HomeMy WebLinkAboutSurvey=H H=
:SURVEY:
/II0
LEGAL DESCRIPTION
LOT 5, BLOCK 101-,
LAKEWOOD PARK UNIT 9,
AS RECORDED IN PLAT BOOK 11, PAGES 27A-27D,
PUBLIC RECORDS OF ST.. LUCIE COUNTY, FLORIDA.
LOT 27
IMPROVED
FFE 22.45'
�i l
i0
�.0
CO
LOT 4
r;
FFE— 23.15.;
IMPROVED
NO WELLS
LOCATED
O O
�O O
...... ........_......_....__..._I z z
�C)RAINFIELD,
LOT 26
IMPROVED
FFE=24, 93'
N90°00'00"E(P)
°aS89.49'28"E(M) �,=80.00'(P&M)
.. L_L P ,;ED DNE — 10. '
`(..-I..l_ -- --
11.54'
Ito
LOT 5
` BLOCK 101I
PROPOSED X
1—STORY`\
RESIDENCE`S
23.42' �i
(SUBJECT TO
LOT 25
VACANT
NO WELLS
54
— 30.1911
l0 o
co M
I
�y
x
LOT 6
FFE-24.21
IMPROVED
NO WELLS
0 15 3O- a :
1 INCH'..= 30
-s
WELL
SEPTIC PEr%mllf
LOCATED
a�
0 3.7'cc414.3' y
d'
20.3'
o
,d,
i I
SW.._
-
O .�I
Y
r-! DRALIFIEL 1 f
Z
-
0
750 SOFT
t
0
UNOBSTRUCTED'^.
"r� AREA 01
^a
- ...- .............. _.-........
'00"W
P&M) 80.00,
.............
•um
Y'?: r_'__........_
.mLt:._........._.....':WALL..._.........
t G� ISM
X
s ®i
T..........._SYb�t.f�18.Q-,9F!_......(111)MIX...._.._.._...
(rya
X�h
�- / FND N D
FN NO ID �� P'NO ID
BM EL: 21.58 h`°'+ ,.tip �''� BM EL.21.73
LAKELAND BOULEVARD
70.0' R/W (P)
MODEL: LOT SIZE: = PROPOSED DRAINAGE
1650—B LH 10,400 SQ. FT. 2��. ARROW
BOUNDARY SURVEY CERTIFIED TO: PROPERTY ADDRESS: x = GROUND ELEVATION
CENTURY COMPLETE 7106 LAKELAND BOULEVARD z3.4 = PROPOSED ELEVATION
FORT PIERCE, FL 34951 = PROPOSED CORRUGATED
METAL PIPE
LEGEND & ABBREVIATIONS
I HEREBY CERTIFY THAT THIS SURVEY IS
PSM =PROFESSIONAL SURVEYOR &
1. BASIS OF BEARING - THE SO R U E LN OF LOT 5 •BLOCK 101,
LAKEWOOD PARK UNIT 9, AS RECORDED IN PLAT BOOK 11, IMAGES 27A-27D,
TRUE AND CORRECT TO THE BEST OF
MY KNOWLEDGE, AND THAT THIS SURVEY
MAPPER
LB = LICENSED BUSINESS
PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA, AS BEING N90'00'00"W PER
MEETS THE STANDARDS OF PRACTICE AS
S =
LLICENSED SURVEYOR
PLAT
'
REQUIRED BY CHAPTER 5J-17 FLORIDA
FND _= FOUND
2. DATE OF FIELD SURVEY: 7/7/20; SITE PLAN: 7/10/20, REVISED SITE PLAN
BOARD OF LAND SURVEYORS PURSUANT
SET = SET "LB 7821"
11/16/2020; REVISED FFE 12/14/2020
TO.SECTION 472.027 FLORIDA STATUTES.
IRC = IRON ROD & CAP
N/D = NAIL & DISK
3. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE
C ONE CONCRETE MONUMENT
SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE
DW = DRIVEWAY
SGNNG SURVEYOR.
= SIDEWALK
EC =
EC CONCRETE
4. PROPERTY LINES SHOULD NOT BE ESTABLISHED USING FENCE OR BUILDING TIES.
EP = PAVEMENT
R/W = RIGHT-OF-WAY
5. NO UNDERGROUND INSTALLATIONS OR IMPROVEMENTS INCLUDING BUT NOT LIMITED
TO, BURIED UTILITIES, FOUNDATIONS AND FOOTERS WERe LOCATED.
COV =COVERED
= AIR CONDITIONER (3.5'x3.5' PAD)
6. BASED UPON MY REVIEW OF THE "FLOOD INSURANCE RATE MAP" OF ST. LUCIE
O.E. = DRAINAGE EASEMENT
U.E. = UTILITY EASEMENT
COUNTY UNINCORPORATED AREAS, FLORIDA, COMMUNITY PANEL NO. 12111C0070J,
EFFECTIVE DATE FEBRUARY 16, 2012;, THIS PROPERTY IS LOCATED WITHIN FLOOD
WBF = WOOD BOARD FENCE
ZONE "X" DEFINED AS AREAS DETERMINED TO BE OUTSIDE OF THE 0.2% ANNUAL
CLF = CHAIN LINK FENCE
CHANCE hOODPLAIN.
WVF = WHITE VINYL FENCE
= PLAT
7. NO INSTRUMENTS OF RECORD REFLECTING OWNERSHIP OR .ENCUMBRANCES WERE
�P
M; - MEASURED
PROVIDED, EXCEPT AS NOTED, NOR DID THIS SURVEYOR ABSTRACT THESE LANDS.
DUSTIN W HOLLOWAY, P.S.M. LS 6676
® = WATER METER
8. SURVEY FILE NUMBER: 20-06-077-7106 LAKELAND
H&H SURVEY CONSULTANTS, LLC LB 7821
® = CABLE RISER
® = TELEPHONE RISER
9. ELEVATIONS SHOWN HEREON ARE BASED ON THE NORTH AMERICAN VERTICAL
E AND 7E ORIGINAL
VALID M77HDUT THE SLICENSED
DATUM OF 1988 (NAVD88), AND MORE SPECIFICALLY TO THE FLORIDA PERMANENT
RAISED SEAL W A FLORIDAA LICENSED SURVc'YDR
RAISED
® =ELECTRIC RISER
REFERENCE NETWORK (FPRN) CONTINUOUSLY OPERATING REFERENCE STATIONS
DATE OF SURVEY: December 17, 2020
(0), = POWER POLE
CORS) FLFR, STEW & FLHO.
31 W Broadway, Suite 1001, Oviedo, FL 32765 www.hnhsurvey.com 407.542.4977
i