HomeMy WebLinkAboutSoil Nuclear Gaugeoy�co
Port St. Lucie
FBPE CA # 4930
521 NW Enterprise Drive
Port St. Lucie, FL 34986
Phone: 772-924-36751 Fax: 772-924-3580
Soil Nuclear Gauge Client: Project: 1 Use dhh� m,
Report Date: 4/8/2016 Oceanfront Builders 15-2546.00
Test Method: ASTM D 6938 3460 SE Dixie highway 4920 Watersong Way, Lot No. 58
Stuart, FL 34997 St. Lucie County, Florida
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry Density
(pcf)
In Place
Moisture
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
N
Remark
1
4/7/16
P-1
N/A
12.2
113.4
11.6
112.5
12
99
95 / 105
Pass
2
4/7/16
P-1
N/A
12.2
113.4
12.0
112.6
12
99
95 / 105
Pass
3
4/7/16
P-1
N/A
1 12.2
1 113.4
1 11.4
113.5
1 12
1 100
1 95 / 105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN
Field Technician
1
Below Slab Grade: Foundation Pad, Northwest Corner
0-1
Troxler T3430 36304
Marquart, Matthew
2
Below Slab Grade: Foundation Pad, Southeast Corner
0-1
Troxler T3430 36304
Marquart, Matthew
3
Below Slab Grade: Foundation Pad, Center Area
0-1
Troxler T3430 36304
Marquart, Matthew
Remarks
Comments
Related Tests
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter".
Gauge calibration data on file with the testing agency.
I Test #
I Related Test #
Test Type
�p111111Mo
00p0i
ENS • • °°�®�®
°
4/8%?$1lh
Donald W. Mohr EP.E.. Lj
,Profew'0i 6gOrrW�# 6Q675
fatielsf�Flji. �e
SS1 OIL
1
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.