RE: Rebecca McCoy
12348 Harbour Ridge Blvd.Unit 3-2
Palm City,Florida 34990
To whom it may concern:
The design pressures (PSF)for the above location to replace (12)windows and(1) sliding
glass door(20'component height) are as follows:
ZONE 4-+43.0.' -46.5
ZONE 5 -+43.0—57.4
Zone 5 is defined as 5' of building wall from building corners.
Zone 4 is defined as all other wall space.
Design pressures calculated with 160mph ultimate design wind speed and 124 nominal
wind speed, importance factor 1.0, exposure D, surface exposure D, category II, internal
pressure coefficient+.18, -18.