HomeMy WebLinkAboutDesign pressure calcsProperty Information Owner:Francesco Frangella Address:8048 Links Way Port Saint Lucie, FL 34986 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:50 ft. Mean Roof Height:14 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 73 35 7 32.2 -42.3 2 End 60 71 7 31.1 -40.1 3 End 60 35 7 32.7 -43.2 4 End 53 50 7 32.2 -42.2 5 End 53 17 7 33.5 -44.8 6 End 37 63 7 32.4 -42.7 7 End 37 63 7 32.4 -42.7 8 End 26 38 7 33.5 -44.8 9 End 74 63 7 30.9 -39.7 10 End 26 38 7 33.5 -44.8 11 End 26 38 7 33.5 -44.8 12 End 24 24 7 33.5 -44.8 13 End 53 63 7 31.6 -41.2 14 End 53 17 7 33.5 -44.8 15 End 60 71 7 31.1 -40.1 16 End 60 35 7 32.7 -43.2 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1