HomeMy WebLinkAboutCompaction TestUniversal
Engineering
S
Sciences
Company
��RNAT�ONP
UES Project No: 3310.1800474.0000
Workorder No: 224577-1
Report Date: 02/11/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772.924.3580
In -Place Density Test Report
Client: GHO HOMES CORPORATION UES Technician: Mark Rogers
590 NW Mercantile Place Date Tested: 02/09/2021
Port St. Lucie, FL 34986
Project: Port St Lucie CSD/CMT
Various Locations, Port St. Lucie, County, FL
Area Tested: 3712 Tanager Place, Ft. Pierce
Material: Backfill
Reference Datum: 0 = Top of Fill
The tests below meet the 95 % minimum compaction requirement.
Type of Test:
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
Northeast corner of pad
0-1 ft
114.7
10.5
109.8
10.3
96
Pass
2
Southwest corner of pad
0-1 ft
114.7
10.5
110.6
10.3
96
Pass
3
Center of pad
0-1 ft
114.7
10.5
111.3
10.2
97
Pass
Remarks: Above stripped surface 1-2', 2-3' HCP=60+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the
relative density of the soil.
Reviewed By
GFA International, Inc
Certificate of Authorization No. 4930
Digitally signed
J o h n by John Kent
Date:
Ken t 2021.02.11
11:07:53-05'00'
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1