HomeMy WebLinkAboutDrive Cylinder_Test-0001-0004_7519510Test Information
Test #Test Location Elevation Reference
Drive
Cylinder ID
Weight of
Cylinder (lb)
Top
Diameter (in)
Bottom
Diameter (in)
Cylinder
Height (in)
Volume of
Cylinder (cf)Field Technician
1 Footings: Footings for Stem Wall. E Footing -1.0 Top of
Subgrade
Psl 475 1.049 1.990 1.990 6.000 0.0108 Tech, Port St.
Lucie
2 Footings: Footings for Stem Wall. N Footing -1.0 Top of
Subgrade
Psl 475 1.049 1.990 1.990 6.000 0.0108 Tech, Port St.
Lucie
3 Footings: Footings for Stem Wall. W Footing -1.0 Top of
Subgrade
Psl 475 1.049 1.990 1.990 6.000 0.0108 Tech, Port St.
Lucie
4 Footings: Footings for Stem Wall. S Footing -1.0 Top of
Subgrade
Psl 475 1.049 1.990 1.990 6.000 0.0108 Tech, Port St.
Lucie
Related Tests
Test #Related Test #Test Type
Remarks
Pass: Density Pass
Comments
Test Results
Test #
Retest
Of
Test
Date Proctor ID Method
Soil
Class.
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
Moisture
(%)
In Place Wet
Density
(pcf)
In Place
Dry Density
(pcf)
Percent
Compaction Min Comp. (%)Remark
1 1/12/21 20-036 (A --10.0 114.5 10.2 126.5 114.8 100 95 Pass
2 1/12/21 20-036 (A --10.0 114.5 10.6 128.7 116.4 102 95 Pass
3 1/12/21 20-036 (A --10.0 114.5 13.2 126.7 111.9 98 95 Pass
4 1/12/21 21-019 (A --9.5 109.5 14.4 124.3 108.6 99 95 Pass
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING
OUR WRITTEN APPROVAL.
Page 1 of 1
Drive Cylinder
Test Method: ASTM D 2937
Permit # 2008-0171
Report Date: 2/10/2021
Client:
Cole Construction
Santa Rosa Beach, FL 32459
3295 W. County Highway 30A F
Project:
4700 Indrio Road
113-21-64-5402
Fort Pierce, FL
4700 Indrio Road
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie,
Phone: 772-878-0072
Port St. Lucie Branch
Page 1 of 2
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING
OUR WRITTEN APPROVAL.
Page 2 of 1
Drive Cylinder
Test Method: ASTM D 2937
Permit # 2008-0171
Report Date: 2/10/2021
Client:
Cole Construction
Santa Rosa Beach, FL 32459
3295 W. County Highway 30A F
Project:
4700 Indrio Road
113-21-64-5402
Fort Pierce, FL
4700 Indrio Road
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie,
Phone: 772-878-0072
Port St. Lucie Branch
Page 2 of 2
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Feb 10, 2021 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.