Loading...
HomeMy WebLinkAboutCompaction TestUES Project No: Workorder No: Report Date: 3310.2100042.0000 224424-1 02/11/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:Southern Exposure Building Corp.UES Technician:Timothy Watson 8129 9th Hole Drive Port St. Lucie, FL 34952 Date Tested:02/05/2021 Project:Larsen Residence 1101 Saeger Avenue 1101 Saeger Avenue, Fort Pierce, County, FL 34982 Type of Test: Area Tested:1101 Saeger Ave. Ft Pierce.Field:ASTM D-6938 Nuclear Gauge Method Material:Native Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Footing The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Stem-Wall Footing. Northeast corner of proposed building, 0-1 ft 110.2 11.3 107.9 10.9 98 Pass 2 Stem-Wall Footing. Southwest corner of proposed building, 0-1 ft 110.2 11.3 106.8 11.1 97 Pass 3 Stem-Wall Footing. Southeast corner of proposed building, 0-1 ft 110.2 11.3 106.5 10.4 97 Pass 4 Stem-Wall Footing. Northwest corner of proposed building, 0-1 ft 110.2 11.3 107.2 12.1 97 Pass Reviewed By GFA International, Inc Certificate of Authorization No. 4930 John Kent Senior Project Engineer STATE OF FLORIDA Professional Engineer No. 63218 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 Permit: #SLC-2012-0518