Loading...
HomeMy WebLinkAbout20036-01M-3-Model1 1 /2" STRAPS TO STRUCTURE STAINLESS STEEL BAND II INSULATED FLEX DUCT 3" SHAFT INSERT 1 1/2" INSULATION RADIUS NOT LESS THAN 1 1/2 x DUCT DIA. BRANCH DUCT BUTTERFLY DAMPER ' OPERATOR ON 1 1/2" STAND-OFF TO ALLOW FOR INSULATION USE ROUND SHEET METAL - DUCT HERE TO LIMIT FLEX DUCT TO 10'-0" IN LENGTH 6"SADDLE - INSULATE BELLS CEILING DIFFUSER (TYP•) TAKE -OFF FITTING 3" SHAFT INSERT STAINLESS STEEL BAND LCEILING NOTE: USE BORDER TYPE 1 WHERE IN HARD CLGS. - BORDER TYPE C WHEN EXPOSED I CEILING DIFFUSER. DIRECTION SECURE FLEX DUCT TO TAKE -OFF INSULATE BELLS. SEE HVAC FLOOR OF AIR I FITTING WITH STAINLESS STEEL I SCREW DRIVER OPERATED BAND PLAN FOR LOCATION FLOW I OF DIFFUSER. BRANCH FLEXIBLE DUCT �I DUCT I STRAP I I DAMPER CEILING I SADDLE I 1 1/2" INSULATION NOTE: USE BORDER TYPE 1 WHERE IN HARD CLGS. - BORDER TYPE C WHEN EXPOSED PROVIDE GASKET BETWEEN TAKE OFF FITTING AND BRANCH DUCT. A FLEX DUCT CONNECTION DETAILS DX COOLING COIL TO VALVE MOISTURE SIGHT GLASS NOTES: 1. PROVIDE ACCUMULATOR IF DEVELOPED LENGTH IS GREATER THAN 50' 2. PROVIDE REFRIGERANT PIPE SIZES RECOMMENDED BY MFG. 3. SEE ALSO REFRIGERANT SYSTEM NOTES CHARGE VALVE W/CAP IF NOT PROVIDED WITH UNIT CONDENSING UNIT SEE DETAIL & SCHEDULE BASE SENSING BULB FILTER DRYER — WITH REPLACEABLE CORE ISOLATION VALVES (TYPICAL) BALL TYPE ISOLATION VALVES IF NOT PROVIDED WITH UNIT E REFRIGERANT PIPING SCHEMATIC RETURN AIR DUCT - SEE PLAN FOR SIZE SUPPLY AiP TRANSITION UP -FLOW AIR UNIT - SEE CONSTRUCT FLLI7VIYI JVrfVI\1 URJL I I\NIYIL rl\V VIVL ILmCf\VLIIVI VYLI\1 LVVV JLIVJVI', FROM I �" X I � X Is" STEEL a ENCLOSE WITH WATER GARD PRIMARY PAN SENSOR #401475B OR SECONDARY DRAIN HOLE SENSOR #401490B I DUCT BOARD - SEAL WITH TAPE a MASTIC. WITH ALARM. WATER GARD, INC. 12211 CEDAR GAP, HOUSTON, TX 77072 (PH 888-652-9800) * PLACE AIR HANDLING UNIT IN THE ROOM SO THAT SERVICE TO THE UNIT & FILTER REPLACEMENT CAN BE ACCOMPLISHED. B VERTICAL AHU DETAIL AHU- I SCALE _ (N.T.S.) SUCTION LINE LIQUID LINE THREADED CAP WITH % "O HOLE DRILLED IN TOP, HAND TIGHTENED. THREADED CAP, HAND TIGHTENED AIR HANDLER SLOPE TO UNIT DRAIN F=pv� — DRAIN PAN 9u CASING SLEEVE UNION NOTE: 1. FILL TRAP MANUALLY ON INITIAL START-UP. 2. PIPE SIZE SHALL NOT BE LESS THAN DRAIN PAN CONNECTION SIZE. 3. A = 1" + FAN SUCTION S.P. B = A / 2 4. ALL CONDENSATE PIPING TO BE PVC. S. INSULATE ALL DRAIN LINES WITH %" ARMAFLEX F I CONDENSATE DRAIN TRAP DETAIL SCALE _ (N.T.S.) a U U 0 O.A. INTAKE o Ln of SUPPLY AIR DUCT - SEE PLAN FOR SIZE PROVIDE TRANSITION TO SUIT MFG. OPENING FLEX MD UP -FLOW AIR HANDLING UNIT - SEE SCHEDULE FILTER VD C.D. —� TRAP FLOOR WALL RETURN GRILL IN WALL DUCT SUPPORT CONSTRUCT PLENUM SUPPORT BASE FRAME-1PROVIDE EMERGENCY OVERFLOW SENSOR FROM I" X I" X" STEEL B ENCLOSE WITH WATER GARD PRIMARY PAN SENSOR #401475B OR SECONDARY DRAIN HOLE SENSOR #40149OB I" DUCT BOARD - SEAL WITH TAPE a MASTIC. WITH ALARM. WATER GARD, INC. 12211 CEDAR GAP, HOUSTON, TX 77072 (PH 888-652-9800) * PLACE AIR HANDLING UNIT IN THE ROOM SO THAT SERVICE TO THE UNIT & FILTER REPLACEMENT CAN BE ACCOMPLISHED. SCALE=(N.TS)I C I VERTICAL AHU DETAIL AHU-2, 3, & 4 SECURE TO STRUCTURE ABOVE AS RECOMMENDED BY SMACNA 1 20 GA GALV. METAL STRAP LJ['/ or � -SHEET METAL SCREW, RIVET OR BOLT TO BOTH SIDES OF DUCT. TYPE 'A' TYPICAL RECTANGULAR DUCT BAND ur 3h11VIL JILC AS HANGER STRAP vLK AD RATED STENER 'i 1 - 1IG 1 TYPICAL ROUND DUCT G I DUCT SUPPORT DETAILS SCALE _ (N.T.S.) DUCT SCHEDULE DUCT DIMENSIONS TYPE INCHES HANGER UP TO 18 A 19 TO 30 A/B 30 TO 60 B NOTE: 8'4' MAX HANGER SPACING SECURE TO STRUCTURE ABOVE AS RECOMMENDED BY SMACNA HANGER ROD SIZE: I TYPE 'B' '11fX%"XW GALVANIZED ANGLE TYPICAL AIR COOLED CONDENSING UNIT. DO NOT LOCATE UNIT WHERE THE UPBLAST WILL STRIKE ANY OVERHANG. LOCATE UNIT MINIMUM OF 2'-0" FROM BUILDING EXTERIOR WALL ANCHOR UNIT TO PAD WITH GALV. STEEL — TIE -DOWN CLIPS, 2 PER SIDE, WITH MIN. 1/4" DIA. EXPANSION BOLTS 0 1 1/2" EMBEDMENT DEPTH, #12 X 3/4" SCREW INTO CASING. SUCTION & LIQUID REFRIGERANT LINES RUN REFRIGERANT LINES SHORTEST DISTANCE TO BLDG. EXTERIOR WALL. SEE PLANS FOR CONTINUATION. PAD TO BE 4" LARGER ALL AROUND THAN UNIT, FURNISHED WITH #4 REBARS AT 6" O.C. BOTH WAYS C� NEOPRENE PAD. (TYPICAL FOR 4) 8" THICK CONCRETE PAD. 4" ABOVE GRADE AND 4" BELOW GRADE MIN. 3000 PSI NOTE: INSTALL TO WITHSTAND 170 MPH WINDS. D I AIR COOLED CONDENSING UNIT DETAIL SCALE _ (N.T.S.) BAND ONE HALF —ROUND MAY BE USED IF DUCT SHAPE IS MAINTAINED 3/8" DIA. THREADED STEEL HANGER ROD SEE PLAN FOR EXHAUST DUCT CONTINUATION AND TERMINATION f DUCT SLEEVE\ ` EXHAUST DUCT FLEX. CONNECTION TO EXHAUST FAN CABINET FAN Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 a Q H r>~ vs w w Q 0 �10 w Q o x Lo W x r0 a x � �o �., w SCALE _ (N.T.S.) F —1 U O� W W W Q O Q:� 0) I` O ;d- U L� rr) W V �ll Y� C� Z Q Q �- Q Q O o W = z O U O z LL O U U Ld J _j L w Li U O E: � w z O C4 o O 0� UPPER ATTACHMENTS Q� O O IN ACCORDANCE WITH ° Iz M LL_ SMACNA DETAILS ENGINEER SEAL ♦♦IIIIIIII//I RUBBER -IN -SHEAR ♦`�♦\C 3;•SVOeO ��e VIBRATION ELIMINATORS �`tF';•��CENS�•.�9�� (TYPICAL FOR ALL 4 • HANGER RODS) yF;' No.60982 •�* -P •; STATE OF . O . <v /011A_ ♦`` CEILING Eric J. Svoboda, PE P.E. No. 60982 THESE DOCUMENTS, ALONG WITH THE CONCEPTS AND OR DESIGNS PRESENTED HEREIN ARE INTEN➢ED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT OF FORT PIERCE ENGINEERING, INC. FOR EXHAUST FAN WHICH THEY WERE PREPARED. REUSE OR IMPROPER RELIANCE ON THESE DOCUMENTS WITHOUT WRITTEN AUTHORIZATION AND ADAPTATION BY FORT PIERCE ENGINEERING, INC. SHALL BE CEILING GRILLE WITHOUT LIABILITY TO THE SAME. COPYRIGHT®2020, FORT PIERCE ENGINEERING, INC. ALL RIGHTS RESERVED. SHEET TITLE MECHANICAL DFTAII q This item has been Digitally signed electronically signed and by Eric Svoboda sealed by Eric J Svoboda, PE, using a SHA-1 authentication Date: 2020.11.11 code. Printed copies of this 1 0.33.25-05'00' document are not considered signed and sealed and the SHA- Adobe Acrobat I authentication code must be verified on any electronic version: copes. 2020.013.20064 H I CEILING CABINET EXHAUST FAN DETAIL SCALE _ (N.T.S.) SCALE _ (N."F.S.) ISSUE DATE: 11-11-2020 DRAWN: EJS APPROVED: EJS DRAWING NUMBER M-3 SHEET 3 OF 3 20036-01