HomeMy WebLinkAbout20036-01M-2-ModelGENERAL NOTES: OUTDOOR AIR CALCULATIONS Y U I. ROUTE REFRIGERANT LINES FROM EACH AHU UP ABOVE CEILING, THRU EXTERIOR WALL a DOWN IN METAL HAT CHANNEL TO RESPECTIVE CU. 2. ROUTE I" CONDENSATE DRAIN LINE FROM EACH AHU DOWN BELOW FLOOR TO EXTERIOR, THEN UP TO DISCHARGE ABOVE GROUND IN LANDSCAPE AREA. 3. PROVIDE MOTORIZED DAMPER 81 VOLUME DAMPER IN EACH O.A. INTAKE. MOTORIZED DAMPER SHALL OPEN WHEN RESPECTIVE SYSTEM CYCLES ON, CLOSE WHEN OFF. 4. LOCATE FILTERS AT BASE OF EACH AHU - NO FILTERS IN RETURN GRILLS. 5. LOCATE INTAKES MIN. 10 FT. FROM EXHAUST / VENTS 81 10 FT HORIZONTALLY FROM PARKING LOT / TRAFFIC AREA. 6. COORDINATE EXACT EQUIPMENT, DUCT AND AIR DEVICE LOCATIONS WITH STRUCTURE AND CEILING / LIGHTING LAYOUT. 7. PROVIDE DUCT DETECTOR TEST SWITCH WITH AUDIBLE & VISUAL INDICATOR UPON DUCT DETECTOR ACTIVATION NEXT TO RESPECTIVE SYSTEM THERMOSTAT. RESPECTIVE SYSTEM SHALL SHUT DOWN UPON DETECTOR ACTIVATION. KEYNOTES: O 12"x12" TRANSFER GRILL WITH FLEX TRANSFER DUCT. nL_vnnnvIrI V ivvv n1 n OUTSIDE AIR SCREEN. (TYPICAL) This item has been Digitally signed electronically signed and by Eric Svoboda sealed by Eric J Svoboda, PE, using a SHA-I authentication Date: 2020.11.11 code. Printed copies of this 10:32:52-051001 document are not considered signed and sealed and the SHA- Adobe Acrobat I authentication code must be verified on any electronic version: copies. 2020.013.20064 AHU 1 25 PPL x 5 CFM = 125 CFM O.A. 1670 SO. FT, x 0.06 CFM = 100.2 CFM O.A. 225.2 CFM O.A. REQUIRED 250 CFM O.A. PROVIDED AHU 2 25 PPL x 5 CFM = 125 CFM O.A. 1960 SO. FT. x 0.06 CFM = 117.6 CFM O.A. 242.6 CFM O.A. REQUIRED 250 CFM O.A. PROVIDED AHU 3 10 PPL x 5 CFM = 50 CFM O.A. 1550 SO. FT. x 0.06 CFM = 93 CFM O.A. 143 CFM O.A. REQUIRED 150 CFM O.A. PROVIDED AHU 4 10 PPL x 5 CFM = 50 CFM O.A. 1600 SO. FT, x 0.06 CFM = 96 CFM O.A. 146 CFM O.A. REQUIRED 150 CFM O.A. PROVIDED z 0 W of Lu Q 0 O z Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design Reg. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 W Q H C!1 a O w w w a W x <0 Q �.. w O U U) cr Z w LLJ _U w 0Q� 0 I` O T U LL Pn W F--I U �l I --I I^ —I I--lli 0 I~� a a o W z _o 0 O Y O Q I--0 Q z O U O Lj J = U F— El� U a� W_ W U O F —D --a L.LJ z O V/1 o O Q� Ir O o a- > ENGINEER SEAL `NN G 3. SVOe O Oti i * No. 60982 0�� STATE OF S' •..... 0• G 0N A 1111111 Eric J. Svoboda, PE P.E. No. 60982 THESE DOCUMENTS, ALONG WITH THE CONCEPTS AND OR DESIGNS PRESENTED HEREIN ARE INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT OF FORT PIERCE ENGINEERING, INC. FOR WHICH THEY WERE PREPARED. REUSE OR IMPROPER RELIANCE ON THESE DOCUMENTS WITHOUT WRITTEN AUTHORIZATION AND ADAPTATION BY FORT PIERCE ENGINEERING, INC. SHALL BE WITHOUT LIABILITY TO THE SAME. COPYRIGHT ®2020, FORT PIERCE ENGINEERING, INC. ALL RIGHTS RESERVED, I SHEET TITLE I HVAC PLAN ISSUE DATE: 11-11-2020 1 DRAWN: EJS APPROVED: EJS I DRAWING NUMBER I M-2 I SHEET 2 OF 3 1 20036-01