Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division --- 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 452-1553 Certification for Design Load Cornpiiance Project Name: Project Address: "/ f 2-tom✓ Construction Type: --- V `� t Permit #: Occupancy Type: — 3 INSTRUCTIONS FOR USE: ® This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following . o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida O (� Code 3010-9dition with 2a 5upplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed _Partially Enclosed Open ^l II II1 _ IV �C 3. Risk Category: Exposure Category: B j 4. Design Wind Velocity 70 mph V ASD ___LRFD End Zone Width: ft • 5. Mean Roof Height F,_,O ft Roof Pitch: Z :12 Parapet: �' it 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 1S'MRH, clearly label an all plan openings): C f�c Zone 1:i Zone 2- Zone 3: �' '� Zone 4:�' ZZone 5: 7' r Garage: 7. Design Loads: Floor: A_0 PSF Roof/Dead: 7'5^ PSF RooflUve: � Balcony: H-� PSF 70 Syr A.i o Dock: PSF Uecx: — PSF Stairs: PSF Fence: ` PSF Railings: ' PSF 8. Were Shear Walls Considered For Structure? _&es Not Applicabie Explain Why Not: 9. Is A Continuous Load Path Provided? ✓Yes ,_Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 7-0 D0 PSF Soil Test Reports Submitted? Yes tioT' r��.rzoti' DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify -that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequatresistance ��he design 14 forces specified: Signatur ate, and Seal SLCCDV Form # 020-12 Revised 3/15/12 OS) J'.A—ip— 65. S 51., 5 1-0 k_"Sie Print Name Company Name & Address Cert # & Co. Cert Auth. f 1pk_t xu�o . �3 -/ �� 3 30&Q