HomeMy WebLinkAboutEnergy Calculation Form & Manual J's FOAM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the -residential Simulated Performance method shall include ❑ This checklist p A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code, This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page) and an input summary checklist that can be used for field verification(usually 4 pages/may be greater). ❑ Energy Performance Level(EPL)Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1- one page) 11 A completed Envelope Leakage Test Report(usually one page) O If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) CnQ EnergyGaugeO-USRCZB v5.1 10/28/2016 11:46:45 AM Page 1 of 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Express Hayden PSL RIGHT NEW Builder Name: Street: ej2 t'1��oiJlP�l�llkst, C Lcl-L I cot Permit Office: City,State,Zip: ST.LUCIE.FL, Permit Number. Owner. Express Homes Jurisdiction: Design Location: FL,ST LUCIE CO INTL County.: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2641.3 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 1289.60 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 999.68 ft.? Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13,0 352.00 ft2 4. Number of Bedroqms 5 d.WA R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1497.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1497.00 f? 6. Conditioned floor area above grade(ft=) 2601 b. N/A R= ft2 Conditioned floor area below grade 0 c,NIA R= ft2 11.Ducts R ft2 7. Windows(252.1 sgft.) Description Area a.Sup:Attic. Ret:Attic,AH:2nd Floor 6 250.5 a. U-Factor Dbl. U=0.34 211.29 ft2 SHGC: SHGC=0.35 b. U-Factor. Dbl,U=0.63 40,80 Its 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 48.0 SEER:15.50 c. U-Factor. N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. NIA ft2 a Electric Heat Pump 46.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.051 ft Area Weighted Average SHGC: 0.345 14•Hot water systems 8. Floor Types (2601.0 sgfL) Insulation Area a.Electric Cap;50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features EF:0.980 b.Floor Over Other Space R=0.0 1035.00 ft2 None C.other(see details) R= 462.00 ft2 15.Credits Pstat Glass/FloorArea: 0.097 Total Proposed Modified Loads: 73.64 PASS Total Baseline Loads: 78.44 I hereby certify that the plans and specifications covered by Review of the plans and kf-THE 5Tq�, this calculation are in compliance.with the Florida Energy specifications covered by this N- = 3 Code. calculation indicates compliance 3' with the Florida Energy Code. PREPARED BY: t - Before construction is completed 'u DATE: s_-; this building will be ins - ' 9 petted for � �•E- S compliance with Section 553.908 ; I hereby certify that this building,as designed,is in compliance Florida Statutes. with the FloridWerg '.�Gbd A�iI OWNER/AGENI _ - BUILDING OFFICIAL: [SATE: � ll j� ���`"' DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested In accordance with Section 803 of RESNET Standards,is not greater than 0.030 On for whole house. 1126/2017 1:12 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM"R405-2014 PROJECT Title: Express Hayden PSL RIGHT Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2601 Lot Owner: Express Homes Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 270 Street: Permit Office: Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: ST. LUCIE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V . Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,ST LUCIE_CO_INTL FL_VERO BEACH_MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl. 2601 21691.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1 st Floor 1104 9715.2 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1497 11976 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 154 ft 0 1104 ft2 , 0.7 0 0.3 2 Floor Over Other Space 2nd Floor r__ _-- 1035 ft2 0 0.7 0 0.3 3 Floor over Garage 2nd Floor 462 ft2 11 0.7 0 0.3 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1751 ft2 0 ft2 Dark 0.9 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1566 ft2 N N 10/28/2016 11:46 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 38 Blown 1497 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>W Exterior Concrete Block-Int Insul 1st Floor 4.1 39.8 0 8.8 0 350.2 ft2 0 0 0.8 0 2 W=>S Exterior Concrete Block-Int Insul 1 st Floor -4.1 36.8 0 8.8 .0 323.8 ft2 0 0 0.8 0 3 S=>E Exterior Concrete Block-Int Insul 1st Floor 4.1 18 0 8.8 0 158.4 ft2- 0 0 0.8 0 4 E=>N Exterior Concrete Block-Int Insul 1st Floor 4.1 19 0 8.8 0 167.2 ft2 0 0 0.8 0 5 S=>E Garage Frame-Wood 1st Floor 13 22 0 8.8 0 193.6 ft2 0 0.8 0 _6 E=>N Garage Frame-Wood 1st Floor 13 18 0 8.8 0 158.4 ft2 0 0.23 0.8 0 7 N=>W Exterior Frame-Wood 2nd Floor 13 39.8 0 8 0 318.4 ft2 0 0.8' 0 8 W=>S Exterior Frame-Wood 2nd Floor 13 40.8 0 8 0 326.4 ft2 0 0.8 0 9 S=>E Exterior Frame-Wood 2nd Floor 13 39.8 0 8 0 318.4 ft2 0 0.8 0 10 E=>N Exterior Frame-Wood 2nd Floor 13 40.8 0 8 0 326.4 ft2 0 0.23 0.8 0 DOORS # Ornt. Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>E Insulated 1st Floor None .4 3 6.8 20.4 W 2 S=>E Insulated 1st Floor None .4 2.8 6.8 19 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.35 46.8 ft2 1 ft 0 in 10 ft 0 in None None 2 N=>W 1 Vinyl Low-E Double Yes 0.63 0.32 40.8 ft2 1 ft 0 in 11 ft 0 in None None 3 S=>E 3 Vinyl Low-E Double Yes 0.34 0.35 31.2 ft2 1 ft 0 in 10 ft 0 in None None 4 S=>E 3 Vinyl Low-E Double Yes 0.34 0.35 2.5 ft2 6.2 ft 0 in 2 ft 0 in None None 5 N=>W 7 Vinyl Low-E Double Yes 0.34 0.35 62.4 ft2 1 ft 0 in 1 ft 0 in None None 6 S=>E 9 Vinyl Low-E Double Yes 0.34 0.35 62.4 ft2 1 ft 0 in 1.5 ft 0 in None None 7 S=>E 9 Vinyl Low-E Double Yes 0.34 0.35 6.0 ft2 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 529 ft2 529 ft2 64 ft 8.8 ft 13 10/2812016 11:46 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000265 1807.6 99.23 186.63 .2446 5 HEATING SYSTEM # System Type Subtype, Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 46 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15,5 48 kBtu/hr 1401 cfm 0.73 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model#. Collector Model# Area Volume FEF None None ft2 DUCTS Supply— ---Return--= Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250.5 ft Attic 75.5 ftz Prop.Leak Free 2nd Floor —,cfm 78.0 cfm 0.03 0.60 1 1 TEMPERATURES ProgramableThermostat:Y Ceiling Fans: Cooling ]Jan [ ]Feb Mar Apr Ij Ma Jun ri Jul Au Se [ ]Oct [ Nov Dec Heatin f X]Jan [X]Feb �X�Mar E,�Apr May ri Jun Jul ri AuJXJ Sep [ ]Oct (X Nov Dec Ventin [ ]Jan [ ]Feb [X Mar [X Apr May Jun JUI Aug Se [X]Oct [X]Nov Dec 10/28/2016 11:46 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM,R405-2014 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 .5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 '78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 '68 68 68 68 68 68 68 68 66 66. Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 . 68 68 68 68 .68 66 66 10/28/2016 11:46 AM EnergyGauge D USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL') DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. - ST. LUCIE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 1289.60 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 999.68 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 352.00 ftZ 4. Number of Bedrooms 5 d.N/A R= ftZ 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic(Vented) R=38.0 1497.00 ftZ 6. Conditioned floor area(ftZ) 2601 b.N/A R= ftZ 7. Windows" Description Area c.N/A R= ftZZ a. U-Factor: Dbl,U=0.34 211.29 ftZ 11.Ducts R ft a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 250.5 SHGC: SHGC=0.35 b. U-Factor: Dbl,U=0.63 40.80 ftZ SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: NIA ftZ a.Central Unit 48.0 SEER:15.50 SHGC: d. U-Factor: N/A ftZ 13.Heating systems kBtulhr Efficiency " SHGC: a.Electric Heat Pump 46.0 HSPF:8.50 Area Weighted Average Overhang Depth: 1.051 ft. Area Weighted Average SHGC: 0.345 8. Floor Types Insulation Area 14.Hot water systems Z a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft EF:0.98 b.Floor Over Other Space R=0.0 1035.00 ftZ c.other(see details) R= 462.00 ftZ b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building THE Sfi Construction through the above energy saving features which will be installed (or exceeded) '04. ;� T`°o,, in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compli t features. Builder Signature: Date: Address of New Home: g� f��(,�(eJ}�t,�e �� City/FL Zip: `'Note: This is nota Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/28/2016 11:46 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: ST.LUCIE,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display,card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans - and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3-air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a.blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be.conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or othet infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm-per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMANVDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. -Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. O R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. O R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. , O R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9,29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 10/28/2016 11:46 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41'C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/.inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100•F to 140°F(38°C to 60°C). • R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy. factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors = which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 10/28/2016 11:46 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 FORM R405-2014 AAN'DATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used'to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is-installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be,selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units;the capacity of equipment may be sized in accordance with good design practice. 0 R403.6.1.2 Heating"equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6,1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. 0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40`F. ❑ R403.9 Swimming pools,'inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9:3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14, 0 R403.9.1'Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that,is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP:gas shall not have continuously burning pilot lights. R463.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. 0 R403.9.2 Time switches. Time switches or other control method,that can automatically turnoff and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. 0 R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. 0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R40$.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. 0 R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do.not have sufficent space,R-10 is allowed. 10/28/2016 11:46 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Express Hayden PSL RIGHT NEW Builder Name: Street: Permit Office: City,State,Zip: ST.LUCIE,FL, Permit Number: Owner: Express Homes Jurisdiction: Design Location: FL,ST_LUCIE_CO_INTL COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. 'Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. .Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 10/2812016 11:46 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Express Hayden PSL RIGHT NEW Builder Name: Street: Permit Office: City,State,Zip: ST.LUCIE,FL, Permit Number: Design Location: FL,ST LUCIE_CO_INTL Jurisdiction: Cond.Floor Area:: 2601 sq.ft. Cond.Volume: 21691 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data ELA: HOUSE PRESSURE I FLOW: I EgLA: ACH: ACH(50): S LA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures: 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off:and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, 0�'CHE ST.gT�t+ performance results demonstrate compliance testing shall be conducted by an with Florida Energy Code requirements in approved third party.A written accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party G -'''*., O conducting the test and provided to l p SIGNATURE: the code official. ' GpD Wt. . PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: 10/28/2016 11,47 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Duct Leakage Test Report Performance Method FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Express Hayden PSL RIGHT NEW Builder Name: Street: Permit Office: City,State,Zip: ST.LUCIE,FL, Permit Number. Design Location: FL,ST LUCIE_CO_INTL Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines 1-4 Duct System Divide by Leakage (Total Conditioned Floor Area) (Qn,Out) f certify the tested-duct.leakage to outside, Qn, is Duct tightness shall be verified by �'f�ESrA�, not greater than the proposed duct leakage Qn O t� specified on Form R405-2014. testing to Section 803 of the RESNET F Standards by an energy rater certified in �` .�% � accordance with Section 553.99, Florida Statutes. Q SIGNATURE: PRINTED NAME: yyE. DATE: BUILDING OFFICIAL: DATE: 10/28/201 6 1 1:47 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1 .Express Hayden Ps! Right HVAC L-oad Calculations for Express Homes fit R H V`z2-Vo,- H- VAP LoAvs Prepared By: Kristin Kelly Florida Breeze 6928 Vickie Circle Suite B West Melbourne, FI 32904 321-951-8767 Friday,October 28,2016 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. Rhva Residential 8&Light.Commercial H- C Loads Elite Soffwrare Development,,lnc A ,Serince Masters,LLC µ Express Hayden Ps1;R glit I -Palmf6ayz �•� Pa e.2 (Project Report --- { .'General P�o'sct lnforrnation Project Title: Express Hayden Psl Right Designed By: Kristin Kelly Project Date: October 28, 2016 Client Name: Express Homes Company Name: Florida Breeze Company Representative: Kristin Kelly Company Address: 6928 Vickie Circle Suite B Company City: West Melbourne, FI 32904 ( Company Phone: 321-951-8767 Reference City: Fort Pierce, Florida Building Orientation: Front door faces South Daily Temperature Range: Medium I Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 i Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference f Winter: 42 39.4 n/a n/a 70 n/a Summer: 95 78 47% 50% 75 53 Cheek Fi Total Building Supply CFM: 1,658 CFM Per Square ft.: 0.637 Square ft. of Room Area: 2,601 Square ft. Per Ton: 671 Volume (ft3) of Cond. Space: 21,691 i °Buildin L�oads _ ,�_ Total Heating Required Including Ventilation Air: 35,738 Btuh 35.738 MBH Total Sensible Gain: 36,441 Btuh 78 % f Total Latent Gain: 10,0.72 Btuh 22 % Total Cooling Required Including Ventilation Air: 46,513 Btuh 3.88 Tons (Based On Sensible+ Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. I Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I I I i f f E:\RHVAC\EXPRESS HAYDEN 2601 PSL RIGHT NEW.rh9 Friday, October 28, 2016, 12:15 PM Rhvac Residential a;Light CommerGial;HVAC Loadsf Elite So�tware,Developmenfi,(act�� Ex re s HayderiPslgRigt t` AIC Serv►ce Masters,LLG .� i .Pa1m'Ba FL�32909" • _ '�=U` - Pa e 3 j Miscellaneous Report f Syste 1 Whole House Outdoor 0 1 Outdoor Outdoor Indoo Indoor Grains ' t wt Data D Bulb Wet Bulb Rel.Num ReROM D 8 (b Difference Winter: 42 - 39.4 80% n/a 70 n/a Summer: 95, 78 47% 50% 75 52.90 Duct Sizir • In•uts Main Trunk Runouts Calculate: Yes Yes Use Schedule: -Yes Yes Roughness Factor: 0.01000 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./l00 ft. Minimum Velocity: 550 ft./min 450 ft./min Maximum Velocity: 600 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. dutside it Data Winter Summer i Infiltration Specified. 0.410 AC/hr 0.210 AC/hr 148 CFM 76 CFM Infiltration Actual: 0.410 AC/hr 0.210 AC/hr Above Grade Volume: X 21,691 Cu.ft. X 21.691 Cut. 8,893 Cu.ft./hr 4,555 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 148 CFM 76 CFM ITotal.Building Ventilation: 0 CFM 0 CFM 1 --System I— Infiltration &Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference) Infiltration&Ventilation Latent Gain Multiplier: 35.94 = (0.68 X 0.990 X 52.90"Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp:,Difference) Winter Infiltration Specked: 0.410 AC/hr(148 CFM), Construction:Average i Summer Infiltration Specified: 0.210 AC/hr(76 CFM), Construction:Average Duet Load Factor Scenarios far S stem 1 At#i Duct Duct Su ac F am ' No. Type Descri•tion Location Ceihn• Leaica•e insulation Area _ _ M©D - __ 1 Supply Attic 16B - ;0:12 — 6— - 702 Nb i` 1 Return Attic 16B 0.12, 6 780 No I , 1 } I 1 . i i i 1 I I E:IRHVACIEXPRESS HAYDEN 2601 PSL RIGHT NEW.rh9 Friday, October28, 2016, 12:15 PM Rhvac ,Resid&Light o me ciahHVAC Loads ` +-i Etrte Software D'eve lopment,lnc:: AIC'S mice Masters,LLCM press liay a Psl Right Load Preview Report Net ft.' San Lai Net San Htg CI9S Act Duct CFM CFM CFM Scope Ton /Ton Area Gain Gain Gain Loss g Size_ Building 3.88 671 2,601 36,441. 10,072 46,513' 35,738 465 1,658' 1,658 System 3.88 67.1 2;601 �M,44.1 10,072, 46.5,13 35,736 4654 1,658, 1,658 ' 17 Duct Latent 3 144 3'144., _ Zone 1 2;601 136;441 6,928 43 369; 35,738 465 1,658 1.658 26x20 6,6,6,6,6, 1-F'ustFloor 1;104' 18,757 3,096 21,853 24.126 3141 8534, 853 '6;6,AA. f 6 2-Second Floor 1,497 17,684 3,83-2, 21,516 11.611,1 1511 805 805{ 5,5.5,5,5, b,5 I - I I I I � I i i i E:IRHVACIEXPRESS HAYDEN 2601 PSL RIGHT NEW.rh9 Friday, October 28,2016, 12:15 PM Rhvap Residential&Lrght Commerq aCHVAC Loads -'� Elite.Softvtare Development,'Inc. I II A/C-Service Mastars,LLG Express Hayden Pst Right l:Palm,Bay,F L 32908w Total Build _Summary Loads _ MnIal•0uaoss Gain Gain Gain E 2A-v-o: Glazing-Double pane low-e(e= 0.60), operable 208.8 1,994 0 2,988 2,988 window, vinyl frame, u-value 0.34, SHGC 0.35 2A-v-d: Glazing-Double pane low-e(e=0.60), sliding 40.8 720 0 789 789 i glass door, vinyl frame, u-value 0.63, SHGC 0.32 2B-v-d: Glazing-Double pane low-e (e= 0.60), fixed sash, 2.5 24 0 35 35 i vinyl frame, u-value 0.34, SHGC 0.35 11J: Door-Metal- Fiberglass Core 39.4 663 0 733 733 13AB-Ofcs: Wall-Block, no blanket or board insulation, 858 4,396 0 3,517 3,517 filled core, siding finish 12C-Osw: Wall-Frame, R-13 insulation in 2 x 4 stud 1491.8 3,802 0 3,597 3,597 cavity, no board insulation, siding finish,wood studs 1613-38: Roof/Ceiling-Under Attic with Insulation on Attic 2601 1,894 0 3,720 3,720 ( Floor(also use for Knee Walls and Partition I Ceilings),Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 22A-pm: Floor-Slab on grade, No edge insulation, no 154 5,088 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil Subtotals for structure: 18,581 0 15,379 15,379 People: 6 1,200 1,380 2,580 Equipment: 3,000 2,700 5,700 Lighting: 0 0 0 Ductwork: 12,596 3,144 15,313 18,457 Infiltration:Winter CFM: 148, Summer CFM: 76 4,561 2,728 1,669 4,397 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 1 Total Building Load Totals: 35,738 10,072 36,441 46,513 Total Building Supply CFM. 1,658 CFM Per Square ft.: 0.637 j Square ft.of Room Area: 2,601 Square ft. Per Ton: 671 Volume(ft3)of Cond. Space: 21,691 +Total Heating Required Including Ventilation Air: G 35,738 Btuh 35.738 MBH 4 Total Sensible Gain: 36,441 Btuh 78 % i Total Latent Gain: 10,072 Btuh 22 % Total Cooling Required Including Ventilation Air: 46,513 Btuh 3.88 Tons (Based On Sensible+Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i i I 4 l E:IRHVACIEXPRESS HAYDEN 2601 PSL RIGHT NEW.rh9 Friday, October 28, 2016, 12:15 PM 1 TRhvac Residential&Light Commercial H1/AC Loads Eli fe Software,Development Inca �AJ.dR�,8, ervice Masters,.LLC' x �_ Express Hayden Psf Right i Paim�a ,F, L 3 0299 s' _ E?age 6 f i S_stem 9 Whole House Summa Loads '_- --- - ry---- -- ---------- __ J Gomponent Area Se � Lat Sen Tetal bear ` tion Quea Loss Gain Garn Ga n 2A-v-o: Glazing-Double pane low-e(e=0.60), operable 208.8 1,994 0 2,988 2,988 window, vinyl frame, u-value 0.34, SHGC 0.35 i 2A-v-d: Glazing-Double pane low-e(e=0.60), sliding 40.8 720 0 789 789 glass door, vinyl frame, u-value 0,63, SHGC 0.32 f 2B-v-d: Glazing-Double pane low-e(e=0.60), fixed sash, 2.5 24 0 35 35 vinyl frame, u-value 0.34, SHGC 0.35 11J: Door-Metal-Fiberglass Core 39.4 663 0 733 733 13AB-Ofcs: Wall-Block, no blanket or board insulation, 858 4,396 0 3,517 3,517 filled core, siding finish 12C-Osw: Wall-Frame, R-13 insulation in 2 x 4 stud 1491.8 3,802 0 3,597 3,597 I cavity, no board insulation, siding finish, wood studs i 166-38: Roof/Ceiling-Under Attic with Insulation on Attic 2601 1,894 0 3,720 3,720 Floor(also use for Knee Walls and Partition Ceilings),Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 22A-pm: Floor-Slab on grade, No edge insulation, no 154 5,088 0 0 0 I insulation below floor, any floor cover, passive, heavy dry or light wet soil Subtotals for structure: 18,581 0 15,379 15,379 j People: 6 1,200 1,380 2,580 Equipment: 3,000 2,700 5,700 Lighting: 0 0 0 Ductwork: 12.596 3,144 15,313 18,457 Infiltration: Winter CFM: 148, Summer CFM: 76 4,561 2,728 1,669 4,397 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 System 1 Whole House Load Totals: 35,738 10,072 36,441 46,513 Cheek Of tyres - - Supply CFM _ _ ._. __ _ - - 1,658. __ - CFM-Per Square ft -- __-- _---- 0-637 Square ft. of Room Area: 2,601 Square ft. Per Ton: 671 f Volume(ft3)of Cond. Space: 21,691 + S:stem L�oa"ti' , Total Heating Required Including Ventilation Air: 35,738 Btuh 35.738 MBH I Total Sensible Gain: 36,441 Btuh 78 % Total Latent Gain: 10,072 Btuh 22 % Total Cooling Required Including Ventilation Air: 46,513 Btuh 3.88 Tons (Based On Sensible+Latent) .Notes 4 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. 1 i iI II i i I � E:IRHVACIEXPRESS HAYDEN 2601 PSL RIGHT NEW.rh9 Friday, October 28, 2016, 12:15 PM Rhvac Residential&Ught Commercial HVAC Loads; EI►te,3dftware Qevel6pment,�lfC., ta AIC Service Moste s LLCb` w 1 `, F pre Hayed n P Pa lc"' ��� E ss s FL'.32909: _E�quo ent Data - System 1 - Whole House _ Cooling System Type: Air Source Heat Pump I Outdoor Model: 25HBC548A**30 Indoor Model: FV4CNB006 Tradename: CARRIER AIR CONDITIONING Outdoor Manufacturer: CARRIER AIR CONDITIONING Description: Air Source Heat Pump AHRI Reference No.: 3646316 Capacity, 50267 Efficiency: 15.5 SEER Heating System Type: Air Source Heat Pump Model: 25HBC548A**30 Tradename: CARRIER AIR CONDITIONING Manufacturer: CARRIER AIR CONDITIONING Description: Air Source Heat Pump Capacity: 45000 Efficiency: 8.5 HSPF This system's equipment was selected in accordance with ACC Manual Manual S equipment sizing data: SODB: 95F, SOWB: 78F, WODB:42F,k8m: 75F, SIRH: 50%, WIDE: 70F, Sen. gain: y 36,441 Btuh, Lat. gain: 10,072 Btuh, Sen. loss: 35,738 Btuh, Entering clg. coil DB:75F, Entering clg.coil WB: 62.5F, Entering htg. coil DB: 70F, Clg,coil TD:20F, Htg. coil TD: 70F, Req. clg.airflow: 1658 CFM, Req. htg. airflow: 465 CFM I f� f I I i If e i i I I i I I I ' I I I_ I E:IRHVAC\EXPRESS HAYDEN 2601 PSL RIGHT NEW.rh9 Friday, October 28, 2016, 12:15 PM Rrjvacy Residential&Light Commercial HVAC Loads, '"Elite Software Development,lnc, i AIC:Service,Masters,LLC Express Hayden Psl Right Pa1ni 6aY.FL 32909 Pa a 8. System I Room Load Summary Htg Mine un Run G!g Glg Min Act Ruom Area Se s Htg t?uc b ct Sens Lat Clg ys No Name .: SF Btuh CFM Size Vel 6tuh Btuh CFM CFM i —Zone 1--- 1 First Floor 1,104 24,126 314 6,6,6,6, - 18,757 3,096 853 853 6,6,6,6, 6,6,6 2 Second Floor 1,497 11,611 151 5,5,5,5, - 17,684 3,832 805 805 5,5,5,5, 5,5,5,5 Duct Latent 3,144 f System 1 total 2,601 . 35,738 465 36,441 10,072 1,658 1,658 ! System 1 Main Trunk Size: 17 in. Velocity: 1,054 ft./min i Loss per 100 ft.: 0.086 in.wg Duct size results above are from Manual D Ductsize. ` Runout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize report for duct velocities and other data. ` wCoolrt S stem Suva ma Coolmg Sensible/Latent Sensible Latent Total Tans S tit 13tuh Btuh BMIJ Net Required: 3.88 78%/22% 36,441 10,072 46,513 I Actual: 4.19 87%/ 13% 43,888 6,378 �J 50,266 ti .E "I mentvData Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: 25HBC548A**30 25HBC548A**30 Indoor Model: FV4CNB006 !!! Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Description: Air Source Heat Pump- Air Source Heat Pump I Efficiency: 8.5 HSPF 15.5 SEER Sound: 0 0 Capacity: 45,000 Btuh 50,267 Btuh Sensible Capacity: n/a 43,888 Btuh Latent Capacity: n/a 6,378 Btuh AHRI Reference No.: n/a 3646316 } 1 This system's equipment was selected in accordance with ACCA Manual S. 1 Manual S equipment sizing data: SODB: 95F, SOWB: 78F,WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: { 36,441 Btuh, Lat. gain: 10,072 Btuh, Sen. loss: 35,738 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62.5F, i !'Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req.clg. airflow: 1658 CFM, Req. htg. airflow: 465 CFM i l - c E:IRHVACIEXPRESS HAYDEN 2601 PSL RIGHT NEW.rh9 Friday,October 28, 2016, 12:15 PM Residential Plans Examiner Review F• Form ��• • A - Design • . • Equipment, D RPER 1.01 8 Mar 10 County, Town, Municipality, Jurisdiction Header Information Contractor Florida Breeze REQUIRED ATTACHMENTS' ATTACHED Manual J1 Form(and supporting worksheets): Yes 0 No❑ Mechanical License# CAC1814113 or MAAE Form?(and supporting worksheets): Yes❑ No NX OEM performance data(heating,cooling,blower): Yes nXX No❑ Building Plan# Manual D Friction Rate Worksheet: Yes❑ No QX Duct distribution system sketch: Yes❑ No QX Home Address(Street or Lot#, Block, Subdivision) ,HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature 42 OF Orientation(Front door faces) South Indoor temperature 70 OF North,East,West, South,Northeast,Northwest,Southeast,southwest Btu/h Total heat loss 35738 Number of bedrooms 5 Sumpter Design Conditions Conditioned floor area 2601 Sq Ft Outdoor temperature 95 OF Number of occupants 6 Indoor temperature 75 OF Windows Roof Grains difference 53 A Gr @ 50 % Rh Eave overhang depth 1 .7 Ft Sensible heat gain 36441 Btu/h Internal shade <— Eave Latent heat gain 10072 Btu/h Blinds,drapes,etc Depth Window Total heat gain 46513 Btu/h Number of skylights 0 EQUIPMENTiHVAC • 1 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type Heat pump Equipment type Heat pump Furnace,Heat pump,Boiler,etc. Air Conditioner,Heat pump,etc Heating CFM 1 401 CFM Model 25HBC548A**30 Model 25HBC548A**30 Cooling CFM 1401 CFM Heating output capacity 45000 Btu/h Sensible cooling capacity 43888 Btulh Heat pumps-capacity at winter design outdoor conditions 6 37 Latent cooling capacity b Btu/h Auxiliary heat output capacity Btu/h Total cooling capacity 50267 Btu/h HVAC DUCT DISTRIBUTION •1 Design airflow 1662 CFM Longest supply duct: 59 Ft Duct Materials Used(circle) Trunk Duct: uct board Flex,Sheet metal, External Static Pressure(ESP) 0.33 IWC Longest return duct: 30 Ft Lined sheet metal, Other (specify) Component Pressure Losses(CPL) 0.25 IWC Total Effective Length(TEL) 89 Ft Branch Duct: Duct board,, lex Sheet metal, Available Static Pressure(ASP) 0.076 IWC Friction Rate: 0.09 IWC Lined sheet metal, Other(specify) ASP=ESP-CPL Friction Rate=(ASP■100)-TEL I declare the load calculation,equipment selection,and duct system design were rigorously performed based on the building plan listed above, I understand the claims made on these forms will be subject to review and verification. Contractor's Printed Name Kristin Kelly Date 8/24/2015 Contractor's Signature1KN W Reserved for use by .. ' The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors,see Fist on page 2 or instructions, ° If abridged version of Manual J is used for load calculation.then verify residence meets requirements,see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. µ:'my Air Conditioning Contractors of America Manual S (Residential Equipment Selection) AcCk Project Information Cooling Design Information Name: Outdoor Design Temp:F 91 'F db Summer City: Outdoor Design Temp: 43 'F db I Winter Stater Altitude: Altitude Adjustment: 1.00 Indoor Design Temp: 75 'F db 50 %RH 63 °F wb Manual J Load Calculations Airflow Calculations Total Load Sensible Latent SHR Heat Loss Design TD for Airflow 18 46513 36441 10072 1 F 0.783 u Design Sensible CFM r 1840 OEM Information Manufacturer. lCarrier Furnace Model#.1 AFUE:� Coil or Fan-Coil Model#: JFV4CNI3006 Condenser Model#: 25HBC548A SEER: 15.5 HSPF: 8.50 (A)Manufacturer's Cooling Performance Data Lower Return Air Outdoor Temperature= 95 (F db) Entering Coil Temperature=75(F db) CFM (F wb) Total BTUH Sensible BTUH Latent.BTUH SHR Rated CFM @ Rated RA Temperature 67 51.800 36,190 157610 0.6986 Rated CFM @ Design RA Temperature 1400 63 48,016 41,374 6,642 0.8617 Rated CFM @ Rated RA Temperature 62 47,070 42,670 4500 0.9065 (B)Manufacturer's Cooling Performance Data Higher Return Air Outdoor Temperature= 95 (F db) Entering Coil Temperature=75(F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM @ Rated RA Temperature 67 53,740 40,740 13,000 0.7581 Rated CFM @ Design RA Temperature 1800 63 50,060 47,012 3,048 0.9391 Rated CFM @ Rated RA Temperature 62 49,140 48,580 —56-0--1 0.9886 Manufacturer's Cooling Performance Data(interpolated) Design Return Air Outdoor Temperature=95(F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR ' F 47.582 F 2.685 0.9466 Excess Latent Capacity Calculation +F 3.694 - -3,694 ' Capacity @ Design CFM/RA IF wb) 1840.5 63 50,267 43,888 6,378 0.873 Equipment Capacity as a%of Design 108.070/6 120.44% 63.339/. Manufacturer's Heat Pump Data Capacity Capacity Balance Supplemental @ 47°F db @ 17°F db Point Heat Required 467280 26,680 1 -23.8 -15.87 . Manufacturer's Furnace Data Input Output Desired Calculated FEATURES Environmentally Sound Refrigerant Technology • PuronN,chlorine-free non-ozone depleting refrigerant • Thermostatic Expansion Valve(TXV)designed to maximize performance with Puron®refrigerant Energy Efficient Operation • Electronically Commutating Motor(ECM)operates efficiently at all speeds • Maximizes efficiency of heating and cooling systems • Ultra low power consumption during fan only operation Indoor Weather Control • Warm,comfortable heating air temperatures • Unmatched humidity control,especially with Carrier's Thermidistat- Control Airflow and Sound Technology • Diffuser air discharge section for high airflow efficiency and quiet,smooth operation • High duct static capability ;mUnique cabin i lestgn that meets;ne�v:stringent:regulanons-for air.1zal ege.Ateefs.requirements of a�%cabtnet.bFikage 1jwhen.teaed_at <1.0-incltes:of-sstatic.press re) Condensate Control and Disposal Technology • Minimal standing waterless microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakage • Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance • Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary line conditions • Tested for condensate disposal at conditions much more severe than those required by AHRI • Primary and secondary drain connections to comply with HUD • All pans constructed of an injection molded glass-filled polycarbonate engineered resin material,with brass drain connections. • High density,super thick cabinetry insulation with vapor barrier • Pre-painted galvanized sheet metal cabinet Heat Transfer Technology • Grooved copper tubing • Lanced sine wave aluminum fins • Discreet refined counter-flow refrigerant circuitry • Bi-flow hard shut-off TXV metering device • ArmorCoat- coil protection available Quality Assisting,Ease of Installation and Service Features • All units multipoise • Provision made for suspending from roof or ceiling joints • Modular cabinet on 003 thru 006 units • Sweat connections for leak free service • Multiple electrical entry for application flexibility(high and low voltage) • Low voltage terminal strip,to safely bold connections within the cabinet • Inspection plate on A-coil models for quick coil cleanliness inspection • Cabinet construction features innovations designed to prevent cabinet sweating Controls'and Electrical Features • Easv Select' Board to maximize comfort,efficiency,and safe heater airflow operation • Easy plug connection provided for quick installation of accessory heater packages • 40VA 208/330v transformer ' • Replaceable 5-amp blade-type auto fuse protects against transformer secondary short Filter Features • Factory supplied filter • Cleanable polyester filter media • Filter"springs"out for easy access-no tools required • Newly improved filter rack area-filter door insulation added for an improved air seal