Loading...
HomeMy WebLinkAboutRevisionsOFFICE USE ONLY: DATE FILED: 7/30/2019 REVISION FEE: 516 LOCATION/SITE ADDRESS: 2260 Rock Road PERMIT # 1904-0473 RECEIPT # _64 PLANNING & DEVELOPMENT SERVI�/.EsGO BUILDING & CODE REGULATION DIVISI(y'1N" `;.1�r� ��"=-'�'�:� •^� p 1o9 2300 VIRGINIA AVENUE ,� 4 r � f��, "' �" 1��y e� FORT PIERCE, FL 34982-5662 9p�p Q,rr! (772) 462-1553 .3 a 'ridi /. APPLICATION FOR BUILDING P� '7 PROJECT INFORMATION ti fJl DETAILED DESCRIPTION OF PROJECT REVISIONS: 1. revised connector schedule for A04G and A05G trusses 2. revised roofing to metal Edge-loc by JA Taylor and roofing underlayment 3. revised energy calc and cubic volume on prints CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC1330685 BUSINESS NAME: Trefelner Construction Inc QUALIFIERS NAME: James Trefelner ADDRESS: 1760 Copenhaver Rd CITY: Fort Pierce STATE: FI PHONE (DAYTIME): 772-201-9833 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: Raul Valella ST. LUCIE CO CERT. #: 28600 FAX: ram: ZIP: 34945 ZIP: ADDRESS: 138 SE Naranja Ave CITY: Port St Lucie STATE: FI ZIP: 34983 PHONE (DAYTIME): 772-871-2457 SLCCC: 9123109 Revised 06130/17 I JUL 3 0 [q6+-Dy 3 FORM R405-2017 Q�� FLORIDA Ekff-lhGF � FF 1 �S�R CCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cuellar Residence Builder Name: Trefelner Construction Street: 2260 Rock Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL, 34945 Permit Number: Owner: Cuellar Residence Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3960.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 3960.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (3173.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 3173.00 ft2 6. Conditioned floor area above grade (ft2) 3173 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(339.1 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 140 a. U-Factor: Dbl, U=0.32 324.13 ft2 SHGC: SHGC=0.19 b. U-Factor: Dbl, U=0.38 15.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.20 a. Central Unit 46.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 4.702 ft. Area Weighted Average SHGC: 0.190 14. Hot water systems 8. Floor Types (3173.0 sqft.) Insulation Area a. Propane Tankless Cap: 1 gallons EF: 0.600 a. Slab -On -Grade Edge Insulation R=0.0 3173.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.107 Total Proposed Modified Loads: 106.44 PASS Total Baseline Loads: 109.28 1 hereby certify that the plans and specifications covered by Review of the plans and -tY3E ST. this calculation are in compliance with the Florida Energy specifications covered by this D ,y Off, Code. calculation indicates compliance �^- y /,,'�;`_-,,-°��.�� ti+ �O with the Florida Energy Code. PREPAR D Y: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as signed, is in compliance Florida Statutes. with the Florida Energy Code. / G'Op yyE'C4� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/7/2019 8:47 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Cuellar Residence Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 3173 Lot # Owner Name: Cuellar Residence Total Stories: 2 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Trefelner Construction Rotate Angle: 0 Street: 2260 Rock Road Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34945 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 3173 31730 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master Bath 206 2060 No 0 1 Yes Yes Yes 2 Toilet 32 320 No 0 1 No Yes Yes 3 Master Bedroom 280 2800 No 2 1 1 Yes Yes Yes 4 Closet 133 1330 No 0 1 No Yes Yes 5 Bedroom 2 217 2170 No 1 1 1 Yes Yes Yes 6 Bath 2 60 600 No 0 1 Yes Yes Yes 7 Bedroom 3 195 1950 No 1 1 1 Yes Yes Yes 8 Foyer 120 1200 No 0 1 Yes Yes Yes 9 Den 154 1540 No 2 1 Yes Yes Yes 10 Pantry 24 240 No 0 1 No Yes Yes 11 Stairwell 32 320 No 0 1 No Yes Yes 12 Hall 40 400 No 0 1 No Yes Yes 13 Great Room 391 3910 No 2 1 Yes Yes Yes 14 Kitchen 240 2400 Yes 1 1 Yes Yes Yes 15 Hall 88 880 No 0 1 No Yes Yes 16 Entry 76 760 No 0 1 Yes Yes Yes 17 1/2 Bath 32 320 No 0 1 Yes Yes Yes 18 Laundry 147 1470 No 1 1 Yes Yes Yes 19 Dining Room 169 1690 No 2 1 Yes Yes Yes 20 Bedroom 4 171 1710 No 2 1 1 Yes Yes Yes 21 Bath 3 66 660 No 0 1 Yes Yes Yes 22 Closet 2 42 420 No 0 1 Yes Yes Yes 7/7/2019 8:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 f FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 23 Bedroom 5 162 1620 No 2 1 1 Yes Yes Yes 24 Hall 72 720 No 0 1 Yes Yes Yes 25 Stairwell 24 240 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master Bath 35 ft 0 206 ft2 _-__ 1 0 0 2 Slab -On -Grade Edge Insulatio Toilet 1 ft 0 32 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulatio Master Bedroom 25 ft 0 280 ft2 1 0 0 4 Slab -On -Grade Edge Insulatio Closet 1 ft 0 133 ft2 1 0 0 5 Slab -On -Grade Edge Insulatio Bedroom 2 31 ft 0 217 ft2 1 0 0 6 Slab -On -Grade Edge Insulatio Bath 2 6 ft 0 60 ft2 1 0 0 7 Slab -On -Grade Edge Insulatio Bedroom 3 19 ft 0 195 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulatio Foyer 7 ft 0 120 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulatio Den 19 ft 0 154 ft2 1 0 0 10SIab-On-Grade Edge Insulatio Pantry 1 ft 0 24 ft2 ____ 1 0 0 11Slab-On-Grade Edge Insulatio Stairwell 1 ft 0 32 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio Hall 1 1 ft 0 40 ft2 1 0 0 13SIab-On-Grade Edge Insulatio Great Room 19 ft 0 391 ft2 1 0 0 14SIab-On-Grade Edge Insulatio Kitchen 14 ft 0 240 ft2 ___- 1 0 0 15SIab-On-Grade Edge Insulatio Hall 2 1 ft 0 88 ft2 1 0 0 16SIab-On-Grade Edge Insulatio Entry 9 ft 0 76 ft2 e__ 1 0 0 17SIab-On-Grade Edge Insulatio 1/2 Bath 12 ft 0 32 ft2 1 0 0 18SIab-On-Grade Edge Insulatio Laundry 27 ft 0 147 ft2 1 0 0 19SIab-On-Grade Edge Insulatio Dining Room 37 ft 0 169 ft2 --_- 1 0 0 20SIab-On-Grade Edge Insulatio Bedroom 4 47 ft 0 171 ft2 ____ 1 0 0 21SIab-On-Grade Edge Insulatio Bath 3 15 ft 0 66 ft2 ee 1 0 0 22SIab-On-Grade Edge Insulatio Closet 2 7 ft 0 42 ft2 1 0 0 23SIab-On-Grade Edge Insulatio Bedroom 5 42 ft 0 162 ft2 1 0 0 24SIab-On-Grade Edge Insulatio Hall 3 21 ft 0 72 ft2 1 0 0 25Slab-On-Grade Edge Insulatio Stairwell 2 4 ft 0 24 ft2 _—_ 1 0 0 7/7/2019 8:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF V Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3549 ft2 0 ft2 Light N 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3173 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Master Bath 0 Blown 206 ft2 0.1 Wood 2 Under Attic (Unvented) Toilet 0 Blown 32 ft2 0.1 Wood 3 Under Attic (Unvented) Master Bedroom 0 Blown 280 ft2 0.1 Wood 4 Under Attic (Unvented) Closet 0 Blown 133 ft2 0.1 Wood 5 Under Attic (Unvented) Bedroom 2 0 Blown 217 ft2 0.1 Wood 6 Under Attic (Unvented) Bath 2 0 Blown 60 ft2 0.1 Wood 7 Under Attic (Unvented) Bedroom 3 0 Blown 195 ft2 0.1 Wood 8 Under Attic (Unvented) Foyer 0 Blown 120 ft2 0.1 Wood 9 Under Attic (Unvented) Den 0 Blown 154 ft2 0.1 Wood 10 Under Attic (Unvented) Pantry 0 Blown 24 ft2 0.1 Wood 11 Under Attic (Unvented) Stairwell 0 Blown 32 ft2 0.1 Wood 12 Under Attic (Unvented) Hall 1 0 Blown 40 ft2 0.1 Wood 13 Under Attic (Unvented) Great Room 0 Blown 391 ft2 0.1 Wood 14 Under Attic (Unvented) Kitchen 0 Blown 240 ft2 0.1 Wood 15 Under Attic (Unvented) Hall 2 0 Blown 88 ft2 0.1 Wood 16 Under Attic (Unvented) Entry 0 Blown 76 ft2 0.1 Wood 17 Under Attic (Unvented) 1/2 Bath 0 Blown 32 ft2 0.1 Wood 18 Under Attic (Unvented) Laundry 0 Blown 147 ft2 0.1 Wood 19 Under Attic (Unvented) Dining Room 0 Blown 169 ft2 0.1 Wood 20 Under Attic (Unvented) Bedroom 4 0 Blown 171 ft2 0.1 Wood 21 Under Attic (Unvented) Bath 3 0 Blown 66 ft2 0.1 Wood 22 Under Attic (Unvented) Closet 2 0 Blown 42 ft2 0.1 Wood 23 Under Attic (Unvented) Bedroom 5 0 Blown 162 ft2 0.1 Wood 24 Under Attic (Unvented) Hall 3 0 Blown 72 ft2 0.1 Wood 25 Under Attic (Unvented) Stairwell 2 0 Blown 24 ft2 0.1 Wood WALLS ft ()Mt Adjacent To IAI-11 Type Cavity Width Spacele FtEt Height InArea Sheathing Framing Solar RAIRIlle Below _ 1 N Exterior Concrete Block - Ext InsMaster Bath 4.1 25 0 10 0 250.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Ext InsMaster Bath 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 3 E Exterior Concrete Block - Ext InMbster Bedro 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 4 S Exterior Concrete Block - Ext InNbster Bedro 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 7/7/2019 8:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 10 Space Wnfl TypePA/M.n. Et In Et' In Area P-Vnhjt� Fraction AhSnr rrarip0l, 5 N Exterior Concrete Block - Ext InsiBedroom 2 4.1 17 0 10 0 170.0 ft2 0 0 0.6 0 _ 6 W Exterior Concrete Block - Ext InsrBedroom 2 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 7 W Exterior Concrete Block - Ext Insul Bath 2 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 8 N Exterior Concrete Block - Ext InsLBedroom 3 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 9 W Exterior Concrete Block - Ext InsLOedroom 3 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 10 W Exterior Concrete Block - Ext Insul Foyer 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 11 S Exterior Concrete Block - Ext Insul Den 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 _ 12 W Exterior Concrete Block - Ext Insul Den 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 13 E Exterior Concrete Block - Ext InsGreat Room 4.1 19 0 10 0 190.0 ft2 0 0 0.6 0 14 E Exterior Concrete Block - Ext Insul Kitchen 4.1 3 0 10 0 30.0 ft2 0 0 0.6 0 15 S Exterior Concrete Block - Ext Insul Kitchen 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 _ 16 E Exterior Concrete Block - Ext Insul Entry 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 17 S Exterior Concrete Block - Ext Insul Entry 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block - Ext Insult/2 Bath 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 19 S Exterior Concrete Block - Ext Insul1/2 Bath 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 20 N Exterior Concrete Block - Ext Insul Laundry 4.1 1 0 10 0 10.0 ft2 0 0 0.6 0 21 S Exterior Concrete Block - Ext Insul Laundry 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 22 W Exterior Concrete Block - Ext Insul Laundry 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 _23 N Exterior Concrete Block - Ext InOlning Room 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 _ 24 E Exterior Concrete Block - Ext Indi)lning Room 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _25 S Exterior Concrete Block- Ext IndOlning Room 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 26 N Exterior Concrete Block - Ext InsLOedroom 4 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 _27 E Exterior Concrete Block - Ext InsiBedroom 4 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 28 S Exterior Concrete Block - Ext InsiBedroom 4 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 29 W Exterior Concrete Block - Ext InsLOedroom 4 4.1 3 0 10 0 30.0 ft2 0 0 0.6 0 30 N Exterior Concrete Block - Ext Insul Bath 3 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 31 S Exterior Concrete Block - Ext Insul Bath 3 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 _32 N Exterior Concrete Block - Ext Insul Closet 2 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 33 N Exterior Concrete Block - Ext InsLOedroom 5 4.1 15 0 10 0 150.0 ft2 0 0 0.6 0 34 S Exterior Concrete Block - Ext InsrBedroom 5 4.1 15 0 10 0 150.0 ft2 0 0 0.6 0 35 W Exterior Concrete Block - Ext InsiBedroom 5 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 _36 N Exterior Concrete Block - Ext Insul Hall 3 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 37 E Exterior Concrete Block - Ext Insul Hall 3 4.1 3 0 10 0 30.0 ft2 0 0 0.6 0 _ 38 S Exterior Concrete Block - Ext Insul Hall 3 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 39 S Exterior Concrete Block - Ext InsuStairwell 2 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood Foyer None .39 3 8 24 ft2 7/7/2019 8:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low E Double Yes 0.38 0.2 N 15.0 ft2 1 ft 7 in 1 ft 4 in None None 2 E 3 Vinyl Low-E Double Yes 0.32 0.19 N 24.0 ft2 1 ft 7 in 1 ft 4 in None None 3 S 4 Vinyl Low-E Double Yes 0.32 0.19 N 18.0 ft2 1 ft 7 in 1 ft 4 in None None 4 W 6 Vinyl Low-E Double Yes 0.32 0.19 N 18.0 ft2 1 ft 7 in 1 ft 4 in None None 5 W 7 Vinyl Low-E Double Yes 0.32 0.19 N 4.0 ft2 1 ft 2 in 1 ft 4 in None None 6 W 9 Vinyl Low-E Double Yes 0.32 0.19 N 18.0 ft2 7 ft 0 in 1 ft 4 in None None 7 W 10 Vinyl Low-E Double Yes 0.32 0.19 N 18.7 ft2 1 ft 7 in 1 ft 4 in None None 8 W 12 Vinyl Low E Double Yes 0.32 0.19 N 18.0 ft2 7 ft 0 in 1 ft 4 in None None 9 E 13 Vinyl Low-E Double Yes 0.32 0.19 N 48.0 ft2 10 ft 0 in 1 ft 4 in None None 10 E 13 Vinyl Low-E Double Yes 0.32 0.19 N 18.7 ft2 10 ft 0 in 1 ft 4 in None None 11 S 15 Vinyl Low-E Double Yes 0.32 0.19 N 24.0 ft2 1 ft 7 in 1 ft 4 in None None 12 E 16 Vinyl Low-E Double Yes 0.32 0.19 N 8.0 ft2 1 ft 7 in 1 ft 4 in None None 13 S 17 Vinyl Low-E Double Yes 0.32 0.19 N 24.0 ft2 10 ft 0 in 1 ft 4 in None None 14 S 21 Vinyl Low-E Double Yes 0.32 0.19 N 12.0 ft2 10 ft 0 in 1 ft 4 in None None 15 W 22 Vinyl Low-E Double Yes 0.32 0.19 N 18.0 ft2 1 ft 7 in 1 ft 4 in None None 16 N 23 Vinyl Low-E Double Yes 0.32 0.19 N 26.4 ft2 1 ft 7 in 1 ft 4 in None None 17 E 24 Vinyl Low-E Double Yes 0.32 0.19 N 26.4 ft2 1 ft 7 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 3701.8 203.23 382.2 .2224 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 46 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None 7/7/2019 8:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V --- Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 35 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan HeatinJan Feb Feb Mar Mar ki Apr APr Jul May Jun Jul Ma X Jun rl Au AuSep rl Se Oct Oct Nov Nov Dec Dec Ventin Jan Feb Mar [X Apr [ May [ Jun Jul Aug Se [X Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/7/2019 8:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Den Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 lbs/sq.ft. ft2 ft 0.3 Stairwell Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 lbs/sq.ft. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Entry Default(8 Ibs/sq.ft. ft2 It 0.3 1/2 Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 5 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 3 Default(8 Ibs/s .ft. ft2 ft 0.3 Stairwell 2 7/7/2019 8:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 5 13. Cooling system: Capacity 46.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 3173 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.323 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.190 14. Heating system: Capacity 34.0 c) Area 7c. 339.1 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF 0.60 A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: 7h Address of New Home: 2260 Rock Road City/FL Zip: Fort Pierce, FL 34945 7/7/2019 8:47:54 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Flame Spread Index & Smoke Developed Index Insulation Flame Spread: Not to exceed 25 Insulation Smoke Developed Index: Not to exceed 450 Wall Finishes: Not greater than 200 Ceiling Finishes: Not greater than 200 Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy W O 7 0 i-� .co Building Code 6th Edition Florida Building Code: Residential 2014 National Electric Code NFPA 70 Scope of Work New Two level CBS single family residence Design Loads Roof Live Load: 20.0 p.s.f. Floor Live Load: 40.0 p.s.f. Wind Speed: 160 MPH Wind Importance Factor: I D Building Category: II Wind Exposure: C Internal Pressure Coefficent: .18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. Building Data Occupancy Type: Group R Construction Type: V Number of Stories: Two Project Area: 4292 s.f. Total Cubic Volume: 31,730 c.f. Area Tabulation 1 st Living 2636 2nd Living 537 Total Living 3173 Porch 275 Entry 264 Carport 472 Breezeway 108 Total 4292 �/— 4 `i7-3 REVIsil'ON rermitting D st. Luao �ountyant E EE `Fos CO E CompliU rICE U . LUc1E COUNTY 00 ST SOCC Q M 0 L. ® w Ln Z m J � Ci `'0 C: N -- W � o w O .N in a J > X ~ co N W U U N u' o T 7 O 'y` T UT^l % �w 0 Q^ > ~ LOE� � C N = U O (U *- o Z r n co o I CV Q LU n 00 n/ oo M T W Z i..0 N W [Y 2 O H U) U date 5, L J 1W C C i do Q LL C C: 7 O U U J ++ U) revision 7/11/19 1 Cubic Volume drawn 8.1, checked s.l. date 2/14/19 scale As Noted job number 19001 sheet A-1 • PRODUCT APPROVAL Approval Glass Building Rated Product Rated Product Model Number Manufacturer Attachment Method Number Type Design Pressures Design Pressures Head: 12" max. from corners & 30"o.c. max. Jambs: SH-5500 5/16" 12' max. from corners & 17.7"" max. 5"" each side of NOA: 15-0519.05 Windows Singlehung PGT Industries Lam. meeting rail. Use 3/16" Tapcon with 1 1/4" embedment +33.5 -44.8 +/- 50.0 into concrete FL#: 17184.5 Fiberglass 5/16'" 6"" from corners & 14""o.c. at jambs. 1/4"" tapcon FL#: 17184.1 Swing Doors Door Plastpro Lam screws with 1 1 /4'" embed. into conc. +33.5 -36.3 50.0 Approval Building Rated Product Rated Product Model Number Manufacturer Attachment Method Number Design Pressures Design Pressures NOA: 18-1023.17 Roofing#10-13, Edge-Loc JA Taylor Roofing x I" Long pancake head screws with washer at each -45.0 -59.75 Rib 16" p.c. in field and 6 3/4" o.c. in corners. FL#: 13192.2 Siding Hardie Plank James Hardie Fasteners shall be ET&F block nail .30 Head dia. .14 Shank dia. and 1 1/4- long. 21_o.c. max. spacing -50.0 -92.0 FL: 9777.7 Roofing Underlayment Weatherlock Specialty Owens Corning Direct attachment to plywood deck -45.0 -142.5 IR![-- -' -7 - -- - - IAA _ II PLUMBING NOTES: Plumber to consult with contractor and equipment ordered 2 1 for rough in dimensions. \ 2 Verify all dimensions with the floor plan. The floor plan dimensions dictates all other dimensions on other sheets. 2 2 Do not scale drawings, if any conflicts arise, contact the 3 2 Architect or Engineer for clarification prior to construction. 3 , , All sanitary lines 2- or less shall have a slope of 1/4- per foot minimum. 3 All sanitary lines above 2- shall have a slope of 1/8" per 3""v.t.r. 2 2 3 3 foot minimum. J Provide Anti -Scalding Valve in all showers. 1 3 2 Lowest living area floor elevation (refered as 0.00') to be 2" set by a professional land surveyor to the required building 2- v.t.r. department elevation, but not less than 18- above the crown Tub LAV Wind Zone -Roof Plan of the road. W.C. 2- AUTO SINK VENT 3- v.t.r. 2- J 1 1 2" SINK 2- 12- v.t.r. 2 ! v.t.r. J LAV 2„ 3" SINK AV 3- W.C. WASHER 3"" v.t.r. 2- J 3„ 2„ LAV SHWR. 3„ 3„ 2" 2„ W.C. 3„ 2- 2„ LAV 3- DOG WASH TUB W.C. 2 2„ 3„ 3„ C.O. Plumbing contractor to provide a water hammer & shut off valve at SHWR. each fixture Insulate all hot water lines to sewer Plumbing Riser Diagram system Connector Schedule Truss Bearing Truss .Connector OnTy" Connector Fasteners Point Uplift ID Uplift (1) 5/8- dia. ATR with a min. emedment of 12- AS 4444 MGT 1 3965 Drill and Epoxy and (22) 1Od to Girder HETA20 1 2500 (12) 16d Ao4G 3 Ply (1) 5/8"" dia. ATR with a min. emedment of 12`" AT 6123 MGT I 3965 Drill and Epoxy and (22) 1Od to Girder HETA20 1 2500 (12) 16d (1) 5/8- dia: ATR with a MGT 1 3965 min. emedment of 12" AH 4723 Drill and Epoxy and (22) 1Od to Girder HETA20 1 2500 (12) 16d A05G 3 Ply (1) 5/8`" dia. ATR with a min. emedment of 12- MGT I 3965 Drill and Epoxy and (22) BA 4685 1Od to Girder HETA20 1 2500 (12) 16d D01G A 2081 HHETAI6 1 2235 (10) 10d x 1 1/2 K 2099 I Ply All trusses Each <1810 HETA20 1 1810# (9) 1 Od x 1 1 /2" <1810 HETA20 1 1810# (9) 1Od x 1 1/2- to CBS Brng. All trusses Each <1000 MTS18 1 1000# (14) 1Od x 1 1/2- to Frame Bring. <1000 MTS18 1 1000# (14) 1Od x 1 1/2" Valley Supporting Framing (4) 1 Od Trusses <250# VTCR 1 370# Valley Truss (3) 1 Od x 1 1/2- Connector Notes: BEAM TO C.B.S. --Z HUC210-2 (18) 1/4" x 2 3/4- Titen Screws to CBS and (10) 1 Od to Wood Beam (TYPICAL) See Typical Wall Section F.F.E. Do not substitute connectors Do not sheath trusses before all straps are in place Attach valley trusses and piggy back trusses, if present, to main trusses per truss manufacturer drawing. Truss to truss connection by truss company, installed per manufacturers specs. Lateral forces perpendicular and parallel to wall has been considered (less than 300 p.l.f.) Contractor to approve temporary bracing to prevent toppling of trusses, see HIB-9. Other specs, if different from above, have priority. A.T.R. = All Treaded Rod Drill and Epoxy Set all A.T.R. Use either-Hilti- C-100 or Simpson Epoxy Tie Epoxy Provide equal number of studs under girders equal to the number of plys. Cast in place sill or Tie Beam Option In the event that precast products are damaged in the field cast in place sills and tie beams may be used (not to exceed 5'-10") Typical cast in place tie beam to be a min. 8„ x 1211 with (2) #5 top and (2) #5 bottom Safe Load Table Notes 1. All values based on minimum 4" nominal bearing. Exception: Safe loads for unfilled U lintels must be reduced by 20°% if bearing length is less than 6 1/2". 2. N.R. = Not Rated 3. Safe loads are superimposed allowable loads. 4. One #7 rebar may be substituted for two #5 rebar in 8 inch U lintels only. 5. All safe loads in units of pounds per linier foot. 6. All safe loads are based on simply supported span. 7. Safe load ratings based on rational design analysis per ACI 318 and ACI 530. Installation Notes 1. Installation of U lintels must comply with architectural and/or structural drawings. 2. U lintels can be field cut to the required length. 3. Cast in place concrete may be provided in composite U lintel in lieu of concrete masonry units. 4. The exterior surface of U lintels installed in exterior concrete masonrywalls shall have a coating of stucco g applied in accordance with ASTM C-926 or other approved coating. 5. Concrete masonry units used in composite U lintel shall be laid in a running bond. 6. Shore composite lintels as required 7. U lintels are manufactured with a 5 1/2" long notch at both ends to accomodate vertical call reinforcing and grout. Pre Engineered Trusses 24" o.c. Stucco Ceiling J Wrap wood beam with paper backed - wire lath and stucco See Floor Plan Entry & Porch SI See Connector Schedule for Roof to Beam Connection (2) 2 x 12 p.t. beam bond together with I6d 6" o.c. Fasten to columns with (2) HETA16 with (14) 1Dd per strap 8x8CBS Column Beyond with (1) #5 vertical hooked into footing in grout filled cell 36- Tall Railing with Verticals 4-o.c. max. Style and Selection by Owner 4 x 4 p.t. 48-o.c. max. � II / F-1 4 3000# Fibermix °oncreteongrade Entry & Porch Section Clean, Compacted Treated Fill Cast Crete Lintel Schedule Grade All Rebar to be #5 Grade 60 min. 00 00 eocc 00 00 Q. M N LL L LU Z U J LA CIO act I � W --� � 00 Li p .. Cal W J � !� .. X . NrZ Q m Li ~ LUN 3: Cz U o � o 0 7 UJ O T a) CD T �4y-) V J 1 0.00' > U LLI r \� / M M Lo l = Uoz O Lill N r co O I Call 4 v 00 M T MARK LENGTH OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD BEAM SPECS. L-1 3'-10- 6113 681 3079 266 81`16 1 BAT L-2 3'-0- 6113 935 3547 356 81`16 1 BAT L-3 10'-6- 2093 1053 1185 301 81`22 1 BA T L-4 T-10" 1843 152 1133 50 81`161BAT L-5 4'-6- 6113 415 2724 70 81`16 IBA T L-6 T-0- 2459 200 1462 50 8RF14 1B/2T L-7 3'-8" 6113 1100 3079 326 81`16 1 BAT L-8 4'-6- 8060 250 4224 100 8RF22 I BAT L-9 5`10- 4360 935 2093 356 81`16 1BAT L-10 T-0- 2661 415 1634 190 81`16 1BAT L-11 1'-4- 6113 200 3547 50 81`16 1 BAT L-12 21'-0- 845 676 531 326 81720 1B/2T Mim. Beam depths shown, beams may be increased without coment At Lintels 30- deep or larger, provide (1) #4 vertical rebar tied to Horiz. steel at 24"o.c. along length of lintel Fb reba, at too in m read quanta of zb rebar at bottom of lintel fthrib CraA a tv = CC)w°d,n _ 8F16-1 B/1 T 5/8#9 rebar at bi nalJ 'iaoop of lintal ali nominal 8- Nominal Lintel Type Designation Composite U Lintel Materials ,. Grout per ASTM C476 fg=3000 psi with maximum 3/8 inch aggregate and 8 to I I inch slump. 2. Reber per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM C90 with minimum net Brea compressive strength = 1900 psi 4. Mortar per ASTM C270 Type M or S LU U L c� LU U LL N O Lu i✓ O o o 4-) a° U Q J O i U date revision 7/1/19 Product Approval Connector Schdl. drawn s.i. checked s.i. date 2/14/19 scale As Noted job number 19001 sheet A-5