Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (2)
RECEIVED FEB O4. I„ REV1E 'r6R MEMO I etC. CODE C®MpL1AN hcr'st an StreethUnit#13 ST. LUCIE COUNTY oxford,CT06478 (203)262-9245 ENGINEER EVALUATE INEOSINO W CONSULT Boral Roofing Evaluation Report M35710.12.10-R12 757S Irvine Center Drive,Suite 100 FL14317-R11 Irvine,CA.92618 Date of Issuance:12/21/2010 (602)269-2288 File Copy Revision 12:11/25/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7th Edition(2020)Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility locatibn(s). NEW ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: .1 r� r'P.:' Robert J.M.Nieminen,P.E. °y� k;ea;�� a�; The facsimile seal appearing was authorized by Robert �''�S`��'�SL'•�� Nieminen,P.E.on 11/25/2020.This does not serve as an Florida Registration No.59166;Florida OCA ANE1983 ••:.r,.„,,;,,,,`• electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018,NEMO ETC,LLC NNEMOJetc. ROOFING COMPONENT EVALUATION: c• Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance with the following sections of'the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /Conditions of Use set forth herein. r 5ectioti.. Bro a Standard Year' 1504.3.1 Wind resistance UL 1897 2015 1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015 R905.1.1,R905.2.8.2 1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018 TAS 110 Material standard TAS 103 2020 Entity Examination:- Reference Date r ERD(TST 6049) ASTM D1970/D4798 M36790.07.11 09/30/2011 ERD(TST 6049) ASTM D226,D1970 B40380.08.12 08/28/2012 ERD(TST 6049) TAS 103-20(tensile adhesion) C41420.09.12-2 09/11/2012 ERD(TST 6049) ASTM D1970(adhesion) B41940.09.12 09/13/2012 ERD(TST 6049) TAS 103-20(tensile adhesion) B47390.07.14-1 07/31/2014 ERD(TST 6049) TAS 103-20(tensile adhesion) B47390.09.14 09/04/2014 OC(PDM1838) Physical Properties Equivalency statement 11/02/2017 PRI(TST 5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010 PRI(TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010 PRI(TST 5878) TAS 103-20(tensile adhesion) NEI-046-02-01REV 12/17/2010 PRI(TST 5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011 PRI(TST 5878) ASTM D1970 NEI-034-02-02. 01/29/2013 PRI(TST 5878) Wind Uplift BORR-001-02-01 03/17/2015 PRI(TST 5878) Wind Uplift BORR-005-02-01 06/24/2015 PRI(TST 5878) TAS 103-20(tensile adhesion) DAPF-002-02-01 03/08/2018 PRI(TST 5878) ASTM D1970(adhesion) OCF-443-02-01 10/11/2018 UL,LLC.(QUA 9625) Quality Assurance Service Confirmation 08/21/2017 UL,LLC.(QUA 9625) Quality Assurance Florida BCIS Current Product sj Descflpton 4.1 Boral®TileSeal 50"T ASTM D1970 Brentwood, nominal 50-mil thick,polyester-surfaced,self-adhering SBS NH modified bitumen roof underlayment 4.2 Boral®TileSeall ASTM D1970 and Brentwood, nominal 60-mil thick,polyester-surfaced,self-adhering SBS FRSA/TRI 09-18 NH modified bitumen roof underlayment 4.3 Boral®MetalSeal"T ASTM D1970 and Brentwood, nominal 60-mil thick,polyester-surfaced,self-adhering SBS FRSA/TRI 09-18 NH modified bitumen roof underlayment 4.4 GatorSeal® ASTM D1970 Brentwood, nominal 55-mil thick,granule-surfaced,fiberglass reinforced, NH self-adhering SBS modified bitumen roof underlayment 4.5 Citadel°Plus ASTM D1970 Brentwood, nominal 48-mil thick,fabric-surfaced,fiberglass reinforced, NH self-adhering SBS modified bitumen roofing underlayment for use as a base-layer in multi-ply underlayment systems MEMO ETC,LLC Evaluation Report M35710.12.10-R12 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R11 Boral Roof Underlayments;(602)269-2288 Revision 12:11125/2020 Page 2 of 6 I � ONEMOJeft. 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by-itself beneath the stated roof covers. Refer to the installation instructions for multi-ply underlayment options. - �' j TABLE 1. ROQF CovRlt OgtIQNS ' 4 FACSec#dne 1507:2 15Q73 1507.4&15Q7.5 .1507,7 -507.8&150ZSQ ;Clay and Concrete iite Metal Slate or Wood Underlayment Asphalt Shingles Mechanical Adhasnie- Slate4ype' Attac.F► Panels Shingles Shingles Shingles&Shakes Boral TileSeal 50"T Yes No No Yes Yes Yes Yes (joint strips,1507.1.1.3/R905.1.1.3) oral TileSeal" Yes Yes Yes Yes Yes Yes Yes (See 5.6.1) (Joint strips,1507.1.1.3/R905.1.1.3) Boral MetalSeal"T Yes Yes Yes Yes Yes Yes Yes (See 5.6.1) Uoint strips,1507.1.1.3I R905.1.1.3) GatorSeal Yes No No No No Yes Yes Qointstrips,1507.1.1.3/R905.1.1.3) 5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations. - ;:" ,,. *TABLE-1A,ALLOUIfABLF(JNbERLA�IMEN7�TiLE A13I�651VE CQMB1NA710N5 UndePlayment. Adhesive Flonda:Product_ Approval. Boral TileSeal"Tor Boral MetalSeal"T DAP Foam`Touch'n Seal Storm Bond Roof Tile Adhesive" FL14506 Boral TileSeal"r or Boral MetalSeal"T DAP Foam`Touch`n Seal Storm Bond 2 Two-Component FL21374 Polyurethane Roof Tile Adhesive" Boral TileSeal"T or Boral MetalSeal"T Dupont"Tile Bond'""Roof Tile Adhesive" FL22525 Boral TileSeall or Boral MetalSeal"T ICP Adhesives and Sealants"Polyset°AH-160" FL6332 Boral TIIeSeal"T or Boral MetalSeal"T ICP Adhesives and Sealants"Polyset®RTA-1" FL6276 1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC Evaluation Report M35710.12.10-R12 Certificate of Authorization N32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-RII Boral Roof Underlayments,(602)269-2288 Revision 12:11/2S/2020 Page 3 of 6 r � ONEMOletc. 5.7 Allowable Substrates: TABLE 2';5Uf15TRArE OP#ION$FOR ApHEREC1;UNpERLAYMENIS Underlayment ApplicaLorr Primer Substrates (Optional)ASTM D41 plywood Citadel Plus,Boral TileSeal HT or atororal self-adhering none ASTM D226 Type II felt or Citadel Plus TileSeal ,Boral MetalSeal or GatorSeal ASTM D41 metal(flashing metal,valley metal,etc.) Boral TileSeal"T,Boral MetalSealw self-adhering (Optional)ASTM D41 OSB Boral TileSeal"T self-adhering (Optional)ASTM D41 Huber"Zip Deck" None G-P Gypsum"DensDeck Prime" 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions,but not less than Section 5.8.3 herein. 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has-already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition, Appendix A,Table 1A or the critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure=-120.0 post: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)ASTM D41 to the plywood deck Base Ply: Citadel Plus,self-adhered Cap Ply: Boral T)IeSeal"T or Boral MetalSeal";self-adhered,and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure=-142.5 Psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: None Cap Ply: Boral TileSeal"T or Boral MetalSeal",self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-202.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Tropical Roofing Products#410 Quick Dry Primer or other ASTM D41 primer to the plywood deck Base Ply: None Cap Ply: Boral TileSeal"T or Boral MetalSeal"T,self-adhered,and back-nailed within the selvedge-edge side laps using 12 ga,x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. MEMO ETC,LLC Evaluation Report M35710.12.10-R12 Certificate of Authorization#32455 1T"EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R11 Boral Roof Underlaytnents;(602)269-2288 Revision 12,11/25/2020 Page 4 of 6 ONEMOJetc. #4 Maximum Design Pressure=-210.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: KARNAK#89 Sta-Tak Primer to the plywood deck Base Ply: None Cap Ply: Boral TileSeal"T or Boral MetalSeal"T,self-adhered,and back-nailed within the selvedge-edge side laps using 12 ga.x 1'/a"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure=-120.0 psf: Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional)Citadel Plus,self-adhered Cap Ply: Boral TileSeal"T or Boral MetalSeal"T,self-adhered #6 All other direct-deck, adhered underlayment systems beneath the roof systems carry a Maximum Design Pressure of-45 psf. 5.9 Exposure Limitations: { TABLE 3 �XPQSURE'CIMITATtONS ` Maximurn llrtderlaynaenc Prepared:Roof Cover lnstallati6hType Exposure (days) ._ GatorSeal Mechanically attached 30 Boral TileSeal 501 Mechanically attached 180 Adhesive-set tile roofs stem 30 Boral TileSeal"Tor Boral MetalSeal"T y Mechanically attached 180 Citadel Plus(base ply in multi-ply underlayment systems only) NSA 180 (prior to placement of subsequent underlayment) 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TA$LE42 fILE$LJPPRGI IN)1tA3CC1NStbRDIRCTi) CK7tCEItNSTALtATipiV5 Underlayment* Tile;P.r,9 le'. 5.taging.Metliod Maximum:5lope Boral TileSeal"T or Boral MetalSeal"T Flat or Lugged Max.10-tile stack 6:12 6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Boral TileSeal 5bN7 or GatnrSeal 6.3.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. When installed over a mechanically attached,FBC Approved ASTM D226 Type II felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. NEW ETC,LLC Evaluation Report M35710.12.10-R12 Certificate of Authorization✓✓32455 f"EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R11 Boral Roof Underlayments;(602)269-2288 Revision 12:11/25/2020 Page 5 of 6 ` / O ` ���MOUetc. 63.2 One or two p|ks of Citadel Plus followed by Qmra| TileSeo 50"T or GatorSeal is allowable for use under ' mechanically attached, non-tile prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a multi-ply underlayment system is desired. 6.4.1 Non-Tile Applications: Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in FBC 1507.1.1.1or1S§7.1.1.3orF8C0om\dmh*|m|R9MS.1.1.1orR905.1.1,3 for the type of prepared roof covering tobe installed,and the manufacturer's installation instructions. When installed over a mechanically attached,FBC Approved ASTM D226 Type 11 felt,the felt shall be fastened in accordance with F8C1G07'1'1orR905'1'1. 6.4.2 Tile Applications: Shall be installed in compliance with requirements for a Self-Adhered Membrane in the F@SA/yRl Florida High N8n6 Concrete and Clay Roof Tile bato&odon Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section S.8.2 for attachment limitations. Refer tu Table 4 for tile staging limitations. 6.4.3 Multi-Ply Underlayment Systems: One or two plies of Citadel Plus followed by 0wnmlTUoSmaIHnor Bunol hAeta|SemlH« is allowable for use under . prepared roof systems. Limits of use are those associated with thetop'|ayer material. This is not a requirement,but is allowable if a multi-ply underlayment system is desired. Refer to Section 5.8.2 for use of Citadel Plus asa base ply membrane inundar|aynnent systems for use under ti|a' mof.sys ems. NEW A As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. -END OF EVALUATION REPORT- � � msmo ETC,ac Evaluation Report M35710.12.10-Rz2 Certificate ofxuth"uzatfo,w32m5 7H Ennmm(2ozo)mcmnm-HvxzEVALUATION m14317*z oora/Roof uxue*avmemq(6oa)26e-228 Revision zc'zz/2s/2uzn Page sn,6