HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Century Complete - 1650
Project Address: 70.08 PLUMOSA LN
Permit #:
Is f 1E'.W c JGti �
Occupancy Type: VmWIN 14 Construction Type: C• �IL'jrr-a 1t*0C.0C -
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of. record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.6 ft
5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +19.3,-30.6 Zone 2: +19.3,-53.3 Zone 3: +19.3,-78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5,-44.8 Garage: +31.7/-38.6
7. Design Loads: • Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: VA&WOZ&
8. Were Shear Walls Considered For Structure? Y Yes Not Applicable Explain,> _ 70
9. • Is A Continuous Load Path Provided? Y Yes Not Applicable Explain Why
10. Design Soil Bearing Pressure: 1500 PSF Soil Test Reports Submitted?
:7
DESIGN PROFESSIONAL CERTIFICATION STATEMENT: �A i
I certify that, to the best of my knowledge and belief, the attached plans & specifications g�fo
comply with the applicable structural portions of the building codes currently adopted and enfor t: Lucie
County. I also ��Rfj11�e���Qtb�al elements depicted on these plans provide adequate resistance to the design
forces specif,���;.•••°
No
Signature,�5�'1 O P•
Revised 12/07/2018
�ap James G. Frlling
S
'Print Name
P
` C PE #77824
Cert # & Co. Cert Auth.
COA #27228
Mulhern + Kulp Structural Engineering - 300 Brookside Ave, Ambler, PA 19002
�D�� Company Name & Address