Loading...
HomeMy WebLinkAboutSoil Nuclear Gaugeoy�co Port St. Lucie FBPE CA # 4930 521 NW Enterprise Drive Port St. Lucie, FL 34986 Phone: 772-924-36751 Fax: 772-924-3580 Soil Nuclear Gauge Client: Project: 1 Use dhh� m, Report Date: 4/8/2016 Oceanfront Builders 15-2546.00 Test Method: ASTM D 6938 3460 SE Dixie highway 4920 Watersong Way, Lot No. 58 Stuart, FL 34997 St. Lucie County, Florida Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 1 4/7/16 P-1 N/A 12.2 113.4 11.6 112.5 12 99 95 / 105 Pass 2 4/7/16 P-1 N/A 12.2 113.4 12.0 112.6 12 99 95 / 105 Pass 3 4/7/16 P-1 N/A 1 12.2 1 113.4 1 11.4 113.5 1 12 1 100 1 95 / 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN Field Technician 1 Below Slab Grade: Foundation Pad, Northwest Corner 0-1 Troxler T3430 36304 Marquart, Matthew 2 Below Slab Grade: Foundation Pad, Southeast Corner 0-1 Troxler T3430 36304 Marquart, Matthew 3 Below Slab Grade: Foundation Pad, Center Area 0-1 Troxler T3430 36304 Marquart, Matthew Remarks Comments Related Tests Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. I Test # I Related Test # Test Type �p111111Mo 00p0i ENS • • °°�®�® ° 4/8%?$1lh Donald W. Mohr EP.E.. Lj ,Profew'0i 6gOrrW�# 6Q675 fatielsf�Flji. �e SS1 OIL 1 Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1