HomeMy WebLinkAboutREVISION PACKET - SCL2010-0421OFFICE USE ONLY:
DATE FILED:
REVISION FEE:
PERMIT # SLC2010-0421
RECEIPT #
PLANNING &DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982=5652
(772)462.1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
DUNKIN' - 903 E PRIMA VISTA BLVD, PORT ST LUCIE, FL 34952
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
HAD TO MOUNT WALL SIGN ON A WIREWAY FOR PROPER INSTALLATION
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: Es000022s
BUSINESS NAME: KEMP SIGNS & SERVICE INC
QUALIFIERS NAME: STEPHEN M KEMP
ADDRESS: 1740 HILL AVENUE
CITY: WEST PALM BEACH STATE: FL
PHONE (DAYTIME): 581-840-6382
OWNER/BUILDER INFORMATION:
NAME: ST LUCIE REALTY GROUP LLC
ADDRESS:469 MARINER DR
CITY: JUPITER
PHONE (DAYTIME: N/A
STATE: FL
ARCHITECT/ENGINEERINFQRMATION:
NAME: CHRISTIAN LANGLEY
ST. LUCIE CO CERT. #: 32o2a
FAX:
ZIP: 33407
561-840-6385
FAX: N/A
ZIP: 33477
ADDRESS: 1200 N FEDERAL HWY #200
CITY: BOCA RATON STATE: FL ZIP; 33432
PHONE (DAYTIME): 1-888-371-3113 FAX: N/A
SLCCC: 9/23/09
Revised 06/30/17
EasySeats
easyseals.com
DESIGN CALCULATIONS
DUNI<IN'
ID LETTERS ON [3AC1<ER
903 E Prima Vista Blvd — Port St Lucie
GENERAL NOTES:
1. Design is in accordance with the Florida Building Code 7th Edition (2020)
for use within and outside the High Velocity Hurricane Zone (HVHZ)I
2. Wind loads have been calculated per the requirements of ASCE 7-16 as
shown herein.
3. These engineering calculations pertain only to the structural integrity of
those systems, components, and/or other construction explicitly
specified herein and/or in accompanying engineering drawings. The
existing host structure (if any) is assumed to be in good condition,
capable of supporting the loaded system, subject to building department
approval. No warranty, either expressed or implied, is contained herein.
4. System components shall be as noted herein. All references to named
components and installation shall conform to manufacturer's or industry
specifications as summarized herein.
S. Where site
conditions
deviate from
those noted herein, revisions may be
required or
a separate
site -specific
engineering evaluation performed.
6. Aluminum components in contact with steel or embedded in concrete
shall be protected as prescribed in the 2015 Aluminum Design Manual,
Part 1. Steel components in contact with, but not encased in, concrete
shall be coated, painted, or otherwise protected against corrosion.
7. Engineer seal affixed hereto validates structural design as shown only.
Use of this specification by contractor, et. Al, indemnifies and saves
harmless this engineer for all costs &damages including legal fees &
apellate fees resulting from deviation from this design.
this dawment has been DI Itdll SI ned
digitally signed and sealed by g y g
Christian Langley, PE on the b Christian
date noted in this digital y
signature. Primed copies or Langley
this dowment a not g Y
considered signed & sealed, & Date: 2021.01.29
the signature must be verified
fMakeble(L3Nnlc IfF0AF15016MFA 12:12:00-05'00'
Index:
Pg 1 Cover
Pg 2 Wind Loads
Pg 3 Anchor Design
t�yunan:��
Eng�tLir %1; eal valid
No.67382
* 0
r STATE OF ;'�kr�y�
Ic;., fi an... Q21
ChrisY'e� # 67382
Easy 5�3�9enriAlcfaeYt Auth # 31124
1200 N Federal Hwy, #200
Boca Raton, FL33432 Easy Seals.�nm Page 1
Easy Seals
/ SCE T16 Design Wind Loads
WALL -MOUNTED SIGNS
Building Specs _
V = 160 mph Basic wind speed (Volt)
Exposure C
Calculations
�a = 9.5 3-sec gust speed power law exponent
ze = 900' Nominal ht. of atmos. boundary layer
Gcpi = 0 Internal pressure coeff
160
mnh - ExD
WALL -MOUNTED SIGNS
ASD WIND
PRESSURES
SIGN
CENTER
I
CORNER
HEIGHT
(Zone 4)
(Zone 5)
15
ft
31.2
psf
39.7
psf
20
ft
33.2
psf
i
42.2
psf
25
ft
34.8
psf
i
44.2
psf
30
ft
36.1
psf
46.0
psf
35
ft
37.3
psf
€
47.5
psf
40
ft
38.4
psf
48.8
psf
45
ft
39.3
psf
50.1
psf
50
ft
40.2
psf
51.2
psf
SS
ft
41.0
psf
I
52.2
psf
60
ft
41.8
psf
53.2
psf
70
ft
35.3
psf
€
70.6
psf
80
ft
36.3
psf
i
72.6
psf
90
ft
37.2
psf
74.5
psf
100
ft
38.1
psf
)
76.1
psf
110
ft
38.8
psf
77.7
psf
120
ft
39.6
psf
79.1
psf
130
ft
40.2
psf
?
80.5
psf
140
ft
40.9
psf
81.7
psf
150
ft
41.5
psf
82.9
psf
175
ft
42.8
psf
85.7
psf
200
ft
44.1
psf
88.1
psf
250
ft
46.2
psf
E
92.3
psf
CALCULATIONS FOR WALL -MOUNTED SIGNS
ASD Load Combo Coeff: 0.6
Kd =
0.85
Directionality factor
Kzt=
1.0
Topographicfactor
1.0
Ground elevation factor
A =
30 sq ft
Tributary area
0.85
28.4
-1.10
.1.40
0.90
30.1
-1.10
-1.40
0.95
31.6
-1.10
-1.40
0.98
32.8
-1.10
-1.40
1.01
33.9
-1.10
-1.40
1.04
34.9
-1.10
-1.40
1.07
35.8
-1.10
-1.40
109
36.6
-1.10
-1.40
1.12
37.3
-1.10
-1.40
1.14
38.0
-1.10
-1.40
1.17
39.2
-0.90
-1.80
1.21
40.4
-0.90
-1.80
1.24
41.4
-0.90
-1.80
1.27
42.3
-0.90
-1.80
1.29
43.2
-0.90
-1.80
1.32
44.0
-0.90
-1.80
1.34
44.7
-0.90
-1.80
1.36
45.4
-0.90
-1.80
1.38
46.1
-0.90
-1.80
1.42
47.6
-0.90
-1.80
1.46
48.9
-0.90
-1.80
1.53
51.3
-0.90
-1.80
Easy Seals
Wall Sign Anchor Design
Structure Dimensions & Loading
Design wind pressure:
Sign type:
Sign size:
CALCULATIONS FOR WALL -MOUNTED SIGNS
P = 46.0 psf
Backer/Wireway
A= 36.0 sgft (entire backer/wireway)
Wall material: Masonry (ASTm coo, isoo psi minl
Anchortype/size: 3/8" Large Diam Tapcon
Ref: Red Head LDT, catalog
Min Embedment: 1.5"
Min edge dist: 4" Min Spacing: 4"
Anchor tensile capacity: Tcap= 229.0 Ib (per anchor)
Check Anchors for Pullout
Total Reaction: Rt = 1654 Ib ... = P"A (entire backer/wireway)
No. of anchors req'd: n = 7.2 total anchors ... = Rt/cap
Total anchors required: 8 total anchors balanced over backer/wireway
OK, typical anchor option shown. Limit to min (10) total.
Ref anchor schedule for other anchor options.
ALLOWABLE: 32'+ 1.5' for each lineal ft over 20'=68.9'
(32' + 44.6'-20'=24.6'x1.5'=36.9')
EXISTING: '
PROPOSED:36'
_��
ES0000229
1740 HILL AVENUE
WEST PALM BEACH, FL
33407
561-840-6382
FAX:561-840-6385
72
PROPOSED
CUSTOMER:
DUNKIN'
903 E. PRIMA VISTA BLVD
PT ST LUCIE, FL
FACES: Orange
Pink(apostrophe)
RETURNS: Gray
TRIM CAP: Bronze
WIREWAY :Painted to match
building
MIN (3) #305M5
PER LETTER
TO MATCH BUILDING
#SxT2^ Self Drilling
screvas to hold JeWellie
trimcap to alum. letter
Minimum 4 per letteF
Dreln Holes in letters if used
30X WITH
°�:�;�hc � i���;�<
ED LIGHTS `.
�T�T� ��
REF ANCHOR SCHEDUL4;, � .� d°$ � � t � Q" �.
FOR MOUNTING OPTIONig�
1Ylllliliallla iLr
BUSHING THROUGH METAL LETTER TO PREVENT
yLrIRE FROM GETTING CUT
PRIMARY ELECTRICAL SOURCE
NEC 600-51/2" MIN. CONDUIT
lhis domment has been
digaalty slgnetl and sealed by
Christian Langley, PE on the
2V LED POWER SUPPLY date noted In this digital
signature. Printed [ogles m
this document a not
ronsidered signed &sealed, &
the slgmmre must be verified
n any eletlmni<[opies.
Consists of channel letters kM.wuraMmsmravwaNu
and disconnect switch.
Digitally signed
Suitable for damp, wet or
outdoor locations. by Christian
Wa��
Langley
All building penetrations
sealed, to comply with Date: 2021.01.29
applicable bldg. code req. 12:12:47-OS'00'
CH00. SCHEDULE
OTY or SPACING
ETE IBks'il or
HOLLOW MgSONRY
3/eC THREADED RODS WITH MIN 2"EMBED IN ADHESIVE
MIN Il6f TOTAL
a/0"TAPCONS (OR EQUIVI WITH 2.5"EMBED
MIN aD)TOTAL
3/B"EXPANSION ANCHORS WITH 3.s"EMBED
MIN I3D)TOTAL
3/2"PLYWOOD
(NO ACCESS BEHIND)
3/8"TOGGLE BOLTB
MIN (10)TOTAL
1/9"WOOD X0.EWS, FULLEMBEO
MIN (16I TOTAL
MEfAL5rUD5/PANErS
k1A METgl6CREWSTO MIN 1Bga STEEL OR D.090°ALUM
MAN 112j TOTAL
HOLLOW WALLa BLOCKING
3/8"THRUBOLTS OR LAGSTO 60UD BLOCKING BEHIND
MIN ISD)TOTAL
Primary wire sae - # 12 THW N
Disconnect switch: at base of sign, 20 amp single pde. Ashonomical time
cock at panel room or photocell
Maximum load -16 amps 720 volts per circuit maximum circuit size 20 amps
per NEC 600-bA
Power supply-120v-277 Multi VoN 60w 12v DC
Illumina}ion-Osram .75watfs per module
Conduit -minimum 1/2
Total sign load- 2.4 amps 120 volh
Total sign circuits - 1
All components shall be U.L approved
Ballasts shall have independent U.L, approval (fused where required)
All installs}ions shall be in compliance wi}h NEC and state, county, or local codes
All signs shall be bonded fo building equipment bonding conductor per NEC 250
DESIGNER: Pam Reeves OCOPYRIGHT 2016 state or: Florida
BY KEMP B3GN & COUnty Of: Pem Beddl
DATE: 09.11.2020 SERVICE. ALL �•—.�
RIGHTS RESERVED -=/ The for0oing document was acknowledged
before me_day of
qLL ELECTR3DgL Ea0000229
U � To 66 u.L. usiEo Electrical Qualifier:
comconfmsgrvD Your Nanse Here, Notary Public
x. pMEET ALL Stephen M. Kemp My Commission EXpires:
c�sTAnogaos
�r
ca5
N mQ
O
u LL w
V
"mm
3 ws'-
=LLm
A�
z��
om°
L'^
6
V
x
it y
V N
9
� N
�n G
� M
O +I
Ev
O W
O
3 N
EiI
r�
mm
it
m Y
=o
cSI
a�
20
n n
N >k
Z' o
O V
va
o
V �
xo
Is a
"v
a-
E
�N
r: °a
N
a�
3
General •Design isina[mNanmwith Nerequiremen[softheFM BldgCode ltA Ed 1202o)forusewithlndounldetheNlghVeloaty Hurti[aneZaneIHVHO.•Thlsenglneeriig cemfiesonlythestmGumlimegdryotthoserystems, componaits,and/orothermmtm[tlon expli[Myspedfietl herein. •Oea�iwl rotes,details,&spetifi[ationsare pmvidedbyand arethesaleresponsibiliryofthe elxtdcal mntra[mc Noelemical renew hasbeen performed and no[erNfiwtion ofsu[h lsintrvMed.•Swnwal designmeetssequlrements of A[I37e-14,AISC360-16, ADM1-15,&NDS-tg
NOteS: as appliOMe.•Steel romponenb shall be mated painted, or athervaise pmfectel again#[wro9on per FBCSe[R03.UR22.6.•Alum components in mnfa[t with steelmembetltletl in mn[rete shall be palnRdmpmteRed as pra[ribed in ADM7-1511a), or plastidneopM�e spoors prwided.•All exposedfasteners shall be 55. or haves p<otecdre mafingfor[orrosion pmRNan.•All welding shall tangly wRh AWS requirements.•Steel welds nDKK elemodes.•Aluminum welds: 9043 fi1kr a0oy.•Alum eRDuslom: 6063-T6 or stmngeo D.N.O.