EVAt,UATiON REPORT
STo LUCIE C®lJf TIAX'�Z°3f 26"' .
East Coast Metals,inc. BID C valuation Report E10240.08.08-R4
2301 West 8 Lane F15374-R4
Hialeah,FL 33010 Date of Issuance:09/03/2008
Revision 4:03/17/2015
SCOPE: a
This Evaluation Report is issued under Rule 61020-3 and the.applicable rules and,t �a&"ng the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described
herein have been evaluated for compliance with the P Edition(2014)Florida Building Code sections noted herein.
DESCRiprici N: East Coast Metals Channel Metals
LAsEmye. Labeling shalt be In accordance with the requirements the Accredited Quality Assurance Agency noted herein.
ConfintuEn Compumvcm This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
AOvERTIsEmEwT.- The Evaluation Report number preceded by the words "Trinity(ERD Evaluated" may be displayed In
advertising literature. if any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
iNSPEcnON:Upon request,a copy of this entire Evaluation Report shalt be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
ua%pnf,,►-
.�`'�'sS
r,,:....ti, ;
$Q •,, ... 2 is
+� '�'&`i..."�t�c \+ tlat� '�tm8emralsOltmtlnEctssadhOtited by AOI7P7t iJI@lAMP4
Robert J.M.Nieminen,P.E. '� d,�Sg ,= re amm�Tnrss�daaan�uos�" a�,s�ur9e�a
Florida Registrodan No.59166,RaddaDCAANE1983 ;?y J�.7+L,t4�,.�• aoanaaw s�aa.a�radi�iaeoa�cesvaaee,s afurr�ieatothe
'r`� voauaApprmindmh3nrarerssaco�neromedeoene
CERTIFICATION OF►NDMI)ENCE:
1. Trinity{ERD does not have,nor does it intend to acquire or will it acquire,a financial interest In any company manufacturing or
distributing products it evaluates_
2. Tdnityl ERD is not owned,operated or controlled by any company manufacturing ordistributing products It evaluates.
3. Robert NiemineN P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E..does not have,nor will acquire,a financial Interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Wri tyl ERD nor Robert Nieminen,P.E.are,In any way,the Designer of Record for any
project an which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
Reviewed For
Code Compliance
141A�yrlPiShdP,y{2ak.Pi
01/22/2019
L
ROOFING C0MPON r EVALUATION:
L SmPE:
Product Category: Roofing
Sub-Category: Roofing Accessories that are an integral Part of the Roofing System
Compffance Statement: East Coast Metals Channel Metals,as produced by fast Coast Metals,have demonstrated compliance
with the following sections of the Florida Building Code through Ong in accordance with the foliowingStandards. Compliance
is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
.2. STANDARDS:
Sectlan Prone Pronerty atandard year
B073.7 installation,non-tim FRSA/M April 2012 iO4-12) 2012
1518.8.1 Installation,HM RAS 118,119&110 1995
1523.63.L2 StaticUpliftResionae TAS101 1995
17IL21 Statk Uplift Resistance SBM SSM 11 1997
3. REFEREIYCFS:
FriftExaamination rence Date
ERD(iS MO) Static Uplift Resistance E42730J3M 08/23/20Z3
ERD(TST6049) Static Up6RResistance ECI M67795.3 %4-1 02/27/2015
ERD(73'WO) SladcUPWRestst = ECWSCGM-'2.24-2 02n7/2015
F1cddaTECCMr7393) TAS101 S10.628R 10127/2010
PRI(rS13878) TAS 101 ECM-001-13z-01 09/22/2001
PRI(13T5878) TAS 101 EtM-003.02-01 0611312COS
PRI(TST587M) TAS 101 ECM-004-02-01 06/13/2008
PRI(TS5878) TAS 101 ECM OSM-01 06h312008
PRI(TSf M) TAS 101 EavWa .OZ-01 06/3/2008
PRI(TST5878) TAS 101 ECM-007-02-01 06/2312008
PRI(TST'S878) TAS 101 Eml-0064M �6/y9/20OB
Florida Building Code AttadtmentRequirements FRSA/fRiA�i't1301*(0 12j� Oq"
Florida Building Code-HVHZ AttachmentRequImments RAS MITL9 and 120 1995
East coast metals Metal Quality ficatrons Varftws
Amhitechtral Testing(QUA3844) Quality Control /elT-
designedrtit3pation Letter ti. Exp.12/31i20i8
4. PRODIR:r�cionoN:
4.1 Hip &Ridge Channel Metal: Pre formed metal cha for use as a hip and ridge base to which roo lies
are bonded in FBC Approved rooftile adhesive. t
Hip&Ridge Channel Metal is available in 114.3/ -inch L
3/8-Inch)length by Z%3,35,4,5,6 or Nnch + /8-inch)
heights with IS-Inch(+1/16-inch)deck-flanges. -
r�v
"oxterier Research and Design,LLC. Evaluation ReportES0aA0.08.0a-R4
Cerd/rmre o/audwrkadae A9S0B 90374•R4
tReOftn 4:03/17/2015
Paget of 7
T ERD
4.2 Trim Lock Channel Metal: Pre-formed metal channel
designed for use as a hip and ridge base to which roof tiles
are banded In FBC Approved roof the adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying the adhesive.
Trim Lock Channel Metal is available in 3I9-3/8-inch L
3/8")length by 3,.3S,'4,5 or 6-inch(±3/8-inch)heights
with 1.S-inch L 1/16-Inch)deck-flanges.
I
4.2 Trim Lock Plus Channel Metal:Preformed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof 81e adhesive. Tdm Lack
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive f
and allow for interlock with the overlying the adhesive
and its perforated deck flanges,designed for installation
atop the roof underiayment via placement In FBC `'p
Approved roof tile adhesive, which flows-through and
Interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal Is available In 119 3/8-inch
(±3/84)length by 3,3.5,4,S or 64nch(^3/8-inch)heights ,
with LS-inch(±1/16dnth)deck-flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
> Galvanized Steel- Min.0.019±0.00210ch,ASTM A653(6-90),ruin.33 KSL
> Galvalume Steep Min.0.019±0.002 inch,ASTM A792,ABS,min.35 KSL
> Aluminum: Min.0.032±0.002-Inch,ASTM B209,3003-H14,min.21 KSL
> Stainless Steel• Mirl.0.019±0.002-inch,ASTM A240/A48D,7304,min.35 KSi.
S. LiMrrAno►vs:
5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen,P.E.are,in any way,the Designer of
Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design,LLG fvabation ReportE10240.08.W114
osrtljlco�ojaaumiraerwra9sa3 FL5374-114
Revision 4:03117PAlS
Pago3 of 7
TPJNITY-IRD
5.2 FOR HVHZJURISOICRONS,.
5.2.1 For Hip&Ridge Channel Metal or Trim Leek Channel Metal, refer to FRC RAS U&Drawing 13, Detail 3;RAS 319,
Drawing U, Detail 3;or RAS 120,Drawing 15,Detail 3. For Trim Lack Plus Channel Metal,refer to the installation
instructions herein.
S.22 For HVHZ jurisdictions,Installations of Hip&Ridge Channel Metal and Trim Lock are prescriptive by RAS 128,119 and
12D,and the data in Tables 1A and 18 is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance(Mj or uplift resistance(Fj,
as determined in accordance with RAS 127,notgreater than the fnilowing.values.
Refertoo the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
>r °INDEPENDENT'paddy placement means each individual trle is bonded to the Channel Metal In its own,single
foam paddy; the head laps are not bonded. This method Is limited to 2-pert the adhesives. Allowable
performance data below for"INDEPENDENT"paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
➢ "INTERDEPENDENT"paddy placement means each individual the is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the the head lap,or two;tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for"INTERDEPENDENT`paddy placement already has a 4 to].
margin of safety applied to ultimate performance.
TA=JA:Plaii;aaa mm li wArm-HVH2,Wasaelcn m PADDY Ptaceu w
(2tt 1 MAK6TAtOF5AFFJTALAbCONAPFLFD)
Hy(Aid emetal Adhesive, Altamble Performance.
O�gn MetdlType Tile Two Placement Moment Based Upil tBased
Mr(ft Ib F
Hip&Ridge galvanized day or 3M"'2 Component Foam Independent 127 169
Channel Metal concrete RoofTile Adhesive AH160-
Trim Ludt galvanized.GarvalumeP. day er 3N1"2-Component Foam Independent 171 159.
aluminum or stalnless steel concrete Roof TUe Adhesive AH-160
Trim4odtPhts galvanizad,Galvalume°, day or 3M'"2-MmponentFoam dependent 177 365
aluminum orstainlesssteel concrete Roof'CileAdhesiveAH:_1
TADMO:PISri MM M UWArrows-HVM 101ER WRIDa,�v PON PIMCOONr
(g7osnaasonuoFsaF�rataFaoravpnFa) -
tRpf Ridge Metat Adhesive Allowable Performance
Tile Moment Based Uplift Based
Design MetatType Type Placement Mt(ft(bf) F(Ibf)
Trim Lock orTdm galvanized,Galvatume°, clay or 3M"'2-Component Foam Interdependent 95 88
Lock Plus aluminum orstainlesssteel concrete RoofTile Adhesive AM-160
Trim tack galvanized,Galvalumeo, dayor 3M"Roof Tile Adhesive Interdependent 99 94
stainless steel concrete RTA 1
Trim Lade aluminum:. dayor WmFoam Roof7ile Interdependent 90 84
concrete Adhesive RTA-1
Lock Plus aluminum
Galvalume°, day or SW Foam Roorylle Interdependent 90 84
Tdm aluminum orstarniesssted concrete AdhesnreRTA-1
Trim Lode galvanized,Gaivalume'or dayor TiLE BOND°t Roof ille Interdependent 323 117
staintesssteel concrete Adhesive
Trim Lodi aluminum day or TiLE BOND'°Roof Tlie interdependent 79 73
concrete Adheshra
Trim Lock Plus galvanized,Galvalumea claybr TILE BONG"Roof Ttle interdependent 79 73
aluminum or stainless steel concrete Adhesive
Trim tack gavanhed,Galvalume°or day or Touch'a Seal StormBond Interdependent 146 139
stainless steel concrete Roof Tile Adhesive
• dayor Touch'aSeal Stormeond
Trim Lock Aluemum Interdependent 5B 54
concrete RoofTlle Adhesive
Trim Lock Pius galvanized,Galvalumeg day or WO'n Seal StormBond Interdependent 58 54
aluminumorstainlesssteet concrete Roof Tile Adhesive
Exterior Research and Design,LLC. 9vaivation Report EIO2R0,08.08-R4
dtr6rimee4AuAo&af1dn0 03 F15374-1114
Revtftn 4:03/17J2015
Pap 4of7
TRH ERD
53 FOR NQN-HVHZJURiSDICtIONS:
531 For Hip&Ridge Channel Metal or Trim Lock Channel Metal refer to FASA/1Rf April 201Z(04-12.). For Trim Lock Plus
Channel Metal,refer to the installation instructions herein
53.2 For non-HVHZ,installations are limited to projects having hip and ridge design pressure requirements,determined in
accordance with Table 1A of FRSAITRI April 2012 (04-12), not greater than the following values. Refer to the the
adhesive manufacturees published installation Instructions for adhesive paddy placement details
> "INDEPENDENT°paddy placement means each individual We is bonded to the Channel Metal in its own,single
foam paddy,tile head laps are not bonded. This method Islirnited to 2-part Ile adhesives. This method Is limited
to 2-part Ile adhesives. Allowable performance data below for"INDEPENDENT"paddy placement already has a 2
to i margin of safety applied to ultimate performance.
> "iNTERDEPENDEIM paddy placement means each individual tie is bonded to the Channel Metal In a foam paddy,
and a second foam paddy bonds the Ile head lap,or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for"INTERDEPENDENT'paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TAamF2A:Pa+mmmcELmiratioNs—Notu-HVH4 n c PADDyPrACEMENr
4 r01 MRGN OFSAFFTYAUMMAPKIM)
HiP/Ridge Metal Tile Adhesive Allowable Uplift
Design Metal Type ripe Placement ham]
Hip&Ridge galvanized dayor 3M'"2-Component Foam Roof Independent 169
Channel Metal concrete Tile AdhesiveAH-160
Trim Lack galvanized,Galvalume°,aluminum or dayor 310"2-Component Foam Roof independent 173
stainless steel concrete Site Adhesive AH 160
Trim Lack Plus galvanized,Galvalumeo,aluminum or dayor 3M"'2-Component Foam Roof Independent 178
stainless steel concrete TileAdhesnreAH-160
TAnL E28:P8FGWANMUMrrATPONs--RtoWHVHZ,Irmamowtimr PAooyPPAcEmENr
(47D1 MARGW OPSAF8IYAPREADYAPPirW)
Hip/Ridge Matal Tile .Adhesive Allowable Uplift
Design MetalType Type Placement 44
Trim Led orTrim galvanized,Gaivalumeo,aluminum or day or 3M"'2-Component Foam Roof endeRt 98
Lack Plus stainless steel concrete TlleAdhedveAH-16o
Trim Lock galvanized,GalvalurnO or stainless day or 3M`Foam RoofTileAdhesive Interdependent 110
steel concrete RTA 1
Trim Lodc aluminum dayor 3M"'Foam RoofTile,Adhesive interdependent 93
concrete RTA 1
galvanized,Gaivalume°,aluminum or day or 3101 Foam RoafT le Adhesive
Trim lack Plus, staintesssteel concrete RYA-1 interdependent 93
Trim Ludt galvanized.Galvalumea orstainless dayor TILE BOND"'Roof Tire Adhesive Interdependent 232
sted concrete
Trim Lock aluminum ca y orr TILE BOND"'RoofTileAdhesive Interdependent 82
Trim lock Plus galvanued,Galvatume°atutninum or day or TILE BOND"'Roof Tile Adhesive Interdependent 82
stainless steel concrete
Trim Lock aabianizad•GalvalumeS or stainless day or Touch'n SealStannBand Roof Interdependent 248
steel concrete Tie Adhesive
Trim rock Aluminum day or Touch In Seal StormBand Roof interdependent 61
concrete Tr1eAdhesive
Trim Lock Plus galvanized,GalvalumeP.aluminum or day or Touch In Seal Stormeand Roof Interdependent. '61
stainless steel concrete Tile Adhesive
Wader Rmearelrand JUstga.IlG Ewaivation Repart£10240 08.M114
o afA"UiorrmtTonA9S03 FL5374-R4
Revision 4:03/17/2015
.. ..... ..... - Page5of7•
i
TRINITY ERD
6. IWAIMMTICW:
6.1 The roof deck shall be minimum 15/32-inch plywood(non-HVHZ)or minimum 19/32 inch plywood(HVM attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip&Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min.11 ga.x IX-Inds long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o . along both deck-flanges. Fasteners shall be
positioned Y,4nch from the outside edge of each deckfiange,set in a bed plastic roof cement. For FBC HVW,refer to
FBC RAS 118,Drawing 13,Detail 3,RAS 119,Drawing 12,Detail 3,or RAS no,Drawing 75,Detail 3.
63 Tdm Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of Ile adhesive centered beneath each 1S-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
_ ........i:
� 1
N.
!� r
View of Polyset AH160 Placementfor'Mm Lock Plus Channel Metal Installation
63.1 it is critical that the bond between the Trim Lade Plus Channel Metal,the tie adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
63.2 Approved underlayments are the codified'30/g0'system or other FBC Approved roof underlayments Usting approved
use of the subject the adhesive.
9 mrlorResearchandGesi%UM Evaluation Report E10140.08.08•R4
[erNl7cateo�autl+orlraCon A95G3
FiSS74•R4
Revision 4:03/17/Zo35
fte6of7
TRINTY ERD
6A Tile shall be installed atop the Channel Metal In accordance with the the adhesive manufacturer's Approved,published
installation instructions,subject to the limitations outlined in 5echon S herein. The exposed edges shall be packed and
painted with Approved mortar or weather blocking adhesive'ln accordance with FRSAMI April 2012(04-12)or RAS
118,RAS 119,RAS 220 requirements.
Hip 1 Ridge Tile
"3. " . " Tile Adhesive
:. ® '� � Trim Lock Plus
:� �••"-'' Mortar or Weather Block
•. �--•
Adhesive
.� ., '•• .° ' Tile Adhesive
il,• , , . ,
View of Trim Loch Plus Channel Metal installation after Weather' Tied
6.4.1 Channel Metal shall be free of dust,debris,oils or other bond-breaking substance priorto placement of adhesive.
7. OwLGiNG PERMIT REQUiitmams:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product
S. MANUFACTURING PLANiB:
Contact the named CIA entity for manufacturing facilities covered by FJLC.Rule 61620-3 QA requirements.
9. QuAUTY Assumm ENM:
Architectural Testing,Inc. —QUA180,(717)764-7700
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC Evaluation Report E10240.013.09-114
CirdflmteclAraharha*m 9990 H9374-R4
Revision 4:03/17/2015
Page 7 of
TRINITYIRD
EXTERIOR RESEARCH&DESIGN,I.I.C.
FL CERTIFICATE OF AUTHORr ICIN 49S03
September 6, 2017
RE: East Coast Metals, Inc.
East Coat Metals Channel Metals
4!"Edition (2017) FBC HVHZ
Affirmation of FL5374-R4
To Whom It May Concern:
This letter serves to document that we have reviewed Florida Product Approval File No. FL5374-R4,
and the Evaluation Report which forins the basis thereof,with respect to the 6'Edition(2017)Florida
Building Code,High Velocity Hurricane Zone sections set forth in Section 2 of our Evaluation Report.
There are no changes to the Code that affect the Evaluation Report, and we have authorized the
applicant,East Coast Metals,Inc.,to document compliance with the 6`h Edition(2017) Florida Building
Code„ HVHZ through the Affirmation Process.
Please contact our Connecticut office with any questions.
Respectfully submitted,
Robert Nierninen, P.E.
Vice President
Florida Reg.No.59166
robertniemingnO-)trinigXerd.com
CERTIFICATION OF 1140EMDENCE:
1. Trinity)ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not awned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.