Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (2)
ICC i EVALUATION s • - Accepted • • Trusted c c SERVICE ICC-ES Report ESR-1474 :0i 'This report is subje6t t6,'renewal 16/2018. DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION:0616 00—SHEATHING DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 25 00—WATER'-RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: 07 27 00-AIR'BARRIERS REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 EVALUATION SUBJECT: ZIP SYSTEM® WALL SHEATHING ICC ICC C ICC C C PMG LISTED Look for the trusted marks of Conformity! . w� "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPQ Award in Excellence" A Subsidiary of �r oEc�ni�Nc ir n � SCC ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other att MRS >itb k�j rtlIbt `1� specifically addressed, nor are they to be construed as an endorsement of the subject of the re'poNf1 0Y� i recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to"an product covered PR �ffFrA N p y p d by the report. remucrRom a�C.aaeaCcr+ Copyright© 2016 ICC Evaluation Service, LLC. All rights reserved. tICC EVALUATION c c SERVICE IMES Evaluation Report ESR-1474 Reissued October 2016 This report is subject to renewal October 2018. www.icc-es.ora 1 (800)423-6587 1 '(562) 699-0543 A Subsidiary of the International Code Council® DIVISION:06 00 00—WOOD, PLASTICS AND 3.0 DESCRIPTION COMPOSITES 3.1 Sheathing Panel: Section:06 16 00—Sheathing, The ZIP System® Wall Sheathing panel is an OSB wood DIVISION:07 00 00—THERMAL AND MOISTURE structural panel having a laminated exterior facer. The PROTECTION Exposure 1 OSB complies with US DOC PS 2 for wood ' Section:07 25 00—Water-resistive Barriers/Weather structural panels. The exterior facer is a medium-density, Barriers phenolic-impregnated, polymer-modified sheet material Section:07'27 00—Air Barriers qualifying as a Grade D water-resistive barrier(required by • Section 2510.6 of the 2012 and 2009 IBC).Thb panels are REPORT HOLDER: nominally 4 feet,wide by 8, 9, 10, 11 or 12 feet long and ' have a square-finished-edge or machined-edge profile. HUBER ENGINEERED,WOODS, LLC When tested in. accordance with ASTM E96 water ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE,SUITE 300 method), the polymer-modified sheet overlay has a' minimum ,vapor permeance of 12 perms 68.6 X CHARLOTTE, NORTH CAROLINA 28262 10-11 kg/(Pa-s-m2)j. Equivalent Water Vapor Transmission (800)933-9220 _ www.huberwood.com rate (WVT) of the polymer-modified sheet overlay is 83.4 g/(24h-m2)when tested at 73.4°F(23°C). EVALUATION SUBJECT: The water-resistive barrier and air barrier properties of the ZIP System® Wall Sheathing Panels are not affected ZIP SYSTEM®WALL SHEATHING when the panels are manufactured to comply'as facing materials for SIPs in accordance with Section R610.3.2 1.0 EVALUATION SCOPE and Table R610.3.2 of the 2015 IRC (Section R613.3.2 Compliance with the following codes: and Table R613.3.2 of the 2012 and 2009.IRC). ■ 2015,-2092 and 2009 International Building Code®(IBC) 3.2 Seam Tape: ® The ZIP SystemTM seam tape'is a self-adhering membrane ■ 2015, 2012 and 2009. International Residential Code tape consisting of acrylic adhesive laminated to a - (IRC) polyolefin backing. The ta�pe'is 0.012 inch (0.30 mm) thick ■ 2015, 2012 and 2009 International Energy Conservation with a minimum width of 3 /4 inches(95.2 mm), and comes Code®(IECC) in rolls of various lengths. " Properties evaluated: 4.0 .INSTALLATION ■ Weather resistance 4.1 General Installation of ZIP System® Wall Sheathing panels must ■ Air leakage. comply with the applicable code, this report and the 2.0 USES manufacturer's published installation instructions. The ® . manufacturer's published installation instructions.must be ZIP System Wall Sheathing panels are, used as available at the jobsite during installation. combination'wall sheathing, air barrier, and water-resistive barrier. This report recognizes the use of ZIP System® ; 4.2 Application: Sheathing, when installed with ZIP System TM flexible 4.2.1 General: The ZIP System®-Wall Sheathing panels flashing seam tape, in walls of Type V construction (IBC) must be attached to wall framing•in accordance with the and dwellings under the IRC, and as an alternate to the applicable' code for wood structural panels, and in water-resistive barrier required in Chapter 14 of the IBC compliance with their panel span rating. The'panels must. and Chapter 7 of the IRC, and to the air barrier required by be installed with the polymer-modified sheet overlay Sections R402.4 and C402.5.1 of the 2015 IECC(Sections` facing the exterior. In accordance with the manufacturer's R402.4 and C402.4.1 of the 2012 IECC; Sections 402.4.1 published.installation instructions, it is recommended that and 502.4.3 of the 2009 IECC). the.square edges of the panels be installed with a gap ]CC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not speciftcally addressed,nor are they to be construed �a as an endorsement of the subject of the report or a recommendation far its use.There is no warranty by iCC Evaluation Service,LLC;express or impiled,as to any finding or other.inatter in this report,or as to any product covered by the report. mvnunw mm.a Copyright 2016 ICC Evaluation service,LLC. All rights reserved. Page 1 of 6 ESR-1474 I Most Widely Accepted and Trusted Page 2 of 6 between adjacent panels .and between panels and alternative to what is specified in, those codes listed in dissimilar materials. All ZIP,Systeme Wall Sheathing panel Section 1.0 of this report, subject to the following seams must be sufficiently sealed with ZIP System seam conditions: tape.All overlay surfaces must be dry and free of sawdust 5.1 This evaluation report and the manufacturer's and dirt prior to application of the ZIP System" seam tape. The ZIP SystemTM seam tape must-extend a minimum of published installation instructions, when required by 1 inch 25.4 mm the code official, must be submitted at the time of ( ) past the panel edge T joint intersections and must be centered within /2 inch (12.7'mm) over the permit application. middle of panel seams.The tape must be pressed firmly to 5.2 The ZIP System® Wall Sheathing panels must be adhere to the,surfaces and,seal the seams.Wrinkles in the manufactured, identified and installed in accordance ZIP System TM seam tape are acceptable unless they with this report .and the manufacturer's published create a leak path to the panel seam. installation instructions. In the event of a conflict 4.2.2 Flashing: Flashing complying with the applicable between the instructions and this report, this report code must be installed at the perimeter of door and must govern. window assemblies, penetrations and terminations of 5.3 The ZIP System® Wall Sheathing panels must be exterior wall assemblies, exterior wall intersections with covered with a code-complying exterior wall covering, roofs, chimneys, porches, decks, balconies, and similar or one .that is recognized in a current ICC-ES projections, and at built-in gutters and similar locations evaluation-report. where moisture could enter the wall. An adhesive-backed 5.4 The OSB sheathing must comply with US DOC PS-2. flashing tape recognized in a 'current ICC-ES evaluation report must be installed to seal all ZIP System Wall 5.5 Fire-resistance-rated construction is outside the Sheathing flashing joints. 'Penetration items must be scope of this report. sealed to the panels. The adhesive-backed flashing tape 6.0 EVIDENCE SUBMITTED must comply with the ICC-ES Acceptance Criteria for Flexible Flashing Materials (AC148) and must be installed 6.1 Data-,in accordance with the ICC-ES Acceptance in accordance with the manufacturer's published Criteria .for Water-resistive Membranes Factory- installation .instructions. See Figures 1 through 7 of this bonded to Wood-based Structural Sheathing, Used as report for typical flashing, water-resistive barrier and air Water-resistive Barriers (AC310), dated May 2008 barrier assembly installation details. (editorially revised August 2015). 4.2.3 Air Barrier Assembly: ZIP System® Wall 6.2 Air leakage data in accordance with ASTM E2357. Sheathing fastened to maximum 24-inch-on-center 7.0 IDENTIFICATION (610 mm), wood wall"framing, using,minimum 6d nails Each ZIP System®Wall Sheathing panel described in this spaced at 6 inches (152 mm) around panel a edges and at report must bear a label that includes the manufacturer's 12 inches (305 in the field, leaving, a inch name (Huber Engineered Woods LLC), the product name, (3.18 gap between panels, .forms an air barrier nominal panel thickness, the evaluation report, number assembly when the gaps between panels and the (ESR-1474),'and the words"Mill 229, Crystal Hill,Virginia'; perimeter of penetrations are sealed with ZIP SystemTM "Mill 228, Easton, Maine"; "Mill 227, Commerce, Georgia"; seam tape as required by Section 4.2.1. The assembly has or"Mill E, Broken Bow, Oklahoma." The OSB sheathing demonstrated a maximum air leakage of 0.0072 cfm/ft� [0.037 U(s•m)] infiltration and 0.0023 cfm/ftz must also bear a label demonstrating compliance with [0.012 U(s•mZ)] exfiltratiori at a pressure differential of US DOC,PS 2 from an approved inspection agency. The 1.57 'psf (75. Pa) when tested in. accordance with ZIP SystemTM seam tape roll -must be labeled with the ASTM E2357. ZIP System logo and the evaluation report number - ESR-1474(see Figure 8). 5.0 CONDITIONS OF USE The ZIP System®Wall Sheathing panel and tape system described in this report complies with, or is a suitable ESR-1474 Most Widely Accepted and Trusted ' Page 3 of 6 bumb1 INSIDE --LOW—PRESSUPZ PDUA RETHANE FOAM OR -h Y IUM E LL� CAULKING. •NECOW GIDED MP_SYSTEMY 11 ING WALL SFEATHMG 3' MANUFACTURER R6UCH.MMt4G 'r. ADHESIVE—BACKED `! FLASHING TAPE Y ADHESIVE—BACKED ,FLAMING TAPE -ROUGH FRAMING WALL.SHEATHING P00URETHANE FDAN DUTGDE IhimE WINDOW HEAD SILL SECTION HEADER SECTION �WINDOW JAMB OUTSIDE - ZIP SYSTEM" WALL SHEATHING ADHESIW-BACKED FLASHING'TAPE INSIDE LOW—PRESSURE POLYURETHANE FOAM JAMS SECTION FIGURE 1—TYPICAL CROSS SECTIONS OF FLANGED WINDOW ESR-1474 I Most Widely Accepted and Trusted Page 4 of 6 OUTWE INSIDE ZP v45'TEII". WAIL SHEATHING lNNDOW.Sii.� / ! % ADHE'.71E-SACRED TAPE FLM1: ROUGH FRak TIdJC' j --PCLIVPOLYU FETE R£TNANE FCAY CALgLXWG . 2AGl:Dad! 1a#4RIESSLf'M POLWRETHANEMAU . i ADHMK-SALVED' fdd6,HEAD FLAMING TAPE R100,FLAS HE _,.\.. ROUGH FRAMING WAIL SHEATHNG 1 DUMDE VISIX �WrAm HEAD v + SILL SECTION HEADER SECTION WINDOW JAMB ?JP SYSTEM' WALL SHEATHING ADHESIVE-BACKED FLASHJIVG TAPE OUTSIDE CAULKING ROUGH OPENING INSIDE LOW-PRESSURE POLYURETHANE FOAM JAMB SECTION FIGURE 2--TYPICAL CROSS SECTIONS OF INSTALLED BRICK MOLD WINDOW ESR-1474 Most I/VidelyAccepted and Trusted Page 5 of 6 / ZIP SYSTEMTM ZIP SYSTEM TM WALL-SHEATHING WALL SHEATHING WALL FRAMING WALL FRAMING ADHESIVE-SACKED FLASHING TAPE FLASHING FASTENER ADHESIVE-BACKED FLASHING TAPE COUNTER.FLASHING METAL FLASHING FLASHING FASTENER J —BASE FLASHING ADHESIVE-BACKED'FLASHING TAPE l FLASHING FASTENER ROOF UNDERLAYMENT(FELT) ADHESIVE-BACKED FLASHING TAPE ,--ROOF UNDERLAYMENT(FELT) ROOF SHEATHING ROOF SHEATHING 1 ti- r—""• 7 ROOF JOIST �—ROOF JOIST FIGURE 3—ROOF-WALL INTERSECTION(OPTION 1) FIGURE 4—ROOF-WALL INTERSECTION(OPTION 2) I Ai1FKC �. MR n%3Atui -pa¢t'filllT GTTAYLAftx� r V7f®31-4•A 7H '-y �'^ 11Mi[Y� Ytt1.fY/f1�G-••_.••K� "Ago4 ikiitlH�DG • � y} w•tcGiA'Ni TT:Ca1'r"SF;R:ASFD NCmlIFmu 6LLAIAn RtMR-`••�` AmmmoOCT.--. AhOORK(t---� fNO1RVf7TW••• iy rum tA+Z7- O.DIIRLtt04f4C RALS \ •'-.•_.•-TI1yyy Sll'[ Q�U�7�EOAMIa 6Wti777 . ARfSVF.d{d6DRALA[f TAY µo+*t�T+wmaoawcnvac \ 1 sAus¢r AwwsnaLcaacaxsFCronw rucgw asaancraata_ I wwi' '; clp+acT�spsuspr wit ll,�,. �!A[Zauwla Cbi7RtlfW1W.••.�. _L.. �' . __ OVArtl t T _ flU�[i 1C1 i- i escsAart T I 1._ T . ` r— �i .'F- uauwru FIGURE 5—TYPICAL WALL-SILL INTERSECTION FIGURE S—TYPICAL WALL-SILL INTERSECTION AND FLASHING DETAILS FOR BRICK SIDING AND FLASHING DETAILS FOR LAPPED SIDING ESR-1474 I Most Widely Accepted and Trusted Page 6 of 6 -Adhesive-Backed Flashing Tape FIGURE 7—INSTALLATION AT PENETRATION OPENING(NON-FIRE-RESISTANCE RATED) , I 1. ' FIGURE 8—LABELING FOR THE ZIP SYSTEM SEAM TAPE ROLL tICC EVALUATION e R. AcceptedICE Most Widely . . Trusted IMES Evaluation Report ESR-1474 FBC Supplement Reissued October 2016 This report is subject to renewal October 2018. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES Section:06 16 00—Sheathing DIVISION: 07'00 00—THERMAL AND MOISTURE PROTECTION Section: 07 25 00—Water-Resistive Barriers/Weather Barriers Section:07 27 00—Air Barriers 'REPORT HOLDER:' HUBER ENGINEERED WOODS;LLC ONE RESOURCE SQUARE 10926 DAVID TAYLOR DRIVE,SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 (800)933-9226 www.hubeMobd.com EVALUATION SUBJECT:, ZIP SYSTEM®WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The 'purpose of this evaluation report supplement is to indicate that ZIP System® Wall Sheathing panels, recognized_ in ICC-ES master evaluation report ESR-1474, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■•2014 Florida Building Code=Building ■ 2014 Florida Building Code—Residential 2.0 CONCLUSIONS The ZIP System®Wall Sheathing panels, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, comply with the 2014 Florida Building Code—Building and the 2014 Florida Building Code—Residential, provided the design and installation are in accordance with-the International Building Code®provisions noted in the master report. Use of the ZIP System®Wall Sheathing panels for compliance with the High-Velocity Hurricane Zone provisions of the 2014-Florida Building Code—Building and the 2014 Florida Building Code—Residential has not been evaluated, and is outside the scope of this evaluation report'. For products falling under Florida Rule 9N-3, verification that the report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity(or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued October 2016. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to he construed as an endorsement of the subject of the report or a recommendationfor.its use.,There is no warranty by ICC Evaluation Service,LLC,,express or implied,as W '® to any finding or other matter in this report,or as to arty product covered by the report. a �� Copyright O 2016 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 1 e ICC EVALUATION SERVICE Most Widely Accepted . . ICC-ES Environmental .Report VAR-1012 . Reissued September 2015 This report is subject to renewal September 2017. www.1cc-es.orglep- 1 (800)423-6587 1 (562)'69970543. A Subsidiary of the International Code Council® DIVISION:06 00 00—WOOD, PLASTICS AND 2013 California Green Building Standards' Code 'COMPOSITES (CALGreen),Title 24, Part 11 (see Table 3 for details) Section:0612 00--Structural,Panels National Green Building'. Standard (ICC 700-2008) Section:06 16 00—Sheathing (see Table 4 for details) DIVISION:07 00 00 THERMAL AND MOISTURE . National . Green Building Standard. (ICC 700-2012) ' PROTECTION. (see Table 5'for details) Section:07 21 00—Thermal Insulation LEED for Homes 2008(see Table 6 for details) Section:07'25 00—Water-Resistive Barriers[Weather Barriers e LEED v4 for Homes Design and Construction (see Section:07 27 00—Air Barriers Table 7 for details) REPORT HOLDER:' LEED 2009 for New Construction and Major Renovations (see Table 8 for details) LEED 2009 for HUBER ENGINEERED WOODS,LLC Schools New Construction and Major Renovations (see 10925 DAVID TAYLOR DRIVE . Table 9 for details) ..CHARLOTTE-,,NORTH CAROLINA 28262 LEED v4 for Building Design and Construction (BD+C) ,(800)933-9220 (See Table 10 for details) wwwihuberwood.com .,ANSI/GBI 01-2010 — Green Building Assessment EVALUATION SUBJECT: Protocol for Commercial Buildings (see Table 11 for .details) ' ADVANTECH®(AT-SERIES)SHEATHING SPAN; 2,0. USES ADVANTECH®(AT-SERIES)FLOOR SPAN;ZIP SYSTEM® ROOF SHEATHING;ZIP SYSTEM®WALL SHEATHING;. AdvanTech® (AT-Series) Sheathinj Span, AdvanTech® ZIP SYSTEM®R-SHEATHING(INSULATING SHEATHING) (AT-Series) Floor Span, ZIP.System Roof Sheathing and . 'ZIP.,System Wall Sheathing are used for a variety of 1.0 EVALUATION SCOPE interior and exterior-framing and sheathing applications. Compliance with the following evaluation criteria: . ZIP Systems R-Sheathing panels are used 'as combination wall sheathing and continuous insulation in • ICC-ES Environmental Criteria for Determination of Bio- conventional wood-framed wall construction. based Material Content(EC102), dated March 2012. 3.0 DESCRIPTION ' • ICC-ES Evaluation Guideline for Determination of ;Source of Recovery, Extraction, Harvest and AdvanTech (AT-Series)Sheathing Span and AdvanTech Manufacture for Materials or Products (EC114), dated (AT-Series) Floor Span wood structural panels are. March 2012: Exposure 1 briented strand board (OSB) panels manufactured with strands from a single wood species or a • ICC-ES Environmental Criteria for Determination of combination of wood species blended with an exterior-type Formaldehyde Emissions of Composite Wood and adhesive system to comply with U.S. DOC PS-2 and the Engineered Wood 'Products (EC108), dated March applicable ICC-ES report as indicated in Table,1. '2012. ZIP Systems Roof Sheathing and ZIP Systems Wall • ICC-ES Environmental Criteria 'for Determination of Sheathing wood structural panels are OSB panels with Certified Wood and Certified Wood r Determi Products laminated,. resin-impregnated, polymer-modified sheet (ECified dated March 2012. material manufactured to comply with U.S. DOC PS-2 and the applicable ICC-ES reports as indicated in Table 1. The Compliance eligibility with the applicable sections of panels are installed with ZIP Systems self-adhering the following green building rating systems,standards membrane tape. The tape is outside the scope of this and codes: evaluation report. • 2012 International Green Construction Code (IgCC) ZIP Systems R-Sheathing is an insulated sheathing (see Table 2 for details) made by combining .7/16-inch-thick ZIP Systems Wall ICC-ES Verification ofA1tibutes Reports are issued tinder the ICC-ES VAR Environmental Piogram.These reports are not to be construed as representing aesthetics or any other W attributes not specifically addressed,nor are they to he construred ar an endorsement of the subject of the report or a recommendation foi its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. Copyright 0 2016 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 6 VAR-1012 I Most Widely Accepted and Trusted Page 2 of 6 Sheathing as described in ESR-1474 with a layer of 5.2 ICC-ES EC114. [Evaluation applies to IgCC Section maximum 1-inch-thick (25.4 mm) rigid foam plastic 505.2.5; CALGreen Section A5.405.1; ICC 700-2008 insulation laminated to the interior face with PVA adhesive. Section 608.1; ICC 700-2012 Sections 609.1, Refer to ESR-3373 for additional product description. 11.609.1 '& 12.1(A).609.1; LEED Homes MR 2.2(c); 4.0 CONDITIONS LEED v4 Homes MRc3; LEED NC MR 5; LEED Schools MR 5; LEED v4 BD+C MRc3; ANSI/GBI 01- 4.1 Code Compliance: 2010 Section 10.1.4.11. AdvanTech® (AT-Series) Sheathin� Span, AdvanTech® 5.3 ICC-ES EC108 [Evaluation applies to 19CC Section (AT-Series) Floor Span, ZIP System Roof Sheathing, ZIP 806.1; ICC 700-2008 Section 901.4(6); ICC 700-2012 System® Wall Sheathing and ZIP System® R-Sheathing Sections 901.4(6) & 11.901.4(6); LEED NC EQ 4.4; have been evaluated for compliance with the requirements LEED Schools EQ 4.4; LEED v4 BD+C EQc2]. of the International Codes as listed in Table 1 of this report. 6.4 ICC-ES EC109 [Evaluation applies to ICC 700-2008 4.2 Green Rating Systems, Standards and Code Section 606.2; ICC 700-2012 Sections 606.2(2), Eligibility: . 11.606.2(2) & 12.1(A).606.2; ANSI/GBI 01-2010 The information presented in Tables 2 through 11 of this Section 10.3.2.1]. report provides a matrix of areas of evaluation and 5.5 Documentation establishing and documenting all corresponding limitations and/or additional project-specific major sources of primary manufacturing energy requirements, and offer benefit to individuals who are [Evaluation applies to ICC 700-2008 Section 606.3; assessing eligibility for credits or points. ICC 700-2012 Sections 606.3&11.606.3]. The final interpretation of the specific requirements of the 5.6 ICC-ES ESR-1474 documenting that ZIP System Wall • respective green building rating system, standard and/or Sheathing is equivalent to a code-prescribed water- code rests with the developer of that specific rating system resistive barrier [Evaluation applies to CALGreen or standard or the Authority Having Jurisdiction, as Section 5.407.1; ICC 700-2008 Section 602.9; ICC applicable. 700-2012 Section 602.1.8]. Compliance with items noted as "Verified Attribute" is 6.7 Refer to ICC-ES ESR-1474 for evaluation of the ZIP subject to any conditions noted in the tables. Decisions on System Wall Sheathing as an air barrier assembly compliance with those items noted as "Eligible for Points" [Evaluation applies to IgCC Section 605.1.2.1.1; ICC in Tables 2 through 11 rests with the user of this report, 700-2008 Section 703.2.1; ]CC 700-2012 Sections and those items are subject to the conditions noted. The 701.4.3.2, 11.701.4.3.2 & 12.1.701.4.3.1; LEED user is advised of the project-specific provisions that may Homes EA 3; LEED v4 Homes EAc7]. be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this 6.0 IDENTIFICATION report. Rating systems or standards often provide supplemental information�as guidance.' AdvanTech (AT-Series) Sheathin% Span, AdvanTech® (AT-Series) Floor Span, ZIP System Roof Sheathing, ZIP 5.0 BASIS OF EVALUATION System® Wall Sheathing and ZIP System® R-Sheathing The information in this report, including the "Verified products are identified with a stamp noting the Attribute," is based upon the following supporting manufacturer's name(Huber Engineered Woods, LLC)and documentation: address, the product name the manufacturing location, the ICC-ES evaluation report number (if applicable), and the 5.1 ICC-ES EC102 [Evaluation applies to IgCC Section name or logo of the inspection or grading agency. The 505.2.4; CALGreen Sections A4.405.4 & A5.405.2; report subjects are also identified on the product and/or ICC 700-2008 Section 606.1(2); ICC 700-2012 packaging with the VAR Environmental Report number Sections 606.1, 11.606.1 & 12.1(A).606.1; ANSI/GBI (VAR-1012)and the ICC-ES SAVE Mark, as applicable. 01-2010 Section 10.1.2.2]. TABLE 1—REFERENCE STANDARD OR EVALUATION REPORT NUMBER FOR HUBER ENGINEERED WOODS LLC PRODUCTS PRODUCT REPORT NUMBER/ REFERENCE STANDARD AdvanTech®(AT-Series)Sheathing Span ESR-1785 AdvanTech®(AT-Series)Floor Span ZIP System®Roof Sheathing ESR-1473&ESR-2227 ZIP System®Wall Sheathing ESR-1474&ESR-2227 ZIP System®R-Sheathing ESR-3373 VAR-1012 I Most Widely Accepted and Trusted Page 3 of 6 TABLES 2 THROUGH 11 Section Posslbls AdvanTech Adv-Tech ZIP System ZIP System ZIP System Number Section Intent Points Conditions of Use to Quality Roof Wall Sheathing Floating Sheathing Sheathing RSheathlng TABLE 2—SUMMARY OF AREAS OF ELEGIBILITY WITH 2012INTERNATIONAL GREEN CONSTRUCTION CODE 505.2.4 Bio-based products WA All Huberwood products are qualified as bio-based. • • • • 05 Products shall be recovered,harvested,Rxtracted 8 manufactured within a 500 mile (800]on)radius of the building site.Where only a portian of a material or product is recovered,harvested,extracted 8 manufactured within 500 miles(800 Ion),only 505.2.5 Indigenous materials WA that portion shall be included.Where lasouiaea are transported by water or rail,the O O O 0 distance to the building site shall be determined by multiplying the distance that the resources are transported by water or rail by 0.25,&adding that number to the distance transported by means other than water or raiC 605,1.2.1.1 Air barrier installation WA Install the system in accordance with the manufacturer's installation instructlons an - • ICC-ES evaluation report ESR-1474. 806.1 Formaldehyde emissions WA Huberwood structural panels comply with US DOC PS 2(See Table 1 ofthis report • • • • Os and are exempt from formaldehyde emissions testing. TABLE 3—SUMMARY OF•AREAS OF ELEGIBILITY WITH 2O13 CALIFORNIA GREEN BUILDING STANDARDS CODE Verily laical products coal are extracted,processed and manufactured within A5.405.1 Regional materials O O O O California or 500 cotes B05 km of the eb s'tie° A5.405.2 Si.-based materials All Huber mod products are qualified as bio-based. • • • • 05 Elective A4.405.4(5)405- Renewable sources Materials from renewalhle sources(such as engineered wood). • • • • 05 A5.405.2.1 Certified Wood Under review by California Building Standards Comm'sion3 WA WA WA WA WA 5.407.1 Water-resistant exterior wall assembly I lHuber products provide a water-resistant exterior wall envelope. O O Mandatory 4.504.5 Composite wood product emissions EWP products do not apply to the compostie wood product definition 5.504.4.5 - =1=61 TABLE 4—SUMMARTOF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD(]CC 700-2008) Installawater-resistive border andlor drainage plan system hehind exterior veneer 6029 Water-resistive barrier Mandatory r and/or siding a '�. 3' • • Two types of biobased materials are used,each for To earn 6 points products must be at least 1%of the construction material cost AN 606.1(2) more than 1%of the projects projected building 6 another bio-based product at 1%of material cost must be used 1 or 3 points are • • • • Os material cast available for greater than 0.5%. Two certified wood-based products are used for To eam 3 points a second certified wood product must also be used as a minor 606.2(1) minarelements of the building,such as all wails, 3 element' • • • • Os (tools at roof Two certified rood-based products are used for To earn 4 606.2(2) major elements of the building,such as al walls, q element' Points a second certified wood product must also be used as a major • • • • Os Boors or root Materials are used for major components of the building that are manufactured using a minimum of 2 each To earn 6 points the products must be used for at least 3 major components of the s 606.3 33%of primary menufactudng process energy • • • • O derived from renewable sources,combustible waste 6max buNdjng.2 points may be earned when used for each major component sources,or renewable energy credits D =Eligible for points • =Verified attribute =This provision does not apply to this product Note:Footnotes are lasted after Table 11 VAR-1012 Most Widely Accepted and Trusted Page 4 of 6 TABLES 2 THROUGH 11 Continued ZIP System ZIP Systam Section Secton Intent Postlhlo Conditions of Use to OualHy AdvanTech AdvanTrch Roof Wall ZIP System Numher Points Sheathing Fiaoring Sheathing Sheathing RSheathing S TABLE 4—SUMMARY OF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD(]CC 700-2008)(Continued) 608.1 Indigenous materials 2 each oc earn 2 points verily local products are mg mated.produced,grow naturally or O O O O 10 max occur naturall w8hin 500 miles 805 km of ab s8e° Insulation and air sealing Is Installed In accordance with all the fallowing,as 3 applicable: r75 703.2.1 Insulation and air sealing l O O 15 mu (1)third-party verification performed 15 pts, - (2)no third-parry verification performed 3 pts Structural plywood used for floor,wall,andfor roof sheathing complies with DOC PS 1 and/or DOC PS 2 OSB used for floor,wall,and/or real sheathing To meet this a minimum of 85%of OSB or plywood In the building must consist of 901.4(1) complies with DOC PS 2 Panels are made win Mandatory Huber products. • • • • • moisture-resistant adhesives and the trademark indicates the adhesives are Exposure 1 or Exterior (plywo d)and Exposure 1(OSB) 901.4(6) Non-emit8ng products,which can include structural 1 4 A minimum of 8.5%of product In the building are the identified Huber products. • • • • •5 wmd framing TABLE 5—SUMMARY OF AREAS OF ELEGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD(ICC 700-2012) Install a water-resistive barrier andlor drainage plan system behind exterior veneer 6021.8 Water-resistive harrier Mandatory and/or sldin. • • 606.1(2) Two types of blobased materials are used,each for To earn 6 points products must be at least 1%of the construction material cost AN 11,606.1(b) more than 1%of the projects projected building 6 another biobased product at 1%of material cost must be used.1 or 3 points are • • • • W 12.1(A.606.1 material cost available for realer than 0.5%. 606.20) Two certified wood-based products are used for To earn 3 points a second certified wood product must also be used as a minor e 11.606.2(1) minor elements of the building.such mall him, 3 element' • • • • O 12.1 A.606.1 pone ,or mi9vmrk 606.2(2) Two certified wood-based products are used for To earn 4 points a second certified Wined product must also be used as a major s 11.606.2(2) majorelements of the balding,such as all walls, 4 element' • • • • O 12.1 A.606.2 floors or roof Materials are used for major components of the building are manufactured using a minimum of 33 606.3 2 each To earn 6 points the products must he used for at least 3 major components of the y 11.606.3 of primary manufacturing process energy derived 6 max building.2 points may be earned when used for each major component • • • • O from renewable sources,combustible waste sources,or renewable energy credits To earn 2 points venfy material is produced,grows naturally,or occurs naturelly within 500 rules(805 km)of the job site if transported by truck or 1500 miles(2414 •,""�'yt- 2 each k are assembled om)it transport for produced h for at leastem multiple raw mate 80%of the total distance by rail or water.Products the 609.1 Regional materials 10 m materials qualify If me vregMed O O 0 O a1 ^ ax average(by might or volume)of the distance the raw,materials have been Itransported meet the distance criteria. .s' Insulation and air sealing is installed to—ordance with a8 the followng,as - -5;i 701.4.3.2 3 icable: f 11.701.4.3.2 Insulation and air sealing 15 max (1)tlhird-party verification performed 15 pts, O O 12.1.701.4.3.1 (2)no third-party verification performed 3 cats Structural plywood used for floor,wall,andfor roof sheathing complies with DOC PS 1 and/or DOC PS 901.4(1) 2.OSB g To meet this a minimum at 65%of OSS or plywood in the build used for floor,wall,andfor roof sheathing must consist of 11.901.411) complies with DOC PS 2.Panels are made with Mandatory Huber products. • • • • • 12.1.901.4(1) moisture-resistant adhesives 8 the trademark indicates the adhesives are Exposure 1 or Exterior (plywood)8 Exposure 1(OSB) 901AM Nan-emoting products,which can include structural 4 A minimum of 85%of product In the building are the Identified Huber products. • • • • Os 11.901.4 6 wood framing O =Eligible for points ' • =Verified attribute '=This provision does not apply to this product Note:Footnotes are located alter Table 11 VAR-1012 Most Widely Accepted and Trusted Page 5 of 6 TABLES 2 THROUGH 11 Continued Section Section Intent Possthis Conditions of Use to Quality for Points AdvanTech Adv-Tech ZIP system ZIP System ZIP System Number Points fY Sheathing Flooring Roof W-11 Sheathing Sheathing RSheathing TABLE S—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED FOR HOMES 2008 FJ13 Air Infiltration 3 max To earn 2 or 3 points meet tne all leakage requirements shown »r , In Table 17 of the credit,as applicable. ? ' }° d O O MR 21 FSC certified tropical mod 0.5 each 2 2� 2 " 2 2 W •8 max To earn 0.5 point per component use FSC-certified tropical woo0� To earn points use products that are extracted,processed and manufactured within floom;n tenor ly preferable products for tong wall8 0.5 each MR 22(c) 500 miles(805 km)of the site for a minimum o190%(by might or volume of the floors;interior 8 exterior framing 8 sheatnirg B max e g O O O O cent nent. TABLE 7—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED V4 HOMES EAc7 Air Infiltration 2 max To earn 1 or 2 points based on air leakage rates determined by testing and verification. -,d '�s.: O O MR FSC certified tropical wood Prerequesile All wood must be nontropical or certified by FSC of USGBC-approved equivalent' 2 2 2� 2 2 puon 1:To earn points use framing t at Is extrect pit a manu acturec F"mile?mentally preferable products for roof,wail 8 0.5 each in 100 miles(160 km)of the site for a minimum of 50%(by weight or volume)of O O O O MRc3 Doom;interior&ederiorframing 8 shealhirg 8 max Option 2:Use woad products certified by FSC of USGBC-approved equivalentt2 2 2 2 2 02< EOc2 Law emitting materials 1 To earn 1 point use wood composite products mntaning no-added urea- farm aldeh de resins. • • • • 05 TABLE 8—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED 2009 FOR NEW CONSTRUCTION AND MAJOR RENOVATION MR 5.1 Regional materials(10%of content) 1 To earn 1 point use products that are extracted,processed and manufactured MhI O O O O 500 miles 805 km of the site for a minimum of 10%(by cost)of total materials MR 5.2 Regional materials(20%of content) 2 value.To earn 2 points use a minimum of 20%6 O O O O MR 7 Certified rood 1 To earn 1 paint use a minimum 50% (based on cost) of wood-based 2 2 2 2 -.,2 ' materials/ oducts certified to FSC re ulrements2 EO 4.4 Low emitting materials 1 To earn 1 point use wood composite wood products containing no-added urea- formaldehyde resins. • • • • 05 TABLE 9—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED 2009 FOR SCHOOLS NEW CONSTRUCTION AND MAJOR RENOVATION MR 5.1 Regional materials(10%of cement) 1 To earn 1 point use products that are extracted,processed and manufactured withi O O O O 500 miles(805 km)of the site for a minimum of 101%(by cell)of total materials '•`�"� MR 5.2 Regional materials(20%of content) 2 value.To earn 2 points use a minimum of 20%.8 O O O O ' °�.�' MR7 Certified wood 1 To earn 1 point use a minimum 50% (based on cost) of wood-based 2 2 2 2 ..,2_..?. a rials/roducts certified o FSC requirements" EO 4.4 Low emitting materials 1 To earn 1 point use wood composite wood products containing no-added urea- formaldehyde resins. • • • • 05 TABLE 10—SUMMARY OF AREAS OF ELEGIBILITY WITH USGBC'S LEED V4 BUILDING DESIGN AND CONSTRUCTION(BD+C) MRc3 Sourcing ofrawmatedals-certficatlonof newwood 1 Option 2:Use wood-based materials/products certified by FSC or USGBGapprwed 2 2 2 2 products uwlent' 02 Products meeting the r location ra ion, Option 2 may be eligible for additional MRc3 Sourcing of raw materials-source location WA credit based on source location(extraction,manufacture and purchase point)based s s a s on location relative to project srtP. IEOcZ2 Low emitting materials WA EWP and lumber products do not apply to the composite wood product definitiall O =Eligible for points • =Verified attribute =This provision does not apply to this product Note:Footnotes are located after Table I 1 . VARAG12 I Most widely Accepted and Trusted Page 6 of 6 TABLES 2 THROUGH 11 Continued Section Possible AdvanToch AdvanTech ZIP System ZIP System ZIP System Number Section Intent Points Conditions of Use to Qualify for Points Sheathing Ftnortng Roof Wall Rsheathing - Sheathing Sheathing i TABLE 11—SUMMARY OF AREAS OF ELEGIBILITY WITH ANSIIGBI 01-2010—GREEN BUILDING ASSESSMENT PROTOCOL FOR COMMERCIAL BUILDINGS 10.1.22 Blobased Products-building assemblies 7 max All Huber wood products are qualified as biobased • • • • 05 To earn credits use products that are extracted,processed and manufactured within 10.1.4.1 Regional Materials-building assemblies 5 max 500 miles(805 km)of the site for a minimum of 90%(by weight or volume of the O O O O component° 10.3.21 Certified wood 6 max Between 10%and 60%or more of wood-based products used in the building are • • • • OS third pa certified. O =EI"gible for points ' • =Verified attribute =This provision does not apply to this product Footnotes: 'Certification is required of the manufacturer only.Vendor Chain of Custody is not required to qualify for this point Forest certification credit for LEED'20D9 resources FSC exclusively and for LEEO v4 resources either FSC or USGBGapprwed equivalent.Contact USGBC for a list of approved equivalent programs. aCGBSC recognizes Importance of use of certified forest products however the specific requirements are currently under development This area is not be confused with the provisions of EO 4.4 In LEED(Table 4)because the California Air Resources Board(GARB)does not regulate engineered wood product emissions. 'Eligibility applies only to the wood-based sheathing potion of the panel. 'Regional material calculations based on project lomtlon provided by Huber upon request. ' WA=Not applicable ICC r EVALUATION Most WidelyAccepted and Trusted c c ERVICE reportICC-ES Report ESR-1473 Je I_,r DIVISION: 06 00 00=WOOD, PLASTICS AND COMPOSITES SECTION: 06 16 00—SHEATHING DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 30 05—ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE•300 CHARLOTTE, NORTH CAROLINA 28262 EVALUATION SUBJECT: ZIP SYSTEM® AND ZIP SYSTEM+TM ROOF SHEATHING i ICC ICC ICC c r �. C • PMG LISTED Look for the trusted marks of Conformity! MCI ay"2014 Recipient of Prestigious Western States Seismic Polic Council (WSSPQ Award in Excellence" A Subsidiary of 2HoroRMT1601 ECOUNCIr ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not �C specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a G!D recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as ' to any finding or other matter in this report, or as to any product covered by the report. P WG AeerteM1b LGN „ Copyright© 2015 [CC Evaluation Service, LLC.All rights reserved. NEICC EVALUATION ...$ SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report , ESR-1473* Reissued September 2015 This report is subject to renewal.September 2.017. www.icc-es.orcl J (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:06 00.00—WOOD, PLASTICS,AND , required in Chapter 15 of the IBC and Chapter 9 of the COMPOSITES 1RC.The OSB substrate complies with U.S. DOC PS-2 for Section:0616 OO—Sheathing wood structural panels and is overlaid on one-side with a medium-density, phenol-impregnated, polymer-modified DIVISION:0100 00—THERMAL AND MOISTURE sheet material. The standard-size panels are nominally PROTECTION 4 feet by 8 feet. Oversize panels, wider than 4 feet Section: 07 30 05—Roofing Felt and Underlayment "(1219 mm) or longer than 8'feet(2438 mm), or both, are also produced. The panels are available with either a REPORT HOLDER: square-finished-edge profile a tongue-and-groove edge profile or a machined edge profile. The proprietary seam HUBER ENGINEERED WOODS, LLC tape is a'self-adhering sheet-type membrane consisting of ONE RESOURCE SQUARE acrylic adhesive laminated to a polyolefin backing, and the 10925 DAVID TAYLOR DRIVE,SUITE 300 face of the tape is labeled with ESR-1473. The. tape is CHARLOTTE,NORTH CAROLINA 28262 0.012 inch thick (0.30 mm) with a minimum width of (800)933-9220 3 inches(76.2 mm), and comes in rolls of varying length. www.huberwood.com 4.0 INSTALLATION EVALUATION SUBJECT: ' 4.1 General: ZIP SYSTEM®AND ZIP.SYSTEM+Tm ROOF SHEATHING Installation of ZIP Systems and ZIP System+TM roof sheathing must comply with the applicable code,this report 1.0 EVALUATION SCOPE' and the manufacturer's published installation instructions. The installation 1ristructions are to be available at the Compliance with the following codes: jobsite at all times during installation.-The instructions- ■ 2015,2012 and 2009 International Building Code®(IBC) within this report must govern if there are any conflicts between the manufacturer's published instructions and this ■ 2015, 2012 and 2009 International Residential Codes report. (IRC) 4.2 Application: ■'2013 Abu Dhabi International Building Code(ADIBC)t The ZIP Systems andt ZIP System+T11 roof,sheathing tThe ADIBC is based bn the 2009 IBC.2009 IBC code sections referenced panels must- be installed with the longer dimension, in this report are the same sections in the ADIBC. perpendicular to the roof framing and fastered-to the Prope.rties,.evaluated: roof framing in 'accordance with the applicable code for ■ Structural—wind u lift resistance wood structural panels. The panels must be installed in p accordance with the panel span rating as shown on the ■ Nonclassified roof covering panels. All corners are to be securely fastened. Tongue- ■ Classified roof•covering and-groove" and machined edge,panels are designed to provide the correct gap size at the panel edges during ■ Weather resistance ' installation. Squared-edged panels must be spaced apart a 2.0 USES minimum of 1/9 inch (3.18,mm) at the time of installation.. End joints of adjacent panel runs must be staggered. The ZIP System® and ZIP System roof sheathing panels panel' must be installed with the laminated phenol- are used as combination •roof sheathing and roof impregnated polymer-modified sheet material facing to -underlayment. the exterior. All ZIP System® and ZIP System+Tm roof sheathing_seams must be sealed with the Zip Systems 3.0 DESCRIPTION tape. All overlay surfaces must be free of any significant The ZIP Systems and ZIP -System+Tm roofSheathing presence of debris particles or sawdust prior to installation panels are- wood structural panels having a laminated of the ZIP System tape.-Overlay surfaces must be void of facer. The ZIP System+TM panels are manufactured using any free water prior to application of the ZIP Systems tape., a different resin than the Zip Systems panels. .The panels The ZIP Systems tape edges must be sealed and the tape are installed with a'proprietary seam tape,which allows the is to be centered within +/- 1/2 inch 1112.7 mm) of all panel systems to be used as an alternate to the underlayment edge seam centers. All ZIP System and ZIP System+TM •Revised November 2015 /CC-ES Evaluation Reports are not to be construed as representing aesthetics or any'other attributes nor specifically addressed,nor are they to be construed - as an endorsement of the subject ofthe report or'a recommendation for its use.There is no.warranty by ICC Evaluation Service,LLC,express or implied,as .011 to any finding or other matter in this report,or as to any product covered by the report. M pa Copyright(D 2015[CC Evaluation Service,LLC. All rights reserved. Page 1 of 2 ESR-1473 I Most VVIdelyAccepted and Trusted Page 2 of 2 roof sheathing surface defects, openings, cracks, etc., that wood structural panels with either a 24/16, 32/16 or completely penetrate the overlay and substrate, and 40120 span rating. caused by handling or construction work, must be covered ® ® 5.4 In jurisdictions enforcing the IBC, the roof covering with the ZIP System tape. The ZIP System tape must system incorporating the panels is limited to extend a minimum of 1 inch (25.4 mm)past the panel edge installations in the following construction types: T-joint intersections. The ZIP System tape must be adhered to the ZIP System® and ZIP System+TM roof . Type III-B and Type V-B sheathing. Wrinkles in the ZIP System seam tape are acceptable unless they create a leak path to the panel • Type III-A or Type V-A under the conditions seam. specified in footnote d of IBC Table 601 4.3 Roof Assemblies • Type III-A or Type V-A under the conditions 4.3.1 Classified Roof Coverings specified in footnote b of IBC Table 601, for g occupancies other than Group F-1, H. M and S-1 4.3.1.1 Class A: Underlayment is not required for a In jurisdictions enforcing the IRC, the roof covering minimum 1/2-inch thick Zip System+TM roof sheathing with system incorporating the panels may be installed on Class A asphalt glass fiber mat shingles. structures constructed in accordance with the IRC. 4.3.1.2 Class B: Underlayment is not required for a 6.5 Enclosed attics and rafter spaces must be ventilated minimum 7/1 6-inch thick Zip System roof sheathing with in accordance with the applicable code, except where Class A asphalt glass fiber mat shingles. unvented conditioned attic assemblies are permitted 4.3.2 Nonclassified Roof Coverings: The ZIP System® by 2015 and 2012 IRC Section R806.5 or 2009 IRC and ZIP System+TM roof sheathing panels are limited to Section R806.4. installation on buildings permitted to have nonclassified 6.6 An ice barrier must be provided as required .by roof coverings using code-complying asphalt-fiberglass Section 1507.2.8.2 of the IBC and Section R905.2.7 shingles,metal shingles,metal panels,wood shakes,wood of the 2015 IRC and Section R905.2.7.1 of the 2012 shingles, built-up roofing, slate and slate-type shingles, and 2009 IRC. and clay and concrete tile roof coverings. Roof coverings may be applied directly to the taped ZIP System®and ZIP 6.7 Installation is limited to roofs having a slope of 2:12 System+TM roof panels unless multi-layer undedayments (16.67%slope)or greater. are required. 5.8 ZIP System® and. ZIP System+"m roof sheathing 4.4 Wind Uplift Resistance: panels are manufactured by Huber Engineered Wind uplift design loads and ZIP System ® and ZIP Woods, LLC, in Crystal Hill; Virginia; Commerce, Georgia; Broken Bow, Oklahoma; and Easton, Maine, System+TM roof wood structural panel allowable uplift under a quality-control program with inspections by resistance shall be determined in accordance with ICC-ES. Sections 1609 and 2304.8.2 of the 2015 IBC or 2304.7.2 of the 2012 and 2009 IBC and Section R301.2.1 of the IRC. 6.0 EVIDENCE SUBMITTED Roof coverings must be fastened to the sheathing with mechanical fasteners sufficient to resist the design uplift Data in accordance with the ICC-ES Acceptance Criteria load. for Wood Structural Panel Roof Sheathing Factory- laminated with an Alternative Roof Underlayment(AC266), 5.0 CONDITIONS OF USE dated May 2008(editorially updated October 2015). The ZIP System® and ZIP System+Tee roof sheathing 7.0 IDENTIFICATION panels described in this report comply with, or are suitable Each ZIP System and ZIP S stem+TM roof sheathing alternatives to what is specified in, those codes listed in y y g Section 1.0 of this report, subject to the following panel covered by this report must bear a label that includes conditions: the manufacturer's name(Huber Engineered Woods, LLC) and address; the product name; the evaluation report 5.1 This evaluation report and the manufacturer's number(ESR-1473); and the grade, performance category published installation instructions, when required by and bond classification. the code official, must be submitted at the time of permit application. The panel mill label and span rating, grade, performance category and bond classification label must be visible on 5.2 The ZIP System® and ZIP System+rm roof sheathing the bottom face of panels, opposite the laminated facer panels must be manufactured, identified and installed in accordance with this report and the manufacturer's The ZIP System® tape roll is labeled with the product published installation instructions. name and the evaluation report number(ESR-1473). 6.3 The ZIP System®and ZIP System+Tm roof sheathing ' panels are limited to code-approved structural use for tl tICC EVALUATION t�� SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1473 FBC Supplement Reissued September 2015 This report is subject to renewal September 2017. www.icc-es.org 1 (800)423-6587 1 (662) 699-0543 A Subsidiary of the International Code Council® DIVISION: 06 00 00—WOOD,PLASTICS,AND COMPOSITES Section: 06 16 00—Sheathing DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 30 05—Roofing Felt and Underlayment REPORT HOLDER: HUBER ENGINEERED WOODS,LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE,SUITE 300 CHARLOTTE,NORTH CAROLINA 28262 (800)933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM®AND ZIP SYSTEM+TM ROOF SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP System® and Zip System+Tee roof sheathing, recognized in ICC-ES master evaluation report ESR-1473, has also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2014 Florida Building Code—Building ■ 2014 Florida Building Code—Residential 2.0 CONCLUSIONS The ZIP System®and ZIP System+Ten roof sheathing, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1473, complies with the 2014 Florida Building Code—Building and the 2014 Florida Building Code—Residential, provided the design and installation are in accordance with the International Building Code®provisions noted in the master report, and with the condition that wind uplifting design loads must.be determined in accordance with Section 1609 of the Florida Building Code—Building and Section R301.2.1 of the Florida Building Code—Residential. Use of the ZIP System® and ZIP System+TM roof sheathing for compliance with the High-Velocity Hurricane Zone provisions of the 2014 Florida Building Code—Building and the 2014 Florida Building Code—Residential has not been evaluated and is outside the scope of the evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued September 2015 and revised November 2015. /CC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by]CC Evaluation Service,LLC,express or implied,as 1-IM11— to any finding or other matter in this report,or as to any product covered by the report. , Qo „oo Copyright©2015[CC Evaluation Service,LLC. All rights reserved. Page 1 of 1 Florida Building Code Online Page 1 of 1 C .� . ' - + A Ion sm BCIS Home i Log In I User Registration i 'Hot Topics I Submit Surcharge'I Stats&Facts ' Publications I FBC Stall I BCIS Site.Map I Links i Search I Fl lida Product Approval • � Q USER:Public User - st�,'xvroKs�it`m - proddct Approval Menu>Product or Application Search>Application List s Search Criteria Refine Search Code Version 2014 FL# 17147 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL- Compliance.Method ALL ' Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for-use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Applications FL# T" filamufactmeT Validated By status FL17147- Revision Huber Engineered Woods LLC ICC Evaluation Service, Approved Category:Structural Components LLC. History Subcategory:Products Introduced as a.Result of New (205)599-9800 Technology -Approved by DBPR:Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Roads Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to section 455.275(i),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with in email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click he[. " • Product Approval Accepts: uIllms® — Credit Card Safe https://www.floridabuilding:org/pr/pr_app_lst.aspx 4/12/2017