Loading...
HomeMy WebLinkAboutProduct Approval (2) c c SERVICEMost Widely Accepted and Tt"usted ICC EVALUATION ICC-ES Report e e : 11 r WW . r r ..rt'is subjecti6 renewal 1r r DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION:06 16 00—SHEATHING DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 25 00-WATER-RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: 07 27 00—AIR BARRIERS REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE,SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 EVALUATION SUBJECT: ZIP SYSTEM® WALL SHEATHING 1 C ICC . ICC ICC _ PMG LISTED Look for the trusted marks of Conformity! '►== "2014 Recipient of Prestigious Western States Seismic Policy Council ■i , (WSSPC)Award in Excellence" A Subsidiary of CODECOUNCIr ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not PE �"�"d specifically addressed, nor are they.to be construed as an endorsement of the subject of the report or a (\ recommendation for its use. There'is no warranty by ICC Evaluation Service, LLC, express or tmpltec4 as to anyfinding or other matter in this report, or as to any product coveredby the report. mi�ifIV,FI Copyright© 2016 ICC Evaluation Service, LLC. All rights reserved. F ICC EVALUATION N..-781- SERVICE Most Widely d and Trusted ICC-ES Evaluation Report ESR-1474 Reissued October 2016 This report is subject to renewal October 2018. www.icc-es.org 1 (800)423-6587 (562) 699-0543 A Subsidiary of the International Code Council® :DIVISION:06 00 00—WOOD, PLASTICS AND 3.6 DESCRIPTION COMPOSITES Section:06 16 00—Sheathing 3.1 Sheathing Panel: The ZIP System® Wall Sheathing panel is an OSB wood DIVISION:07 00 007--THERMAL AND MOISTURE structural panel having a laminated exterior facer. The PROTECTION Exposure 1.OSB complies with'US DOC PS 2 for wood Section:07 25 00=Water-resistive Barriers/Weather structural.panels. The exterior facer is a medium-density,: Barriers phenolic-impregnated, polymer-modified sheet material Section:07 27 00—Air Barriers qualifying as a Grade D water-resistive barrier(required by Section 251.0.6 of the 2012 and 2009 IBC).The panels-are ' REPORT HOLDER: nominally 4 feet wide by 8,.9, 10, 11 or 12 feet long and have a square-finished-edge or machined-edge profile. HUBER-ENGINEERED WOODS,LLC When tested in accordance with ASTM E96. (water ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE,SUITE 300 method), the polymer-modified sheet overlay has a CHARLOTTE, NORTH CAROLINA 28262 minimum vapor 2 permeance of 12 perms [68.6 X (800)933-9220 10" kg/(Pa-s-m )].• Equivalent Water Vapor Transmission www.huberwood.com rate (WVT) "of the polymer-modified sheet _overlay is 83.4 g/(24h-m )when tested at 73.4°F(23 C). .EVALUATION SUBJECT: The water-resistive barrier and air barrier properties of the ZIP System® Wall Sheathing Panels are not affected ZIP SYSTEM®WALL SHEATHING when the' panels are manufactured to'comply as.'facing materials for SIPS in accordance with Section R610.3.2 1.0' EVALUATION SCOPE and Table R610.3.2 of the"2015 IRC (Section R613.3.2 Compliance with the following codes: and Table R613.3.2 of the 2012 and 2009 IRC). ® 3.2 Seam Tape: ■ 2015,2012 and 2009 International'Building Code (IBC) ® The ZIP SystemTM seam tape is a self-adhering membrane ■ 2015, 2012 and.2009 International Residential Code tape consisting of 'acrylic adhesive laminated to a (IRC) polyolefin backing. The tape is 0.012 inch (0.30 mm) thick ■ 2015, 2012 and 2009 International Energy Conservation with a minimum width of 3/4 inches(95.2 mm), and comes Code®(IECC) in rolls of various lengths. Properties evaluated: 4.0 INSTALLATION ■ Weather resistance 4.1 General: ■ Air leakage Installation of ZIP System® Wall Sheathing panels must. comply with the applicable ,code, this report and the 2.0 USES manufacturer's published installation instructions. The ® manufacturer's published installation instructions must be ZIP System Wall .Sheathing panels are used,.. as available at the jobsite during:installation. combination wall sheathing, air barrier, and water-resistive barrier. This report recognizes,the use of ZIP System®• 4.2 Application: Sheathing, when installed with ZIP SysternTM flexible 4.2.1 General:-The ZIP System® Wall Sheathing panels flashing seam tape, in walls of Type V construction (IBC) must be attached to wall framing in accordance with the and dwellings under the IRC, and as an alternate to the applicable code for wood structural panels, and in water-resistive barrier required in.Chapter 14 of,the IBC compliance with their.panel span rating. The panels must and Chapter.7 of the IRC,'and to the air barrier required by be installed with the polymer-modified. sheet overlay Sections R402.4 and C402.5.1 of the 2015 IECC(Sections facing the exterior. In accordance with the manufacturer's R402.4 and C402.4.1 of the 2012.IECC; Sections.402.4.1 published installation instructions, it is recommended that and 502.4.3 of the 2009 IECC). the square edges of the panels be installed with a-,gap /CC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed i.� as an endorsement of the subject of the report or recommendation for its use.There is no warranty by/CC Evaluation Service,LLC,'express or implied as El.�:l to any finding or other matter in this report,or as to any product covered by the report. Copyright O 2016]CC Evaluation Service,LLC. All rights reserved. Page 1 of 6 ESR-1474 I Most Widely Accepted and Trusted Page 2 of 6 between adjacent panels and between panels and alternative to what is specified in, those codes listed in dissimilar materials. All ZIP System®Wall Sheathing panel Section 1.0 of this report, subject to the following seams must be sufficiently sealed with ZIP System seam conditions: tape.All overlay surfaces must be dry and free of sawdust 6.1 This evaluation report and the manufacturer's and dirt prior to application of the ZIP System seam tape. published installation instructions, when required by The ZIP SystemTm seam tape must extend a minimum of the code official, must be submitted at the time of 1 inch (25.4 mm) past the panel edge T-joint intersections permit application. and must be centered within /2 inch (12.7 mm) over the middle of panel seams.The tape must be pressed firmly to 5.2 The ZIP System Wall Sheathing panels must be adhere to the surfaces and seal the seams.Wrinkles in the manufactured, identified and installed in accordance ZIP System TM seam tape are acceptable unless they with this report and the manufacturer's published create a leak path to the panel seam. installation instructions. In the event of a conflict 4.2.2 Flashing: Flashing complying with the applicable between the instructions and this report, this report must govern. code must be installed at the perimeter of door and window assemblies, penetrations and terminations of 6.3 The ZIP System® Wall Sheathing panels must be exterior wall-assemblies, exterior wall intersections with . covered with a code-complying exterior wall covering, roofs, chimneys, porches, decks, balconies, and similar or one that is recognized in a current ICC-ES projections, and at built-in gutters and similar locations evaluation report. where moisture could enter the wall. An adhesive-backed 5.4 The OSB sheathing must comply with US DOC PS-2. flashing tape recognized in a current ICC-ES evaluation report must be installed -to seal all ZIP System Wall 5.5 Fire-resistance=rated construction is outside the Sheathing flashing joints. Penetration items must be scope of this report. sealed to the panels. The adhesive-backed flashing tape 6.0 EVIDENCE SUBMITTED must comply with the ICC-ES Acceptance Criteria for 6.1 Data in accordance with the ICC-ES Acceptance Flexible Flashing Materials (AC148) and must be installed Criteria for 'Water-resistive Membranes Factory- in accordance with the manufacturer's published bonded to Wood-based Structural Sheathing, Used as installation instructions. See ;Figures 1 through 7 of this Water-resistive Barriers (AC310), dated May 2008 report for typical flashing, water-resistive barrier and air (editorially revised August 2015). barrier assembly installation details. 4.2.3 Air Barrier Assembly: ZIP System ® Wall 6.2 Air leakage data in accordance with ASTM E2357. Sheathing I fastened to maximum 24-inch-on-center 7.0 IDENTIFICATION (610 mm), wood wall framing, using minimum 6d nails Each ZIP System®Wall Sheathing panel described in this spaced at 6 inches (152 mm) around panel edges and at report must bear a label that includes the manufacturer's 12 inches (305 mm) in the field, leaving a /e-inch name (Huber Engineered Woods LLC), the product name, (3.18 mm) gap between panels, forms an air barrier nominal panel thickness, the evaluation report number assembly when the gaps between panels and the ' (ESR-1474);and the words"Mill 229, Crystal Hill,Virginia"; perimeter of penetrations are sealed with ZIP SystemM "Mill 228, Easton, Maine"; "Mill 227, Commerce, Georgia"; seam tape as required by Section 4.2.1.The assembly has or"Mill 290, Broken Bow, Oklahoma."The OSB sheathing. demonstrated azmaximum air leakage of 0.0072 cfm/fe must also bear a label demonstrating compliance with [0.037 U(s m )] infiltration and 0.0023 cfm/ft US DOC PS 2 from an approved inspection agency. The [0.012 U(s•m )] exfiltration at a pressure differential of ZIP SystemTm seam tape roll must be labeled with the 1.57 psf (75. Pa) when tested in accordance with ZIP System logo and the evaluation report number ASTM E2357. ESR-1474(see Figure 8). 6.0 CONDITIONS OF USE The ZIP System®Wall Sheathing-panel and tape system described in this report complies with, or is a suitable ESR-1474 I Most Widely Accepted and Trusted Page 3 of 6 bUTSIDE INSIDE LC -PPES"IE POLYlSiETHAK FOAM OR ✓_ . 1MHMW SILL CAULKING REC048dEFIDED ZIP BY FLASHING WALL SH=ATHNG 5 NANUFACMRER RG".FRANCIG Y. A HI -BACKED •1� ,� FLLASASHING<•JG TAPE �. y, • .ADHESIVE-SACKED FIA'.]NND 7AFE ROUGH FRAMING r .ZIP SY51EU" , WALL SHEK H14G ' LOW-PRESIDURE PCOURETHANE FONT OUTSIDE LNE WNWK HEAP} SILL SECTION HEADER SECTION WINDOW JAMB OUTSIbE ZIP 56TE1 WALL SHEATHING i ADHESIVE=BAD(ED FLASHING TAPE INSDE LOW-PRESSURE POLYURETHANE FOAM JAMB SECTION FIGURE 1—TYPICAL CROSS SECTIONS OF FLANGED WINDOW ESR-1474 Most Widely Accepted and Trusted Page 4 of 6 GUTSUE IRSOE t zp Sm Eu' } WFLL:SHEATHHG VANMAY SL i f anr:ESLE-DACAED nA�Lnc'TAF� NouGL FeKuwo- l PO efi NE FOAM CNRNYJG UACK DAM iQW;PRESM .. POLYURETHAHE • \`� FOF'll ADHESWE-BACKED � \' FLASHING TA MOD HEAD .. FLAMM ROUGH FRAMING ZJF S IEN' WALL'HEATHING OUTr[UE lC7.GE wrlom HEAD Y ' SILL SECTION HEADER SECTION WINDOW JAMB ZIP SYSTEM` WALL SHEATHING ADHESIVE-BACKED FLASHING TAPE OUTSIDE CAULKING i ROUGH OPENING INSLDE LOW-PRESvtNRE POLYURETHANE FOAM JAMB SECTION FIGURE 2--TYPICAL CROSS SECTIONS OF INSTALLED BRICK MOLD WINDOW ESR-1474 I Most Widely Accepted and Trusted Page 5 of 6 TNI ZIP SYSTEM ZIP SYSTEM"" WALL:SHEATHING WALL'SHEATHING - WALL FRAMING WALL FRAMING ADHESIVE-BACKED FLASHING TAPE FLASHING FASTENER ADHESIVE-BACKED FLASHING TAPE COUNTER.FI.ASHING METAL FLASHING FLASHING FASTENER BASE FLASHING ADHESIVE-BACKED FLASHING TAPE FLASHING FASTENER ROF UNDERLAYMENT(FELT) ADHESIV ORLIN E FLASHING TAPE O • � r=ROF..UNDRLAYMENT'(FELT)' ROOF SHEATHING ROOF SHEATHING r.Y�. ROOF JOIST / ROOF JOIST FIGURE 3—ROOF-WALL INTERSECTION(OPTION 1) FIGURE 4—ROOF-WALL INTERSECTION(OPTION 2) Y hamm mu - . MRt17.R�Td —NQtiWTA 6uThTlAfpN Va mscm US:'41TY� 'MN1tRIl1t1Q--"-"' rppmnd YbY.(HItNP'F �y�-w2t GeA'I+19 .. .16Ytfit')iliC _ Tj} ifSi9C37REATfD iR[mKTRFMtL l..Lq 6=L9lAiC'---a S .I 4OdglOCT-----» A GW1IXT```��`�'''^^`��� • E1fJORR49FT6� � FIOCROMR . C�IwCLW�1L tt\\„\\\\\\\\\\\\ •—"""'H/•TwG'u'C �dA�YYidFYft1 � a0t[.SVF-itWDNAstKti+P� 11q�1TY1]TIDi@MC0�1i749tP4 ....:-,---i uLm FM1UUPSMXL6�CLl7!{TDffiA tl 531Gb£T f6'tYt r ftu t44»C{1QOirG�S-.'. � —..� �"` rrceatuns WtYQtt:tQCYKt � L� r LL ,L t i ITil- - _ e hRN.4Tu axvvnt+� FIGURE 5—TYPICAL WALL-SILL INTERSECTION FIGURE 6—TYPICAL WALL-SILL INTERSECTION AND FLASHING DETAILS FOR BRICK SIDING AND FLASHING DETAILS FOR LAPPED SIDING ESR-1474 Most Widely Accepted and Trusted Page 6 of 6 Adhesive-Backed Flashing Tape FIGURE 7—INSTALLATION AT PENETRATION OPENING(NON-FIRE-RESISTANCE RATED) 1 1 FIGURE 8—LABELING FOR THE ZIP SYSTEM SEAM TAPE ROLL tICC EVALUATION c c SERVICE IMES Evaluation Report ESR-1474.FBC Supplement Reissued October 2016 This report is subject to renewal October 2018. www.icc-es.org 1 (800)42376587 1 (562) 699-0543 .A Subsidiary of the International Code Council® DIVISION:06 00 00—WOOD, PLASTICS AND COMPOSITES Section:06 16 00—Sheathing DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 25 00—Water-Resistive Barriers[Weather Barriers Section:07 27 00—Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE;SUITE 300 CHARLOTTE,NORTH CAROLINA 28262'. (800)933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM®WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose.of this evaluation report supplement is to indicate that ZIP System® Wall Sheathing panels, recognized in ICC-ES master evaluation report ESR-1474, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2014 Florida Building Code-Building 4 2014 Florida Building Code—Residential 2.0 CONCLUSIONS The ZIP Systems Wall Sheathing panels, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, comply with the 2014 Florida Building Code—Building and the 2014 Florida Building.Code—Residential, provided the design and installation are in accordance with the International Building Codes provisions noted in the master report. Use of the ZIP Systems Wall Sheathing panels for compliance with the High-Velocity Hurricane Zone provisions of the 2014 Florida Building Code—Building and the 2014 Florida Building Code—Residential has not been evaluated, and is outside the scope of this evaluation report. For products falling under Florida Rule 9N-3, verification that the-report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is'the responsibility of an approved validation entity;(or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued October 2016. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as a� to any finding or other matter in ibis report,or as to any product covered by the report. maw Copyright@ 2016 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 1 1 EVALUATION C ICC C , ,3-z$. S E IMES Environmental Report 'VAR-1012 Reissued September 2015 This report is subject to renewal September 2017. www-icc-es.org/ep 1 (800)423-6587 1 (562)699-0543 A Subsidiary of the International Code Council® DIVISION:06 00 00—WOOD; PLASTICS AND • 2013 California Green Building Standards Code COMPOSITES (CALGreen),Title 24, Part 11 (see Table 3 for details) Section:06 12 00—structural Panels . National Green Building Standard (ICC 700-2008) Section:06 16 00—Sheathing (see Table 4 for details) DIVISION:07 00 00—THERMAL AND MOISTURE • 'National Green Building Standard (ICC 700-2012), PROTECTION (see Table 5'for details) Section:07 21 00—Thermal Insulation . LEED for Homes 2008(see Table 6 for details)` Section:07 25 00—Water-Resistive Barriers/Weather Barriers - LEED v4 for Homes, Design and Construction (see Section:07 27 00—Air Barriers Table 7 for details) REPORT HOLDER: LEED 2009 for New Construction and Major Renovations (see Table 8 for details) LEED 2009 for HUBER ENGINEERED WOODS, LLC Schools New Construction and Major Renovations (see 10925 DAVID TAYLOR DRIVE Table 9 for details) CHARLOTTE,NORTH CAROLINA 28262 • LEED v4 for Building Design,and Construction (BD+C) (800)933-9220 (See Table 10 for details) www.huberwood.com - ANSI/GBI 01-2010 — Green Building Assessment EVALUATION SUBJECT: Protocol for Commercial Buildings (see,Table. 11 for details) ADVANTECH®(AT-SERIES)SHEATHING SPAN; 2.0 USES ADVANTECH®(AT-SERIES)FLOOR SPAN;ZIP-SYSTEM® ROOF SHEATHING;ZIP SYSTEM®WALL SHE AdvanTech® (AT-Series) Sheathing Span, AdvanTech® ZIP SYSTEM®R-SHEATHING(INSULATING SHEATHING) (AT-Series) Floor Span,ZIP System Roof Sheathing and ZIP System Wall Sheathing are used for a variety of 1.0 EVALUATION SCOPE interior and exterior framing and sheathing applications. Compliance with'the following'evaluation criteria: ZIP System® R-Sheathing panels are used as combination wall sheathing and continuous insulation in • ICC-ES Environmental Criteria for Determination of Bio- conventional wood-framed wall construction. based Material Content(EC102),dated March 2012. 3.0 DESCRIPTION ICC-ES Evaluation Guideline for Determination 'of xp AdvanTech (AT-Series)Sheathing Span and AdvanTech Source of 'Recovery, Extraction, Harvest and Series) Floor Span wood structural Manufacture for Materials .or Products (EC114), dated E panels are March 2012 Exposure 1 ,oriented strand board (OSB) panels manufactured with strands from a single wood species or a • ICC-ES Environmental Criteria for Determination of combination of wood species blended with an exterior-type .Formaldehyde Emissions: of -Composite Wood and adhesive system to comply with U.S. DOC PS-2 and the Engineered Wood Products (EC108), dated March applicable ICC-ES report as indicated in Table 1. 2012. ZIP System® Roof Sheathing and ZIP System® Wall • ICC-ES Environmental Criteria for Determination of Sheathing wood structural panels are OSB panels with Certified Wood and Certified Wood Content in Products laminated, resin-impregnated, polymer.-modified sheet (EC109), dated March 2012. material manufactured to comply with,U.S. DOC PS-2 and the applicable ICC-ES reports as indicated in Table 1.The Compliance eligibility with the applicable sections of panels are installed with ZIP System® self-adhering the following green building rating systems,standards membrane tape. The tape is outside the scope of this and codes: evaluation report. • 2012 International Green 'Construction Code (IgCC) ZIP System® R-Sheathing is .an insulated sheathing (see Table 2 for details) made by combining 7/jr,-inch-thick ZIP System® Wall ICC-ES Verification ofAaributes Reports are issued tinder the ICC-ES VAR Environmental Program.These reports are not to be construed as representing aesthetics or any other �. attributes not specifically addressed,nor are they:to be construed as an endorsement of the subject of the report or a recommendalion for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. Copyright O 2016 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 6 VAR-1012 I Most Widely Accepted and Trusted Page 2 of 6 Sheathing as described in ESR-1474 with a layer of 6.2 ICC-ES EC114. [Evaluation applies to IgCC Section maximum 1-inch-thick (25.4 mm) rigid foam plastic 505.2.5; CALGreen Section A5.405.1; iCC 700-2008 insulation laminated to the interior face with PVA adhesive. Section 608.1; [CC 700-2012 Sections 609.1, Refer to ESR-3373 for additional product description. 11.609.1 & 12.1(A).609.1; LEED Homes MR 2.2(c); 4.0 CONDITIONS LEED v4 Homes MRc3; LEED NC MR 5; LEED Schools MR 5; LEED v4 BD+C MRc3; ANSI/GBI 01- 4.1 Code Compliance: 2010 Section 10.1.4.1]: AdvanTech® (AT-Series) Sheathin% Span, AdvanTech® 5.3 IMES EC108 [Evaluation applies to IgCC Section (AT-Series) Floor Span, ZIP System Roof Sheathing, ZIP 806.1; ICC 700-2008 Section 901.4(6); ICC 700-2012 System® Wall Sheathing and ZIP System® R-Sheathing Sections 901.4(6) & 11.901.4(6); LEED NC EQ 4.4; have been evaluated for compliance with the requirements LEED Schools EQ 4.4; LEED v4 BD+C EQc2]. of the International Codes as listed in Table 1 of this report. 5.4 ICC-ES EC109 [Evaluation applies to ICC 700-2008 ' 4.2 Green Rating Systems, Standards and Code Section 606.2; ICC 700-2012 Sections 606.2(2), Eligibility: 11.606.2(2) & 12.1(A).606.2; ANSI/GBI 01-2010 The information presented in Tables 2 through 11 of this Section 10.3.2.1]. report provides a matrix of areas of evaluation and 5.5 Documentation establishing and documenting all corresponding limitations and/or additional project-specific major sources of primary manufacturing energy requirements, and offer benefit to individuals who are [Evaluation applies to ICC 700-2008 Section 606.3; assessing eligibility for credits or points. ICC 700-2012 Sections 606.3& 11.606.3]. The final interpretation of the specific requirements of the 5.6 ICC-ES ESR-1474 documenting that ZIP System Wall respective green building rating system, standard and/or Sheathing is equivalent to a code-prescribed water- code rests with the developer of that specific rating system resistive barrier [Evaluation applies to CALGreen or standard or the Authority Having Jurisdiction, as Section 5.407.1; ICC 700-2008 Section 602.9; ICC applicable. 700-2012 Section 602.1.8]. Compliance with items noted as "Verified Attribute" is 5.7 Refer to ICC-ES ESR-1474 for evaluation of the ZIP subject to any conditions noted in the tables. Decisions on System Wall Sheathing as an air barrier assembly compliance with those items noted as "Eligible for Points" [Evaluation applies to IgCC Section 605.1.2.1.1; ICC in Tables 2 through 11 rests with the user of this report, 700-2008 Section 703.2.1; ICC 700-2012 Sections and those items are subject to the conditions noted. The 701.4.3.2, 11.701.4.3.2 & 12.1.701.4.3.1; LEED user is advised of the project-specific provisions that may Homes EA 3; LEED v4 Homes EAc7]. be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this 6.0 IDENTIFICATION report. Rating systems or standards often provide supplemental information as guidance. AdvanTech (AT-Series) Sheathing,� Span, AdvanTech® (AT-Series) Floor Span, ZIP System Roof Sheathing, ZIP 5.0 BASIS OF EVALUATION System® Wall Sheathing and ZIP System R-Sheathing The information in this report, including the "Verified products are identified with a stamp noting the Attribute," is based upon the following supporting manufacturer's name(Huber Engineered Woods, LLC)and documentation: address, the product name the manufacturing location, the ]CC-ES evaluation report number (if applicable), and the 5.1 ICC-ES EC102 [Evaluation applies to IgCC Section name or logo of the inspection or grading agency. The 505.2.4; CALGreen Sections A4.405.4 & A5.405.2; report subjects are also identified on the product and/or ICC 700-2008 Section 606.1(2); ICC 700-2012 packaging with the VAR Environmental Report number Sections 606.1, 11.606.1 & 12.1(A).606.1; ANSI/GBI (VAR-1012)and the ICC-ES SAVE Mark, as applicable. 01-2010 Section 10.1.2.21. TABLE 1—REFERENCE STANDARD OR EVALUATION REPORT NUMBER FOR HUBER ENGINEERED WOODS LLC PRODUCTS PRODUCT REPORT NUMBER/ REFERENCE STANDARD AdvanTech®(AT-Series)Sheathing Span ESR-1785 AdvanTech®(AT-Series)Floor Span ZIP System®Roof Sheathing ESR-1473&ESR-2227 ZIP System®Wall Sheathing ESR-1474&ESR-2227 ZIP System®R-Sheathing ESR-3373 ' VAR-1012 I Most Widely Accepted and Trusted Page 3 of 6 TABLES 2 THROUGH 11 • section Posslhie AdvanTech AdvanTech ZIP System ZIP System ZIP System Number Section Intent Points conditions of use to Quality Shoat Flooring Roof Wall RSheathing Sheathing Sheathing TABLE 2—SUMMARY OF AREAS OF ELEGIBILITY WITH 2O12 INTERNATIONAL GREEN CONSTRUCTION CODE 505,2.4 Bio-based products WA All Huber mod products are qualified as blo-based. • • • • 05 Products shall be recovered,harvested,extracted&manufactured within a 5D0 mile 1800 km)radius of the building site.Where only a porfion of a material or product is recovered,harvested,extracted&manufactured within 500 miles(800 km),only 505.2.5 Indigenous materials MA that portion shall be included.Where tesources we transported by water or rail,the O O O 0 distance to the building site shall be determined by multiplying the distance that the resources are transported by water or rall by 0.25,&adding that number to the distance transported by means other than water or raif 605.1.2.1.1 Air harder installation WA Install the system in accordance with the manufacturers installation instructions an • • ICOES evaluation report ESR•1474. 806.1 Formaldehyde emissions TWA Huber mod stwctural panels comply with US DOC PS 2(See Table 1 of this report • • • • O'' and are exempt from formaldehyde emissions testing. TABLE 3—SUMMARY OF AREAS OF ELEGIBILITY WITH 2O13 CALIFORNIA GREEN BUILDING STANDARDS CODE A5,405.1 Regional matedais Verify local products that are extracted,processed and manufactured wHhin O 0 O O California or 500 miles 805 km of the job site AE405.2 Biobased materials All Huber mod products are qualRed as bio-based. • • • • 05 Elective A4.405.4(3) Renewabl e sources Materials from renewatble sources(such as engineered wood). • • • • 05 A4.405.4(5) A5.405.2.1 Certified Wood Under review by California Building Standards Commisioms MA WA WA MA WA 5.407.1 Water-resistant exterior wall assembly Huber products provide a water-resistant exterior wall envelope. O O Mandatory 4.504.5 Composite woad product emissions EVVP products do not apply to the composite wood product definition: 5.504.4.5 TABLE 4—SUMMARY OF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD(ICC 700-2008) 602.9 Water-tes"stive barrier Mandatory Install a vvaler-resistive barrier and/or drainage plan system behind exterior veneer • • and/or siding. Two types of blobased materials are used,each for To earn 6 points products must be at least 1%of the construction material cost AN 606.1(2) more than 1%of the projects projected building 6 another blo-hased product at 1%of material cost must he used.1 or 3 points are • • • • Os material cost available for greater than 0.5%. • Tv+u cenilled wood-based products are used for To earn 3 points a second cerfified wood product must also be used as a minor 606.2(1) minor elements of the building,such as all walls, 3 element' • • • • Os ft.. or roof Two"dined wood-based products are used for To earn 4 points a second cer8fied wood product must also be used as a major 606.2(2) major elements of the buildng,such as all walls, 4 element' • • • • 0s boors orrcof Materials are used for major components of the building that are manufactured using a minimum of 2 each To earn 6 points the products must be used for at least 3 major components of the s 606.3 33%of primary manufacturing process energy 6 max building.2 points may be earned when used for each major component • • • • O derived from renewable sources,combustible waste sources,or renewable energy credits 0 =Eligible for points • =Verified attribute =This provision does not apply to this product Note:Footnotes are located after Table 1t VAR-1012 I Most Widely Accepted and Trusted Page 4 of 6 TABLES 2 THROUGH 11 Continued • Section Possible AdvanTech AdIwTech ZIP System ZIP System ZIP System Number Section Intent Points Conditions of Use to Ouaiffy Sheathing Flooring Roof Wall RSheathing Sheathing Sheathing TABLE 4—SUMMARY OF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD(ICC 700-2008)(Continued) 608.1 Indigenous materials 2 each To eam 2 points verity local products are originated,produced,grew naturally of O O O O I')coax occur naturally within 500 miles 805 km of ob sites Insulation and air sealing is Installed In accordance with all the following,as 3 applicable: • 703.2.1 Insulation and air sealing 15 max O O (1)third-party verification performed 15 pts, (2)no third-party verification performed 3 pis Structural plywood used for floor,wall,and/or roof sheathing complies with DOC PS 1 andfor DOC PS 2 OSS used(or Poe4 wall,and/or roolsheathing To meet this a min'unum of 85%of OSB or plywood in the building must consist of 901.4(t) complies with DOC PS 2.Panels are made wdh Mandatory • • • • • mosture-resistant adhesives and the trademark Huber products. indicates the adhesives are Exposure 1 or Exterior (plywood)and Exposure 1(068) 901.4(6) Non-emitting products,which can include structural 4 A minimum of 85%of product In the building are the identified Huber products. • • • • •s wood lrami TABLE 5—SUMMARY OF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD(ICC 700-2012) IreUilawater-resistive barrier andfor drainage plan system behind extedcrveneer r- 6021.8 Water-resistive barrier Mandatory • • and/or siding. 606.1(2) Two types of blobased materials are used,each for To earn 6 points products must be at least 1%of the construction material cost AN 11.606.1(b) more than 1%of the projects projected building 6 another biobased product at 1%of material cost must be used.1 or 3 points are • • • • Os 12.1 A.606.1 material cost available for greater than 0.5%. 606.20) Two certified wood-based product are used for To earn 3 points a second certified wood product must also be used as a minor s 11.606.2(1) minor element of the building,such sasH trim, 3 element' • • • • O 121 A.606.1 cabine ,ar milMrwk 606.2(2) Two certified mod-based products are used for To earn 4 points a second certified wood product must also be used as a major s 11.606.2(2) major elements o1 the building,such as all walls, 4 element.[ • • • • O 12.1 .606.2 floors or roof Materials are used for major component of the building are manufactured using a minimum of 33% 6606. of primary manufacturing process energy derived 2 each To earn 6 point the products must a used for ata least 3 major components of the • • • • Os 11,60fi,3 from renewable sources,combustible waste 6 max building.2 points may be earned when used for each major component. sources,or renewable energy credits To earn 2 points verify material is produced,grows naturally,or occurs naturally < within 500 miles(805 km)of the job site If transported by truck or 1500 miles(2414 ✓�"' "', 2 each km)i1 transported for d least 80%of the total distance by rail or water.Products the > 609.1 Regional materials O O O O ' 10 max are assembled or produced from multiple raw materials qualify if me wegMed average(by weight or volume)of the distance the raw materials have been transported meet the distance criteria" Insulation and air sealing is Installed in accordance with all the following.as 701.4.3.2 3 11.701.4.3.2 Insulation and air sealing 15 max (1)thl dpany verification performed 15 pts, _ O O 12.1.701.4.3.1 - - (2)no mind-pang verification performed 3 pis Structural plywood used for floor,wall,and/or roof sheathing complies with DOC PS 1 and/or DOC PS 901.4(t) 2 OSB used for Poor,wall,and/or roof sheathing 11.901.4(1) complies with DOC PS 2.Panels are made with Mandatory To meet this a minimum of BS% plywood al OSa or In the building must consist of Huber products. • • • • • 12.1.901.4(1) moisture-resistant adhesives 8 the trademark indicates the adhesives are Exposure 1 or Exterior (plywood)d Exposure 1(OSB) 901.4(6) Non-emitting products,which can include structural 4 A minimum of 85%of product In the building are the identified Huber products. • • • • Os 11.901.4 6 wood framing 0 =Eligible for point • =Verified attribute ' =This provision does not apply to this product Note:Footnotes are located after Table tt 4 VAR-1012 I Most Widely Accepted and Trusted Page 5 of 6 TABLES 2 THROUGH 11 Continued ' Section Possl6le 21P System ZIP System Numher Section Intent Points Conditibns of Use to OuaIITy for Points Ait;-Tech AdvanTech Raof Wall ZIP System Sheathing Fborin9 Sheathing Sheathing RSheathing TABLE 6—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED FOR HOMES 2008 EA 3 Air Infiltration 3— To cam 2 or 3 points meet the air leakage requirements shown O O in Table 17 of the credit as applicable. _ MR 21 FSC certified tro cal wood 0.5 each 2 2� 2" 2 2 P am- To earn 0.5 polnt per component use FSC-certified tropical wood Environmentally preferable products for root wall& 0.5 each To earn Points use products that are extracted,processed and manufactured within MR 2.2(c) 500 miles(805 km)of the site for a minimum of 90%(by weight or volume of the Doors;interior 8 exterior framing 8 sheathing 8 maz O O O O corn nent° e TABLE 7—SUMMARY 7—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED V4 HOMES EAc7 Air Infiltration 2 max To earn 1 or 2 points based on air leakage rates determined by testing and - a O O verification "I`si MR FSC certified tropical wood Prerequeste All mod must be nontroplasl or certified by FSC or USGBC-approved equivalent 2 2 2 4 2 2 pbon l to earn points use framing that Is extracted,processed and manu actmec r _ MRc3 Environmentally preferable products for roof,wall& 0.5 each within 100 miles(160 km)of the site for a minimum of 50%(by weight orvolume)of O O O Othe com nor'! Fg floors;interior&exterior framing&sheathing S max Option 2:Use mod products certified by FSC or USGBC-approved equivalent 2 2 2 2 02.+ EOc2 Lax emitting materials 1 To earn 1 point use wood composite products contaning no-added urea- s formaldehyde resins. • • • • • TABLE 8—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED 2009 FOR NEW CONSTRUCTION AND MAJOR RENOVATION MR 5.1 Regional materials(10%of content) 1 To earn 1 point use products that are extracted,processed and manufactured withit O O O O 500 miles(605 km)of the site for a minimum of 10%(by cost)of total materials ^� MR 5.2 Regional materials(20%of content) 2 value.To earn 2 points use a minimum of 20%6 O O O O MR Certified wood 1 To earn 1 point use a minimum 50% (based on cost) of mod-based 2 2 2 2 2$L materialstproducts certified to FSC re ulrements° EQ 4.4 Law emitting materials 1 To earn 1 point use wood composite wood products containing no-added urea- formaldehyde resins. • • • • 05 TABLE 9—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED 2009 FOR SCHOOLS NEW CONSTRUCTION AND MAJOR RENOVATION MR 5.1 Regional materials(10%of content) 1 To earn 1 point use products that are extracted,processed and manufactured Mhjr O O O O t ; 500 miles(805 km)of the site for a minimum of 10%(by cost)of total materials MR 5.2 Regional materials(20%of content) 2 value.To earn 2 points use a minimum of 20%° O O O O MR 7 Certified wood To earn 1 point use a minimum 50% (based on cost) of wood-based 1 2 2 2 2 2 � irmsterial0products certified tof Cre uirem cos° EQ 4.4 Lowemltting materials 1 To earn 1 point use wood composite wood products containing no-added um- formaldehyde resins. • • • • 05 TABLE 10—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED v4 BUILDING DESIGN AND CONSTRUCTION(BD+C) MRc3 Sourcing of raw materials-certification of newwood 1 Option 2:Use wood-based materials/products certified by FSC or USGBC-apprwed 2 2 2 2 2 products uivalent O Products meeting the requirements MRc3 Option 2 may be purchase a for additional MRc3 Sourcing of raw materials-source location WA credit based on source location(extraction,manufacture and purrchase point)based s s e s on location relative to project sAJ5 IEOc22 Lox emitting materials WA EWP and lumber products do not apply to the composite wood product defintieA 0 =Eligible for points • =Verified attribute ` =This provision does not apply to this product Note:Footnotes are located after Table 11 VAR-1012 I Most Widely Accepted and Trusted .Page 6 of 6 TABLES 2 THROUGH 11 Continued Section Posslhie Advan7ech Advan7ech ZIP Systom ZIP System ZIP System Number Section Intent Past Condigona of Use b Quality for Points Sheathing Flooring Roof Wall RSheathing Sheathing Sheathing TABLE 11—SUMMARY OF AREAS OF ELEGIBILITY WITH ANSUGBI 01-2010-GREEN BUILDING ASSESSMENT PROTOCOL FOR COMMERCIAL BUILDINGS 10.1.22 Biobased Products-building assemblies 7 max Ali Huber wood products are qualified as Nobased • • • • 05 To earn credits use products that are extracted,processed and manufactured within 10.1.4.1 Regional Materials-building assemblies 5 vrax 500 miles(805 km)of the site for a minimum of 90%(by weight or volume of the O O O O componere 10.3.21 Certified wood 6 max Between 10%and 60%or more of wood-based products used in the building we • • • • OS third party certified. o =Eligible far points • =Verified attribute =This provision does not apply to this product , Footnotes: ' 'Certification is required of the manufacturer only.Vendor Chain of Custody is not required to qualify for this point 'Forest certification creditfw LEED 2009 resources FBI-exduaively and for LEED v4 resources either FSC or USGBGapproved equivalent Contact USGBC fora fat of approved equivalent programs. 'CGBSC recognizes importance of use of certified forest products however the specific requirements are currently under development This area is not be confused with the provisions of EQ 4.4 in LEED(Table 4)because the California Air Resources Board(CARS)dam not regulate engineered wood product emissions. 'Eligibility applies only to the wood-based sheathing potion of the panel. 'Regional material calculations based on project location provided by Huber upon request N/A=Not applicable t r EVALUATION i - Accepted i • i c c SERVICEIC ICC-ES Repor.t E,SR-1473 : ie . . . ewww.- . e• e This report is,subject to renewai'09/2017. r won DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION: 06 16 00—SHEATHING DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 30 05—ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 EVALUATION SUBJECT: ZIP SYSTEM® AND ZIP SYSTEM+Tm ROOF SHEATHING 1 C ICC ICC r ICC C� - PIVIG LISTED Look for the trusted marks of Conformity! ai►��► "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC)Award in Excellence" A Subsidiary of CODE ouNCjr ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not s`�oe specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a i recommendation forts use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as G!D �MAMOMWftv= ass to any finding or other matter in this report, or as to any product covered by the report. Pnowimninum4GN Copyright© 2015 ICC Evaluation Service, LLC.All rights reserved. F ICC EVALUATION N%�8 SERVICE Most Widely d and Trusted IMES Evaluation Report • , ESR-1473* Reissued September 2015. This report is subject to renewal September 2017. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:06 00 00—WOOD, PLASTICS,AND required in Chapter 15 of the IBC and "Chapter 9'of the COMPOSITES IRC.The OSB substrate complies with U.S.,DOC Pt-2 for Section:06 16 00—Sheathing wood structural panels and is overlaid on one side with a medium=density, phenol-impregnated, polymer-modified • DIVISION:07 00 00—THERMAL AND MOISTURE sheet material. The standard-size panels are nominally PROTECTION 4 feet by 8 feet. Oversize,panels, wider than 4 feet Section: 07 30 06—Roofing Felt and Underlayment (1219 mm) or longer than 8 feet (2438 mm),'or both, are also produced. The panels are available with either a REPORT HOLDER: square-finished-edge profile a, tongue-and-groove edge profile or a machined,edge,profile. The proprietary seam. HUBER ENGINEERED WOODS, LLC tape is a self-adhering sheet-type membrane consisting of ONE RESOURCE SQUARE acrylic.adhesive laminated to,a polyolefin backing, and the 10925 DAVID TAYLOR DRIVE,SUITE 300 face of the tape is labeled with ESR-1473. The tape is CHARLOTTE,NORTH CAROLINA 28262 0.012 inch thick (0.30 mm) with a minimum width of (800)933-9220 3 inches(76.2 mm),and comes in rolls of varying length. www.huberwdod.com 4.0 INSTALLATION EVALUATION SUBJECT: 4.1 General: ZIP SYSTEM®AND-ZIP SYSTEM+TM ROOF SHEATHING Installation .of ZIP System® and ZIP .System+Tnn roof sheathing must comply with the applicable code,this report 1.0 EVALUATION SCOPE and the manufacturer's published installation instructions. The installation instructions are to be available at the Compliance with the following codes: jobsite at all times during' installation. The instructions ■ 2015,2012 and 2009 International Building Code .(IBC). within this report must govern if there are any conflicts between the manufacturer's published instructions and this ■ 2015, 2012 and 2009 International Residential Code® report. (IRC) 4.2 Application: ■ 2013 Abu Dhabi International Building Code(ADIBC)t The ZIP.System and ZIP System+T^^. roof sheathing 1The ADIBC is based on the 2009 IBC.2009 IBC code sections'referenced panels must be installed .with the longer dimension in this report are the same sections in the ADIBC. perpendicular to the roof framing and fastened to the Properties evaluated: roof.framing in,-accordance with"the applicable code for ■ Structural—wind u lift resistance wood structural panels. 'The panels must be installed in I? accordance with the panel span rating as-shown on the ■ Nonclassified roof covering panels. All corners are to be securely fastened. Tongue- and-groove and machined edge "panels are designed to g provide"the correct gap size at the panel edges during ■ Weather resistance installation. Squared-edged panels must be spaced apart a 2.0 USES minimum of 1/8 inch (3.18 mm) at the time of installation. End joints of adjacent panel runs must be staggered. The ZIP System® and"ZIP System+TM roof sheathing panels panel must be installed with the l enaminated phenol- are used- as combination roof sheathing, and roof impregnated polymer-modified sheet material facing to underlaymt. the exterior. All ZIP System® 'and ZIP System+TM roof 3.0 DESCRIPTION sheathing seams must be sealed with the Zip System® tape. All overlay surfaces must be free of any significant The ZIP System® and ZIP System+TM roof Sheathing presence.of.debris particles or sawdust prior to installation panels are wood structural panels having a laminated of the ZIP System tape. Overlay surfaces must be void of facer. The ZIP System+TM panels are manufactured_using any free,water prior to application of the ZIP System®tape. a different resin than the Zip System®panels. . The panels The ZIP System®tape edges must be sealed and the tape are installed with a proprietary seam tape,which-allows the is to be centered within +/- % inch �12.7 mm) of all panel systems to be used as an alternate to the underlayment edge seam centers. All ZIP System and ZIP System+TM *Revised November 2015 ]CC-ES Evaluation Reports are not to be construed as representing'aesthetics or any other attributes not specifically addressed,nor are they to be construed 0 as an endorsement ojthe subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as 512 to anyfinding or other matter in this report,,or as to any product covered by the report. Copyright 0 2015]CC Evaluation Service,LLC. All rights reserved. Page 1 of 2 ESR-1473 I Most Widely Accepted and Trusted Page 2 of 2 roof sheathing surface defects, openings, cracks, etc., that wood structural panels with either a 24/16, 32/16 or completely penetrate the overlay and substrate, and 40/20 span rating. caused by handling or construction work, must be covered ® ® 5.4 In jurisdictions enforcing the IBC, the roof covering with the ZIP System tape. The ZIP System tape must system incorporating the panels is limited to extend a minimum of 1 inch (25.4 mm)past the panel edge installations in the following construction types: T-joint intersections. The ZIP System tape must be adhered to the ZIP System® and ZIP System+Tm roof . Type III-B and Type V-B sheathing. Wrinkles in the ZIP System seam tape are acceptable unless they create a leak path to the panel • Type III-A or Type V-A under the conditions seam. specified in footnote d of IBC Table 601 4.3 Roof Assemblies • Type III-A or Type V-A under the conditions specified in footnote b of IBC Table 601, for 4.3.1 Classified Roof Coverings occupancies other than Group F-1, H, M and S-1 ' 4.3.1.1 Class A: Underlayment is not required for a In jurisdictions enforcing the IRC, the roof covering minimum 1/2-inch thick Zip System+TM roof sheathing with system incorporating the panels may be installed on Class A asphalt glass fiber mat shingles. structures constructed in accordance with the IRC. 4.3.1.2 Class B: Underlayment is not required fora 5.5 Enclosed attics and rafter spaces must be ventilated minimum 7/,6-inch thick Zip System® roof sheathing with in accordance with the applicable code, except where Class A asphalt glass fiber mat shingles. unvented conditioned attic assemblies are permitted 4.3.2 Nonclassified Roof Coverings: The ZIP System® by 2015 and 2012 IRC Section R806.5 or 2009 IRC and ZIP System+Tm roof sheathing panels are limited to Section R806.4. installation on buildings permitted to have nonclassified 5.6 An ice barrier must be provided as required by roof coverings using code-complying asphalt-fiberglass Section 1507.2.8.2 of the IBC and Section R905.2.7 shingles,metal shingles, metal panels,wood shakes,wood of the 2015 IRC and Section R905.2.7.1 of the 2012 shingles, built-up roofing, slate and slate-type shingles, and 2009 IRC. and clay and concrete tile roof coverings. Roof coverings may be applied directly to the taped ZIP System and ZIP 5.7 Installation is limited to roofs having a slope of 2:12 System+TM roof panels unless multi-layer underlayments (16,67%slope)or greater. are required. 5.8 ZIP System® and ZIP System+TM roof sheathing 4.4 Wind Uplift Resistance: panels are manufactured by Huber Engineered Wind uplift design loads and ZIP System and ZIP Woods, LLC, in Crystal Hill, Virginia; Commerce, System+TM roof wood structural panel allowable uplift Georgia; Broken Bow, Oklahoma; and Easton, Maine, resistance shall be determined in accordance with under a quality-control program with inspections by Sections 1609 and 2304.8.2 of the 2015 IBC or 2304.7.2 of [CC-ES. the 2012 and 2009 IBC and Section R301.2.1 of the IRC. 6.0 EVIDENCE SUBMITTED Roof coverings must be fastened to the sheathing with mechanical fasteners sufficient to resist the design uplift Data in accordance with the ICC-ES Acceptance Criteria load. for Wood Structural Panel Roof Sheathing Factory- laminated with an Alternative Roof Underlayment(AC266), 5.0 CONDITIONS OF USE dated May 2008(editorially updated October 2015). The ZIP System® and ZIP System+TM roof sheathing 7.0 IDENTIFICATION panels described in this report comply with, or are suitable ® alternatives to what is specified in, those codes listed in Each ZIP System and ZIP System+TM roof sheathing Section 1.0 of this report, subject to the following panel covered by this report must bear a label that includes conditions: the manufacturer's name (Huber Engineered Woods, LLC) and address; the product name; the evaluation report 5.1 This evaluation report and the manufacturer's number(ESR-1473); and the grade, performance category published installation instructions, when required by and bond classification. the code official, must be submitted at the time of permit application. The panel mill label and span rating, grade, performance category and bond classification label must be visible on 6.2 The ZIP System®and ZIP System+TM roof sheathing the bottom face of panels, opposite the laminated facer. panels must be manufactured, identified and installed in accordance with this report and the manufacturer's The ZIP System• tape roll is labeled with the product published installation instructions. name and the evaluation report number(ESR-1473). 5.3 The ZIP System®and ZIP System+TM roof sheathing panels are limited to code-approved structural use for ICC EVALUATION c SERVICE Most Widely Accepted and Trusted IMES Evaluation Report ESR-1473 FBC Supplement Reissued September 2015 This report is subject to renewal September 2017. www.icc-es.orq 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:06 00 00—WOOD, PLASTICS,AND COMPOSITES Section:06 16 00—Sheathing DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION ' Section: 07 30 05—Roofing Felt and Underlayment REPORT HOLDER: HUBER ENGINEERED WOODS,LLC' ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE,SUITE 300 - CHARLOTTE,NORTH•CAROLINA 28262 (800)933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM®AND ZIP SYSTEM+TM ROOF SHEATHING 1.0 REPORT'PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP System® and Zip System+Tin roof sheathing, recognized in ICC-ES master evaluation report ESR-1473, has also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2014 Florida Building Code—Building ■ 2014 Florida Building Code—Residential ' 2.0 CONCLUSIONS The ZIP System®and ZIP System+TM roof sheathing, described in Sections 2.0 through 7.0 of the master evaluation report ESR71473, complies with the 2014 Florida Building Code--Building and the 2014 Florida Building Code—Residential, provided the design and installation are in accordance with the International Building Code®provisions noted in the master report, and with the condition that wind uplifting design loads must be determined in accordance with Section 1609 of the Florida Building Code—Building and Section R301.2.1 of the Florida Building Code—Residential. Use of the ZIP System® and ZIP System+TM roof sheathing- for compliance with the High:Velocity Hurricane Zone provisions of the 2014 Florida Building Code—Building and the 2014 Florida Building Code—Residential,has not been evaluated and is outside the scope of the evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity(or.the code official, when the report holder does not possess an.approval by the Commission). This supplement expires concurrently with the master report, reissued September 2015 and revised November 2015. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as ___aaaeeeeeeaaa to any finding or other matter in this report,or as to any product covered by the report. Copyright 0 2015 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 1 Florida Building Code Online Pagel of 1 l.. 12fQf ® BCIS Home Log In (user Registration Hot Topics I Submit Surcharge Stats&Facts. " Publications FBC Staff( BCIS Site Map Links i Search H lida Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List n Search Criteria Refine Search Code Version .2014 FL# 17147 Application Type' ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method., ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired' ALL Product Model,Number or Name ALL. Product Description' ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact'Resistant- ALL Design Pressure ALL Other ALL Search Results-Applications Ty" Manufacturer. Validated By Status L1714 - Revision Huber Engineered Woods LLC ICC Evaluation Service, Approved RI Category:Structural Components LLC. History Subcategory:Products Introduced as a Result,of New p05)599-9800 Technology, -Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. - Contact Us::2601 Blair Stone Road,Tallahassee FL32399 Phone:850-46-1824 , The State of Florida is an AA/EEO employer. ate of Florida ::Privacy Statement::Accessibility tement::Refund Statement "Under Florida law,email addresses are public'records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850,487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1;2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S:,please click)ygc�-. - -• Product Approval Accepts: ®© Credit Card Safe . https://www.floridabuilding.or'g/nr/Pr_app_lst.aspx 4/12/2017