.prq.d.tl brPwimftubep a andm eot.etl pradudntxeimebdtl mdmRt Da waTmspmteM s • • • o• maxdd m■ aveSeBe br eRnasx Taa mmsetlwaadaaoatl prbtluaMwetl mr Ta wm]POVdeaettmpeamneawooe pmaudmutemwueed.J anmmr eaa211J mWorelwimbareu Wadlnx emhwdrwea B mmna' • o • • O°. rornbzf iao prmadamdhbm Prmum u.vmM rewm4wWy...rmwwmn.dwm paaaemum.aoawaw.l.■7m . eae.2121 mawewmmborinebasmnaawAwdaaea 4 aem•R, • • • • D° aealmma ■aWAaY m aAN Im m®hr emrgmarm nitre buafiy aitl en mumWamN uahgcmYihruma 2wm To wrn BpaNb Bu Ptbdaa mwl De wad brdbax3 meJpmmponaNJame Ma 72%arprWury—d.-"l°'•aw•enmsY emaJ bAWbq.2 prime mey beearretlxnw uead ibrwdrma7m wmpawnb • • • • O° deniedlMarowaaldaebuwA mmbw® nvm •amwa m RneareeW.neor emmte o •Eibmera PahVt •Veded W .-Tlb pmhbndwnd wprmgb pmtllA! NaY FaP"'a<w eteloribd aee*Tab`P 1t a i it gC•1pUf PgvPl w fppupo):oPN pnpw gW DI/kids pu wop UQWPAd MALL. Y .iepolol%WBG- O .0 • • ! • »Ood PM.PlIDu.PleWw BurURaNw PwD SAW UVWwWY f l,wpBp.•WPIU uv Wwa'mlwod&cp-N (B)evps IB90)L ene.dea■U--W) p110f3 P 1.mwded vs wq.vwe fW tpwueppll•U 9eegmWePn4RfP�•Pu (11030C'L'LL • • • • • wromwrnWmwlpB•WwPOBYLdp esom%sepwwnww.gWIDw�P ei �10jH� '•"'`�B1°•n.pu.axed oBavae rump tgvtpe{t LIIPu••vepv mm000 •nmtp&%W IIIP'l08 11d 000µpYe{6d 0001We ea{bpa U4WLml. IwLmpuf'OPs'poU iq Dfw pDoWLrPPnoE WEL P•W PWUOfvlw HmdwUW(O gau UL t'Cl't0!'l21 O O _ `.�. A•fUdde C l.0mfPP•w4eMll LTYIUt'll �( m'OuWoBN.W PYYM.Puapwm.W .PW uw q5 D.0 W wr CE'I'{pl ,�wpaw.gw.WWo.+ w.0 uovd foal gaVwoW nfl WL ewgDm.wp Own.p 14A.M7 mwn. O D O O pDNWmw•LBRI{•!gWWW.MI gdlW.0 umi tvgnPod mpgpv..nw pw pL .PgPrw Fina-b Ms Wl.pnpad'Aewm OPbfTsplP lgg oWpgOU!>c.IPpl wPdweo W p Wmt ILDZ7•v0W 0Wl P.PMlBp.yvdvlegP eU•wD(pPp lwtl WU7 PY i005 lUeprylYffWo m'gmPe MPm'wanDPd t IeIA[W NteffA4Dai wm Py •iRap eue spnwwlampm. lWVodww m(eW Wm Pl p.m uwW P°W�u R/wu 4M1odi'•+IDABv f.WB gW fRpmqum'emep..Rnek.wPU CSW'l4 .O • • • • oW pgwWww mfm CtemI WSI P.m e.loco nxw AOW gwvd 0W of Wmi papap/Ulfw mfalU WWWepuew luuwdP C'vW rilt P uvw Wpw a wwm ps�nDgmnw es Bum wpp quwodwa Igwu N p.w wflgigWy f _ laolp ewoV M tllil e0 ■ • • • lq.wo P Pem R oW MU Pwod Pool Mn WPwpu.■lpd"=1 a .1d aW.fPu4nf vW A a NDWg.Awu WrOO9'4L eg p.mwepnpotl waR PonnwVwf+ofy LIL-1 WvWs v 'BUB Y tZL l0 • • • • laq ePpom RmP PVWPwod-PPUwv Puoan.%Awe wol C 14A{PLf Wee e4PUR WIPguw.+puW ({k'BW'll mlwm w ganpod pv.R'poDr DDIPm or.1 I zvm l '14SD UWlpWe ml.ReP,v palNvrw L'WB'tl lZt .0 • • • ! w V*dCatleem RlmW)LealwMWr%IpPp•d Vvle9oR nWwe B BupUR Pewgod MmPlod eWlo%{uiWpDW (gIt'008'LL �e NY ImPswrWvgPwma WIP%4leeel leRlmwepVaqupdBYlmo Iq Wm'm.n wM gepo{aw P.—A -11 tthm • • %:1: rnr'�v.•4:�'',�u i:: wwenmlwlav WM•Wa9bugd IDmMre PY+9 W?Ituntu+v,DgM 'WPWn wm-e 11 GYM (CL0Z-WL O011 OtMONVLS ONI01In0 H33HO 1VNOLLVN 3141 H1dM A1n191O313 30 sv3HV d0 AHtlWWnS-'9 3'ISVI ,! • • • • fynwd sMHDfuw++Dl•Ww•ggnp qBw MpodP%WPuwW7Wtl D Iw�aiW.aPM1 luy WlV+'g and Bu14p— IB7e'I06 (USO1 mow• 7 PVep3 P L.mmde3 av mrymWH eW falgpul �PDPod-OH frewvyyaW puM mµmlw.wiWmfa.CgvW • • • • • P mWEugQR wiw oovM 990p p NB %SS wniwTue paw ay'40rprn yW 6Pwwgeuy Z6 000 P R—l 4B.w� (l7e'me dwBegplm..Wpu 71ew d 000 P.m BSO Sa 000 P.t Ba Zw 540" PW-MA I-'m"✓9 pom P—kd Ie.PPw3 d Ydpt ppWeW uvpoPPon Weaplpnit7 —Et O O C Bupee.A.pW WN✓nNl tZ"COl , '�' `t�^. uSutvopq fWwVBe pwppwavw WUgwlg•Wm.s'puo ugpr.w P P B m6 CVS W nmo awu 04 gg,.lw,.u.,.gpul 1'U0U O O O O wwvB d lwevL (PBnuIWw3)(■OOZ'001OD1)OHVONVISONIOlIno N33HOIVNOLLVN3L .HIVe1ALnISIO3l3d0sv3HVaOAuVmnS-falOWL ■m--wH At,ate qulOd .RWnN pPtelB dq C q IPVH l(1 W1 MV 1wre0ne.nmwo(wvw0 •Ml--d lugul VOBavS nDDe w4e13 dfi Wqp q Ai punuRu0'J LL wDn(HH1 Z smim 9 L•f•ed POl=.L Pus poletaooV UPIM)son ZWVHVA f VAR 1012 I Most Md*Accented and Trusted _ Page 6 of 6 TABLES 2 THROUGH 11 Contlnuetl sttlbn Condltlone of lhpm eu aly/a Pdnb AN.MkV M.anreah 21F°yem°t rm sx.mm 2lp Snbm N.M., SsdonlM.nl p doY ah.adi4p ibmbp 1R».Nmp s1w.MInB RSaoetldnp TABLE 6—SUMMARY OF AREAS OF ELEGIBILITY VATH USGBCS LEED FOR HOMES 2008 T.—u drb—p ]maa m.al q.aL b.leWr aMwn "rt }'- .�u O O EA3 Mkft.dm NT.N.11.1 M.-A..Ppm.b. _9�- - T,. �Ji%Y''.:• MR21 F -bud wplew Maud a: Town ms po4°par oanpmeraw.FSCtsNME WopIml Mced -2 2 x 3 a Erwe—m Wy pabmb.pmartla want w.pa asama...rA aarnpohb rnapwumpm&p..0aa.d,pamoM ertlmanYl.ab¢dMiTin -y MR 22ca) Wenxsawx,aM:<.danam%p a.n°ad� ammb.la>sbn)mue.3.w.mb.aenmpo%(M neld•araWm.olw o 0 0 0 r.' TABLE 7--SUMMARY OF AREAS OF ELEGIBILITY VATH USGBCS LEED v4 HOMES EA.? Ayb(Aed.rl 2nm Toaamla2pdm.m.ed On.blaaWeR1....irMnm to b.dnpoM •2)y.,1�4, D O MR FSG .dropwlvmd Pw mae MM nmilbmamphlorc.Na.dey FSCa USCSC..ppmod&WA[and x x a a a Enhaen.nlaYy pbiwsb pmaua.broG,wala Ss each a'°nb 100 mOm(ln b ml n)offt akmm of (by waW oor llW r O O O O �' Ur', War•;I.arbra.deda r�emMpaeneaddre Bmaa x ° a Opfim7UN wood padutla cerdaMay FSC areSGSC+pprnad.quha.MnQ x 02 EQa L -A vnal.e.b 1 To e.mi p.0 a.e woad am.5 prd....av—.d&duao- • • • • •° larmab realm. TABLE S—SUMMARY OF AREAS OF ELEGIBILRY WITH USGBCS LEED 2009 FOR NEW CONSTRUCTION AND MAJOR RENOVATION MR s1 Repbrel nudanaro llpll olmnlonll 1 To gmlpdNue.produeb Wlera eab.Ced,po.o..ed.m m.mhd-d o O D 0 spo npnim5 am)otmaw roa a mNmwn of tvx IgmeO a�mbl,,.bde>e MR 5.2 Repbnal nirerlab lm%afmNeM) 2 W.T--2pohb ua andnlmm N20le O O O O URI CaN6edwooa ] Ta earn 1 paU.Ipe.M mum 50%(ba.m an mall of woadaa.ad ] ] ] z mob oedNeAb 6Cm .m.nb° ED 4.4 Va.mG%p metrhts 1 Te earn 1 pnM vee Mood aanpAL woad Wp -d h"p noa m 05 ur.s • • • • brngBMYd.reefs. TABLE"UMMARY OF AREAS OF ELEG(BILRY WITH USGBCS LEED 2008 FOR SCHOOLS NEW CONSTRUCTION AND MAJOR RENOVATION MR St Regentl nntadabllp%W mnbla) t oeamlpc•ivee podW.prm.ro.Naae4 pmaeuee.M numdxme.d O O O O soo-1wsbn)alro w w.nwmana 1al°lEy ae•0 a btm maal.b FM RepbnelnNehb120%al mnrul 2 Taam.T.earn2pa.aeuN.mftm ar2plN O O O D MR 7 c af. od 1 E04.4 To wn t pdnl pas woof mmpa.°.Mood proaryn.ad.Ni�p ns9MN un • • • • 0° TABLE 10—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBCS LEED v4 BUILDING DESIGN AND CONSTRUCTION(BD.C( L--o- SrRIIpY1p°I�°�dab-oaVWepaloln.wweod 1 m2 nu]ai paducb ayFSC ar 6aBCeppovad x ] f 1 Ox v� d mrodpm m..mp me aoxdmmenma MRA oplmz ra.7°•^'fib•w wmlwna � WAlmv emma•matedele MA:Elyl.'ebwpdnb .v dm dedbee =TN.pad.im does rol applTmp..pada.+ Nor.Fminan ar.la®MaflaT.bla it f J VAR-10121 Most WldelVAccepted and Tmsted PeRe6of6 TABLES 2 THROUGH 11 CDntlnued 8.cibn pa•.I�b AMmrT.di Adr.nT.eh 71P 47.1an 28 BTr+m 71PSyebm Num<m 6.c8on Imam fanb CaMllbn.q W.laGWlRy fa p.lm. 8h.mhbp Fb=rinp Raef Wa8 Rdhu4drp 6h.M1np 44vvddnp TABLE 11—SUMMARY OF AREAS OF ELEGISILITY WITH ANSUGBI 01.2010—GREEN BUILDING ASSESSMENT PROTOCOL FOR COMMERCIAL BUILDINGS 10.112 Bkomditp jft-edkft n� 1ma. A]h4mm—W pmdw•m.pu.#I de.tft..d I • I • i • • Oe . To mn c.db we produtl.UW.n•m.nbd aennW mb mmabdmd 10.1.11 R�on91IIY hM-M•mnp.eemnHe. 4mn Spd men JbS3 bnTtlb..7e fa.MNmm o/WbIDY=amAfawMn.oftlb O D O O minponete.� 14.7.7.1 CNMedwodf Bmaz Uan1od8CAm na.oiwn6baxd l.odecm t•edg4wme • • • • Oe O =EWaoe bpolf , • =Nml4W.GN.. .=Tlde Jeoffibndou mt.p•Ybtld.ymwt FmtnM.e: rCMl7ggonb regdrW o7lh.rtmrolWvaf mry.Vmder Ch.indCutmYbrotfequ6W bqudBY WrfIo pWG rFmmimrd9e•bneW7IaLFEO700B mlwoeai FSC.xdwMd/mtl br TEED W IemKa.edhttFSC a U6GBGpproYad WUMud Catl W USGBC Nr.Mf a/aJ:prouad yW.bN prtgr.m.. tiGBBC betprd7eain¢edenu alm otnNAW fernlprWueb horwwr4a.pedec revuvn+enb m.arteM/W.rdowbpmpid rRd.meab rdb 'u.dwtm BrpwNane tlE049blEEp Ra4l.Q bquw emCWmNa AYRnaNge Boom lCMeJ dognd rryilR.enpn.medwWdpeau0ameebnF. rEip1HH)roNe.Ym➢q wmaeveaeangbbp Perem�tliM J•neL i rRepbnelnufed.l gfedeU.m WWon pro}tl bglbn prWaed tr/Neem uppn rwm»t WA•NW appEgb. f i ZIP SYSTEM®SHEATHING WITH HARD COAT STUCCO AT BLOCK FOUNDATION WALL- OPTION A H-2 TRADITIONAL HARD-COAT STUCCO INSTALLED IN ACCORDANCE WITH THE LATH MANUFACTURER'S OR THE PORTLAND CEMENT ASSC,(PCA) RECOMMENDATIONS WITH THE MOST ONE LAYER OF WATER-RESISTIVE RESTRICTIVE CONTROLLLINO. VAPOR-PERMEABLE BARRIER WTTH A PERFORMANCE AT LEAST EQUIVALENT TO GRADED BUILDING PAPER. ZIP SYSTEM®SHEATHING' F=i TOP EDGE OF WEEP SCREED TAPED TO WALL SHEATHING WITH ZIP SYSTEMO TAPEOR ADHESIVE BACKED FLASHING. (MUST MEET AAMA 711 OR AC14B) WOOD OR LT.GA. A.. METAL STUDS ADHESIVE BACKED MEMBRANE ",�••:: �• BRIDGE FLASHING CENTERED OVER TRANSITION JOINT(ZIP SYSTEM TAPE MAY BE USED AS THE BRIDGE FLASHING) 0 CODE-APPROVED WEEP SCREED AT BASE OF WALL VERTICAL AND HORIZONTAL CONTROL JOINT'S AS NEEDED. s OESIONER-OF•RECORDTD SPECIFY TYPE AND LOCATION. MASONRY BLOCK WALL `AP SYSTEM®SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO-LAYER UNDERLAYMENT SYSTEM. DRAWING NOT TO SCALE Sales Office:10925 David Taylor Drive <r�SySlP.R7 Suite MEEK(* 300-Charlotte,NC 28262 ENGINEERED SHEATHING&TAPE Telephone:800.933.9220-Www.zipsystem.com WOODS These construction detai s are provided to assist In the installation of ZIP System pro uct s an may not apply to every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details. ZIP SYSTEM®SHEATHING WITH HARD COAT STUCCO AT BLOCK FOUNDATION WALL- OPTION A H-2 WALL ASSEMBLY TRADITIONAL HARD-COAT STUCCO METAL LATH ONE LAYER WATER-RES.BARRIER ZIP SYSTEM®SHEATHING' WOOD OR LT.GA.METAL STUDS TOP EDGE OF WEEP SCREED TAPED TO WALL SHEATHING WITH ZIP SYSTEM®TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AAMA 711 OR AC148) CODE-APPROVED WEEP SCREED AT BASE OF WALL ADHESIVE BACKED MEMBRANE BRIDGE FLASHING CENTERED OVER TRANSITION JOINT(ZIP SYSTEM _ TAPE MAY BE USED AS THE BRIDGE I FLASHING) MASONRY BLOCK WALL _ > LATH \ TOP EDGE OF WEEP SCREED TAPED ' TO WALL SHEATHING WITH ZIP \ N, SYSTEM&TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AAMA 711 OR AC14B) \ TRADITIONAL HARD-COAT STUCCO \ INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S OR THE PORTLAND CEMENT ASSC.(PCA) RECOMMENDATIONS WITH THE MOST 1 RESTRICTIVE CONTROLLLING. ` ONE LAYER OF WATER-RESISTIVE VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO GRADE D BUILDING PAPER / CODE-APPROVED WEEP ; • SCREED AT BASE OF WALL ADHESIVE BACKED MEMBRANE / BRIDGE FLASHING CENTERED OVER TRANSITION JOINT(ZIP SYSTEM TAPE MAY BE USED AS THE BRIDGE FLASHING) MASONRY BLOCK WALL �u�p� 'ZIP SYSTEM®SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF ATWO-LAYER UND eN7'S MNERLAYMPT TO SCALE N z//iY m� Sales Office:10925 David Taylor Drive ENGINEERED �o Suite 300-Chadotte,NC 28262 u ` Wpp05 SHEATHING&TAPE Telephone:800.933.9220-wwwzipsystem.com These construction detal s are prove to ass st In the Installation of ZIP SystemOproduct(s)and may not apply to every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.