Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: WYNNE THE STERLING IMPACT BuilderName: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIEjRCE , PermitNumber: \, ,F�L Owner: �Q`�� Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 . b. Frame -Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c, N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1504.0 sgft.) Insulation Area.. a. UnderAttic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b' Knee Wall (Vented) R=19:0 30.00 ft2 Conditioned floorareabelowgrade(ft2) 0 C. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Sgl, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area.Weighted Average SHGC: 0.284 14. Hot water systems 8. Floor Types (1473.5 sqft.) Insulation Area a. Electric Cap:50gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0; 096 Total Proposed Modified Loads:, 47.94 PASS Total Baseline Loads: 48.55 I hereby certify that the plans and. specifications covered by Review of the plans and 4 - this calculation are in compliance with the Florida Energy Code. specifications covered by this indicates -' calculation compliance with the Florida Energy Code. PREPARED BY: ,.. -' - ` Before construction is completed F DATE: - ' 2620 this building will be inspected for compliance with Section 553.908 I hereby certify, that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Co�� .: OWNER/gGF�1,� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance. with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 REM Z1.2)t D ®® CODE COMPLI ?411""l FILE P'T ST. LUCIE COUNTY 4/20/2020 3:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Com ii ofti � Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: _ StreetAddress . Building Type: User ConditionedArea: 1474 Lot# OwnerName: Total Stories: 1 Block/Subdivision: # of Units: 1 WorstCase: Yes PlatBook: BuilderName: WYNNE DEVELOPMENT RotateAngle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family FL , New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp Designi-ocation TMY Site 97.5 % 2.5 % Winter Summer D'egreeDays Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 ' KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # FloorType Space. Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1Slab-On-Grade Edge Insulation BEDROOM 52ft 0 329ft2 ---- 0 1 0 2Slab-On-Grade Edge Insulation WIC 1 ft 0 63ft2 ____ 0 1 0 3Slab-On-Grade Edge Insulation M.BATH 8ft 0 56ft2 ---- 0 1 0 4Slab-On-Grade Edge Insulation KITCHEN 1 ft 0 192ft2 ____ 0 1 0 5 Slab -On -Grade Edge Insulation BATH 5 ft 0 45 ftz ---_ 0 1 0 6Slab-On-Grade Edge insulation BEDROOM2 32.2ft 0 203.5ft2 ____ 0 1 0 7 Slab -On -Grade Edge Insulation ENTRY 7 ft 0 55 ft2 --_- 0 1 0 4/20/2020 3:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)• Compliant Software Page 2 of 5 FORM R405-2017 INPUT -SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value F_ Area JoistR-Value Tile Wood Carpet SSlab-On-Grade Edge Insulation LAUNDRY 6ft 0 42ft2 ____ 0 1 0 9Slab-On-Grade Edge lnsulation GREAT/DINING 46 ft 0 488 ft2 ____ 0 1 0 ROOF Roof Gable Roof Red Solar. SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable orShed Metal 1553 ft2 246 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329ft2 0.1 Wood 2 Under Attic( Vented) WIC 30 Blown 63ft2 0.1 Wood 3 UnderAttic(Vented) M.BATH 30 Blown 56ft2 0.1 Wood' 4 Under Attic (Vented) KITCHEN 30 Blown 192ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45ft2 0.1 Wood 6 UnderAttic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 UnderAttic(Vented) ENTRY 30 Blown 55ft2 0.1 Wood 8 UnderAttic(Vented) LAUNDRY 30 Blown 42ft2 0.1 Wood 9 UnderAttic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall (Vented) BEDROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space file Ff In Ft In Area RAW- Fraction AhS 1 NE=>SW Exterior Concrete Block- Int Insul BEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Int Insul BEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Int Insul BEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 SW=>NE Exterior Concrete Block- Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 2 4.1 16 0 8 0 128.0 W 0 0 0.4 0 7 SE=>NW .Exterior Concrete Block= Int InsuBEDROOM 2 4.1 10 0 8 0 80.0 ft2 .0 0 0.4 0 8 S=>N Exterior Concrete Block - Int InsuBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block- Int InsuBEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block- IntInsul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 DA 0 11 SW=>NE Exterior Concrete Block- Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Intlnsul LAUNDRY 4.1 6 0 8 0 48.0.ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block- Int InsuGGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block- Int InsuIGREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 4/20/2020 3:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 'FORM R405-2017 INPUT SUMMARY- CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame- Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.4 0 DOORS # 0mt DoorType Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ftz WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation IntShade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-ESingle Low-ESingle Low-ESingle Low-ESingle Low-ESingle Yes 1.04 0.29 N Yes 1.04 0.29 N Yes 1.04 0.29 N Yes 1.04 0.29 N Yes 1.11 0.27 N 32.9 ft' 1 ft 0 in- 1 ft 5 in 6.9 W. 1 ft 0 in 1 ft 5 in 24.0 ftz 6 ft 0 in 1 ft 5 in 37.5 ftz 1 ft 0 in 1 ft 5 in 40.0'ft2 8 ft 0 in 1 ft5 in Drapes/blinds None None None Drapes/blinds Exterior5 None None None Exterior5 GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed.Walllnsulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000356 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM' # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER:15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT-WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9gal 120deg None 4/20/2020 3:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS ---- Supply-- --- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 65 ft2 DefaultLeakage . Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: Jan Feb Heating Jan HFeb Cooling H.Jan Mar Mar HX Apr Apr May Ma Jun Jul Aug Sep Oct Nov Dec Feb Mar Jun Jul Aug Sep Oct X 'Nov Dec,Venting Thermosta4Schedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 60 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 .66 66 66 68 68 68 68 68 68 68 PM 68 68 68• 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 .66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68. 68 .68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8lbs/sqft ft2 ft 0.3 M. BATH Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 ibs/sq.ft. ft2 ft 0.3 BATH Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(Ms/sqft ft2 ft 0.3 ENTRY Default(8lbs/sq.ft. ft2 ft: 0.3 LAUNDRY Default 8lbs/s .ft.. ft2. ft 0.3 GREAT/DINING 4/20/2020 3:04 PM EnergyGauge® USA 6.0.02 (Rev; 1) - FlaRes2017 FBC 6th Edition (2017)Compliant Software , Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE A02.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE:STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: cYi w Design Location: FL, Fort Pierce x V COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a. continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any. dropped ceiling/soffit shall be aligned with The insulation in an dropped an/soffit y dro PP ceilin g the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access. openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a.ther_mal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope.insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,' skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.. Floors The air barrier shall be installed at any exposed edge of Floor framing. cavity insulation shall be installed to (including. insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in: contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of -floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Ds. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing hT exterior walls, or insulation. that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on.exterlor wall tubs shall separate them from the showers.and tubs. be insulated. Electrical/phone box or The airbarriershall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers.shall only be sprinklers sealed. in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition,inspection of log walls snail be In accordance with the provisions of IGG-400. 4/20/2020 3:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1. of 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD - ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 5. Is this a worst case? (yes/no) 5. Yes 6. Conditioned floor area (sq. ft.) 6. 1474 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient'(SHGC) 7b. 0.284 c) Area 7c. 141.3 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 b) Single package SEER . c) Ground/water source SEERICOP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace;. LPG AFUE f) Other 9a. 0.0 9b. 15. Water heating system. 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF 10A1. e) Dedicated heat pump with tank EF 10A2. 4.1 f) Heat recovery unit HeatRec% g) Other 1061. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. 19.0 d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy, Conservation, through the "above energy saving features which:will'be installed (or exceeded) in this. home before final inspection. Otherwise,,a new EPL display card will be completed based on installed c ompliant features. Builder Signature: g Date: Address of New Home: THE STERLING City/FL Zip: FT. PIERCE. FL 0'k^ 4/20/2020 3:05:01 PM EnergyGauge® USA 6.0.04 (Rev: 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1