February 10, 2021
Palm Coast
• Panama City
• Pensacola
Mr. Kevin Spencer
Rockledge
Samson
DR Horton, Inc.
Tampa
1430 Culver Drive NE
wear Palm Beach
Palm Bay, FL 32907
Reference: Conformance Letter for Slab on Grade and Foundations
Lot 69 — Permit 20020063
3213 Trinity Circle, Ft. Pierce, FL
UES Project No.: 0310.2100065.0000
UES DOCS No.: 1838319
Universal Engineering Sciences, Inc. (UES) was retained by DR Horton, Inc. to
inspection the condition of the slab on grade and foundations at the residence under
construction at 3213 Trinity Circle, Ft. Pierce, Florida. We provided observation services
of the already completed slab on grade and foundations and have made every
reasonable effort to ascertain whether those aspects of the project which were inspected
are in conformance with the approved project plans. Two pits were dug beneath the
exterior wall footings and a Proteq Profoscope instrument was used to locate the rebar
in the footings. The dimensions and number of bars found were per the plans. Verticle
steel for masonry wall construction was also located in the exterior footings and found to
be per the plans. A vapor barrier was found beneath the footings. The Profoscope was
also used to find the welded wire fabric in the slab on grade and the thickness and
welded wire were also observed in plumbing cutouts. Our field report is attached.
Based on the information provided above and the to the best of our knowledge
and belief, the slab on grade and foundations for this project were found to be in
compliance with the approved plan documents.
Sincerely,
Universal Engineering Sciences, Inc.
Certificate of Authorization No. 549
Richard E Hoaglin
2021.02.10
11:07:00-05'00'
Richard E. Hoaglin, P.E.
Regional Manager
FL Licensed Engineer No. 48796
820 Brevard Avenue, Rockledge, Florida 32955 (321) 638-0808 Fax (321) 638-0978
www.UniversalEngineering.com
UES Project No: 0310.2100065.0000
UES ROCS No:
UNIVERSAL
UES Report No: 03-134714
ENGINEERING SCIENCES On -Site Time (hrs): 2.50
Geotechnical Engineering i Construction Materials Testing and Inspection Lab Time (hrs): 0.00
Building Cade Compliance Environmental Berices i Facilities Consulting
Travel Time (hrs): 2.50
Total Time (hrs): 5.00
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Inspection Report
Client:
D. R. Horton Homes, Inc.
100 Rialto Place, Ste 800
Melbourne, FL 32901
Project:
Lot 69 Creekside 2 Post Construction Footing Inspection
, Ft. Pierce, County, FL
Date of Activity:
02/09/2021
Technician:
Timothy Hughes
As Requested, a Universal Engineering Sciences Technician was present at the above referenced location for the purpose of
post construction inspection of the house slab. A Proceq Profoscope, was used to verify the presence of reinforcing steel in
footings and slab as per the project plans. 2 areas, one on the north side of the slab and one on the south side of the slab,
were ecavated to below the bottom of the footings. The profoscope detected 2 pieces of reinforcing steel in each of the
footings. WWF was observed in 2 plumbing cut outs in the slab, and scanning of the floor slab detected reinforcement
throughout the slab. The footings measured 18 x 12 inches, as per project plans. Verticle steel coming out of the footings for
the CMU walls, was placed per project plan sheet S-1. A vapor barrier was encountered under the house slab. Images
attached. Compaction test results for the pad are attached.
UNIVERSAL
ENGINEERING SCIENCES
Photograph No. 1: -
Photograph No. 2: -
SITE PHOTOGRAPHS
Post Construction Footing Inspection Photograph Date: Tuesday, February 9,2021
Lot 69 Creekside 2 LIES Project No. 0310.2100065.0020
Ft. Pierce, FL UES Report No. 134714-2
UNIVERSAL
ENGINEERING SCIENCES
Photograph No. 3: -
Photograph No. 4: -
SITE PHOTOGRAPHS
Post Construction Footing Inspection Photograph Date: Tuesday, February 9,2021
Lot 69 Creekside 2 LIES Project No. 0310.2100065.0020
Ft. Pierce, FL UES Report No. 134714-2
UNIVERSAL
ENGINEERING SCIENCES
Photograph No. 5: -
Photograph No. 6: -
SITE PHOTOGRAPHS
Post Construction Footing Inspection Photograph Date: Tuesday, February 9,2021
Lot 69 Creekside 2 LIES Project No. 0310.2100065.0020
Ft. Pierce, FL UES Report No. 134714-2
UNIVERSAL
ENGINEERING SCIENCES
UES Project No 3360.1800087.0000
ES Project
A Universal
No: 222643-1
GF
Engineering
,:Ins..
Report Date: 01/19/2021
'exanos`�
Company
607 Northwest CommodityCove, Pon SL Luais. FL 34986 - P: T72424-3575 - F: 772-924-3580
In -Place Density
Test Report
Client: D.R. HORTON. INC. EAST FLORIDA DIVISION
UES Technician: Johnnie Smith
1430 Culver Drive, NE
Date Tested: 01/12/2021
Palm Bay, FL 32907
Project: CMT CREEKSIDE
Various Locations, Vero Beach, County, FL 32967
Typo of Teat
Area Tested: 3213 Trinity, Lot 69. Foundation Pad
Field: ASTM D-6938 Nuclear Gauge Method
Material: Fill
Laboratory: ASTM D1557 Modified Proctor
Reference Datum: 0 = Top of Final Grade
The tests below meet the 95% minimum compaction mautrement
Tact
Maximum
Optillml
FieldDry
FNId
Soil
Pass
No. Location of Test
Range
Density
(pc)
Moisture
(%)
Density
(pcf)
Mstature
l%1
Compaction
(%)
a
Fail
1 section
1-2h
118.6
10.8
118.2
10.7
100
Pass
2 Election
1-20
118.6
10.8
118.4
10.6
100
Pass
3 Center secaon
i-2it
118.6
Ill
118.7
10.9
100
Pass
Remarks: 04' NCP=50-. > 95 % Compact ion, PASS. HCP tests are empirically correlated to the relative density of the soil.
Permit 8 20020063
Reviewed By
GFA International, Inc
Certificate of Authorization No. 4930
Digitsig
John by Johnally Kentned
Date:
Kent 09:32:24-05'00'
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
To establish a mutual protetlpn to Universal's clients. the Public and ourselves, all reports are submitted as <onTidential properly of our <,—,a all
authonzation forpublicalion of slatembnts, conclusions or esbacls from or regarding Unversal's reports is reserved pending our -non approval.
Pee. 1
SITE PHOTOGRAPHS
Post Construction Footing Inspection Photograph Date: Tuesday, February 9, 2021
Lot 69 Creekside 2 LIES Project No. 0310.2100065.0020
Ft. Pierce, FL LIES Report No. 134714-2