HomeMy WebLinkAboutTANK SPECS - 2-9-21Quality Steel Corporation AG/UG Propane Tanks
-IpH
14SO wg. AND UP
ear rrnrr-w1"nw1c
APPROXIMATE
ABOVEGROUND/UNDEGROUND
(AG/UG)
V tLIAMLIMNUM3MMv
�«L�^�•-�
WATER
DIAMETER
HEAD
OVERALL
OVERALL
LEG* LEG**
WEIGHT *"QUANTITY
CAPACITY
(OD)
TYPE
LENGTH
5'-8"
HEIGHT
3'
WIDTH SPACING
21-101/2"
1'-11/2" or 3'-11"
(tbs.) FULL LOAD PER stAac
260 108196 16112
*120 wg.
24"
Ellip.
0"
Hemi.
7'-10"
3'-W
1'-5"
4'-11a
480
54
9
W37
0"
Hemi.
9'-7"
10'
16'
3'-8"
4'-2"
4'-5"
1'-5"5'620
1'-8"
V-8"
5'
10'-1"
950
1,800
45
37 { 30
17 15
9
816
6 5
1/2a
Hemi.
1000 wg.
4V
Hemi.
17'-4"
4'-11"
1'-9"
11'-7"
2,650
12
4
461/2"
Ellip.
1450 wg.
23'-11"
4'-11"
1'-9°
16'
3,520
8
4
1990 we.
461/2"
Ellip.
Dlnhenslons and speclacatWns shown are appnmdnsate. tndMdual vessels nhay vary.
' Leg spacing ♦/- 2°. Leg widths and sparing may vwV based on mf& location. Check with Vow salesperson for details. 120, 250, 320 wg. standard tanks
- no holes in legs (one center hole an request). 500 and 28M w& standard tanks - 2 holes 16" on center. 1M v% and up as shown above.
s• full land and stack quanthies vary by S ftW location. Check with Yaw' salesperson for details.
General Sheciflcations
- Conforms to the latest edition of ASME Rules for Construction of pressure Vessels, Section Vill, Division 1.
Complies with NFPA 58.
- Rated at 250 psig from -20' F to 125' F. All vessels registered with National Board.
-Two service options available:
ed with either powder coated phenolic epoxy finish
Option 1: Ready -to -bury underground option, coat
or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite
AG/UG dome.
Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid
applied epoxy primer coat followed by urethane top coat, supplied with steel AG/UG dome.
- All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel.
Updated June 30, 2015
/ AI�A1►�"'MC
n+'t�+�°�vo�aw'f''cA �ei,wa.�,,�''�,
fill
- { • ` iii i .i
:�r« 1,�=-�•�{
J.
31
tIL
seam
1_rA
\ll
el a
low Mo 0 Mr I
Ftrcmme�ttvc � .
Est . �••• ; -,
�M , r n
0
- PROPANE CONSTRUCTION NOTES
1. All pipe and fittings above ground and inside building shall be
SCH. 40 Galvanized ASTM A120 or AGA •approved corrugated
stainless steel •{C.S.S.T.} pipe. ,
2. All polypipe and finings shall be ASTIV D251.3 or ASTM D2517
and shall be bq ei�-o'utside underground at a depth of 18" with
Warning tape and tracer wire.
3. All pipe and meter locations are approximate and subject to
change.'
.4. Ail'polypipe shall be Joined by heat fusion or approved mechanical .
couplings.
• 5. All *galvanized pWo shall be threaded. -
6. Alt pipe shaP I;e pressure tested to 20 PSI fob a period of 24
hours. .
• UNDERGROUND TANK INSTALLATION
� '
d
'
2" to 6"
• DOWNGRADED AWAY
;.; FROM DOMElb
•
__ _:..;,"' -
•
• ••
s • •
1 ANODE CABLE
,
SACR1 FICIAL ANODE •
of • . _
: ,.�•.
.• • •
;, •,•,
•
• (MAGNESIUM BA,G)
• ,
..�
• •�: t
Y
�_
• nEGOLATOR
s
• SHUT GAS OFF AT
• WISER
Q
• • - BARN NAG TAPE '
'� ' _ • - also s
. . . .
GRAbE/CONCRETE SLEEVE �
• • _
9 *woo
R • • • O 0 ••• • • •• O O do�• ~ • ••
do • • . O N • • • •z• !�•
O p • •o �
• ° , uftoanoffovtfo lt-OAS cofttmm n - S ER V ICE LINE • °D
• TRACE WlXi