Loading...
HomeMy WebLinkAboutProduct Approval (3) i ago 1 V1 L SCS Home I Log In } User Registration Hot Topics ' Submit Surcharge Stats&Facts Publtcatlons I FW Staff} SCS Site Map t unks } Search t Horda rOProduet Approvaly,�yr 7 +1uSIR:Pubnc User i l•Y:r�iulh�a Product ARproval Menu>Product or Aoollcation search>Aoolication List>Application Cetall FL# FL17147-RI Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Huber Engineered Woods LLC Address/Phone/Email 10925 David Taylor Drive Suite 300 Charlotte,NC 28262 (704)548-5442 kurt.koch@huber.com Authorized Signature Kurt Koch kurt.koch@huber.com Technical Representative Ken W.Hix Address/Phone/Email 1446 Hwy 334 Commerce,GA 30530 (706)336-3041 ken.hix@huber.com ' Quality Assurance Representative Walker Campbell Address/Phone/Email 1446 Hwy 334 Commerce,GA 30530 (704)562-1053 walker.campbeil@huber.com Category Structural Components Subcategory Products Introduced as a Result of New Technology Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity ICC Evaluation Service,LLC Quality Assurance Entity ICC Evaluation Service Quality Assurance Contract Expiration Date 10/01/2017 Validated By ICC Evaluation Service,LLC. Certificate of Independence FL17147 RI C01 Certificate or Independence for Evaluation.pdf Referenced Standard and Year(of Standard) Standard Year ICC-Evaluatlon Service AC310 2015 Equivalence of Product Standards Certified By Approved Evaluation Entity FL17147 RI Epuiv AC310.pdf Sections from the Code FILE COPY' https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3 FapillBd... 4/12/2017 _ Yage 2 of 2 Product Approval Method Method i Option C Date Submitted 0813112015 Date Validated 09/16/2015 Date Pending FBC Approval Date Approved 09/20/2015 c Summery of Products FL# Model,Number or Name Description 17147.1 ZIP System(R)Wall Sheathing ZIP System(R)Wall Sheathing Limits of Use installation Instructions Approved for use in"HVHZ:No EL17147 RI IjZIP Sheathina Install Manual-2013.od[ Approved for use outside HVHZ:Yes Verified By:ICC Evaluation Service, LLC Impact Resistant:No Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other:limited to structural aspects of panel F-L17147 RI AE ESR-1474(21.odf FL17147 RI AE ESR1474.pdf ' Back Next Contact us:;2601 Blair Stone Road.Tallahassee FL 32399,Phone;850-487-1924 The State.of Florida is an AA(EEO employer.Copyright 2007-2013 State of Florida.::Privacy¢ t m nt:;Accessihility Statement::end statement Under Florida law,email addresses are public records.If you do not want youce-mall address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.139S.*Pursuant to ' Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S,must provide'the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click bare. Product Approval Accepts: - Credit Card Safe https://www.floridabuilding.o'rg/pr/pr_app_dtl.aspx?parain=wGEVXQwtDgvCo3 EapiIlBd... 4/12/2017 t ry 4 [ Ir T r } t ff t Iy F ' S , itr � �tZda 1� } M� t'-�i 5 3" y ..,._. ....... . .. . y%i t?jtE•fi.�, �'.r.£�« ,�,,,4�K���f�yls'`.�Y ii w r i t xi�� ';��'� 'ra ��• '3'nT1� rsF•�. �.� � shy� XNApsystem ���`� y .r1, ,Li'�;�t���c'e� +�''.r� >"3 TA4 4 rr ? n }1,?S1- x �,n J+ +y ;2 •`"F �2s .% ,ywaa"'{'«'a°�p"'"..w 5 _ "FF,,F'i ROOF& WALL SHFATHINO FASTER.TIGHTER.ENERGY EFFICIENT. } I FJ 3 .,} i ht m- Ir ; CREATORSGF HavanTech1� Mif � {F z.h__.:',�.5 ry^" ,.a"'p f....'{f Ski Ham: •/ 'Syaya`�-..: 7f+. `S��G'"'«C.�`Y'�i'�9k3a��r:1>. �,yh,' Q`nr"e... l.,i Ii� 5 .4•+ c.7rV `y ,, «,. `ty.s'i:,T'�r.�. k l 'z•-z a <. d'3 w.SS , ''�g =� ' -w..�,`y.':7�d'k'1- `� •%(C.t23 w,.WaN ,f f .•„ t9 w� �r{ ����.��„x�...�r�.,,•fir...:•`tYY.r`sL""'L,rk,�r, v;*'Ld ,.r.�. ".•'.3��U i. 'Z`l.. + � '7 f :,f��. .,�'` ;a M�•z� � i��;,y i+4di ri�' b-�r. ''X YSt+'�Sx $,i�F hxw + fl '; C*r �.'�-;�` }j«, '{� �..•L'{� + s,,fir,� t 'z1 u5•.Ne Qi•�,�a'4 fi�.r � '�fP14S. `•�� n �Sf'C [� .,aq i R.�{ ay 4� V;� Qn S t I'7'�-f+`C.,t-L f?".s4. -..�"F•�• K ', i�2T.« .Y�� e viz +.4h�' \�. np.ta 'K+v t. � `f p��„;r�4 �,�,�[ k7 8 .LF .,� � 7"f :1,?�jp�' ,' , 1 G a. '� �� t :,� ,�.t �` � x>• �`� b.kz: a. �- i E ,,� t}Y�T A. IN , , yc 1II•,•1io �.'<''f•.'' pT#�F"' S " � �'fE. y-3• ` r� O ,cr r f rs f-c '� shA r/ ' '..=aa i'�s' Kh Z � ty r',Ftix,�-,I•'4-Y" p.''a •�ry'P'. yY .a, t ���'.. �F:1�c , S %tj f�n�"'t I hy'-`'Y c'h`.�,r,$..,ry,�s•„ca:'.f?.y�Yi 3M1sy'.s.a`^✓c,p{b_.T rw,.f*t.�1e..j,�...,:.n t arJ,�7,``iF.�}}.t.G-r dr-p t.:'t.tt-4�V"�r_k'-,.r>__i,..:".,-crSt'.•"}.F n}"i,�.�ti1'y-3.1,'rt�+.tyt i-".{�'r,r.3,v Er.�k.i',•Lp.`',ty4"l..'3.xzF:r♦Mt�r.r t'.-?�)'I.i,j�f3e�..-,R,'�`;f"aC`,3z���'F+x'.MtiF'3S S:�T-.�r.-r�f'a i r+'eT,7i..-.«.-i..g'1t-,'S'�w.�,4x";}..rr'�`f"5ai l'.�Y��.�sf1.L+'F+;41'v c t�N.zT.-'E�4n,4 SyA y,t7'r.�:�'`t6S T?i.c`.`.,;.Y y''i�'>Sxy�.j.5.a.'.t�3a-s)'rtiq�i e E-.1<T'iM>e C`i,�G3X••r,r•.ars�s,£f'y�Ly?"F RF`com`'y:h..esrf t 7�f'�,,''.'4:,Ii-jex(k:^.3,:ei53•�iteyF"tJ`'f 6yFry�t�f'3Si".t, "AN y fa t ` s-5r "�' F rkr3:�F z4s.rs ex Yi'4.a'-t f".'.ih t;�fY".;�f,�}"v".'x•�ts'',�IL[3c!�<`,.��'fz.;.4+b+Et's"sr`>"a}i;t.. .. a., a1r =fi+-. :..-" n".s L kk L t.�z:it. w x.2 , 'x•,. 44'} l{ •?"i ,t< } 3 t T S+ L t�+'� :�'"=jc>"�i'�W��'�,�`��[� .�d�.n� ,�?.5�` ��rx[.'�>s..i '�7c4`K"C r1,���S.o£•,�rT 'i�f-,. "rlt,��S� �, sue"; ^nr^t "�,' F c r -s E 1£t � ftl���+'"� udyt��7 �k•2,,.�`'-.r.� e� i p1�� 1.-: f Z;.+ `'v�f�S�-E L ""� �t f�'�'r'>'�ra`�t �s+ `� .t.:���x �C. r- 3 L-�b..G'��.L�i,,..�,-�.! �..J,� 4 > i.�` r�.�'F. � +I ,; L�,.f �4�-.I y' ,� �y t'r,tta x;. t`1,r �,..� ,S. .i,�.y,a+a..r.{ ya�h>�.f 4y-+.• .zi.J} xr--J r 4`-h ;>.-•, A.4•L..h.M ,rt?L..,.;TP 7idl ' a,_.._,_: <� .:�_:a+ .,�....:. f Q �..::L"..�.�"` �., 4 ``k��w--,..�x-^"ti l'>s' � .r Y � t✓✓ --. x h�S r s y �_..t�` y a� r J+r � �n�, .rr i•'C .. ZIP System°Roof & Wall Sheathing x1lisysteeINSTALLATION MANUAL ROOF 6 WALL SMFAnfING FASTER.TIGHTER. ENERGY EFFICIENT. Contents 02 ZIP System® Sheathing Installation On Roofs 08 ZIP System®Roof&Wall Sheathing-Window Installation Flanged Windows&Brick Mould Windows 03 ZIP System`"Tape Installation - Roof Panel Seams 09 ZIP SystemO Roof&Wall Sheathing - Window Installation Brick Mould Windows (continued) 04 ZIP System'" Tape installation - Roof Panel Seams (continued) 10 ZIP System®Roof & Wali Sheathing - Penetration Openings 05 Roof Covering Installation Instructions 11 ZiP SystemO Roof &Wall Sheathing 06 ZIP System" Roof& Wall Sheathing installation Installation Details 07 ZIP System'm Tape Installation - Panel Seams 12 ZIP System®Roof &Wall Sheathing Installation Details (continued) ATTENTION:This Installation guide is Intended to provide general ZIP System Roof&Wall sheathing can be used with a range of exterior Information for the designer and end user.The following guidelines claddings and roof coverings. Approved wall coverings include brick, will help you safely and properly install the ZIP System"Roof&Wall vinyl, stone,wood fiber cement, wood and cedar shakes, traditional hard wall sheathing.We urge you,and anyone installing this product,to coat stucco and specified drainable EIFS applications, however it is read these guidelines in order to minimize any risk of safety hazards not recommended for use with adhesively attached EIFS. Approved roof and to prevent voiding any applicable warranties. This manual Is coverings include asphalt-fiberglass shingles,metal tiles and panels,clay and a general installation guide and does not cover every installation concrete tiles, slate and slate-type shingles and wood shakes and shingles. condition. Proper installation shall be deemed to mean the most Follow all cladding and roof covering manufacturers installation instructions. restrictive requirement specified by Huber Engineered Woods (HEW), local building code, engineer or architect of record or other authority ZIP System Roof &Wall sheathing can be used on buildings of Type having jurisdiction. You are fully and solely responsible for all safety Ili(Roof Applications ONLY)and Type V construction and construction requirements and code compliance-For additional Information contact permitted under the iRC. Huber Engineered Woods LLC. ZIP System*Root&Wall Sheathing Includes: ZIP SystemO Roof&Well Sheathing Safety Guidelines - ZIP System sheathing panels with built-in moisture barrier with preprinted - Follow all OSHA regulations and any other safety guidelines and safety fastening and tape guides practices during installation and construction. . ZIP System tape - Use approved safety belts anftr harnesses orotherfall protection equipment. Storage and Handling - Install ZIP System panels and tape only in dry conditions and on dry surfaces. Set panel stack on three supports(stickers)to keep off the ground. Do not install in rain,snow,frost or other slippery conditions. - Wear rubber-soled or other high-traction footwear while installing ZIP System - Outdoors,cover panels loosely with waterproof protective material. sheathing in a roof application,Do not wear footwear with wom soles or heels. Anchor covers on top of the stack,but keep away from sides.and bottom to assure good air circulation. Ensure-the roofing surface is free from oil; chemicals,sawdust,dirt, tools, electric cords, air hoses, clothing and anything else that might create a In high etagere environments,cut banding on the panel stack to prevent e tripping hazard, edge damage. - Install temporary toe boards along the ZiP System sheathing roof surface. 21P Systems Roof&Wall Sheathing Notes and Limitations: - Do not use on roofs with slopes less than 2/12. What is ZIP System*Roof&Wall Sheathing? Do not use abutted against general stone or masonry without providing a ZIP System Roof&Wall sheathing is code-recognized as a wood structural minimum of a 1/2"gap. panel,.roofing underlayment (ICC-ES ESR-1473), water-resistive barrier Do not Instal!ZIP.System tape in temperatures less than 20°F and air barrier(ICC-ES ESR-1474). ZIP System Roof & Wall sheathing ZIP System products are not recommended for manufactured housing has a built-in moisture barrier that lots you say good-bye to building paper applications that are built under a federal building code administered by or housewrap on the walls and felt paper on the roof.' Simply install the the U.S.Department of Housing and Urban Development(HUD). panels,tape the seams,and you have a structural wall sheathing,water- Do not use panel edge clips(H-clips)with ZIP System Roof&Wall sheathing resistive barrier and air barrier or a structural roof sheathing and roofing without expressed written approval from Huber Engineered Woods." underlayment all from one product. - Do not use ZIP System tape to permanently seal around circular roof projections(plumbing vents,pipes,curved walls,etc.) Contents (continued) Wall Coverings Wet Blown Cellulose Insulation - ZIP System Roof&Wail sheathing should be covered with the finished - In addition to following manufacturer installation instructlons,we recommend root covering or exterior cladding within 160 days of Installation. a maximum moisture content of the cellulose of less than 25%measured at Finished roof and exterior cladding products should be Installed per the inside surface of the ZIP System panel before closing the wall cavity. the manufacturer's installation instructions. Per the recommendation of the Western Red Cedar Lumber Association Secondary Coatings and the U.S.Forest Products Laboratory,wood siding should be primed Do not apply secondary coatings or treatments to ZIP System Roof&Wall before Installation. sheathing panels with the exception of the following: When original roofing or claddfngs are removed and replaced on existing ZIP - HEW approved fire resistant coatings. Fire resistant coatings must be System sheathing, the roof or wall should be covered with an additional tested and approved by HEW for use with ZIP System panels, roofing underlayment or water resistive barrier prior to Installation of the - Feld applied water-soluble borate Insecticide or fungicide treatments new finished roofing or cladding. applied to the non overlay side of the panel. See technical tip, "Tarmite Treatments on ZIP System Roof&Wall Sheathing,"on zipsystem.com for Note:In cladding systems requiring multiple layers of water-resistive barriers, ' more information. like traditional hard-coat stucco,ZIP System sheathing.is Intended only to Permeable laminated radiant barrier foil or paint.For a radiant barrier foil or replace the first layer. coating to be considered permeable,it must have an applied permeance of five perms or greater as tested by the ASTM E 96 wet cup standard. For a radiant foil, the permeance evaluation would include any adhesive and/or backer used to laminate a foil.For a radiant paintfcoating,the permeance evaluation should be conducted at the applied thickness of the paint/coating. ZIP System Root and Wag sheathing replaces only the first layer in mufti-unde layment systems. Edge support is not required by code with 1/2(MIS span rated)and 518(40N-0 span rated)performance category sheathing if the framing does not exceed 24'o.c. and the total load does not exceed 93 psi for f/2 and 158 psi for 518 performance categories.This is based an U180 deflection criteria for total load. Z!P.SysteO Roof&Wall Sheathing Installation Manual 02 ZIP System®Sheathing Installation on Roofs ' Overview:ZIP System Roof&Wall sheathing Is composed of ZIP System panels and ZIP System seam sealing tape.ZIP Systems Roof&Wall Sheathing panels should be fully installed before the seam searing tape is applied.In general,the 21P System roof sheathing panels should be installed from the lowest point on the roof to the highest It is at the discretion of the installer whether to apply tape from the top down or from the bottom up. However,working from the highest sections of the roof and working down will minimize foot traffic on the tape.The following Installation steps are presented as guidelines and a general outline of the installation process.These are manufacturer installation recommendations—please visit zipsystem,com for a library of flashing and installation details.You are fully and solely responsible for all safety requirements.Good construction and safety practices should be followed at ail times. Step 1. Ensure that the panel surface is dry and clean of any nails,sawdust,or other debris or protrusions prior to installing or walking on the panels. After ensuring compliance with all OSHA and local code safety guidelines, Install ZIP System sheathing panels with the moisture barrier surface facing outside.The long edge(8')should be oriented perpendicular to the framing members,and panels should be Installed with the 4'edge seams staggered a minimum of 24". _ t 1/8"spacing between square edges of all adjacent panels is recommended, in accordance with Industry standards for wood sheathing. (Tongue& e'Panel Edges, 4'Panel Edges Groove panels are designed to self-space and do not require manual spacing on the 8'edges.) I The unique edge profile-is Maintain f/a"space designed to accommodate where 4'edges meet_ incremental panel Unique edge profile is on expansion and does not 5'edges only. require manual gapping along the a'edges. Step 2. Ensure that ZiP System panes span at least three framing members and' a framing member supports the entire 4'edge of the panels. Fasten the ZIP System Roof&Wall sheathing panel to the framing members with code approved fasteners spaced at the appropriate edge and intermediate spacing. It is the responsibility of the general contractor to verify proper fastener type and spacing prior to Installation. - Apply the fasteners 31W from the panel ends and comers. - An ideal installation would be where fastener heads are flush with the panel surface. However,due to variations in materials and limitations on equipment, this may be difficult to achieve In some situations. It Is not required to tape over overdriven fasteners unless the fastener head creates a hole through the entire panel thickness. Please see the technical tip,'Overdriven Fasteners in ZIP System Root and Wall Sheathing,"for more Information. Step 3. Install temporary toe boards as necessary when applying the ZIP System sheathing panels up the slope of the roof planes. r , 03 ZIP System'.Tape installation - Roof Panel Seams Apply ZIP System tape after all ZIP,System Roof&Wall sheathing panels are fully fastened to roof-framing.members.Only ZIP System tape should be used to seal the'seams of ZIP System panels:Ensure that the.panel surfaces are dry and free of any nails,sawdust and other debris,or protrusions.Avoid stepping an tape in high temperature environments.ZIP System tape is a contact tape that requires pressure for an adequate seal. Step 1. Apply ZIP System tape to every vertical and horizontal panel seam. it is at the discretion of the installer whether to apply tape from the top dawn or from the bottom up. However,working from the highest sections of the roof and working down will minimize foot traffic on the tape. Ensure that the tape Is centered over the seam within+1-1/2"to provide adequate coverage and to ensure that wrinkles in the tape are minimized. Ensure that tape lengths are continuous across the 8'horizontal edge of the panels.If splices are unavoidable„create an overlapping splice. of at least 3°.Apply moderate pressure onto the surface of the tape to l ensure a secure bond between the panel and the tape. Use ZIP System tape gun or tape roller to apply pressure to the tape and smooth out any wrinkles. Take special care to remove any voids and/or trapped air at splice areas and T-ioints. Step 2 - For valley areas of framing,we recommend you use 6"wide ZIP System -tape.This tape is wider than panel seam tape and Is designed to give you -optimal protection-in valley areas. Starting from the bottom and working your way up,apply one continuous piece of 6"tape so that the canter of the tape is over the valley seam. - Use the tape gun or tape roller to apply pressure to the tape to ensure proper contact with,the panel and to eliminate any wrinkles that might have occurred in the tape.Take special care to seat tape completely 1 into the valley. { Note: It is important to pay extra attention to valley taping as water is directed toward the valleys during rain events, Self-adhering ice and water barriers may be required by code.ZIP System tape is not considered a replacement for self-adhering Ice and water barriers.Therefore,when self-adhering ice and water barriers are required,they should be Installed In addition to ZiP System tape. Zlp Systems Roof&Wall Sheathing Installation Manual . �4 � • ZIP System"'Tape installation- Roof Panel Seams(continued) ` Step 3. It 6'ZIP System tape is not available,use two continuous pieces of 3.75" ZIP System panel seam tape over the entire length of the valley seam, overlapping the pieces on the valley seam by at least 1". - Starting from the bottom,install the first piece of tape overlapping the valley seam by at least 1". First piece Use the tape gun or tape roller to apply pressure to the tape to ensure of tape proper contact with the panel and to eliminate any wrinkles that might have occurred In the tape, Apply the second piece of tape,overlapping the first piece in the valley seam by 1". Repeat use of the tape gun or roller to make sure the tape is adequately adhered and tightly pressed Into the valley seam. Second piece Note: of tape it is Important to pay extra attention to valley taping as water is directed toward the valleys during rain events. Selfmadhering Ice and water barriers may be required by code.ZIP System tape Is not considered a replacement for self-adhering Ice and water barriers.Therefore,when seltadhering Ice and water _.-.... barriers are required,they should be installed In addition to ZIP t'ovedap System tape. Step 4. • - To provide temporary weather protection to rooftwail intersections of dormers or other wood-sheathed projections, apply 2"of the tape width up the vertical projection from where.it intersects with the roof. The remaining tape width can be adhered to the ZIP System roof sheathing panels. Use the tape gun or tape roller to apply pressure to the tape and smooth out any wrinkles. Step 5. Install ZIP System tape over hips and ridges by centering the tape over the peak seam.Apply tape in sufficient length to completely extend the length of the hip or ridge. Starting from the lowest point of the hip and•working up,press tape into Place keeping tape centered over the hip.Apply moderate pressure onto the surface of the tape to ensure a secure bond between the panel and the tape. Cut ridge tape as required for ventilation prior to installing ridge vent Step 6., Tape over toe board nail holes once the toe boards are removed,working from the highest toe boards to the lowest. 05 Root Covering Installation Instructions ZIP System Roof&Wall sheathing is a code recognized sheathing andunderlayment and Is approved for use with the following roof coverings: Asphalt-fiberglass Shingles Metal Roofs(shingles and panels) - Clay Tile Concrete Tile - Slate and Slate-type Shingles - Wood Shingles - Wood Shakes When installing roof coverings,follow applicable codes and manufacturer's suggested instructions.Some roof coverings require a slip-sheet in addition to conventional underlayment.Where slip-sheets are required,they should be installed over ZIP System sheathing panels. Note:Visit zipsystem.com for updates and installation details- Asphalt-fiberglass Shingles Apply asphalt shingles directly to ZIP System sheathing.For roofs wlth a slope of 2/12 or greater but less than 4/12,additional underlayment may be required.. Install asphalt-fiberglass shingles according to applicable codes and manufacturer's installation instructions. Metal Roof Coverings Metal roof coverings may be applied to ZIP System sheathing provided that the roof covering manufacturer's installation instructions and applicable codes are followed. Fasteners used to secure the ZIP System Roof&Wall sheathing panels to supporting framing must be compatible with the specific metal roof covering used. Galvanized fasteners shall be used with galvanized roof coverings,aluminum-zinc coated fasteners shall be used with aluminum-zinc coated roof coverings and 300 series stainless steel fasteners shall be used with copper roofs.Stainless steel fasteners are acceptable with all metal roof types. In addition,metal roof flashing shall also be made of a material compatible with the specific metal roof covering used.Apply metal shingles on roofs with slopes of 3112 or greater. Clay and Concrete Tile Roof Coverings ZIP System Roof&Wall sheathing is intended to replace the first layer in a two-layer or multi-layer underlayment system.When installing clay or concrete the roof coverings,follow the installation recommendations of FRSAfrRI 07320.Install the roofs according to applicable codes and manufacturer's installation Instructions. Slate and Slate-type Shingles Apply slate and slate-type shingles on roots%vith slopes of 4/12 or greater,install slate and slate-type shingles according to applicable codes and manufacturer's Installation Instructions. Wood Shingles ZIP System Roof&Wall sheathing is intended to replace the first layer of underlayment required by the IBC and/or the IRC.Additional layers of underlayment may be required by code depending on the local climate. Apply wood shingles on roofs with slopes of 3/12 or greater. Install wood shingles according to applicable codes and manufacturer's installation instructions. Wood Shakes ZIP System Root&Wail sheathing is intended to replace the first layer of underlayment required by the IBC and/or the iRC.Additional layers of underlayment maybe required by code depending on the local climate.ZIP System roof sheathing is not to be construed as a replacement for interlayment.Apply wood shakes on roofs with slopes of 4/12 or greater. Install wood shakes according to applicable codes and manufacturer's installation instructions. .71P System'Roof&Wall Sheathing installation Manual '06 ZiP System"Sheathing Installation on Walls Overview:ZIP System Roof&Wall sheathing Is composed of ZIP System panels and ZIP System seam sealing tape.ZIP System"Aoof&Wall Sheathing panels should be fully installed before the seam sealing tape Is applied.The following Installation steps are presented as a general outline of the Installation process.These are manufacturer installation recommendations—please visit zipsystem.com for a library of flashing and installation details.You are tuliy and solely responsible for all safety requirements.Good constructfan and safety practices should be followed at all times. Step 1. Install ZIP System Roof & Wall sheathing panels positioned with the water-resistive barrier facing outside.The panels may be installed with the tong side of the panel oriented either horizontally or vertically to the framing members.Walls that are designed to resist lateral shear forces and sheathed with wood structurai panels typically require solid framing or blocking behind all panel edges. if oriented horizontally, block horizontal joints If wall is designed for bracing or as a shear wall, 1/8'spacing between square edges of all adjacent panels is recommended in accordance with industry standards for wood sheathing Installation. oi l--d 4' a'Panel Edges Panel Edges 4'Panel Edges 1/8` 118' 1rE' The unique edge profile is Maintain 1/8"space where Maintain 1/8'space designed to accommodate 8'panel edges meet where 4'edges meet, • incremental panel panel edges.Unique edge Unique edge profile is on expansion and does not profile does not provide 8'edges only.' require manual gapping the full 1/8'recommended along the 8'edges.' space in this situation.' Step 2.Fasten the panels to the framing members with code approved fasteners.Space fasteners 6"o.c.along supported edges and 12" o.c.at intermediate supports,unless otherwise specified by local code or the designer of record,it is the responsibility of the general contractor to•:verify proper fastener type and spacing prior to installation.Apply the fasteners 3/8"from the ends and corners. An ideal installation would be where fastener heads are flush with 's the panel surface. However, due to variations in materials and limitations on equipment,this may be difficult to achieve in some situations. it is not required to tape over overdriven fasteners unless the fastener head creates a hole through the entire panel thickness.Please see the technical tip"Overdriven fasteners in Zip System Roof and Wall Sheathing," on zipsystem.com for more information. 07 ZIP System' Tape Installation -Wall Panel Seams Apply ZIP System tape after all ZIP System Root&Wan sheathing panels are fully fastened to wall-framing members.Only ZIP System tape should be used to seal the seams'of ZIP System panels.Ensure that the panel surface Is dry and free of sawdust and dirt prior to taping.ZIP System tape is a contact tape that requires pressure for an adequate seal. Step 1. Tape all seams using ZIP System tape, Ensure that the tape is centered over the seam within +/- 112" to provide adequate coverage and that wrinkles in tape are minimal, Use the ZIP System tape gun or roller to apply pressure to the tape and smooth out any wrinkles. Step 2. Wherever tape splices occur at a horizontal or vertical seam,create an overlapping splice of at least 3'. At T-Joints,the tape pieces should overlap by at least 1.Apply moderate pressure onto the surface of the tape to ensure a secure bond between the panel and the tape. Use the ZIP System tape gun or roller to apply pressure to the tape and smooth out any wrinkles. Take special care to remove any voids and/or trapped air at splice areas and T-joints. Step 3.Tape inside and outside corner seams. Inslde comer seam JOutside comer seam Note:Tape over any areas of the panel or tape that are damaged during construction. ZIP Systee Roof&Wall Sheathing installation Manual ®8 ZIPSstem -Window Installation DISCLAIMER:The Wowing steps represent a general.merview for the properinstalladenatwindowflashhg.Please defer to/consult Y the installation instructions of your vMdow manufacturer as well as code requirements in your jurlsdtctian for full installation details. Flanged Windows f. Fasten the ZIP System sheathing 5. Cut a length of ZIP System tape or another to the wood frame and install adhesive-backed flashing tape (must meet ICC- ZIP System tape to all wall panel , ES Acceptance Criteria for Flashing Materials seams, as detailed in sections e° (AC148)) and apply to the header, ensuring that 02 and 03. the flashing overlaps the jamb fiashings.° • Once the tape is in place,use the tape gun or roller f to seal the flashing to the sheathing. ' '00 NOT tape bottom flange. 2. ZIP System tape may be used as pan flashing if 6. From the interior,apply low-pressure polyurethane Installed In accordance with flanged window foam(for.windows)between the rough opening installation details posted on zipsystem.com. and the window frame.(Caulk sealant compatible Other adhesive-based flashing tapes(must meet a with the sill flashing maybe used at the sill it the ICC-ES Acceptance Criteria for Flashing Materials opening between the sill flashing and window (AC148))may be used as pan flashing if installed is too narrow to allow the use of low-pressure per ASTM 2112-07,Apply the flashing to cover I polyurethane foam.) the bottom of the opening,overhanging onto the ` •. ts sheathing by at least 2°and extending a minimum When using ZIP System tape, butyl, 100% silicone or polyurethane sealants are acceptable. ?` ' of 6°up each jamb. p y p Do not use latex sealants with ZIP System tape. If using another flashing tape, follow the flashing _ manufacturer's recommendation in selecting a sealant compatible with that flashing. 3. Apply sealant around inside face of mounting flange. Sealant must be gapped at the sill Brick Mould Windows to permit drainage.Install and level v>tindow per �, 1. Fasten the ZIP System sheathing manufacturers installation instructions. Verity to the wood frame and install - - sealant compatibility with window manufacturer. ZIP System tape to all wall panel When using ZIP System tape as pan flashing, ~ seams, as detailed In sections butyl, 100% silicone or polyurethane sealants 02 and 03. are acceptable.Do not use latex or other water- based sealants. 4. Cut two pieces of ZiP System tape or another 2. If recommended by the window adhesive-backed flashing tape (must meet ICC- manufacturer,cut a strip of wood ES Acceptance Criteria for Flashing Materials ' \ to function as a back dam at the (AC148))and apply to each of the window jamb sill.The wood strip should have flanges, ensuring the jamb(lashings overlap the a length equal to the width of the sill flashing. �� rough opening and a height and width of at least 11Z'.Position the Once the tape is in place,use the tape gun or roller black at the inside edge of the to seal the flashing to the sheathing, window frame. 09 ZIP System -Window Installation DISCLAIMER:The following steps represent a Generef overview for the proporInstallation of window flashing.Please dater to/consult the installation instructions of your window manufacturer as wall as code requirements In your jurisdiclion for full Installation details. • Brick Mould Windows(continued) 3. ZIP System tape may be used as pan flashing if 7. Cut a place of rigid head flashing so that when Installed in accordance with brick mould window installed,it is flush with the edges of the exterior Installation details posted on zipsystem.com. moulding of the window.Apply a bead of sealant Other adhesive•based flashing tapes(must meet to the back and_bottom surface of the rigid ICC-ES Acceptance Criteria for Flashing Materials head flashing.Use sealant recommended by the (AC148))may be used as pan flashing if installed flashing manufacturer. per ASTM 2112-07.Apply the flashing to cover the bottom of the opening,overhanging onto the sheathing by at least 2"and extending a minimum of 6'up each jamb. B. Secure the rigid head flashing to ZIP System wall sheathing. 1 i 4. For vertical jambs,cut ZIP System tape or another adhesive-backed flashing tape (must meet (CC- ES Acceptance Criteria for Flashing Materials �. (AC148))and apply to each of the window Jambs. Ensure that they cover the entire inside of the rough opening as well as overlap onto the sheathing by 9. Cut a length of ZIP System tape or another at least 2 Bashing shall also extend above the �. adhesive-backed flashing tape(must meet(CC-ES rough opening,such that R will project 1"beyond Acceptance Criteria for Flashing Materials(AC148)) the exterior trim of the window. and apply to the rigid head flashing, ensuring Once the tape is in place,use the tape gun or roller that the adhesive-backed flashing overlaps the to seal the flashing to the sheathing. jamb flashings. Once the tape is in place,use the tape gun or roller io seal the flashing to the sheathing. S. Apply sealant to jambs and header allowing for drainage at the sill in accordance with window manufacturer's installation instructions. When 10.From the interior, apply low-pressure polyurethane using ZIP System tape,use a butyl,polyurethane foam(for windows)between the rough opening and _ or 100% silicone sealant. Do not use latex or the window frame. (Caulk sealant compatible with other water-based sealants with ZIP System the sill flashing may be used at the sill if the opening `~ tape.When using another flashing tape,follow the between the sill flashing and window is too narrow 't ' flashingmanufac4urer's recommendations In F' to allow the use of low-pressure polyurethane foam.) selecting a sealant compatible with that flashing. When using ZIP System tape,butyl,100%silicone or polyurethane sealants are acceptable. Do not use latex or other water-based sealants with ZIP System tape. If using another flashing tape, follow 6. Install and level window per manufacturer's the flashing manufacturer's recommendation in Installation instructions. 1, selecting a sealant compatible with that flashing. ZIP System®Roof&Wall Sheathing Installation Manual 10 ZIPSstem - Penetration Openings o1SCLAIMERIThe following slepsrepresema general overview for ihe proper installelfonofpenetratio nflashing.Pleasedefetlo/consult Y your code requirements In your judsdfclicn for full installation detalis. 0 svi EEq WALL VEAWuc WOOD OR LT."S TALSTIICS I.A4NM OAP RE.JJNENCED AT DP SYAL 5�-EMt x,1L19F.AiY7N0 I` •< 1 9nfERWGESLiIESa WCOD CA LT-OA,4TA161L`06 1 : �;«3 r I NL�dv�&OPN.CFiEo a9GEs �. •'$`• f P LESAP ANELEOf.SSCAtESS .� `t4£�., i LP SYSTAL�Tw�'INSTAlAEO a 3, OTHEFri1SE PIICAC'm BY •' OVERALL 1t9N.�WDP SYSTENW 0? WALL 9NFATR\•GL !"'�'�'.. @ wL0/INF:O PR Es i 1r�C�:'�x ^ ��J•�,>`,F `F. t1P SYSTElAO Gi=IM'41ED OVERU TAPER!mWIA OF 1.91CMKf Af1T,'pA1S ONER ALLJCW SN W GI. SYSTEUO !<: ALL EwrWNaL I WRALLZPSYSEEWTAPEATALL OVaRLAPT) A~. JA Ig I EiTES7GR CGR Eas 'i�•. sue• L 1dNCAATALLT.'A0.75 - FASTEN ZS•SYS'rV.A)'J ALL INSTAL-.2IPW5""d TA ATALL I 5!�.1TLCIWL14E 0 EOSY W.ERICA COA• OESNI-R O-A_OORG OR LOCAL sL%DNOGCOEVASM 'sf SH5A DPASA ft ONDR VEZAGN RZFAF�ROCAIY �,y OESIOM CCOE-ECCJIDCP LCC.1L sudOWaccDE + WALL ASSEMBLY WALL ASSEMBLY ' LP SYSTEr�WPL.SHEATFLlNG ZIP SYSTEMII WALL SHEATHING WOOD OR LT.GA METAL STUDS WOOD OR LT.GA METAL STUDS .A f r I 1784NCH GAP RECOLAMFND£DAT j Tie-INCH GAP RECOMMENDED AT PANEL EDGES UNLESS PANEL EDGES UNLESS ; OTHERWISE PROMED BY '$.,, OTHERWISE PROVIDED BY F� •L� %• MACHINED PROALEOGES I ,T<y MACHINED PROFILED EDGES ••ii'f INSTALLZIP SYSTDATAPE OR I Ip"d INSTALL 2IP SYSTEMW TAPE OR ADHESOJE BACKED FLASHING(MUST `"yi��+ ADHESIVE HACKED FLASHING(MUST - MEETAC14M IN SEQUENCE FROM MEETACICS)IN SEQUENCE FROM BOTTOM.SIDES,THEN TOP TO ^y, $i[.N' BOTTOM,SIDES,THEN TOP TO ENSURE SHINGLE LAP OF ADHESIVE i vt. _€ ENSURE SHINGLE LAP OF ADHESIVE !l7yr ✓ SACKED FLASHING ^:`;.,v';,'>,.,�, `. � BACKED FLJLSHING ZIP SYSTWM TAPE QNSTALLEO 'Q$:,r ZIP SYHTEM®TAPE(INSTALLED Yn�S•' OVER ALL JOINTS IN 2IP SYSTE,VS '• ';, OVER ALL JOINTS IN ZIP SYSTEM0 •i:ij ' WALLSHFATHNG). •`�. WALL SHEATHING). :; OVERLAP TAPE A MINONM DP 'y:. OVERLAP TAPS A MINIMUM OF 14NCH AT ALL T-IOWTS 'C+.SA 1.INCHATALLT•JONiS USE FLANGED VENT HOODS ?: Y USE FLANGED ELECTRICAL BOXES OR MEMBRANE F[AS"a J TO PROVIDE FLANGES FOR ELECTRICAL BOXES - ' 11 s ZIP System Sheathing Installation Details on Walls—visit zipsystem.com for more details. WALL ASSEMBLY VINYLMIOODiRSER CEMENT SIDING WALLASSEMBLY BRICK VENEER .''• (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S AIR SPACE(AS PRESCRIBED BY ;•�� INSTALLATION RECOMMENDATIONS) LOCAL BUILDING CODE) ZIP SYSTEM®WALL SHEATHING i ZIP SYSTEM®WALL SHEATHING WOOD OR LT.GA.METAL STUDS J WOOD OR LT,GAL METAL STUDS 1' TOP EDGE OF FLASHING TAPED TO TOP EDGE OF FLASHING TAPED WALL SHEATHING WITH 21P SYSTEMS WITH ZIP SYSTEM TAPE OR TAPE OR ADHESIVE BACKED I ADHESIVE BACKED FLASHING. FLASHING.(MUST MEET AC148) (MUST MEET AC148) CODE APPROVED FLASHING CODE APPROVED BASE l' , FLASHING •` ` FOUNDATION ��;,•, WEEP HOLES(AS PRESCRIBED f,%,•%„��' � / I,% "• BY LOCAL BUILDING CODE) !%:':may:' �••,,,,.• , WAL1 A45fBABLY BRIWALL ASSEMBLY CK VENEER VWYALLED IN ACC CEMENT SIDWD AIR SPACE(AS PRESCRIBED BY (INSTALLED IN ACCORDANCE WDH LOCAL BUM6LT WOE) CLACOIN13MMUFAZTURM ZIP SYSTEMS WALL S-EITHI' INSTALLATION ALL OfEATMN iDNS) WOOD OR LT.GA.METAL STUDS VASYSTEAT®WALL TA1STDJG vwUmT LT.aA METALSTUbs , ' \ ' IIS-INCH GAP RECOMMENDED AT fA1V:CHOAp RECOMMENLW AT r-'ti PANEL EDGES UNLESS \ I-'••1 ' PANEL EDGES UNLESS ,\ .7, /. OTHERWISE PRDUIDED BY O7WRINISAWIMEDEROFILPROD E G MACHINED PROFILED EDGES AUCNINED PROFILED ECGF9 \ �\ ;y^`' \ ..; xr II 1 i t�:._ ,Ili r , • ' i 2PSYSIBOYAPB WSTALLED I •\•, 1 I i LPSYSTE.UaTAPE(INSTA1LEO `•''I� �' \� `s'>-0. 1 DYEN ALLJORTfS INZIP SY6TEM0 1� \ I OVER ALL JOBYfS IN 9PSYSTEMS WALL PMATHGIGL i �. ;'M (i ; WALL SHEATHING}. HN RLA TAPER MR C OF r T i OVERLAP TAPE MINIMUM OF 7-INCH AT ALL TJOINT9 \ 1 IM-INrH GAP RECOWG.NDEDAT \ `\ ` \��\,\• 1!B• PANEL EGGEG UNLESS I WCN GAP RECOMMENDED AT I\ter" OTHERWISE PROUVED BY PANEL EDGES UNLESS MACHINEDPROMM EDGES �•,! OTHERWISE PROVIDED By MAGI WED PROFIUED EDGES FASTEN 21P SYSTEMS WALL 6HEATHWGABREOUIREDBY I FASTEN ZIP SYSTEM®WALL DESIOHER-0Fi1ECCRD01TlOCAL SHEATHING AS REQUIRED BY BOLDING CODE 0ESKWER-0FRECORD OR LOCAL BUILM"CODE Mote:For optimal air leakage reduction,all untaped edges of the panels can be caulked,gaskeited or sealed with a weather stripping material, ZIP System'Root&Wall Sheathing Installation Manual r - t *12 ZIP System Sheathing Installation Details on Walls (continues!). r WALL BEYOND WALL ASSEMBLY BACKDAM PER WINDOW BRICK VENEER MANUFACTURER'S INSTALLATION AIR SPACE(AS PRESCRIBED BY '•.\ ': RECOMMENDATIONS LOCAL BUILDING CODE) ZIP SYSTEM®WALL SHEATHING INSTALL CODE-RECOGNIZED I WOOD OR LT.GA,METAL STUDS .���., SILL/PAN FLASHING IN ROUGH ! OPENING PRIOR TO WINDOW f x,,• INSTALLATION. TOP EDGE OF FLASHING TAPED . WITH ZIP SYSTEMS TAPE OR ADHESIVE BACKED FLASHING. ,� TOP EDGE OF FLASHING TAPED ! ' (MUST MEET AC148) ,4:. WITH ZIP SYSTEMO TAPE OR ADHESIVE BACKED FLASHING. CODE APPROVED FLASHING ' (MUST MEET AC148) WEEPS(AS PRESCRIBED BY WEEPS(AS PRESCRIBED BY LOCAL BUILDING CODE) LOCAL BUILDING CODE) I l�1 CODE APPROVED FLASHING STEEL LINTEL V. INSTALL WINDOW IN I WALL ASSEMBLY • . ACCORDANCE WITH DETAILS I ; BRICK VENEER 24A-24D OR 25A-25D ! AIR SPACE(AS PRESCRIBED BY l LOCAL BUILDING CODE) I ZIP SYSTEM®WALL SHEATHING WALL BEYOND i WOOD OR LT.GA.METAL STUDS WALL ASSEMBLY CODE APPROVED CLADDING (INSTALLED IN ACCORDANCE WITH ; . T CLADDING MANUFACTURER'S ` INSTALLATION RECOMMENDATIONS) EXTERIOR RIGID INSULATION DRAINAGE PLANE(MIN,YB') ZIP SYSTEM®WALL SHEATHING WOOD OR LT.GA.METAL STUDS TOP EDGE OF FLASHING TAPED TO , WALL SHEATHING WITH ZIP SYSTEM® TAPE OR ADHESIVE BACKED i FLASHING. (MUST MEET AC148) I CODE APPROVED FLASHING I - FOUNDATION i' EE ;i Note:For optimal air leakage reduction,all untaped edges of the panels can be caulked,gasketed or sealed with a weather stripping material.