Loading...
HomeMy WebLinkAboutRevisions FOFFICE USE ONLY: ILE COPY DATE FILED: 3 j % — RERE T# 2001-0630 REVISION FB o r PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE • _ FORT PIERCE,FL 34982-5652 (772)462-1553 FAX(772)462,1578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCAT ADDRESS:ION%S60 ADELFA 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: E-CALCS CORRECTED TO REFLECT TANKLESS WATER HEATER 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: ST.LUCIE COUNTY CERT.#: 8898 BUSINESS NAME: Wyme Buildingorpora ion QUALIFIERS NAMEb South U Suite ADDRESS: �UU wy. CITY; Port St. Lucie STATE: ZIP: PHONE(DAYTIME): (7 72) 8 78-55 13 FAX: 772 878-7656 4. OWNER/BUILDER INFORMATION: NAME: Wynne Building Corporation ADDRESS: 8000 SouthHwy. I S—ui—te CITY: STATE: FL ZIP: 34952 PHONE: (772) 878-5513 FAX: _(772) 878-7656 5. ARCHITECT/ENGINEER INFORMATION: NAME: BRA]--)EN&BRA]--)EN ADDRESS: CITY: STUART STATE: FL ZIP: 34996 PHONE(DAYTIME): (772)287-8258 FAX: Revised 07/22/2014 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential.Performance Method Project Name: WYNNE BUIDLING=THE COTTAGE Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.-PIERCE,FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL,Fort Pierce County: St.Lucie,(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1718.3 sqft.) _ Insulation .Area 2. Single family or multiple family Single-family a.Concrete Block Int Insul,Exterior R=4.1 1478.30 ftz b.Frame-Wood,Adjacent R=11.0 240.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 1 d.N/A R= ft2 10.Ceiling Types (1336.0 sqft.) Insulation Area. 5: Is this'a worst case? Yes a:Under Attic(Vented) R=30.0 1306.00 ft2 6. Conditioned floor area above.grade(ft2) 1306 b.Knee Wall(Vented) R=19.0 30.00 ft2 Conditioned floor area below grade(ft2) 0 c. R= ftz 1.1:Duct s R ft2 . 7. Windows(128.9 sqft.) Description Area -a.Sup:Attic,Ret:Attic,AH:Attic 6 85 a. U-Factor: Sgl,U=0:54 88.89 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 29.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: .13.Heating systems kBtd/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 27.0 HSPF:8.20 SHGC: Area Weighted Average':Overhang Depth: 4:701 ft. Area Weighted Average SHGC: 0.250 14..Hot water systems 8. Floor Types (1306.0 sgft.) Insulation Area a.Electric Tankless Cap:1 gallons. EF:0.600 a.Slab-On-Grade Edge Insulation R=0.0 1306.00 ftz b. Conservation features b.N/A R= f:2 None c.N/A R= ft2 15.Credits None Glass/Floor Area: 0.099 Total Proposed Modified Loads: 42.26 'PASS Total Baseline Loads: 45.95 will hereby certify that the plans and specifications covered by Review of the plans and . 'iE 3"#" this calculation are in compliance with the Florida Energy , specifications covered by this Code. calculation indicates compliance with the Florida Energy Code.: PREP Before Before construction is completed _ r DATE'. 44 this building will be inspected for - compliance with Section 553.968 I hereby certify that this-building,as designed,is in compliance Florida Statutes. ; with the Florida Energy Code.. ''�BDs 'd� . OWNER/ G N� ,� ` BUILDING OFFICIAL: DATE: . DATE:. - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies-as certified factory-sealed in accordance with R403.3:2.1. -Compliance requires an Air Barrier and Insulation Inspection,Checklist in accordance with R402.4.1.1 and-this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 R402.4.1.2). COOS COMPLIANCL FILE . STo L CIE COMaT Y . 4/28/2020 2:21 PM Ener Gau e®USA 6.0.02 Rev.1 -FlaRes2017 FBC 6th Edition 2 Q i o Page 1 of 5 9Y 9 ( ) ( ) pJ _t�#tw 9 1 FORM R405-2017 ,INPUT.SUMMARY:CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE CO Bedrooms: 1 Address Type: Street Address Building Type: User' Conditioned Area: 1306 Lot# Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivisiori: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180 Street:. THE COTTAGE Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE., Family Type: Single-family FL, New/Existing: New,(From Plans) Comment: CLIMATE / Design Temp Int Design Temp', Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 39 90. 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire.House 1306 10576.2 SPACES • Number Name Area Volume Kitchen Occupants: Bedrooms InfillD Finished Cooled Heated 1 MASTER BEDROO 234 1895A No, 0 1 1 Yes Yes Yes 2' DEN 144 1166.4 No 0 1 Yes Yes Yes 3 SINK AREA 42 340.2 No', 0 1 Yes Yes Yes . 4 CLOSET 63 510.3 No; 0 1 No Yes Yes 5. GREAT ROOM 452 3661.2 No, 2 1 Yes Yes Yes 6 MASTER BATH 50 405 No,, 0 1 Yes Yes Yes 7 POWDER 25 202.6 No: 0. 1 No Yes. Yes 8 KITCHEN 232 1879.2 Yes 0 1 Yes Yes Yes 9 LAUNDRY 40 324 No 0 1 No Yes Yes 10, STORAGE 24 192 No. 0 0 1 Yes .Yes Yes FLOORS. # Floor Type Space Perimeter'Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 31 ft 0 234 ftz ___ . 0 1 0 2-Slab-On-Grade Edge Insulatio DEN 24 ft 0 144 ftz 0 1 0 3 Slab-On-Grade Edge Insulatio SINK AREA 7 ft 0 42 ftz ____ 0 1 0 4 Slab-On-Grade Edge Insulatio CLOSET 1 ft 0 63 ftz 0, 1 0 5 Slab-On-Grade Edge-Insulatio GREAT ROOM 32 ft 0 452 ftz 0 1 0 6 Slab-On-Grade Edge Insulatio MASTER BATH , 5 ft 0 50 ftz 0 1` 0 7Slab-On-Grade Edge Insulatio POWDER 1 ft 0 25 ftz ____ 0 1 0 4/29/2020 2:21 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 FORM R405-2017 -INPUT-SUMMARY CHECKLIST REPORT FLOORS # Floor Type. Space Perimeter`Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulatio KITCHEN 38 ft 0 232 ft2 ____ 0 1 0 9.Slab-On-Grade Edge Insulatio LAUNDRY 1 ft 0 40 ft2 0. 1 0 10SIab-On-Grade Edge Insulatio STORAGE 21 ft 0 24 ft? _ 0 0 1 ROOF . Roof Gable Roof Red Solar SA Emitt. Emitt Deck. 'Pitch V. # Type Materials Area Area . Color- Barr Absor. 'Tested Tested Insul. (deg) 1 Hip Metal 1376 ft2 0 w Light N 0..6 No.. 0.7 No .0 18.4 ATTIC . V # Type. Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full.attic Vented 150 1306 ft2 N N CEILING # Ceiling Type . Space R-Value Ins Type Area Framing.Frac Truss Type 1 Under Attic,(Vented) MASTER BEDRO 30 Blown 234 ft2 0.1 Wood _2 UriderAttic(Vented) DEN 30 Blown 144 ft2 0.1 Wood 3 Under.Attic(Vented) SINK AREA 30 Blown 42 ft2 0.1 Wood 4 Under Attic(Vented) CLOSET 30 Blown 63 ft2 0.1 Wood 5 Under Attic(Vented) GREAT ROOM 30 Blown 452 ft2 0.1 Wood 6 Under Attic(Vented) MASTER BATH 30 Blown 50 ft2 0.1 Wood - T Under Attic(Vented) POWDER 30 Blown 25 ft2 0.1 Wood .8 Under Attic(Vented) KITCHEN 30 Blown 232 ft2 0.1 -Wood 9 Under Attic(Vented) LAUNDRY 30:- Blown 40 ft2 0.1 Wood' 10 Under Attic(Vented) STORAGE 30 Blown 24 ft2 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19 -Blown 30 ft2 0.11 Wood WALLS.' Adjacent Cavity Width .Height Sheathing Framing Solar Below Space Et In Et In 1 'S=>N Exterior. Concrete Block=Int InsMASTER BE 4.1 18 .0 8 1 145.5 ft2 0 0 0.3 0 2 W=>E, Exterior Concrete Block-Int InsWASTER BE 4.1 13 0 8 1 105.1 ft2 0 0 0.3 0 3 N=>S Exterior Concrete Block,-Int Insul DEN .4.1 12 0 8 1 97.0 ft2 0 0 0.3 0 4 W=>E Exterior' Concrete Black-Int Insul.;DEN 4A 12 0 8 1 97.0 ft2 0 0 0.3- 0 5' S=>N Exterior . Concrete Block--Int InsLSINk AREA 4.1 7 0 8 1 56.6 ft2 0 0 0.3 0 6 N=>S Exterior Concrete Block-Int InsGREAT ROO 4.1 22 0 8 1 177.8 ft2 0 0 0.3 0 7 W=>E Exterior 'Concrete Block-Int InsiBREAT ROO -4.1 10 0 8 1 80.8 ft2 0 0 0.3 0 8 S=>N ,Exterior Concrete Block.-Int Ins&ASTER BA 4.1 5. 0 8 1 40.4 ft2 0 0 0.3 , 0 9 "N=>S Exterior Concrete Block-Int InsuIKITCHEN 4.1 17 0 8 1 137.4 ft2 -0 0, 0.3 0 _10 .E=>W Exterior Concrete Block Int Insul KITCHEN 4.1 16 0 8' 1 129.3 ft2 0 0 0.3. 0 11 ;S=>N Exterior Concrete Block-Int InsuIKITCHEN 4A 5 0 8 1 40.4 ft2 0 0 0.3 0 4/28/2020 221 PM EnergyGauge®USA 6.0.02(Rev.1)-FI6Res2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space Ft n Ft rea le qnr 12 N=>S Exterior Concrete Block-Int InsulKITCHEN 4.1 35 8 1 282.9 ft2. 0 0 0.3 0 13 N=>S Exterior Concrete Block-Int InsuBTORAGE '4.0999 6 8 48.0 ft2 0• 0 0.3 0 14 N=>S Exterior Concrete,Block-Int InsuSTORAGE 4.0999 5 8 40.0 ft2 0. 0 - 0.3 .0 15 N=>S . Garage Frame-Wood MASTER BE 11 30 8 0 240.0 ft2 0 0.23 0.3 0 DOORS # Omt Door Type .Space Storms U-Value Width Height Area Ft in Ft . In 1 E=>W Insulated KITCHEN None .28 3 6 8 20 ft2 WINDOWS. Orientation shown-is the entered orientation => than ed to Worst Case. Wall Overhang # . Omt ID Frame Panes NFRC U-Factor SHGC Imp_ Area Depth Separation. Int Shade Screening 1 W=>E 2 Metal Low-E Single Yes 0.54 0.25 N 32.4 ft2 1 ft 5 in 1 ft 5 in None None 2 : W=>E 4 Metal Low-E Single Yes 0.54 0.25 N 18.4 ft2 1 ft 5 in 1 ft 5 in None None 3 N=>S 6 Metal Low-E Single Yes 0.54 0.25 N 18.4 ft2 1 ft 5 in 1 ft 5 in None None 4 W=>E 7 Metal Low-E Single Yes 0.55 0.25 N 40.0 ft2 12 ft 0 in 1 ft 5 in None None 5,- S=>N 8 Metal Low-E Single Yes 0.541 0.25 N 6.9 ft2 1_ft 5 in 1 ft 5 in None None 6 E=>W 10 Metal 'Low-E`Single Yes 0.54 0.25 N- 12.8 ft2 1 ft 5 in 1 ft 5 in None None GARAGE # . Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 280 ft2 280 ft2 35 ft 8.1 ft 11 r INFILTRATION # Scope Method SLA- . CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse. Proposed ACH(50) .000257 881.4 48.38 90.99 .0896 5 HEATING SYSTEM. # System Type Subtype Speed Efficiency Capacity Block Ducts. 1 Electric-Heat Pump/ Split Sing[ HSPF:8.2 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:14 29 kBtu/hr cfm 0.8 1 sys#1. 4/28/2020 2.21 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap - Use SetPnt Conservation 1 Electric Tankless Garage 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS -Supply-- - --Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 85 ft2 Attic 35 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabie Thermostat:N Ceiling Fans: Cooling Jan Feb Mar Apr May JunJul Aug Sep Oct Nov [ Dec Heating Jan Feb Mar f Apr E May 4 Jun M'Jul Jul Aug Sepp Oct M.Nov [X Dec Venting Jan Feb Mar [X]Apr [ May [ Jun [ Aug [ Se [X]Oct Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 ' 78 78, 78 PM' 78. 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 -_78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 .68 68' -68 68 68 68 PM 68 68 68 68- 68 68 68 68 6B 68 68 68 Heating(WEH) AM 68 68 68 68 . 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68' 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft.' 0.ft2 Oft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ftz ft 0.3 DEN Default(8 Ibs/sq:ft. ft2 ft 0.3 SINK AREA Default(8 lbs/sgft ft2 ft-, 0.3 CLOSET Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 lbs/sq.ft. ftZ ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 POWDER Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/s .ft: Qft2.. 0 ft. 0:3 •STORAGE 4/26/2020 2:21 PM 'EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5. 2617-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE:402.4.T.I AIR BARRIER AND INSULATION 1NSPECTION COMPONENT CRITERIA Project Name: WYNNE BUIDLING-THE COTTAGE Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL'; Permit Number: U Owner: WYNNE BUILDING CORP. Jurisdiction: w Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the.building:envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints,in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the barrier shall be sealed. shall be aligned with the air barrier. Access.openings,drop downstairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. 'Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having'a thermal resistance'of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope-insulation for framed walls shall be installed in substantial contact and continuous alignment with.the air barrier. Windows;skylights The space between window%doorjambs and framing,and and doors skylights and framing shall be sealed. .Rim joists Rim joists shall include the air barrier. -Rim joists shall be insulated. Floors The air barrier shall be-installed at any exposed edge of Floor framing cavity insulation shall be installedao (including insulation. maintain permanent contact with the underside of . above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom.to the,top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor.retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct'shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned'spa a. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tightand IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily confomis to available space shall gytPnd behind poping and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers'and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated.. Electrical/phone box or The air.barrier.shall be installed behind electrical or communication exterior-walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the subAoor or drywall. Concealed When required to be sealed,concealed fire sprinklers:shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceflon a.In addition,"inspection of log'walls shall be in accordance with the provisions of ICC-400. 4/28/2020 2;21 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant.Software Page 1 of 1 a i. 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY-CARD ESTIMATED ENERGY PERFORMANCE INDEX*= 92 The lower the Energy Performance Index,the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R .6.0 2. Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location Attic 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 1 13.Cooling system: Capacity 29.0 a)Split system SEER 14.0 5. Is this a worst case?(yes/no) 5. Yes b)Single'package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1306 d)Room unit/PTAC EER e)Other 7.Windows,type and area a)U-factor:(weighted average) 7a. 0.543 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.250 14. Heating system: Capacity 27.0 c)Area 7c. 128.9 a)Split system heat.pump : HSPF 8.2 b)Single package heat pump HSPF 8.Skylights o)Electric resistance COP a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace; LPG AFUE f)Other 9. Floor type,insulation level: a)Slab-on-grade(R-value). 9a. 0.0 b)Wood, raised (R-value) 9b. 15.Water heating system c)Concrete; raised(R-value) 9c. a) Electric resistance EF 0.60 b)Gas fired;natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A.Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e)Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 1 OA2. 4.1 f)Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(insulation R-value) 10131. 11.0 2.Masonry(insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a)Under attic 11 a. 30.0 b)Cross ventilation. No b)Single assembly , 11 b. c)Whole house fan No c)Knee walls/skylight walls 11 c. 19.0 d)Multizone cooling credit d)Radiant barrier installed 11d. No e)Multizone heating credit f) Programmable thermostat No "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded)in this home before final inspection. Otherwise,a new'EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: THE COTTAGE `Q City/FL Zip: FT.PIERCE, FL 4/28/2020 2:21:49 PM EnergyGauge®USA 6.0.04(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software"Page 1 of 1"