Loading...
HomeMy WebLinkAboutDrive Cylinder_Test-0001-0004_7519510Test Information Test #Test Location Elevation Reference Drive Cylinder ID Weight of Cylinder (lb) Top Diameter (in) Bottom Diameter (in) Cylinder Height (in) Volume of Cylinder (cf)Field Technician 1 Footings: Footings for Stem Wall. E Footing -1.0 Top of Subgrade Psl 475 1.049 1.990 1.990 6.000 0.0108 Tech, Port St. Lucie 2 Footings: Footings for Stem Wall. N Footing -1.0 Top of Subgrade Psl 475 1.049 1.990 1.990 6.000 0.0108 Tech, Port St. Lucie 3 Footings: Footings for Stem Wall. W Footing -1.0 Top of Subgrade Psl 475 1.049 1.990 1.990 6.000 0.0108 Tech, Port St. Lucie 4 Footings: Footings for Stem Wall. S Footing -1.0 Top of Subgrade Psl 475 1.049 1.990 1.990 6.000 0.0108 Tech, Port St. Lucie Related Tests Test #Related Test #Test Type Remarks Pass: Density Pass Comments Test Results Test # Retest Of Test Date Proctor ID Method Soil Class. Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Wet Density (pcf) In Place Dry Density (pcf) Percent Compaction Min Comp. (%)Remark 1 1/12/21 20-036 (A --10.0 114.5 10.2 126.5 114.8 100 95 Pass 2 1/12/21 20-036 (A --10.0 114.5 10.6 128.7 116.4 102 95 Pass 3 1/12/21 20-036 (A --10.0 114.5 13.2 126.7 111.9 98 95 Pass 4 1/12/21 21-019 (A --9.5 109.5 14.4 124.3 108.6 99 95 Pass AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. Page 1 of 1 Drive Cylinder Test Method: ASTM D 2937 Permit # 2008-0171 Report Date: 2/10/2021 Client: Cole Construction Santa Rosa Beach, FL 32459 3295 W. County Highway 30A F Project: 4700 Indrio Road 113-21-64-5402 Fort Pierce, FL 4700 Indrio Road Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, Phone: 772-878-0072 Port St. Lucie Branch Page 1 of 2 AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. Page 2 of 1 Drive Cylinder Test Method: ASTM D 2937 Permit # 2008-0171 Report Date: 2/10/2021 Client: Cole Construction Santa Rosa Beach, FL 32459 3295 W. County Highway 30A F Project: 4700 Indrio Road 113-21-64-5402 Fort Pierce, FL 4700 Indrio Road Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, Phone: 772-878-0072 Port St. Lucie Branch Page 2 of 2 This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Feb 10, 2021 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies.