Loading...
HomeMy WebLinkAboutPROEJCT INFO,SAFE MRO Hangar Treasure Coast Fire Alarm System - 082119 Digital SealLEGEND SYMBOL ITEM PART NUMBER DESCRIPTION MANUFACTURER QTY 1 IPA-4000 127-4064 Point Addressable Fire, Releasing Panel /DACT Potter Electric Signal 1 NO SYM 2 ----------12VDC, 18.0 AH Battery ----------2 3 RA-6075 32 Character LCD Remote Annunciator Potter Electric Signal 1 4 PSN-1000E Intelligent Power Expander Potter Electric Signal 1 5 PAD 100-SLCE PAD 100 127 Point SLC Expander Potter Electric Signal 1 NO SYM 6 FIB-1000 Fiber Interface Bridge Potter Electric Signal 2 7 PAD 100-PD PAD 100 Photo Detector Potter Electric Signal 3 8 PAD 100-HD PAD 100 Heat Detector Potter Electric Signal 1 9 PAD 100-DUCTR PAD 100 Duct Detector, Inc Smoke Head Potter Electric Signal 2 NO SYM 10 PAD 100-6B PAD 100 6" Base Potter Electric Signal 4 11 PAD-100-DRTS Remote Test Switch - Duct Detector Potter Electric Signal 2 12 PAD-100-PSDA Pull Station - Fire Alarm, Single Action, Addresable Potter Electric Signal 4 13 RMS-1T-WP-KL Pull Station - Fire Alarm, Single Action, Weatherproof Potter Electric Signal 7 14 RMS-1T-WP-LP-Yellow Foam Release Station, Dual Action, Weatherproof Potter Electric Signal 6 15 3001000 Abort Switch, Maintained , Weatherproof Potter Electric Signal 6 16 UV/IR UV/IR Flame Detector Safe Fire Detection 6 17 TC190 Safecable Linear Heat Detection Cable 190 ° F Safe Fire Detection 3000 18 PAD 100-MIM PAD 100 Micro Input Module Potter Electric Signal 54 19 PAD 100-RM PAD 100 Relay Module Potter Electric Signal 10 20 HS-24WR Wall Horn/Strobe, Red, Multi-cd Potter Electric Signal 2 21 S-24WR Wall Strobe, Red, Multi-cd Potter Electric Signal 8 22 HSLP-24WW-WP Wall Horn/Strobe, Red, Multi-cd Weatherproof Potter Electric Signal 10 23 S-24WR-WP Wall Strobe, Red, Multi-cd, Weatherproof Potter Electric Signal 1 24 CS-24WAR-WP Wall Strobe, Amber, 75-cd, Weatherproof Potter Electric Signal 1 25 PAD-100-NAC Sprinkler Release Module By others 1 26 RCDS-1 Release Circuit Disconnect Switch By others 1 27 ------Sprinkler System Foam Release Solenoid - Connection Only By others 1 28 ------Sprinkler System Tamper Switch - Connection Only By others 15 29 ------Sprinkler System Flow Switch - Connection Only By others 5 OFFICE WALL ELEVATION MRO HANGER ANSUL JET-X-27 214 GPM @ 55 PSI ANSUL JET-X-27 214 GPM @ 55 PSI ANSUL JET-X-27 214 GPM @ 55 PSI ANSUL JET-X-27 214 GPM @ 55 PSI ANSUL JET-X-27 214 GPM @ 55 PSI ANSUL JET-X-27 214 GPM @ 55 PSI HANAGAR WALL ELEVATION HANGAR / OFFICE DEVICE LAYOUT SAFE Fire Protection, Inc.This drawing is the property of SAFE Fire Protection, Inc. and its divisions. It is submitted in confidence and is not to be utilized in any form whatsoever without written consent. SAFE Fire Protection, Inc. shall not be responsible for any alterations, modifications or additions made in the electronic data by the Client or any reuse of the electronic data by the Client or any other party for this project or any other project without the written consent of SAFE. Client shall defend, indemnify, and hold harmless SAFE against any claims, damages, or losses arising out of the reuse of the electronic data without consent of SAFE, and arising out of alterations, modifications, or additions to the electronic data made by anyone other than SAFE. 1 2 3 4 5 6 7 MRO HANGER ANSUL JET-X-27 214 GPM @ 55 PSI ANSUL JET-X-27 214 GPM @ 55 PSI ANSUL JET-X-27 214 GPM @ 55 PSI ANSUL JET-X-27 214 GPM @ 55 PSI ANSUL JET-X-27 214 GPM @ 55 PSI ANSUL JET-X-27 214 GPM @ 55 PSI HANGAR UV/IR COVERAGES SAFE Fire Protection, Inc.This drawing is the property of SAFE Fire Protection, Inc. and its divisions. It is submitted in confidence and is not to be utilized in any form whatsoever without written consent. SAFE Fire Protection, Inc. shall not be responsible for any alterations, modifications or additions made in the electronic data by the Client or any reuse of the electronic data by the Client or any other party for this project or any other project without the written consent of SAFE. Client shall defend, indemnify, and hold harmless SAFE against any claims, damages, or losses arising out of the reuse of the electronic data without consent of SAFE, and arising out of alterations, modifications, or additions to the electronic data made by anyone other than SAFE. ALARM N.C. ALARM COM ALARM N.O. FAULT COM FAULT N.C. GRND 24VDC + NAC #1 Circuit voltage Drop Calculations 15cd H/S 75cd H/S 110cd H/S EP Horn EP Strobe Total Amps 0.11 Max Amps 10.00 Circuit Name Circuit DC Voltage Max Load Device Qty Device Amps Draw Device Qty Device Amps Draw Device Qty Device Amps Draw Device Qty Device Amps Draw Device Qty Device Amps Draw Total Circuit DC Amps #14 Cu Resistance / ft Ohms Length Feet Total Resistance Ohms Total Voltage Drop Last Device Voltage NAC1-SA 24 3.0A 0.058 1 0.108 0.131 1.2 0.75 0.108 0.00326 75 0.2445 0.03 23.97 NAC2-SB 24 3.0A 0.058 0.108 0.131 1.2 0.75 0.000 0.00326 0 0.00 24.00 NAC3-SC 24 3.0A 0.058 0.108 0.131 1.2 0.75 0.000 0.00326 0 0.00 24.00 NAC4-SD 24 3.0A 0.058 0.108 0.131 1.2 0.75 0.000 0.00326 0 0.00 24.00 NAC5-SE 24 3.0A 0.058 0.108 0.131 1.2 0.75 0.000 0.00326 0 0.00 24.00 NAC6-SF 24 3.0A 0.058 0.108 0.131 1.2 0.75 0.000 0.00326 0 0.00 24.00 FACP Circuit voltage Drop Calculations UV/IR Det 15cd Strobe 75cd Strobe 75cd H/S 110cd H/S Total Amps 6.50 Max Amps 10.00 Circuit Name Circuit DC Voltage Max Load Device Qty Device Amps Draw Device Qty Device Amps Draw Device Qty Device Amps Draw Device Qty Device Amps Draw Device Qty Device Amps Draw Total Circuit DC Amps #14 Cu Resistance / ft Ohms Length Feet Total Resistance Ohms Total Voltage Drop Last Device Voltage NAC1-SA 24 3.0A 4 0.058 4 0.058 4 0.108 2 0.108 0.131 0.880 0.00326 300 0.978 0.86 23.14 NAC2-SB 24 3.0A 0.058 0.058 0.108 0.108 5 0.131 0.655 0.00326 500 1.63 1.07 22.93 NAC3-SC 24 3.0A 0.058 0.058 0.108 1 0.108 5 0.131 0.763 0.00326 600 1.956 1.49 22.51 NAC4-SD 24 3.0A 0.058 0.058 0.108 0.108 0.131 0.000 0.00326 0 0 0.00 24.00 NAC5-24VDC 24 3.0A 3 0.7 2.100 0.00326 500 1.63 3.42 20.58 NAC6-24VDC 24 3.0A 3 0.7 2.100 0.00326 500 1.63 3.42 20.58 BATTERY CALCULATION - NAC Panel #1 Qty Module / Device Standby Amps Total Standby Alarm Total Alarm 1 NAC Power Expander 0.006 0.006 0.2000 0.2000 1 SLC Expander 0.060 0.060 0.0600 0.0600 1 Fiber Optic Bridge 0.030 0.030 0.0300 0.030 FIELD DEVICES 1 Relay Module 0.000240 0.00024 0.000240 0.00024 1 Micro Module (Fire Alarm Pull Station)0.000200 0.00020 0.000200 0.00020 1 Micro Module (Flow Switch)0.000200 0.00020 0.000200 0.00020 7 Micro Module (Tamper Switch)0.000200 0.00140 0.000200 0.00140 FIELD DEVICES 1 75 cd Horn/Strobe --0.108 0.11 Total Amps 0.10 0.40 24 Standby Hours 2.35 5 Min. of Alarm 0.03 Minimum Amps Req'd 2.39 Safety Factor 1.20 Minimum Battery Required 2.86 Battery Supplied 7.00 ALARM N.C. ALARM COM ALARM N.O. FAULT COM FAULT N.C. GRND 24VDC + ALARM N.C. ALARM COM ALARM N.O. FAULT COM FAULT N.C. GRND 24VDC + ALARM N.C. ALARM COM ALARM N.O. FAULT COM FAULT N.C. GRND 24VDC + ALARM N.C. ALARM COM ALARM N.O. FAULT COM FAULT N.C. GRND 24VDC + ALARM N.C. ALARM COM ALARM N.O. FAULT COM FAULT N.C. GRND 24VDC + BATTERY CALCULATION - FIRE ALARM CONTROL PANEL Qty Module / Device Standby Amps Total Standby Alarm Total Alarm 1 Main Control Panel 0.130 0.130 0.2200 0.220 1 DACT 0.016 0.016 0.0230 0.023 1 LCD Annunciator 0.020 0.020 0.0250 0.025 1 PSN-1000(E)0.015 0.015 0.0150 0.015 1 Fiber Optic Bridge 0.030 0.030 0.0300 0.030 FIELD DEVICES 3 Photoelectric Detector 0.000300 0.00090 0.000300 0.00090 1 Heat Detector 0.000300 0.00030 0.000300 0.00030 2 Photoelectric Duct Detector 0.000500 0.00100 0.000500 0.00100 2 Remote Test Switch 0.001000 0.00200 0.001500 0.00300 10 Relay Module 0.000240 0.00240 0.000240 0.00240 7 Micro Module (Fire Alarm Pull Station)0.000200 0.00140 0.000200 0.00140 6 Micro Module (Foam Pull Station)0.000200 0.00120 0.000200 0.00120 6 Micro Module (Abort Station)0.000200 0.00120 0.000200 0.00120 5 Micro Module (Flow Switch)0.000200 0.00100 0.000200 0.00100 15 Micro Module (Tamper Switch)0.000200 0.00300 0.000200 0.00300 12 Micro Module (UV/IR)0.000200 0.00240 0.000200 0.00240 6 UV/IR Flame Detector 0.035000 0.21000 0.700000 4.20000 FIELD DEVICES 4 15 cd Strobe --0.058 0.23 6 75 cd Strobe --0.058 0.35 2 75 cd Horn/Strobe --0.108 0.22 10 110 cd Horn/Strobe --0.131 1.31 Total Amps 0.44 6.64 24 Standby Hours 10.51 5 Min. of Alarm 0.55 Minimum Amps Req'd 11.06 Safety Factor 1.20 Minimum Battery Required 13.27 Battery Supplied 15.00 LEGEND SYMBOL ITEM PART NUMBER DESCRIPTION MANUFACTURER QTY 1 IPA-4000 127-4064 Point Addressable Fire, Releasing Panel /DACT Potter Electric Signal 1 NO SYM 2 ----------12VDC, 18.0 AH Battery ----------2 3 RA-6075 32 Character LCD Remote Annunciator Potter Electric Signal 1 4 PSN-1000E Intelligent Power Expander Potter Electric Signal 1 5 PAD 100-SLCE PAD 100 127 Point SLC Expander Potter Electric Signal 1 NO SYM 6 FIB-1000 Fiber Interface Bridge Potter Electric Signal 2 7 PAD 100-PD PAD 100 Photo Detector Potter Electric Signal 3 8 PAD 100-HD PAD 100 Heat Detector Potter Electric Signal 1 9 PAD 100-DUCTR PAD 100 Duct Detector, Inc Smoke Head Potter Electric Signal 2 NO SYM 10 PAD 100-6B PAD 100 6" Base Potter Electric Signal 4 11 PAD-100-DRTS Remote Test Switch - Duct Detector Potter Electric Signal 2 12 PAD-100-PSDA Pull Station - Fire Alarm, Single Action, Addresable Potter Electric Signal 4 13 RMS-1T-WP-KL Pull Station - Fire Alarm, Single Action, Weatherproof Potter Electric Signal 7 14 RMS-1T-WP-LP-Yellow Foam Release Station, Dual Action, Weatherproof Potter Electric Signal 6 15 3001000 Abort Switch, Maintained , Weatherproof Potter Electric Signal 6 16 UV/IR UV/IR Flame Detector Safe Fire Detection 6 17 TC190 Safecable Linear Heat Detection Cable 190 ° F Safe Fire Detection 3000 18 PAD 100-MIM PAD 100 Micro Input Module Potter Electric Signal 54 19 PAD 100-RM PAD 100 Relay Module Potter Electric Signal 10 20 HS-24WR Wall Horn/Strobe, Red, Multi-cd Potter Electric Signal 2 21 S-24WR Wall Strobe, Red, Multi-cd Potter Electric Signal 8 22 HSLP-24WW-WP Wall Horn/Strobe, Red, Multi-cd Weatherproof Potter Electric Signal 10 23 S-24WR-WP Wall Strobe, Red, Multi-cd, Weatherproof Potter Electric Signal 1 24 CS-24WAR-WP Wall Strobe, Amber, 75-cd, Weatherproof Potter Electric Signal 1 25 PAD-100-NAC Sprinkler Release Module By others 1 26 RCDS-1 Release Circuit Disconnect Switch By others 1 27 ------Sprinkler System Foam Release Solenoid - Connection Only By others 1 28 ------Sprinkler System Tamper Switch - Connection Only By others 15 29 ------Sprinkler System Flow Switch - Connection Only By others 5 SAFE Fire Protection, Inc.This drawing is the property of SAFE Fire Protection, Inc. and its divisions. It is submitted in confidence and is not to be utilized in any form whatsoever without written consent. SAFE Fire Protection, Inc. shall not be responsible for any alterations, modifications or additions made in the electronic data by the Client or any reuse of the electronic data by the Client or any other party for this project or any other project without the written consent of SAFE. Client shall defend, indemnify, and hold harmless SAFE against any claims, damages, or losses arising out of the reuse of the electronic data without consent of SAFE, and arising out of alterations, modifications, or additions to the electronic data made by anyone other than SAFE. RISER DIAGRAM Sequence of events Matrix Create an Alarm condition inthe FACPCreate an Supervisorycondition in the FACPCreate an Trouble / Faultcondition in the FACPActivate Alarm Relay in FACPActivate Supervisory Relay inFACPActivate Trouble Relay inFACPTransmit Alarm Condition viaDACT to remote monitoringTransmit SupervisoryCondition via DACT to remotemonitoringTransmit Trouble Conditionvia DACT to remotemonitoringActivate NotificationappliancesShutdown Exhaust ControllerUnitStart Countdown Timer toFoam ReleaseInterrupt Countdown TimerActivate Foam solenoidEvent A B C D E F G H I J K L M N 1 Fire Pull Station X X X X 2 Smoke Detector X X X X 3 Heat Detector X X X X 4 Duct Detector X X X 5 Foam Sys Release Station X X X X X 6 Foam Sys Abort Station X X X X 7 Linear Detection Cable X X X X X 8 UV/IR Detector X X X X X 9 Sprinkler Tamper Switch X X X 10 Sprinkler Flow Switch X X X X 11 Fire Pump Run X X X 12 Fire Pump Fail X X X 13 Loss of AC power X X X 14 Loss of Battery Power X X X 15 Circuit Open X X X 16 Circuit Short X X X 17 Ground Fault X X X LEGEND SYMBOL ITEM PART NUMBER DESCRIPTION MANUFACTURER QTY 1 IPA-4000 127-4064 Point Addressable Fire, Releasing Panel /DACT Potter Electric Signal 1 NO SYM 2 ----------12VDC, 18.0 AH Battery ----------2 3 RA-6075 32 Character LCD Remote Annunciator Potter Electric Signal 1 4 PSN-1000E Intelligent Power Expander Potter Electric Signal 1 5 PAD 100-SLCE PAD 100 127 Point SLC Expander Potter Electric Signal 1 NO SYM 6 FIB-1000 Fiber Interface Bridge Potter Electric Signal 2 7 PAD 100-PD PAD 100 Photo Detector Potter Electric Signal 3 8 PAD 100-HD PAD 100 Heat Detector Potter Electric Signal 1 9 PAD 100-DUCTR PAD 100 Duct Detector, Inc Smoke Head Potter Electric Signal 2 NO SYM 10 PAD 100-6B PAD 100 6" Base Potter Electric Signal 4 11 PAD-100-DRTS Remote Test Switch - Duct Detector Potter Electric Signal 2 12 PAD-100-PSDA Pull Station - Fire Alarm, Single Action, Addresable Potter Electric Signal 4 13 RMS-1T-WP-KL Pull Station - Fire Alarm, Single Action, Weatherproof Potter Electric Signal 7 14 RMS-1T-WP-LP-Yellow Foam Release Station, Dual Action, Weatherproof Potter Electric Signal 6 15 3001000 Abort Switch, Maintained , Weatherproof Potter Electric Signal 6 16 UV/IR UV/IR Flame Detector Safe Fire Detection 6 17 TC190 Safecable Linear Heat Detection Cable 190 ° F Safe Fire Detection 3000 18 PAD 100-MIM PAD 100 Micro Input Module Potter Electric Signal 54 19 PAD 100-RM PAD 100 Relay Module Potter Electric Signal 10 20 HS-24WR Wall Horn/Strobe, Red, Multi-cd Potter Electric Signal 2 21 S-24WR Wall Strobe, Red, Multi-cd Potter Electric Signal 8 22 HSLP-24WW-WP Wall Horn/Strobe, Red, Multi-cd Weatherproof Potter Electric Signal 10 23 S-24WR-WP Wall Strobe, Red, Multi-cd, Weatherproof Potter Electric Signal 1 24 CS-24WAR-WP Wall Strobe, Amber, 75-cd, Weatherproof Potter Electric Signal 1 25 PAD-100-NAC Sprinkler Release Module By others 1 26 RCDS-1 Release Circuit Disconnect Switch By others 1 27 ------Sprinkler System Foam Release Solenoid - Connection Only By others 1 28 ------Sprinkler System Tamper Switch - Connection Only By others 15 29 ------Sprinkler System Flow Switch - Connection Only By others 5 SAFE Fire Protection, Inc.This drawing is the property of SAFE Fire Protection, Inc. and its divisions. It is submitted in confidence and is not to be utilized in any form whatsoever without written consent. SAFE Fire Protection, Inc. shall not be responsible for any alterations, modifications or additions made in the electronic data by the Client or any reuse of the electronic data by the Client or any other party for this project or any other project without the written consent of SAFE. Client shall defend, indemnify, and hold harmless SAFE against any claims, damages, or losses arising out of the reuse of the electronic data without consent of SAFE, and arising out of alterations, modifications, or additions to the electronic data made by anyone other than SAFE.