FL# FL17147-RI
Application Type Revision
Code Version. 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Huber Engineered Woods LLC
Address/Phone/Email 10925 David Taylor Drive
Suite 300
Charlotte,NC 28262
(704)548-5442
kurt.koch@huber.com
Authorized Signature Kurt Koch
kurt.koch@huber.com
Technical Representative Ken W.Nix
Address/Phone/Email 1446 Hwy 334
Commerce,GA 30530
(706)336-3041
ken.hix@huber.com
Quality Assurance Representative Walker Campbell
Address/Phone/Email 1446 Hwy 334
Commerce,GA 30530
(704)562-1053
walker.campbell@huber.com
Category Structural Components "
Subcategory Products Introduced as a Result of New Technology
Compliance Method Evaluation Report from a Product Evaluation Entity-
Evaluation Entity ICC Evaluation Service,LLC
Quality Assurance Entity ICC Evaluation Service
Quality Assurance Contract Expiration Date 10/01/2017
Validated By ICC Evaluation Service,LLC.
Certificate of Independence FL17147 R1 COI Certificate of Independence for Eval ation odf
Referenced Standard and Year(of Standard) Standard Year
ICC-Evaluation Service AC310 2015
Equivalence of Product Standards
Certified By
Approved Evaluation-Entity.
FL17147 RI Eouiv AC310.pdf
Sections from the Code {'r
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option C
Date Submitted 08/31/2015
Date Validated 09/16/2015
Date Pending FBC Approval
Date Approved 09/20/2015
Summary of Products
FL# Model,Number or Name Description
17147.1 ZIP System(R)Wall Sheathing ZIP System(R)Wall Sheathing
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17147 R1 1I ZIP Sheathina Install Manual-2013 Ddf
Approved for use outside HVHZ:Yes Verified By: ICC Evaluation Service, LLC
Impact Resistant:No Created by Independent Third Party:
Design Pressure:N/A Evaluation Reports
,. Other:.limited to structural aspects of panel FL17147 R1 AE ESR-1474(2)Ddf
FL17147 R1 AE ESR1474.12df
Boat Next ,
'Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:BSO-4B7-1B24
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida..::Privacy Statement::.Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(l),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
_ Chapter 455,F.S.,please click ha.n.
Product Approval Accepts:
Credit Card
Safe
'
y,
w�
.�� r� _
yt
�`,.5 4e ..-
r„' �£' �,+ �6�" S-'��o d .�'d�c.a>hr�'��� ���1� _ ��
..ad." ,t a :t d#'+ .� 'i' � n r '1 `'g, ,n:� >" ^�W-t ,u"`s = ,r `
fy if l .�/� t 't r ,a�� ,e � r3 ,?
p � �6� �� T Sx,. a ^';. •y 1 ,��. E �, %'T " ....6R
?.``'` d7 ; u,.� „--�d - ,� �+'F'
:.
{ -, g � �` ^�" �. rY' 'q._- LE ¢ F5- k � 59 ;��i Y € 1 f b. �+`i F.
a �,
s..
5•`,„ � �� � ,�, jn s IN
x
'7"" �.' - 4
a. ,;xvscs, on ^`r- :r` '^ ,r..1"r ... ,,;,.,xxt 7.^,,$, h '"'...tti,.`.r ..x ,,:� a�*"xtx ..f.:,. -.
,X"y :vsy 7 .Y -. s r ,#r ..€`Y x ,-.... ,�-5,. ._yx x'dC _kn., za.SC T` _..u.rd'
- c..^t �Y9£ h �r{ `- � 5.�.,. 't rr,v a#,f' a�^' kr ,r{;? k. f •�s v^`Y `r f ,i ,t£s .+zr .a. ' r,"`„-'`a [
ip?.,3`Y'�'�i c_.: q g t 1'.:fir, R'2 ri ' 's r i . "n ' v-5t � �-.a� .+�i. iY, =}'4
y R � x .3 $•��� �_�f d�r..0 � 5f+��� .s .. C fat .�,_ c ,t�P ,,,, �� �'��€� �rF' �� ��s� �;v� i4`°'�>'�rx�'y*rz'.�`��' w'�ass. #f a�i
,7•.'1+:,= x .�/b`" ) Jam ` 3�` .'.3.
{'�`�sn�,�. "
.
t'` '' �;�, "��`,y»,+-*:- '.��. �S' `�`.�' „''?;,:5 ,,��"�a.Y�;�,, �. .�y r,•r�,.�ru f`� �,�. ,,� �&4 � .7' ,�'':s:
;,.,p,a,;.,t. �,? '�`srtT"r.�r.�€ �M_.v ,;,,}a..F-.�.'� �-s,_ .�"�.��3's�^£,.:�F b��.,�.s- nr-:.;,.`-, ,�'�'-a� �A Y?. ����' �"r�= $ +ts,�.�`.. � :•,��-`fit ,.G't*s� ,;`�K.r^�-�s€i}�, ,�g �;:
hr`I°+s�i�' '-. �,�, .z�l�, atn„:" ,.`s.. *.s �.` y ra• _z,...z ,. > *aa, `!�` ,,,,.,. Y=c s` .� -rx" „E."+y �., c � y+t
�` -- �Y`�',vi i?z.�.M:s-.,Y.dr�'C'I' �F�`X^ �'n''� �„ �"'^-;.. ./':t ..�-P SF�i "+-i�' S`.' .� sz *'�� � .✓� .t"F.�s�3� � t w�"'. ; w�"
Wh
', 3�Dlf uUltB 900�`FIiOne � 0 993. 2`�:y,,.'I ZljlSy6rtE COI11"'3`q" 8;1d �.�A'�{g ''s s" 'r'�•s=y'"` 'x
�v 6 erx "'at varllec Whams
,n. 19170f�D IV 62 5 = Fair17p4 g xek �rz s w.' Fl�a' Wo3dst�LCt r� sYheNed ffiWalsare W .,
s F':r zE d'.9° R >•t. ;,' 7k9228 4,}, "'r".a: i'r :,'+ .r.}
,a
��.Tqc �t�F�76� s �ioog.�(.C` �tl8rssee yj.l�d'iva..eb-a.-�,r ��;�+
'° 4€, r=1 �atr ,; tsi" 1`Hi?1f0 ;e�
�a..._w:,.�:��-.
' �IIQ~FY ENGINEERED
ZIP System®Roof & Wall Sheathing ZIIA7Systeni M
INSTALLATION MANUAL ROOF&WALL SHEATHING
FASTER.TIGHTER.ENERGY EFFICIENT.
Contents
02 ZIP System® Sheathing Installation On Roofs 08 ZIP System®Roof&Wall Sheathing -Window
Installation Flanged Windows&Brick Mould Windows
03 ZIP System'" Tape Installation -
Roof Panel Seams 09 ZIP System® Roof & Wall Sheathing - Window
04 ZIP System'" Tape Installation -
Installation Brick Mould Windows (continued)
Roof Panel Seams (continued) 10 ZIP System®Roof & Wall Sheathing -
Penetration Openings
05 Roof Covering Installation Instructions
11 ZIP System® Roof &Wall Sheathing
06 ZIP System® Roof & Wall Sheathing Installation Installation Details
07 ZIP System'" Tape Installation - Panel Seams 12 ZIP System® Roof & Wall Sheathing
Installation Details (continued)
ATTENTION: This installation guide is intended to provide general ZIP System Roof &Wall sheathing can be used with a range of exterior
information for the designer and end user.The following guidelines claddings and roof coverings. Approved wall coverings include brick,
will help you safely and properly install the ZIP System®Roof&Wall vinyl, stone, wood fiber cement, wood and cedar shakes, traditional hard
wall sheathing.We urge you,and anyone installing this product,to coat stucco and specified drainable EIFS applications, however it is
read these guidelines in order to minimize any risk of safety hazards not recommended for use with adhesively attached E1FS. Approved roof
and to prevent voiding any applicable warranties. This manual is coverings include asphalt-fiberglass shingles,metal tiles and panels,clay and
a general installation guide and does not cover every installation concrete tiles, slate and slate-type shingles and wood shakes and shingles.
condition. Proper installation shall be deemed to mean the most Follow all cladding and roof covering manufacturer's installation instructions.
restrictive requirement specified by Huber Engineered Woods (HEW),
local building code, engineer or architect of record or other authority ZIP System Roof & Wall sheathing can be used on buildings of Type
having jurisdiction. You are fully and solely responsible for all safety III (Roof Applications ONLY) and Type V construction and construction
requirements and code compliance.For additional information contact permitted under the IRC.
Huber Engineered Woods LLC. ZIP System®Roof&Wall Sheathing Includes:
ZIP System®Roof&Wall Sheathing Safety Guidelines - ZIP System sheathing panels with built-in moisture barrier with preprinted
- Follow all OSHA regulations and any other safety guidelines and safety fastening and tape guides
practices during installation and construction. - ZIP System tape
- Use approved safety belts and/or hamesses or other fall protection equipment.
- Install ZIP System panels and tape only in dry conditions and on dry surfaces. Storage and Handling
Do not install in rain,snow,frost or other slippery conditions. - Set panel stack on three supports(stickers)to keep off the ground.
- Wear rubber-soled or other high-traction footwear while installing ZIP System " Outdoors, cover panels loosely with waterproof protective material.
sheathing in a roof application.Do not wear footwear with wom soles or heels. Anchor covers on top of the stack, but keep away from sides and bottom
- Ensure the roofing surface is free from oil, chemicals, sawdust, dirt, tools, to assure good air circulation.
electric cords, air hoses, clothing and anything else that might create a In high moisture environments,cut banding on the panel stack to prevent
tripping hazard.
edge damage.
- Install temporary toe boards along the ZIP System sheathing roof surface. ZIP System®Roof&Watt Sheathing Notes and Limitations:
- Do not use on roofs with slopes less than 2112.
What Is ZIP System®Roof&Wall Sheathing? - Do not use abutted against general stone or masonry without providing a
ZIP System Roof&Wall sheathing is code-recognized as a wood structural minimum of a 1/2"gap.
panel, roofing underlayment ([CC-ES ESR-1473), water-resistive barrier - Do not install ZIP System tape in temperatures less than 201 F
and air barrier(ICC-ES ESR-1474). ZIP System Roof & Wall sheathing - ZIP System products are not recommended for manufactured housing
has a built-in moisture barrier that lets you say good-bye to building paper applications that are built under a federal building code administered by
or housewrap on the walls and felt paper on the roof.' Simply install the the U.S.Department of Housing and Urban Development(HUD).
panels,tape the seams, and you have a structural wall sheathing, water- - Do not use panel edge clips(H-Clips)with ZIP System Roof&Wall sheathing
resistive barrier and air barrier or a structural roof sheathing and roofing without expressed written approval from Huber Engineered Woods."
underlayment all from one product. - Do not use ZIP System tape to permanently seal around circular roof
projections(plumbing vents,pipes, curved walls, etc.)
r
Contents (continued)
Wall Coverings Wet Blown Cellulose Insulation
ZIP System Roof &Wall sheathing should be covered with the finished - In addition to following manufacturer installation instructions,we recommend
roof covering or exterior cladding within 180 days of installation. a maximum moisture content of the cellulose of less than 25%measured at
Finished roof and exterior cladding products should be installed per the inside surface of the ZIP System panel before closing the wall cavity.
the manufacturer's installation instructions.
Per the recommendation of the Western Red Cedar Lumber Association Secondary Coatings
and the U.S.Forest Products Laboratory,wood siding should be primed Do not apply secondary coatings or treatments to ZIP System Roof &Wall
before installation. sheathing panels with the exception of the following:
When original roofing or claddings are removed and replaced on existing ZIP - HEW approved fire resistant coatings. Fire resistant coatings must be
System sheathing, the roof or wall should be covered with an additional tested and approved by HEW for use with ZIP System panels.
roofing undedayment or water resistive barrier prior to installation of the Feld applied water-soluble borate insecticide or fungicide treatments
new finished roofing or cladding. applied to the non overlay side of the panel. See technical tip, "Termite
Treatments on ZIP System Roof&Wall Sheathing,"on zipsystem.com for
Note:In cladding systems requiring multiple layers of water-resistive barriers, more information.
like traditional hard-coat stucco,ZIP_System sheathing is intended only to _ Permeable laminated radiant barrier foil or paint.For a radiant barrier foil or
replace the first layer. coating to be considered permeable,it must have an applied permeance of
five perms or greater as tested by the ASTM E 96 wet cup standard.For a
radiant foil,the permeance evaluation would include any adhesive and/or
backer used to laminate a foil. For a radiant paint/coating,the permeance
evaluation should be conducted at the applied thickness of the paint/coating.
ZIP System Roof and Wall sheathing replaces only the first layer in multi-undedayment systems.
Edge support is not required by code with 112(32116 span rated)and 518(40120 span rated)performance category.sheathing if the framing does not exceed 24'o.c.
and the total load does not exceed 93 pst for 112 and 156 psf for 518 performance categories.This is based on U180 deflection criteria for total load.
ZIP.System®Roof&Wall Sheathing Installation Manual
02
ZIP System®Sheathing Installation on Roofs
Overview:ZIP System.Roof&Wall sheathing is composed of ZIP System panels and ZIP System seam sealing tape.ZIP Systemm Roof&Wall Sheathing
panels should be fully installed before the seam sealing tape is applied.In general,the ZIP System roof sheathing panels should be installed from the lowest point
on the roof to the highest.It is at the discretion of the installer whether to apply tape from the top down or from the bottom up. However,working from the highest
sections of the roof and working down will minimize foot traffic on the tape.The following installation steps are presented as guidelines and a general outline of
the installation process.These are manufacturer installation recommendations—please visit zipsystem.com for a library of flashing and installation details.You are
fully and solely responsible for all safety requirements.Good construction and safety practices should be followed at all times.
Step 1.
Ensure that the panel surface is dry and clean of any nails,sawdust,or
other debris or protrusions prior to installing or walking on the panels.
After ensuring compliance with all OSHA and local code. safety
guidelines, install ZIP System sheathing panels with the moisture
barrier surface facing outside.The long edge(8') should be oriented
perpendicular to the framing members,and panels should be installed
with the 4'edge seams staggered a minimum of 24".
1/8"spacing between square edges of all adjacent panels is recommended,
in accordance with industry standards for wood sheathing. (Tongue& 8'panel Ed
Groove panels are designed to self-space and do not require manual g� 4'Panel Edges
1/8' 1/8°
spacing on the 8'edges.) f
The unique edge profile is Maintain 1/8"space
designed to accommodate where 4'edges meet.
incremental panel Unique edge'profile is on
expansion and does not 8'edges only.
require manual gapping
along the 8'edges.
Step 2.
- Ensure that ZIP System panels span at least three framing members and
a framing member supports the entire 4'edge of the panels.
- Fasten the ZIP System Roof& Wall sheathing panel to the framing
members with code approved fasteners spaced at the appropriate
edge and intermediate spacing. It is the responsibility of the general
contractor to verify proper fastener type and spacing prior to installation.
- Apply the fasteners 3/8"from the panel ends and comers.
- An ideal installation would be where fastener heads are flush with the
panel surface. However,due to'variations in materials and limitations
on equipment, this may be difficult to achieve in some situations. It
is not required to tape over overdriven fasteners unless the fastener
head creates a hole through the entire panel thickness. Please see
the technical tip,"Overdriven Fasteners in ZIP System Roof and Wall
Sheathing,"for more information.
Step 3.
Install temporary toe boards as necessary when applying the ZIP System
sheathing panels up the slope of the roof planes.
03 .•
ZIP System`Tape Installation'- Roof Panel Seams.
Apply ZIP System tape after all ZIP System"Roof&Wall sheathing panels are fully fastened to roof-framing members.Only.ZIP System tape should be used to
seal the seams of ZIP System panels.Ensure that the-panel surfaces are dry and free of any nails,sawdust-and other debris,or protrusions:Avoid stepping
on tape in high temperature environments.ZIP System tape,is a contact tape that requires pressure for an adequate seal.
Step 1.
Apply ZIP System tape to every vertical and horizontal panel seam. It is
at the discretion of the installer'whether to apply tape from the top down
or from the bottom up. However,working from the highest sections of
the roof and working down will minimize foot traffic on the tape.
Ensure that the tape is centered over the seam within+¢.1/2"to provide
adequate coverage and to ensure that wrinkles in the tape are minimized.
Ensure that tape lengths are continuous across the 8'horizontal edge
of the panels.If splices are unavoidable.,create an overlapping splice
of at.least 3"Apply moderate pressure onto the surface of the tape to
ensure a secure bond between the panel and the tape.
Use ZIP System tape gun or tape roller to apply pressure to the tape
and smooth out any wrinkles.
Take special care to remove any voids and/or trapped air at splice ,
areas and T-joints.. Ftrst Tape- ` "
Step 2.
- For valley areas of framing,we recommend you use 6"wide ZIP-System
tape.This tape is wider than panel seam tape and is designed to give you
optimal protection in valley areas.
- Starting from the bottom and working your way up,apply one-continuous
piece of 6"tape so that the center of the tape is over the valley seam.
- Use the tape gun or tape roller to apply pressure to the tape to ensure
proper contact with the panel,and to eliminate any wrinkles that might
have occurred in the tape.Take special care to seat tape completely
into the valley. -
.Note:
- It is important to pay extra attention to valley taping as water is
directed toward the valleys during rain events.
- Self-adhering ice-and water barriers may be required by code.ZIP
System tape is not•considered a replacement for self-adhering ice
and water barriers:Therefore,When self-adhering ice and water
i barriers are required,they should,be installed in addition to ZIP
System tape.
ZIP System®Roof&Wall Sheathing Installation Manua{
04
ZIP System""Tape Installation - Roof Panel Seams(continued)
Step 3. ;
If 6"ZIP System tape is not available,use two continuous pieces of 3.76'
ZIP System panel seam tape over the entire length'of the valley seam,
overlapping the pieces.on the valley seam by at least 111.
- Starting from the bottom,install the first piece of tape overlapping the
valley seam by at least 1 First piece
of tape
- Use the tape gun or tape roller to apply pressure to the tape to ensure
proper contact with the'panel and to eliminate any wrinkles'that might
have occurred in the tape.
- Apply the second piece of tape,overlapping the first piece in the valley
seam by 1°.
- Repeat use of the tape gun or roller to make sure the-tape is adequately
adhered and tightly pressed into the valley seam. second piece
Note:. of tape
It is important to pay extra attention.to valley taping as water Js,
directed toward.the"valleys during rain'events.'
Self-adhering.ice,and water barriers may be'required by code.ZIP
System tape is not considered a replacement for self-adhering ice
and water barriers:Therefore,when self-adhering ice'and water
barriers are required,they should be installed in addition to ZIP 1"ovedap '. n .
System tape.
Step 4..
To`provide temporary-weather protection to roof/wall intersections
of dormers or other,wood-sheathed projections, apply 2"of the tape
width,up the vertical projection-from where it intersects with the roof.
The remaining tape .width can be adhered to the,ZIP System roof -
sheathing panels.
Use the tape gun or tape roller toapply pressure to the tape and smooth
out any wrinkles.
Step 5.
Install ZIP System.tape over hips and ridges by centering the tape over
the peak seam.Apply tape in sufficient length to completely extend the
length of the hip or•ridge.
Starting from the lowest point of the hip and working up,press tape,into
place keeping tape centered over.the hip.Apply moderate pressure. -
onto the surface of the tape to ensure a'secure bond between the panel
and the tape.,
Cut ridge tape as required for ventilation prior to installing ridge vent.
Step 6.-
Tape over toe board nail holes once the toe boards are removed,working. .
from.the highest toe boards to the lowest.
05
Roof Covering Installation Instructions
ZIP System Roof&Wall sheathing is a code recognized sheathing and underlayment and is approved for use with the following roof coverings:
Asphalt-fiberglass Shingles
Metal Roofs(shingles and panels)
Clay Tile
Concrete Tile
Slate and Slate-type Shingles
- Wood Shingles
- Wood Shakes
When installing roof coverings,follow applicable codes and manufacturer's suggested instructions.Some roof coverings require a slip-sheet in addition to
conventional underlayment.Where slip-sheets are required,they should be installed over ZIP System sheathing.panels.
Note:Visit zipsystem.com for updates and installation details.
Asphalt-fiberglass Shingles
Apply asphalt shingles directly to ZIP System sheathing.For roofs with a slope of 2/12 or greater but less than 4/12,additional.underlayment may be required.
Install asphalt-fiberglass shingles according to applicable codes and manufacturer's installation instructions.
Metal Roof Coverings
Metal roof coverings may be applied to ZIP System sheathing provided that the roof covering manufacturer's installation instructions and applicable
codes are followed.
Fasteners used to secure the ZIP System Roof&Wall sheathing panels to supporting framing must be compatible with the specific metal roof covering
used.Galvanized fasteners shall be used with galvanized roof coverings, aluminum-zinc coated fasteners shall be used with aluminum-zinc coated roof
coverings and 300 series stainless steel fasteners shall be used with copper roofs.Stainless steel fasteners are acceptable with all metal roof types.
In addition,metal roof flashing shall also be made of a material compatible with the specific metal roof covering used.Apply metal shingles on roofs with
slopes of 3/12 or greater.
Clay and Concrete Tile Roof Coverings
ZIP System Roof&Wall sheathing is intended to replace the first layer in a two-layer or multi-layer underlayment system.When installing clay or
concrete tile roof coverings,follow the installation recommendations of FRSA/TRI 07320.Install tile roofs according to applicable codes and manufacturer's
installation instructions.
Slate and Slate-type Shingles
Apply slate and slate-type shingles on roofs with slopes of 4/12 or greater.Install slate and slate-type shingles according to applicable codes and manufacturer's
installation instructions.
Wood Shingles
ZIP System Roof&Wail sheathing is intended to replace the first layer of underlayment required by the IBC and/or the IRC.Additional layers of underlayment
may be required by code depending on the local climate. Apply wood shingles on roofs with slopes of 3/12 or greater. Install wood shingles according to
applicable codes and manufacturer's installation instructions.
Wood Shakes
ZIP System Roof&Wall sheathing is intended to replace the first layer of underlayment required by the IBC and/or the IRC.Additional layers of underlayment
may be required by code depending on the local climate.ZIP System roof sheathing is not to be construed as a replacement for interlayment.Apply wood
shakes on roofs with slopes of 4/12 or greater. Install wood shakes according to applicable codes and manufacturer's installation instructions.
ZIP System?Roof&.Wall Sheathing Installation Manual
.06
ZIP System®Sheathing Installation on Walls
Overview:ZIP System Roof&Wall sheathing is composed of ZIP System panels and ZIP System'seam sealing tape.ZIP System®Roof&Wall Sheathing
panels should be fully installed before the seam sealing tape is applied.The following installation steps are presented as a general outline of the installation
process.These are manufacturer installation recommendations please•visit zipsystem.com for a library of flashing and installation details.You are fully and
solely responsible for all safety requirements.Good construction and safety practices should be followed at all times.
Step 1. Install ZIP System Roof & Wall sheathing panels positioned
with the water-resistive barrier facing outside.The panels may
be installed with the long side of the panel oriented either
horizontally or,vertically to the framing members.Walls that are
designed to resist lateral shear forces and sheathed with wood
structural panels typically require solid framing or blocking behind
all panel edges. If oriented horizontally, block horizontal joints if
wall is designed for bracing or as a shear wall.
118" spacing between square edges of all adjacent panels is
recommended in accordance with industry standards for wood
sheathing installation.
8'and 4'
8'Panel Edges Panel Edges 4'Panel Edges
I, � II II
r ,
The unique edge profile is Maintain 1/8"space where, Maintain'1/8'space
designed to accommodate 8'panel edges meet 4' where 4'edges meet,
incremental panel panel edges,Unique edge Unique edge profile is on
expansion and does not profile does not provide 8'edges only.'
require manual gapping the full 1/6"recommended
along the 8'edges.' space in this situation.'
Step 2.Fasten the panels to the framing members with code approved
fasteners.Space fasteners 6"o.c.along supported edges and 12"
o.c.at intermediate supports, unless otherwise specified by local
code or the designer of record.It is the responsibility of the general
contractor to verify proper fastener type and spacing prior to•-
.
installation.Apply the fasteners 3/8"from the ends and corners.
An ideal installation would be where fastener heads are flush with
the panel surface. However, due to variations in materials and
limitations on equipment,this may be difficult to achieve in some
situations. It is not required to tape over overdriven fasteners
unless the fastener head creates a hole through the entire panel
thickness.Please see the technical tip "Overdriven Fasteners in
Zip System Roof and Wall Sheathing," on zipsystem.com for
more information.
07
ZIP System'Tape Installation - Wall Panel Seams
Apply ZIP System tape after all ZIP System Roof&Wall sheathing panels are fully fastened to wall-framing members.Only ZIP System tape should be used
to seal the seams of ZIP System panels.Ensure that the panel surface is dry and free of sawdust and dirt prior to taping.ZIP System tape is a contact
tape that requires pressure for an adequate seal.
Step 1. Tape all seams using ZIP System tape. Ensure that the tape
is centered over the seam within +/- 1/2" to provide adequate
coverage and that wrinkles in tape are minimal.
Use the ZIP System tape gun or roller to apply pressure to the tape
and smooth out any wrinkles.
Step 2. Wherever tape splices occur at a horizontal or vertical seam,create
an overlapping splice of at least 3°.
At T-joints,the tape pieces should overlap by at least 1".Apply
moderate pressure onto the surface of the tape to ensure a secure
bond between the panel and the tape.
Use the ZIP System tape gun or roller to apply pressure to the tape
and smooth out any wrinkles.
Take special care to remove any voids and/or trapped air at splice
areas and T-joints.
Step 3. Tape inside and outside corner seams. L.
Inside comer seam
Outside comer seam
s
Note:Tape over any areas of the panel or tape that are damaged during construction.
ZIP System®Hoof&Wall Sheathing Installation Manual
os
ZIPS stem -Window Installation DISCLAIMER:The following steps represent a general overview for the proper installation of window flashing.Please defer to/consult
Y the installation instructions of your window manufacturer as well as code requirements in your jurisdiction for full installation details.
Flanged Windows
1. Fasten the ZIP System sheathing 5. Cut a length of ZIP System tape or another
to the wood frame and install ` adhesive-backed flashing tape (must meet ICC-
ZIP System tape to all wall panel ES Acceptance Criteria for Flashing Materials
seams, as detailed in sections . �'
z� (AC148)) and apply to the header, ensuring that
02 and 03. the flashing overlaps the jamb flashings.'
Once the tape is in place,use the tape gun or roller
to seal the flashing to the sheathing.
' 'DO NOT tape bottom flange.
2. ZIP System tape may be used as pan flashing if 6. From the interior,apply low-pressure polyurethane
installed in accordance with flanged window \ foam(for windows)between the rough opening
installation details posted on zipsystem.com. \� and the window frame.(Caulk sealant compatible
Other adhesive-based flashing tapes(must meet with the sill flashing may be used at the sill if the
[CC-ES Acceptance Criteria for Flashing Materials opening between the sill flashing and window
(AC148))may be used as pan flashing if installed is too narrow to allow the use of low-pressure
per ASTM 2112-07.Apply the flashing to cover polyurethane foam.)
the bottom of the opening,overhanging onto the
sheathing by at least 2"and extending a minimum When using ZIP System tape, butyl, 100%
of 6"up each jamb. , silicone or polyurethane sealants are acceptable.
Do not use latex sealants with ZIP System tape. If
using another flashing tape, follow the flashing
manufacturer's recommendation in selecting a
sealant compatible with that flashing.
3. Apply sealant around inside face of mounting
flange. Sealant must be gapped at the sill Brick Mould Windows.
to permit drainage. Install and level window per a 1. Fasten the ZIP System sheathing
manufacturers installation instructions. Verify to the wood frame and install
sealant compatibility with window manufacturer. �.
�\ ZIP System tape to all wall panel
When using ZIP System tape as pan flashing, seams, as detailed in sections
butyl, 100% silicone or polyurethane sealants 02 and 03.
are acceptable.Do not use latex or other water-
based sealants.
4. Cut two pieces of ZIP System tape or another 2. If recommended by the window
adhesive-backed flashing tape (must meet ICC- manufacturer,cut a strip of wood
ES Acceptance Criteria for Flashing Materials \� to function as a back dam at the
(AC148))and apply to each of the window jamb MT sill. The wood strip should have
flanges, ensuring the jamb flashings overlap the \- a length equal to the width of the
sill flashing. �'� rough opening and a height and
width of at least 1/2".Position the
Once the tape is in place,use the tape gun or roller block at the inside edge of the
to seal the flashing to the sheathing. window frame.
09
ZIPSstem -Window Installation 111 1MER:Thefollowingstepsrepresentageneraloverviewfortheproperinstallationofwindowflashing.Pleasedeferto/consult
Ythe installation instructions of your window manufacturer as well as code requirements in your jurisdiction for full installation details.
Brick Mould Windows(continued)
3. ZIP System tape may be used as pan flashing if 7. Cut a piece of rigid head flashing so that when
installed in accordance with brick mould window installed,it is flush with the edges of the exterior
installation details posted on zipsystem.com. moulding of the window.Apply a bead of sealant
Other adhesive-based flashing tapes(must meet to the back and bottom surface of the rigid
ICC-ES Acceptance Criteria for Flashing Materials head flashing.Use sealant recommended by the
(AC148))may be used as pan flashing if installed flashing manufacturer.
per ASTM 2112-07.Apply the flashing to cover
the bottom of the opening,overhanging onto the
sheathing by at least 2°and extending a minimum
of 6°up each jamb.
8. Secure the rigid head flashing to ZIP System
wall sheathing.
4. For vertical jambs,cut ZIP System tape or another �\
adhesive-backed flashing tape (must meet ICC-
ES Acceptance Criteria for Flashing Materials
(AC148))and apply to each of the window jambs.
Ensure that they cover the entire inside of the rough
opening as well as overlap onto the sheathing by '
9. Cut a length of ZIP System tape or another
at least 2". Flashing shall also extend above the
adhesive-backed flashing tape(must meet ICC-ES
rough opening, such that it will project V beyond Acceptance Criteria for Flashing Materials(AC148))
the exterior trim of the window. and apply to the rigid head flashing, ensuring
that the adhesive-backed flashing overlaps the
Once the tape is in place,use the tape gun or roller
to seal the flashing to the sheathing. jamb flashings.
Once the tape is in place,use the tape gun or roller
to seal the flashing to the sheathing.
5. Apply sealant to jambs and header allowing for
drainage at the sill in accordance with window
manufacturer's installation instructions. When 10.From the interior, apply low-pressure polyurethane
using ZIP System tape,use,a butyl,polyurethane foam(for windows)between the rough opening and f
or 100% silicone sealant. Do hot use latex or the window frame. (Caulk sealant compatible with
other water-based sealants with ZIP System the sill flashing may be used at the sill it the opening
tape.When using another flashing tape,follow the between the sill flashing and window is too narrow x k
flashing manufac-turer's recommendations in to allow the use of low-pressure polyurethane foam.)
selecting a sealant compatible with that flashing.
When using ZIP System tape,butyl,100%silicone Y'
or polyurethane sealants are acceptable. Do not
use latex or other water-based sealants with ZIP
System tape. If using another flashing tape, follow
the flashing,manufacturer's recommendation in
6. Install and level window per manufacturer's selecting a sealant compatible with that flashing.
installation instructions.
ZIP System®Roof&Wall Sheathing Installation Manual
10
ZIP System - Penetration Openings DISCLAIMER:The following steps represent a general overview for the proper installation of penetration flashing.Please defer tolconsult
your code requirements in your jurisdiction for full installation details.
s WALL ASSEMSLY
\ ZIP SYSTEMA WALL SHEATHING
WOW OR LT.GA.METAL STUDS
WALL ASSEMBLY ,Z ;3?� I"CHGAPRECOMMENDEDAT r
ZIP SYSTEMS WALL SHEATHBIG S PANEL EOGES UNLESS
WOOD OR LT.GA-NETAL STUDS '3>i OTHERWISE PROVIDED BY •
MACHINED PROFILED EDGES
� ?.ice ......
tAYNCH GAPRECOMAIENDED AT -'Crr`���'`� �:'�
PANEL EDGES UNLESS •. 2W SYSTEMETAPE DNSTALLED
OMERWISEPROVIDEDBY $ ?2;0 y7. OVER ALL�OBTTS IN➢P SYSTEMS Y «"
MACHINED PROFILED EDGES >j ��: WALL SHEATHNG1
➢P SYSTEMD TAPE INSTALLED OVERLAP TAP£A M1NtA511M CF
OVER ALLJOIHTSwZjP SYSTEMD x 14Ntl ATALLT4DINT3
WALL SHEATHING).
NSTALLMP SYSTEM&WE AT All
•OVERLAP TAPEA R@IRI(PJ OF EXTERIOR CORNERS +`&
I-INCHATALLTJODITS
INSTALL➢P SYSTEMOTAPE A7 ALL FASTEN NG SYSTEMS WALL
tNTFAfORCORNERS BHEATNING ASREORG O L y
BESLDNG COFRELOROOR LOCAL D
BI1dDIH6 LOGE '
FASTEN➢P SYSTEMp WALL
SHEATHING AS REQUIRED BY
DESIGNER-OF-RECORD OR LOCAL
BUILDNG CODE
WALL ASSEMBLY WALL ASSEMBLY
ZIP SYSTEM®WALL SHEATHING - ZIP SYSTEM®WALL SHEATHING
WOOD OR LT.GA METAL STUDS. WOOD OR LT.G0.METAL STUDS
/1
VB-INCH GAP RECOMMENDED AT 1184NCH GAP RECOMMENDED AT `
PANEL EDGES UNLESS PANEL EDGES UNLESS
OTHERWISE PROVIDED BY - '` OTHERWISE PROVIDED BY
MACHINED PRO EDGES "` .• ? MACHINED PROFILED EDGES 2.;...;T,. .:..
INSTALL ZIP SYSTEM+&TAPE OR � � ��'3 ;
ADHESIVE BACKED FLASHING MUST �•.;;,ti?;%j : INSTALL ZIP SYSTEMSLTAPE G( t
n` MEET ADHESIVE BACKED FLASHING(MUST ¢'
MEET M.SIDES,
IN SEQUENCE FROM '\: •R• •- MEET AC14e)IN SEQUENCE FROM
BOTTOM,SHINGLE
HENLAP TOP To BOTTOM,SIDES,THEN TOP TO'
ENSURE SHINGLE LAP 6F ADHESIVE YP±,�_-.,.
•ENSURE SHINGLE LAP OF ADHESIVE '�}•.
BACKED FLASHING BACKED FLASHING
ZIP SYSTEM®TAPE(INSTALLED
�y,. 'ZIP SYSTEMO TAPE(INSTALLED
OVER ALL JOINTS IN ZIP SYSTEM® _ r?;"'.:.: �4 _y
WALL SHEATHING). ';^;."�+,:� OVER ALL JOINTS ZIP SYSTEM®
"' WALL SHEATHING).). ,
OVERLAP TAPE A MINIMUM Or
.IaNCH AT ALL T.IOINTS OVERLAP MINIMUM OF
14NCH
14NCH AT ALL iJOINTS
USE FLANGED VENT HOODS
USE FLANGED ELECTRICAL -
BOXES OR MEMBRANE FLASHING -�
TO PROVIDE FLANGES FOR
ELECTRICAL BOXES
ZIP System Sheath ing'Installation.Details on Walls=visit zipsystem.com for more details.
WALL ASSEMBLY - -
VINYLlWOOD/FIBERCEHENT SIDING BRICK VENEER '
(INSTALLED IN ACCORDANCE WITH AIR SPACE(AS PRESCRIBED BY
WALL ASSEMBLY
CLADDING MANUFACTURER'S LOCAL BUILDING CODE) \`
INSTALLATION RECOMMENDATIONS) ZIP SYSTEM®WALL SHEATHING
ZIP SYSTEM®WALL SHEATHING WOOD OR LT.GA.METAL STUDS
* WOOD OR LT.GA.METAL STUDS
TOP EDGE OF FLASHING TAPED TO TOP EDGE OF.FLASHING TAPED•
WALL SHEATHING WITH ZIP SYSTEMS WITH ZIP SYSTEMS TAPE OR
TAPE OR ADHESIVE BACKED ADHESIVE BACKED FLASHING.
FLASHING. (MUSTMEETAC148) (MUST MEET AC148) ,\
CODE APPROVED BASE �• `
CODE APPROVED FLASHING FLASHING
FOUNDATION WEEP HOLES(AS PRESCRIBED
BY LOCAL BUILDING CODE) /
WALLASSEMBLY - WALL ASSEMBLY
BRICK VENEER
VINYLIWOODIFISER CEMENT SIDING AIR SPACE(AS PRESCRIBED BY
QNSTALLED IN ACCORDANCE WRX LOCAL BUILDING CODE)
CLADDING MANUFACTURERSINS ZIP SYSTEMS WALL SHEATHING
ZIP SYSTEMS
WALL SHEATHING RECOMMENDATIONS). WOOD OR LT.GA.METAL STUDS
WOOODD O OR LT. _
WOOD LT.GA.METAL STUDS - '
1184NCH GAP RECOMMENDED AT PANEL E GAP RECOMMENDED AT
ti
�'� PANEL EDGES UNLESS
PANEL EDGES UNLESS •. OTHERVASE PROVIDED BY
OTHERWISE MACHINED PROFILED EDGES
MACHINED
PROFILED EDGES' W,
A
ZIP SYSTEMS TAPE(INSTALLED \� ZIP SYSTEMS TAPE(INSTALLED
OVER ALL EATHINJOINTS IN ZIP SYSTEM® \ �. OVER ALL AJOINTS HING). ZIP SYSTEMS J
WALL SHEATHING} I \ •`:by WALL BREATHING).
OVERLAP
TAPE A MINIMUM OF \ \ ^`Z; OVERLAP TAPE A MINIMUM OF
74NCH AT ALL TJOBITS �\\ 1-INCH AT ALL TJOINTS '
1/II-INCH GAP RECOMMENDED AT \PANEL EDGES UNLESS 118•INCH GAP RECOMMENDED ATOTHERMS \
MACHINED PROFILED
EDGES
-
PANEL EDGES UNLESS
MACMINEDPROFILEDEDGES OTHERWISMACHINED PROVIDED G
MACHINED PROFILED EDGES� '`�_
FASTEN ZIP SYSTEMS WALL
SHEATHING AS REWIRED BY FASTEN ZIP SYSTEMS WALL '
DESIGNER-OF-RECORD OR LOCAL SHEATHING AS REQUIRED BY
BUILDING CODE DESIGNER-OF-RECORD OR LOCAL
- BUILDING CODE -
Note:,For optimal air leakage reduction,all untaped edges of the panels can be caulked,gasketed or sealed with a weather stripping material.
Y
ZIP.System®Roof&Wall"Sheathing Installation Manual
12
ZIP System Sheathing Installation Details on Walls(continued)
WALL BEYOND
WALL ASSEMBLY BACKDAM PER WINDOW
BRICK VENEER MANUFACTURER'S INSTALLATION
AIR SPACE(AS PRESCRIBED BY RECOMMENDATIONS
LOCAL BUILDING CODE)
ZIP SYSTEM®WALL SHEATHING INSTALL'CODE-RECOGNIZED
WOOD OR LT.GA.METAL STUDS SILUPAN FLASHING 1N ROUGH
OPENING PRIOR TO WINDOW
TOP EDGE OF FLASHING TAPED ` INSTALLATION..
WITH ZIP SYSTEM®TAPE OR
ADHESIVE BACKED FLASHING. TOP EDGE OF FLASHING TAPED '
(MUST MEET AC148) \\ WITH ZIP SYSTEM®TAPE OR
ADHESIVE BACKED FLASHING.
,•'�� (MUST MEET AC148)
CODE APPROVED FLASHING
WEEPS(AS PRESCRIBED BY
WEEPS(AS PRESCRIBED BY s LOCAL BUILDING CODE)
LOCAL BUILDING CODE)
STEEL LINTEL CODE APPROVED FLASHING
INSTALL WINDOW IN WALL ASSEMBLY \�
ACCORDANCE WITH DETAILS BRICK VENEER
24A-24D OR 25A-25D AIR SPACE(AS PRESCRIBED BY
LOCAL BUILDING CODE)
ZIP SYSTEM®WALL SHEATHING .
WALL BEYOND WOOD OR LT.GA.METAL STUDS
WALL ASSEMBLY
CODE APPROVED CLADDING
(INSTALLED IN ACCORDANCE WITH
CLADDING MANUFACTURER'S
'IT
INSTALLATION RECOMMENDATIONS) .
EXTERIOR RIGID INSULATION
DRAINAGE PLANE(MIN.%")
ZIP SYSTEM(D WALL SHEATHING
WOOD OR LT.GA.METAL STUDS "
TOP EDGE OF FLASHING TAPED TO
WALL SHEATHING WITH ZIP SYSTEM
TAPE OR ADHESIVE BACKED
FLASHING. (MUST MEETAC148) "
CODE APPROVED FLASHING
FOUNDATION
Note:For optimal air leakage reduction,all untaped edges of the panels can be caulked,gasketed or sealed with a weather stripping material. -
tin
1
0 it
zoo v
v rY r '. y t �. � .• 't �tV A
her a .:♦� -.* i }.. /. � a:$ 3 � 4�1
Olt
.103
�• � ter. �. z t s y � { ,ys, •� -
y� ff i
e
.is ... Lit
L'.' � t' }.:c �t � � -� 1. �• •1 k c
�,` _ •<. _ .�'' � A•�yi•-�tmc RGii�d Dot kti?
3•. X` -^NG7t�+.tar�tj.Qa4'�gand vaA .. w ..
Am
:
- .,'- } � it`s'I ti �� -�cae�, r,,`• .L x ,
c
�
a
FE 3` R
y t 1.11.V 1♦�.a'-r.-. _.�`�#:..'�'r�,r ,-s�.�t,: .»a�' �_�r.�c.. � X,.,�. L ;i y� �� ,
ZIP SYSTEM® SHEATHING WITH HARD COAT STUCCO AT
H-2
BLOCK FOUNDATION WALL- OPTION A
TRADITIONAL HARD-COAT STUCCO
INSTALLED IN ACCORDANCE WITH THE LATH
MANUFACTURER'S OR THE PORTLAND
CEMENT ASSC.(PCA)
RECOMMENDATIONS WITH THE MOST ONE LAYER OF WATER-RESISTIVE
RESTRICTIVE CONTROLLLING. VAPOR-PERMEABLE BARRIER
WITH A PERFORMANCE AT LEAST
EQUIVALENT TO GRADE D
BUILDING PAPER.
ZIP SYSTEM®SHEATHING'
TOP EDGE OF WEEP SCREED
+ TAPED TO WALL SHEATHING
WITH ZIP SYSTEM®TAPE OR
ADHESIVE BACKED FLASHING.
•••: (MUST MEET AAMA 711 OR
AC1A8)
a
WOOD OR LT.GA.
METAL STUDS
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED
OVER TRANSITION JOINT(ZIP
SYSTEM TAPE MAY BE USED AS
THE BRIDGE FLASHING)
0
0
0
0
CODE-APPROVED
WEEP SCREED AT
BASE OF WALL
VERTICAL AND HORIZONTAL
CONTROL JOINTS AS NEEDED.
DESIGNER-OF-RECORD TO
SPECIFY TYPE AND LOCATION.
MASONRY BLOCK WALL
'ZIP SYSTEM®SHEATHING IS APPROVED TO REPLACE ONLY THE
FIRST LAYER OF A TWO•LAYER UNDERLAYMENT SYSTEM.
DRAWING NOT TO SCALE
o —/rS�Sfe/I7TM Sales Office:10925 David Taylor Drive
`? •/•l NC28262 r �IIR�� ENGINEERED
Suite 300-Charlotte, �Jv WOOD
m - SHEATHING&TAPE Telephone:800.933.9220-www.zipsystem.com
o These construction details are provided to assist in the installation of ZIP System®product s)and may not apply to
every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
r .
ZIP SYSTEM® SHEATHING WITH HARD COAT STUCCO AT
L F - H'2
BLOCK FOUNDATION WALL OPTION A
WALL ASSEMBLY
TRADITIONAL HARD-COAT STUCCO
METAL LATH
ONE LAYER WATER-RES.BARRIER
ZIP SYSTEM®SHEATHING'
WOOD OR LT.GA.METAL STUDS
TOP EDGE OF WEEP SCREED
TAPED TO WALL SHEATHING
WITH ZIP SYSTEM@ TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AAMA 711 OR
AC148)
CODE-APPROVED WEEP
SCREED AT BASE OF WALL
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED OVER
TRANSITION JOINT(ZIP SYSTEM ,
TAPE MAY BE USED AS THE BRIDGE I FLASHING)
MASONRY BLOCK WALL
LATH
TOP EDGE OF WEEP SCREED TAPED
TO WALL SHEATHING WITH ZIP
SYSTEM@.TAPE OR ADHESIVE BACKED
FLASHING. (MUST MEET AAMA 711 OR
AC148) \
TRADITIONAL HARD-COAT STUCCO \
INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S OR THE PORTLAND
CEMENT ASSC.(PCA)
RECOMMENDATIONS WITH THE MOST
RESTRICTIVE CONTROLLLING.
ONE LAYER OF WATER-RESISTIVE
VAPOR-PERMEABLE BARRIER WITH A
PERFORMANCE AT LEAST EQUIVALENT
TO GRADE D BUILDING PAPER. /
CODE-APPROVED WEEP
SCREED AT BASE OF WALL
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED OVER
TRANSITION JOINT(ZIP SYSTEM
TAPE MAY BE USED AS THE BRIDGE /
FLASHING) .
MASONRY BLOCK WALL ww�N�
*ZIP SYSTEM@ SHEATHING IS.APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO-LAYER UNDERLAYMEN��RR��'f'MIOPT TO SCALE
N ? ��� Sales Office'10925 David Taylor Drive *�B
�1system ENGINEERED
� Suite 300-Charlotte,NC 28262 • • WOODS
o SHEATHING TAPE Telephone:800.933.9220-www.zipsystem.com
These construction details are provided to assist in the installationZP System®products)and may not apply to
every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.