Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's file COPY. FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method E Project Name: DIAZ RESIDENCE Builder Name: ASSOCIATED HOMES INC. Street: PALMETTO DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE,FL, Permit Number. i Owner: WILLIAM AND JENNIFER DIAZ Jurisdiction: Design Location: FL, Fort Pierce County.: St. Lucie(Florida Climate Zone 2) P 1. New construction or existing New(From Plans) 9. Wall Types(2025.3 scift.) Insulation Area ! 2. Single family or multiple family Single-family a. Concrete Block-Int Insul, Exterior R=9.1 1798.90 ft2 b. Frame-Wood,Adjacent R=11.0 226.33 ft2 1 3. Number of units,if multiple family 1 c.NIA R= f? 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2310.0 sgft.) Insulation Area a. Under Attic(Vented) R=30.0 2310.00 ft2 ! 6. Conditioned floor area above grade(ft2) 2310 b.N/A R= ft2 N/Az Conditioned floor area below grade (ft2) 0 c.11.Ducts R= fts R ft2 7. Windows(251.2 sgft.) Description Area a.Sup:Attic, Ret:Attic,AH:LAUNDRY 6 185 a. U-Factor: Sgl,-U=0.65 251.20 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 42.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems � 8. Floor Types (2310.0 sgft) Insulation Area a. Electric Cap:40 gallons a. Slab-On-Grade Edge Insulation R=0.0 2310.00 ft2 EF:0.980 b. Conservation features I b.N/A R= ft2 None 1 c.N/A R= ft2 15.Credits None � Glass/FloorArea: 0.109 Total Proposed Modified Loads: 66.80 PASS Total Baseline Loads: 73.52 i I hereby certify that the plans and specifications covered by Review of the plans and 0�'YKS ST,q?� this calculation are in compliance with the Florida Energy specifications covered by this _ O Code. calculation indicates compliance with the Florida Energy Code. ti rgrrr " ti4••,��„ PREP D BY: - Before construction is completed DATE: this building will be inspected for compliance with Section553.908 * ° ! I hereby certify that this building,as designed,is in compliance Florida Statutes.. I with the Florida Energy Code. G'Olj we�o OWNER/A ENT 1 -/4--/ BUILDING OFFICIAL: DATE: 3 Z 1 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage i test report in accordance with R402.4.1.2. 2/9/2017 2:31 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: DIAZ RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2310 Lot# Owner: WILLIAM AND JENNIFER DI Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: ASSOCIATED HOMES INC. Rotate Angle: 0 Street: PALMETTO DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fah, No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/E)dsting: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2310 21057 SPACES. Number Name Area Volume Kitchen Occupants' Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 252 2293.2 No 0 1 1 Yes Yes Yes 2 WIC 1 40 324 No 0 1 Yes Yes Yes 3 WIC 2 36 291.6 No 0 1 No Yes Yes 4 MASTER BATH 151 1223.1 No 0 1 Yes Yes Yes 5 OFFICE 161 1686.7 No 0 1 Yes Yes Yes 6 FOYER 112 1131.2 No 0 1 Yes Yes Yes 7 DINING ROOM 154 1555.4 No 0 1 Yes Yes Yes 8 FAMILY ROOM 358 3615.8 No 0 1 Yes Yes Yes 9 KITCHEN 176 1777.6 Yes 0 1 No Yes Yes 10 CAFE 80 808 No 0 1 Yes Yes Yes f 11 CLST 2 16 129.6 No 0 1 No Yes Yes 12 BEDROOM 4 140 1134 No 0 1 1 Yes Yes Yes 13 CLST 4 20 162 No 0 1 No Yes Yes 14 M.TOILET 54 437.4 No 0 1 Yes Yes Yes l 15 BATH 2 58 469.8 No 0 1 Yes Yes Yes 16 BEDROOM 2 148 1198.8 No 0 1 1 Yes Yes Yes 17 HALL 69 558.9 No 0 1 No Yes Yes 18 BEDROOM 3 134 1085.4 No 0 1 1 Yes Yes Yes 19 CLST 3 19 153.9 No 0 1 Yes Yes Yes I 20 LAUNDRY 60 '486 No 0 1 No Yes Yes 21 BATH 3 66 534.6 No 0 1 Yes Yes Yes 2/9/2017 2:31 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet i 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 42 ft 0 252 ftz - 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 8 ft 0 40 ftz — 0 1 0 3 Slab-On-Grade Edge Insulatio WIC 2 1 ft 0 36 ftz — 0 1 0 4SIab-On-Grade Edge Insulatio MASTER BATH 10 ft 0 151 ftz — 0 1 0 • 5SIab-On-Grade Edge-Insulatio OFFICE 15 ft 0 167 ftz — 0 1 0 6 Slab-On-Grade Edge Insulatio FOYER 8 ft 0 112 ftz — 0 1 0 7Slab-On-Grade Edge Insulatio DINING ROOM 11 ft 0 154 ftz — 0 1 0 8 Slab-On-Grade Edge Insulatio FAMILY ROOM 16 ft 0 358 ftz — 0 1 G 9 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 176 ftz _. 0 1 0 10SIab-On-Grade Edge Insulatio CAFE 8 ft 0 80 ftz _ 0 1 0 11SIab-On-Grade Edge Insulatio CLST,2 1 ft 0 16 ft= — 0 1 0 12Slab-On-Grade Edge Insulatio BEDROOM 4 12 ft 0 '140 ftz — 0 1 0 13SIab-On-Grade Edge Insulatio CLST 4 1 ft 0 20 ftz — 0 1 0 14SIab-On-Grade Edge Insulatio M.TOILET 15 ft 0 54 ftz _ 0 1 0 15SIab-On-Grade Edge Insulatio BATH 2 6 ft 0 58 ftz — 0 1 0 16SIab-On-Grade Edge Insulatio BEDROOM 2 21 ft 0 148 ftz — 0 1 0 17SIab-On-Grade Edge Insulatio HALL 1 ft 0 69 ftz _ 0 1 0 18SIab7On-Grade Edge Insulatio BEDROOM 3 22.9 ft 0 134.ftz — 0 1 0 19SIab-On-Grade Edge Insulatio CLST 3 2 ft 6 19 ftz — 0 1 0 I 20SIab-On-Grade Edge Insulatio LAUNDRY 1 ft .0 60 ftz — 0 1 0 21SIab-On-Grade Edge Insulatio BATH 3 6ft 0 66 ftz _ 0 1 0 ROOF / Roof Gable Roof Solar SA Emift Emitt Deck Pitch V # Type Materials Area Area. Color Absor. Tested Tested Insul. (deg) l 1 Hip Composition shingles 2502 ftz O'ftz Medium OA No 0.9 No 0 22.6 j ,l ATTIC j V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 2310 ftz N N i t 2/9/2017 2:31 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 1 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 252 ft2 0.1 Wood 2 Under Attic(Vented) WIC 1 30 Blown 40 ft2 0.1 Wood 3 Under Attic(Vented) WIC 2 30 Blown 36 ft2 0.1 Wood 4 Under Attic(Vented) MASTER BATH 30 Blown 151 ft2 0.1 Wood 5 Under Attic(Vented) OFFICE 30 Blown 167 ft2 0.1 Wood 6 Under Attic(Vented) FOYER 30 Blown 112 ftZ 0.1 Wood 7 Under Attic(Vented) DINING ROOM 30 Blown 154 ft2 0.1 Wood i 8 Under Attic (Vented) FAMILY ROOM 30 Blown 358 ft2 0.1 Wood 9 Under Attic(Vented) KITCHEN 30 Blown 176 ft2 0.1 Wood 10 Under Attic(Vented) CAFE 30 Blown 80 ft2 0.1 Wood 11 Under Attic(Vented) CLST 2 30 Blown 16 ft2 0.1 Wood 12 Under Attic(Vented) BEDROOM 4 30 Blown 140 ft2 0.1 Wood 13 Under Attic(Vented) CLST 4 30 Blown 20 ft2 0.1 Wood 14 Under Attic(Vented) M.TOILET 30 Blown 54 ft2 0.1 Wood 15 Under Attic(Vented) BATH 2 30 Blown 58 ft2 0.1 Wood 16 Under Attic(Vented) BEDROOM 2 30 Blown 148 ft2 0.1 Wood { 17 Under Attic(Vented) HALL 30 Blown 69 ft2 0.1 Wood 18 Under Attic(Vented) BEDROOM 3 30 Blown 134 ft2 0.1 Wood 19 Under Attic(Vented) CLST 3 30 Blown 19 ft2 0.1 Wood 20 Under Attic(Vented) LAUNDRY 30 Blown 60 ft2 0.1 Wood 21 Under Attic(Vented) BATH 3 30 Blown 66 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 E Exterior Concrete Block-Int InsMASTER BE 9.1 10 0 9 1 90.8 ft2 0 0 0.6 0 2 S Exterior Concrete Block-Int InsWASTER BE 9.1 14 0 9 1 127.2 ft2 0 0 0.6 0 3 W Exterior Concrete Block-Int InsMASTER BE 9.1 18 0 9 1 163.5 ft2 0 0 0.6 0 4 W Exterior Concrete Block-Int Insul WIC 1 9.1 8 0 8 1 64.7 ft2 0 0 0.6 0 II _ 5 W Exterior Concrete Block-Int InsWASTER BA 9.1 10 0 8 1 80.8 ft2 0 0 0.6 0 _ 6 N Exterior Concrete Block-Int Insul OFFICE 9.1 12 0 10 1 121.0 ft2 0 D 0.6 0 _ 7 W Exterior Concrete Block-Int Insul OFFICE 9.1 3 0 10 1 30.3 ft2 0 0 0.6 0 j 8 N Exterior Concrete Block-Int Insul FOYER 9.1 8 .0 10 1 90.7 ft2 0 0 0.6 0 9 N Exterior Concrete Block-Int InsININING ROO 9.1 11 0 10 1 110.9 ft2 0 0 0.6 0 10 S Exterior Concrete Block-Int InsEAMILY ROO 9.1 16 0 10 1 161.3 ft2 0 0 0.6 0 11 S Exterior Concrete Block-Int Insul CAFE 9.1 8 0 10 1 80.7 ft2 0 0 0.6 0 _12 E Exterior Concrete Block-Int InsBEDROOM 4 9.1 12 0 8 1 97.0 ft2 0 0 0.6 0 _13 N Exterior Concrete Block- Int InsuM.TOILET 9.1 9 0 8 1 72.8 ft2 0 0 0.6 0 14 W Exterior Concrete Block-Int InsuM.TOILET 9.1 6 0 8 1 48.5 ft2 0 0 0.6 0 I _15 E Exterior Concrete Block-Int Insul BATH 2 9.1 6 0 8 1 48.5 ft2 0 0 0.6 _ 0 I 16 S Exterior Concrete Block-Int InsBEDROOM 2 9.1 11 0 8 1 88.9 ft2 0 0 0.6 0 17 W Exterior Concrete Block-Int InsBEDROOM 2 9.1 10 0 8 1 80.8 ft2 0 0 0.6 0 18 E Exterior Concrete Block-Int InsBEDROOM 3 9.1 13 0 8 1 105.1 ft2 0 0 0.6 0 19 S Exterior Concrete Block-Int InsBEDROOM 3 9.1 10 0 8 1 80.8 ft2 0 0 0.6 0 2/9/2017 2:31 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below a ()Mt Tn Wall Type Space -- PtArea o _20 S Exterior Concrete Block-Int Insul CLST 3 9.1 2 0 8. 1 16.2 ft2 0 0 0.6 0 _21 E Exterior Concrete Block--Int Insul BATH 3 9.1 6 0 8 1 48.5 112 0 0 0.6 0 22 N Garage Frame:Wood LAUNDRY 11 21 8 1 169.8 ft2 0 0 0.600000 0 23 E Garage Frame-Wood 'DINING ROO 11 7 8 1 56.6 ft2 0 0 0.600000 ,0 WINDOWS Orientation shown Is the entered, Pro osed orientation- Wall Overhang # Omt ID Frame Panes 'NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 2 Metal Low E Single Yes 0.65 025 20.0 ft2 1 ft 0 in 1 ft 4 in None None 2 W 3 Metal Low-E Single Yes 0.65 0.25 12:0 ft2 1 ft 0 in 1 ft 4 in None None 3 W 5 Metal Low-E Single Yes 0A5 0.25 12.0 ft2 1 ft 0 in 1 ft 4 in None None 4 N 6 Metal Low-E Single Yes 0.65 0.25 15.0 ft2 1 ft 0 in 1 ft 4 in None None 5 N 8 Metal Low-E Single. Yes 0.65 0.25 16.0 ft2 1 ft 0 in 1 ft 4 in None None 6 N 8 Metal Low-E Single Yes 0.65 0.26 24.0 ft2 1 ft 0 in 1 ft 4.in None None 7 N 9 'Metal Low-E Single Yes U.5 0.25 15.0 ft2 1 ft 0 in 1,ft 4 in None None 8 S 10 Metal Low-E Single Yes 0.65 0.25 61.2 ft2 1 ft 0 in 1"ft 4 in None None 9 S 11 Metal Low:E Single Yes 0.65 0.25 15.0 ft2 1 ft 0 in 1 ft 4 in None None 10 E 1'2 Metal' Low-E Single Yes 0.65 0.25 15:0 ft2 l ft 0'•in 1 ft4 in None None 11 N 13 Metal Low-E'Single Yes 035 0.25 4.0 ft2 1 ft 0 in 1.ft 4 in None None 12 E 15 Metal Low-E Single Yes 0AS 0.25 6:0 ft2 1 ft 0 in 1 ft 4 in None None 13 S 16 Metal Low-E Single! Yes 0.65, 0.25 15:0 ft2 1 ft 0 in 1 ft 41n None None 14 S 19 Metal. Low-E Single Yes 0.65 0.25 15.0 ft2 1 ft 0 in 1 ft 4 in None. None 15 E 21 Metal tow=E Single Yes 0 65 0.25 6.0 ft2 1 ft 0 in 1 ft 4 In None None GARAGE # Floor Area_ Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 441 ft2 384,ft2 28 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACM ACH:50 1 Wholehouse Proposed ACH(50) .000405 2456.7 134.87 253.64 .296 7 HEATING,SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 'i f 1 Electric Strip Heats None COP:1 27 kBtu/hr 1 sys#1 p I - 1 7t i I I � I 2/912017 2:31 PM EnergyGauge@ USA- FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 I FORM R405-2014 COOLING.SYSTEM I # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation I 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None 1 I; SOLAR HOT WATER SYSTEM f FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ! —Supply-- —Return— Air CFM 25 CFM25 HVAC# I V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool ± 1 Attic 6 185 ft2 Attic 19 ft2 Default Leakage LAUNDRY (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fahs: Coolin [[ ]]Jan [r J1 Feb ( �Mar ( A r [ Ma [X]Jun [ Jul AugX� Se ( Oct Nov [[ �Dec Heatin [X]Jan t J Feb [X] Mar Apr [ May [ ]Jun [ Jul Aug [ Sep Oct Nov [7Q Dec Venting [[ ]]Jan [ ]Feb [[XX]] Mar Apr [ May [ ]Jun [ Jul Au [ ]Se Oct X Nov [[ ]]Dec Thermostat Schedule: HERS 2006 Reference Hours l� Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 1 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 y I I 2/9/2017 2:31 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1.1 I, AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA I Project Name: DIAZ RESIDENCE Builder Name: ASSOCIATED HOMES INC. IIII Street: PALMETTO DRIVE Permit Office: S_T LUCIE COUNTY City,State,Zip: FORT PIERCE,FL, Permit Number: Owner: WILLIAM AND JENNIFER DIAZ Jurisdiction: Design Location: FL,Fort Pierce I COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope: Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. ! Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in J substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. I f! Windows, skylights and doors The space between window/doorjambs and framing and skylights and I Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside, and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. ' Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I i Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. I Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 2/9/2017 2:32 PM EnergyGauge®USA-FlaRes2014 Section R405A.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) i DISPLAY CARD i ESTIMATED ENERGY PERFORMANCE INDEX* = 91 i The lower the EnergyPerformance Index, the more efficient the home. PALMETTO DRIVE, FORT.PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=9.1 1798.90 ft2 b.Frame-Wood,Adjacent R=11.0 226.33 ft2 3. Number of units,if multiple family 1 c.N/A R= fY 4. Number of Bedrooms 4 d.NIA R= ft2 5. Is this a worst case? No 10.Calling Types Insulation Area I a.Under Attic(Vented) R=30.0 2310.00 ft 6. Conditioned floor area(ft2) 2310 b.N/A R= ft2 I c.N/A R f 11.Ducts 7. Windows- Description Area R , ft' � a. U-Factor: Sgl,U=0.65 251.26 ft2 a.Sup:Attic,Ret Attic,AH:LAUNDRY 6 185 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr. Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a:Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 23:10.00 ft2 a.Electric EF:0.98 b.WA R= ft2 b. Conservation features c.N/A R= ft2 None 16.Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building o�TE1ESTg1R Construction through the above energy saving features which will be installed (or exceeded) �, •_ = o in this home before final inspection. Otherwise, a new EPL Display Card-will be completed based on installed Code compliant features. Builder Signature: Date: I �* !� 2 Address of New Home: City/FL Zip: Z+ 3�`l`6Z, coDWf p f 4 *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM_)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For i information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/912017 2:32 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 + wrightsoft° Project Summary Job: *� Entire House B; QUICK CALCS, INC. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax 7724666796 Email:QUICKCALCS o(�AOL.COM Project • • For: DIAZ RESIDENCE,ASSOCIATED HOMES INC. PALMETTO DRIVE, FORT PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19264 Btuh Structure 20316 Btuh Ducts 7253 Btuh Ducts 10540 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26517 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 29313 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3946 Btuh Ducts 2896 Btuh Heating Coolingg Central vent 0 cfm) 0 Btuh Area(ftz) 2310 2310 Equipment latent load 6841 Btuh Volume(ft3) 21058 21058 Air changes/hour 0.32 0.16 Equipment total load 36154 Btuh Equiv.AVF(cfm) 112 56 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM Model Cond RA1642AJlNA AHRI ref Coil RH1T4821MTANJA AHRI ref 8080742 Efficiency 100 EFF Efficiency - 13.0 EER, 16 SEER Heating input 10.0 kW Sensible cooling 29400 Btuh Heating output 34121 Btuh Latent cooling 12600 Btuh Temperature rise 22 °F Total cooling 42000 Btuh Actual air flow 1400 cfm Actual air flow 1400 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 1 wrightsoft" 2017-Feb-0914:20:08 Right-Suite@ Universal 2017 17.0.08 RSU08101 Page 1 '�� E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N F�+ wrightsoft' Right-J®Worksheet Job: Entire House Date: FEB.9,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax:7724666796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 202.9 ft 42.0 ft 3 Room height 9.1 ft d 9.1 ft heat/cool 4 Room dimensions 14.0 x 18.0 ft 5 Room area 2310.0 ft2 252.0 ft2 Ty Construction U-value Or HTM Area (ft-) Load Area (ft-) Load number (Btuh/ft2°F) (Btuh/ftl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5fcs 0.083 n 2.32 1.10 386 312 725 344 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 4 0 75 59 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 30 0 563 446 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 16 0 300 238 0 0 0 0 11 2 glazing,clr outr, 0.670 n_ 18.76 14.87 _ 24 0 _ 450 357 0 0 0 0 V+/ 13A-7.5fcs 0.083 a 2.32 1.10 391 364 845 401 91 91 211 100 2 glazing,clr out;, 0.630 a 17.64 33.47 12 0 212 402 0 0 0 0 2 glazing,Of outr,_ 0.630 a 17.64 33.47 __ 15 0 265 502 0 0 0 0 13A-7.5fcs 0.083 s 2.32 1.16 566 430 999 475 127 107 250 119 2 glazing,clr outr, 0.630 s 17.64 14.69 45 45 794 661 0 0 0 0 2 glazing,clr out;, 0.630 s 17.64 14.69 20 20 353 294 20 20 353 294 2 glazing,clr out;, _ _ 0.630 s _ 17.64 _ 14.69 61 61 1080 899 0 __- 0 0 _ 0 13A-7.5fcs 0.083 w 2.32 1.10 470 -446 1035 492 164 152 353 168 2 glazing,clr outr, 0.630 w 17.64 33.47 12 0 212 402 12 0 212 402 2 glazing,clr outr, 0.630 w 17.64 33.47 12 _ 0 212 402 0 0 0 0 C_ 1613-30ad_ _ __ 0.032 0.90 1.60 2310 2310 _ - 2070 3696 252 252_ 226 403 F _ 22A-tpl_ _ _ _ 0.989 27.69 ,_ 0.00 _. .2310 , _203 5619 0 252 42 1163 0 6 c)AED excursion 0 38 Envelope loss/gain 15808 10070 2767 1523 12 a) Infiltration 3456 926 733 196 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 2 460 Appliances/other 8400 1000 Subtotal(lines 6 to 13) 19264 20316 3500 3179 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 19264 20316 3500 3179 15 Duct loads 138% 52%1 72531 10540 38% 52% 1318 1649 Total room load 26517 30856 4818 4829 Air required(cfm) 1400 1400 254 219 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Z;-4 � r w ightsuft- Right-Suite®Universal 2017 17.0.08 RSUD8101 2017-Feb-09 1:220::08 E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N g wrightsoft• Right-M Worksheet Job: Entire House Date: FEB.9,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax:7724666796 Email:QUICKCALCS AOL.COM 1 Room name WIC 1 WIC 2 2 Exposed wall 8.0 ft 0 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 5.0 x 8.0 ft 6.0 x 6.0 ft 5 Room area 40.0 ft' 36.0 ft' Ty Construction U-value Or HTM Area (ft) Load Area (ft') Load number (BtuIVW°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.Sfcs 0.083 n 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,clr out;, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 11 2 glazing,clr out;, 0.670 n 18.76 14.87 -_ 0 _ -- 0 0 0 0 0 0 0 13A-7.5fcs 0.083 a 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr out;, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,c_Ir outr, 0.630 a 17.64 _33.47 0 0 0 0 0_ 0 _0 0 2 glazing, 0.630 s 7.64 1.69 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,clr out;, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2.glazing,clr out;, 0.630 _ s 17.64 _- 14.69 _ - - 0 _ 0 0 _0 _0 _ 0 _0 _ 0 13A-7.5fcs 0.083 w 2.32 1.10 65 65 151 72 0 0 0 0 2 glazing,clr out;, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,clr out;, 0.630 w 17.64 33.47 0_ 0 0_ 0 0 0 0 0 C _._ 166-30ad _. __ 0.032 - 0.90 1.60 _ 40 _- 40 _ 36 64 _ 36 _ 36_ 32 58 F_ _-_ 22A-tpl 0.989 27.69 _ 0.00 - _- _ 40 _8 _ 222 0 36 0 0 0 6 c)AED excursion -4 1 Envelope loss/gain 408 132 32 56 12 a) Infiltration 124 33 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 532 165 32 56 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 532 165 32 56 fDuct loads 38% 52% 200 86 38% 52% 12 29 Total room load 733 251 44 86 Air required(cfm) 39 11 1 121 4 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2017-Feb-09 14:20:08 ACCK Right-Suite®Universal 2017 17.0.08 RSU08101 Page 2 E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N ra wrightsoft' Right-J®Worksheet Job: Entire House Date: FEB.9,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax:7724666796 Email:QUICKCALCS AOL.COM 1 Room name MASTER BATH OFFICE 2 Exposed wall 10.0 ft 15.0 ft 3 Room height 8.1 ft heat/cool 10.1 ft heat/cool 4 Room dimensions 1.0 x 151.5 ft 1.0 x 167.5 ft 5 Room area 151.5 ftz 167.5 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuh/ft?°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A-7.5fcs 0.083 n 2.32 1.10 0 0 0 0 ul 108 247 117 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 15 0 281 223 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 11 2 glazing,clr outr, _ _ 0.670 _ n 18.76 14.87 0 ___0 0 -0 _ 0- _ 0 0 . 0 1�/ 13A-7.5fcs 0.083 a 2.32 1.10 0 0 0 0 0 0 0 0 �L_�G 2 glazing,clr outr, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,_clr outr, 0.630 a 17.64_ 3.3.47_ __0 0 0 0 0 0 0 0 13A-7.5fcs 0.083 s 2.32 1.10 0 0 0 6 0 0 0 6 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 _ . 2 glazing,clr outr,- __- -_ _ - 0.630 s 17.64 . __14.69 .-.0_ _.- _ _0_ _ _- 0 0 _ 0 ._ -_-. 0 - 0 -0, V)/ 13A-7.5fcs 0.083 w 2.32 1.10 81 69 160 76 30 30 70 33 II�C 2 glazing,clr outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.630 w 17.64 33.47 12 0 212 402 0 0 0_ 0 C_ _ 166-30ad_ -__ _ - 0:On _ -. 0.90 1.60 _152__ _ ,1-52 _ _- _.136 __ __24-2 , 168 _168 150 _ 268_ 22A-tpl_ -- __-. 0.989 27.69 _ 0.00 _- 152 10 277 0 _- 168 15 _ .415 - -0 6 c)AED excursion 141 -15 Envelope loss/gain 785 861 1164 626 12 a) Infiltration 155 42 291 78 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 940 1403 1455 704 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 514 328 14 Subtotal 940 1403 1969 1032 T 15 Duct loads 38% 52% 354 728 38% 52% 741 535 F1Total room load 1294 2130 2710 1567 Air required(cfm) 68 97 143 71 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. ACCP. wrigt�tsoft' 2017-Feb-09 1 Right-Suite®Universal 2017 17.0.08 RSU08101 Page ae 3 E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N 9 �{a wrightsoft' Right-J®Worksheet Job: Entire House Date: FEB.9,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax 7724666796 Email:QUICKCALCS@AOL.COM 1 Room name FOYER DINING ROOM 2 Exposed wall 8.0 ft 11.0 ft 3 Room height 10.1.ft heat/cool 10.1 ft heat/cool 4 Room dimensions 8.0 x 14.0 ft 11.0 x 14.0 ft 5 Room area 112.0 ft' 154.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/f:2°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NOS Heat Cool 6 13A-75fcs 0.083 n 2.32 1.10 81 41 95 45 111 96 223 106 2 glaz ing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0 0 15 0 281 223 2 glazing,clr outr, 0.670 n 18.76 14.87 16 0 300 238 0 0 0 0 11 2 glazing,cir outr, 0.670 n_ 18.76 14.87 .__ _24 0 450 357 0 0 0 0 V+/ 13A-7.5fcs 0.083 a 2.32 1.10 0 0 0 0 0 0 0 0 L�-GG 2 glazing,clr outr, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,c_I_r outr, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 13A-7.5fcs 0.083 s 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,clr outr,- 0.630 s 17.64 _ 14.69 0 _ ___0 _ - __ 0 0 0 0 _0 0 V)I 13A-7.5fcs 0.083 w 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 C -_ 1613-30ad -- -__0.032 - 0.90 ___ 1.60 _-_ _-112 _- 112 ___ 100 179 154 154 138 246 F 22A-tpl_ 0.989_ - 27.69 0.00 112 8 222 0 154 - _ _ 11 305 _ 0 6 c)AED excursion -18 -13 Envelope loss/gain 1 1167 801 947 562 12 a) Infiltration 155 42 213 57 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1322 842 11601 619 Less extemai load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -1322 -842 514 328 14 Subtotal 0 0 1675 947 r15 Duct loads 38% 52% 0 0 38% 52% 630 491 Total room load 0 0 2305 1438 Air required(cfm) 0 0 1122 65 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACCA Wrightsoft- Right-Suite@)Universal 2017 17.0.08 RSU08101 2017-Feb-09 1:20:08 4 E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Cale=MJ8 Front Door faces: N 9 +� wrightsoft' Right-J®Worksheet Job: Entire House Date: FEB.9,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax:7724666796 Email:QUICKCALCS@\OL.COM 1 Room name FAMILYROOM KITCHEN 2 Exposed wall 16.0 ft 0 ft 3 Room height 10.1 it heat/cool 10.1 ft heat/cool 4 Room dimensions 1.0 x 358.0 ft 16.0 x 11.0 ft 5 Room area 358.0 ft2 176.0 ft' Ty Construction U-value Or HTM Area (ft-) Load Area (ft') Load number (Btuh/ftk°F) (Btuh/ft2) or perimeter (ft) (Btuh) or, perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5fcs 0.083 n 2.32 1.10 0 0 0 0 0 0 60 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 11 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 . 0 0 0_ 0 0 0 V�J 13A-7.5fcs 0.083 a 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.630 e 17.64 33.47 0 0 0 0 0 0 0 0 13A-7.5fcs 0.083 s 2.32 1.10 162 100 233 111 0 0 0 0 2 glazing,cir outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64_ 14.69 61 61 _1080 899 0 0 _ 0 0 13A-7.5fcs 0.083 w 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 C 1613-30ad _ 0.032 0.90 1.60 _ 358 _ 358 321 573 176 176 158 282 F 22A-tpl 0.989 _ - 27.69 0.00 358 16 443 0 176 0 _ 0 0 6 c)AED excursion -8 -48 Envelope loss/gain 2077 1575 158 233 12 a) Infiltration 310 83 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 19001 2000 Subtotal(lines 6 to 13) 2387 3558 158 2233 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 294 187 28 49 14 Subtotal 2680 3745 186 2282 15 Duct loads 38% 52% 1009 1943 38% 52% 70 1184 Total room load 3690 5688 255 3466 Air required(cfm) 195 258 13 157 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACCA wrightsofta Right-Suite®Universal 2017 17.0.08 RSU08101 2017-Feb-09 1Page 5 E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N 9 wrightsoft' Right-J®Worksheet Job: Entire House Date: FEB.9,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax:7724666796 Email:QUICKCALCS@40L.COM 1 Room name CAFE CLST 2 2 ,Exposed wall 8.0 ft 0 ft 3 Room height 10.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 8.0 x 10.0 ft 8.0 x 2.0 ft 5 Room area 80.0 ft2 16.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load number (Btuh/ft2 17) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5fcs 0.083 n 2.32 mo 0 0 0 0 0 0 0 0 2 glazing,cIr out,, 0,670 n 18,76 14,87 0 0 0 0 0 0 0 0 2 glazing,clr out, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 11 _ 2 glazing,clr_outr, 0.670 n_ __18.76_ _-14.87_ - _ 0 0 0 _ 0 _ 0. _ . .0___ 0 - 0 y✓ 13A-7.5fcs 0.083 a 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 13A-7.ng, 0.630 s 7.64 9.69 81 66 265 73 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 15 15 265 220 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 .2 glazing,clr outr, 0.630 s 17.64 14.69 -_._. 0 - __ 0____ _ 0 0 0-- 0 _ _- _0 - - 0 13A-7.5fcs 0.083 w 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,clr out, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 C_ 16B30ad, __ -__ _ 0.032_ - _ 0.90 1 60-_ _- _80 80 _ 72 _-0 128 16- _-__16 __._ 14 _ 26 F _ 22A-tPl_,-_- 0.989 - 27.69 0.00 _80. 8 222 - 16 - - 0 ,_ _ 0 0 -- - 6 c)AED excursion -2 1 Envelope loss/gain 711 419 14 25 12 a) Infiltration 155 42 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 250 0 Subtotal(lines 6 to 13) 866 710 14 25 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 11 19 -14 -25 14 Subtotal 876 729 0 0 15 Duct loads 138% 52% 330 378 38% 52% 0 0 Total room load 1207 1107 0 0 Air required(cfm) 64 50 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACCA wrigF�tsoft' Right-Suite@ Universal 2017 17.0.08 RSU08101 2017-Feb-09 1 Page 6 E:\Documnets\WrightsoftWAC\DIAZRESIDENCE.rup Calc=MJ8 Front Door faces: N 9 +� wrightsoft' Right-J®Worksheet Job: FEB.9,2017 Enure House QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax:7724666796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 4 CLST 4 2 Exposed wall 12.0 ft 0 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 1.0 x 139.5 ft 1.0 x 20.0 ft 5 Room area 139.5 ft2 20.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A-7.5fcs 0.083 n 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0,670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,clr out;, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 11 2 glazing,clr outr, 0.670 n 18.76 _ 14.87 0 0 0 0 0 0 0 0 V)/ 13A-7.5fcs 0.083 a 2.32 1.10 97 82 191 91 0 0 0 0 L�-GG 2 glazing,cir outr, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 a 17.64 33.47 15 0 265 502 0 0- 0 0 13 glazing, 0.630 s 7.64 1.69 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 Vb 2 glazing,_cir outr, 0.630_ s 17.64. 14.69 0 0 0 0 0 0_ 0 0 13A-7.5fcs 0.083 w 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 _ 0 0 C 16B-30ad_ _ 0.032 0.90 1.60 _ _ 14-o 140 _ _125 223 20 _ 20 _, 18 __ 32 F_ 22A-tpl_ 0.989 27.69 0.00 140 12 332 0 20 0 0 0 6 c)AED excursion -10 -1 Envelope loss/gain 913 807 18 31 12 a) Infiltration 186 50 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 750 0 Subtotal(lines 6 to 13) 1099 1836 18 31 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 17 30 -18 -31 14 Subtotal 1116 1866 0 0 15 Duct loads 38% 52% 420 968 38% 52% 0 0 Total room load 1537 2834 0 0 Air required(cfm) 81 129 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACCA Wrtghtsoft" Right-Suite@ Universal 2017 17.0.08 RSU08101 2017-Feb-09 1Page7 E:\Documnets\wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N 9 wrightsoft• Right-JO Worksheet Job: Entire House Date: FEB.9,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax:7724666796 Email:QUICKCALCS@/\OL.COM 1 Room name M.TOILET BATH 2 2 Exposed l 6.0 ft 3 Room height 8.1 ft 15.0 ft heat1cool 8.1 ft heat/cool 4 Room dimensions 9.0 x 6.0 ft 1.0 x 58.0 ft 5 Room area 54.0 ft' 58.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft-) Load number (Btuh/ft'°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5fcs 0.083 n 2.32 1.10 73 69 160 76 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 4 0 75 59 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 11 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0__ _ 0 0 0 0 0 V+/ 13A-7.5fcs 0.083 a 2.32 1.10 0 0 0 0 49 43 99 47 I�-CG 2 glazing,cir outr, 0.630 a 17.64 33.47 0 0 0 0 6 0 106 201 2 glazing,clr outr, 0.630 a 17.64 3.3.47 0 0 0 0 0 0 0 0 13A-7.5fcs 0.083 s 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr out;, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,cir out;, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,clr outr,_ 0.630 s 17.64 _ 14.69 _ 0 0 _ 0 0 0 0 0 0 W 13A-7.5fcs 0.083 w 2.32 1.10 49 49 113 54 0 0 0 0 2 glazing,cir out;, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,cir out;, 0.630 w 17.64 3.3.47 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.90 _ _ 1.60 _ 54 54 48 _ 86 58 58 52 93 F 22A-tpl _ ___ 0.989 27.69 0.00 54 .15 415 0 58 6 166 0 6 c)AED excursion -7 4 Envelope loss/gain 812 268 423 345 12 a) Infiltration 233 62 93 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1045 331 516 370 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 8 14 14 Subtotal 1045 331 524 384 15 Duct loads 38% 52% 393 172 38% 52% 197 199 Total room load 1438 502 721 583 Air required(cfm) 76 23 38 26 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACCA WrigF7t5o1Ft" 2017-Feb-09 1 Right-Suite®Universal 2017 17.0.08 RSU08101 Page 08aage8 E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N 9 wrightsoft• Right-J®Worksheet Job: Entire House Date: FEB.9,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax:7724666796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 HALL 2 Exposed wall 21.0 ft 0 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 1.0 x 148.0 ft 1.0 x 68.5 ft 5 Room area 148.0 ftz 68.5 ft' Ty Construction 1-1-value Or HTM Area (ftz) Load Area (ft-) Load number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5fcs 0.083 n 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 11 2 glazing,.clr ,outr, _ 0.670 n- 18.76 _ 14.87 0 0 ._ _ 0 0 _ _ _ 0 0 0 0 V+1 13A-7.5fcs 0.083 a 2.32 1.10 0 0 0 0 0 0 0 0 I�-GG 2 glazing,clr outr, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 _2 glazing,clr outr, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 13A-7.5fcs 0.083 s 2.32 1.10 89 74 172 82 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 15 15 265 220 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 _ 2 glazing,_clr outr, 0.630 s 17.64 14.69 _ _0 0 0 _ 0 0 . _ _ 0-- 0 0 0 TA13A-7.5fcs 0.083 w 2.32 1.10 81 81 188 89 0 0 0 0 2 glazing,clr outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,clr outr_, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 C_ _ 16B-30ad _ 0.032 - 0.90 1.60 _ 148 148 _ _ 133 237 _ 69 69 _ 61 110 F_ 22A-tpl __.. 0.989 27.69 0.00_ 148 21 582 _ 0 69 0 0 0 6 c)AED excursion -18 -2 Envelope loss/gain 1339 610 61 107 12 a) Infiltration 326 87 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 1665 1428 61 107 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 88 64 -61 -107 14 Subtotal 1753 1491 0 0 15 Duct loads 38% 52% 660 774 38% 52%1 0 0 Total room load 2413 2265 0 0 Air required(cfm) 127 1053 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACCA A,— WrightsOft- Right-Suite®Universal 2017 17.0.08 RSU08101 2017-Feb-09 1:220:0 8 8 E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJB Front Door faces: N 9 wrightsoft' RighW@ Worksheet Job: Entire House Date: FEB.9,2017 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax:7724666796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 CLST 3 2 Errposed wall 22.9 ft 2.0 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 1.0 x 134.0 ft 1.0 x 19.0 ft 5 Room area 134.0 ft2 19.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft22F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7."s 0.083 n 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 11 2 glazing,cir outr, _ 0.670 n 18.76 _ 14.87- _ 0 _ _ 0 _ 0 0 0 0 0 _ 0 yJ 13A-7.5fcs 0.083 a 2.32 1.10 105 105 245 116 0 0 0 0 I�_GG 2 glazing,clr outs, 0.630 a 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,clr out;, _ 0.630 a 17.64 33.47 0 0 0 0 0 0 _ 0 0 Vh13A-7.5fcs 0.083 s 2.32 1.1b 81 66 153 73 16 16 38 18 2 glazing,cir outr, 0.630 s 17.64 14.69 15 15 265 220 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2.glazing,clr outr, ._ 0.630 s 17.64 14.69 0 ___- 0 0 _ _ 0 _0._ 0 0 0 13A-7.5fcs 0.083 w 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,cir outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 _2 glazing,clr outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 C 16B30ad. --.0.032 0.90_ _ 1.60 134_ 134 120 214 19 19 - 17 30 F 22A-tpl_ _ 0.989 27.69 0.00 _ .134 23 635 0 _ 19 2 55 0 6 c)AED excursion -13 -1 Envelope loss/gain 1417 611 110 47 12 a) Infiltration 357 96 31 8 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 1775 1206 141 55 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 82 42 -141 -55 14 Subtotal 1856 1248 0 0 15 Duct loads 38% 52% 699 648 38% 52% 0 0 Total room load 2555 1896 0 0 Air required(cfm) 135 86 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. AGP.�`d wPIgF7tsOft" Right-Suite@ Universal 2017 17.0.08 RSU08101 2017-Feb-09 g Page 110 E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N - wrightsoft° Right-J®Worksheet Job: FEB.9,2017 Entire House QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax 7724666796 Email:QUICKCALCS ,AOL.COM 1 Room name LAUNDRY BATH 3 3 R000 e omhe height l 0 ft 6.0 8 1 ft heat/cool 8.1 ft ft heat/cool 4 Room dimensions 10.0 x 6.0 ft 11.0 x 6.0 ft 5 Room area 60.0 ft' 66.0 ft' Ty Construction U-value Or HTM Area (ft) Load Area ) Load number (BtutV t?°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter ft Btuh Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool • 6 13A-7.5fcs 0.083 n 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 11 2 glazing,clr outr, 0.670 n 18.76 14.87 0 0 0 0 0 0 0 0 13A-7.5fcs 0.083 a 2.32 1.10 0 0 0 0 49 43 99 47 2 glazing,clr outr, 0.630 e 17.64 33.47 0 0 0 0 6 0 106 201 2 glazing,clr outr, 0.630 a 17.64 33.47 0 0 0 0 0 0 _ 0 0 2 glazing, 0.630 s 7.32 4.69 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 s 17.64 14.69 0 _ 0 0 0 0 0 _ 0 0 13A-7.5fcs 0.083 w 2.32 1.10 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 w 17.64 33.47 0 0 0 0 0 0 0 0 2 glazing,clr outr, 0.630 w 17.64 33.47 0 0 0 0 0 _ 0 0 0 C 1613-30ad _ 0,032 0.90 1.60 60 60 54 96 66 66_ 69 106 F 22A-tpl __ 0.989 27.69 0.00 60 0 0 0 66 6 166 0 6 c)AED excursion -23 4 Envelope loss/gain 54 73 430 357 12 a) Infiltration 0 0 93 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1000 0 Subtotal(lines 6 to 13) 54 1073 523 382 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 1 3 0 0 14 Subtotal 55 1075 523 382 15 Duct loads 38% 52% 21 558 38% 52% 197 198 Total room load 76 1633 720 581 Air required(cfm) 4 74 38 26 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACCA vvr1ight90ft" Right-Suite(g)Universal 2017 17.0.08 RSU08101 2017-Feb-09 14:2e 108 p E:\Documnets\Wrightsoft WAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N 9 wri htsofto Duct System Summary Job: 9 Date: FEB.9,2017 Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FORT PIERCE,FL 34946 Phone:7724666799 Fax 7724666796 Email:QUICKCALCS a&OL.COM Project • • di For: DIAZ RESIDENCE,ASSOCIATED HOMES INC. PALMETTO DRIVE, FORT PIERCE, FL Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/return available pressure 0.500/0.500 in H2O 0.500/0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1400 cfm 1400 cfm Total effective length(TEL) 180 ft Supply Branch DetailTable Design Htg CIg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in). (in) Mad Ln (ft) Ln (ft) Trunk BATH 2 h 721 38 26 1.000 4.0 Ox 0 VIFx 21.7 135.0 st3 BATH 3 h 720 38 26 1.000 4.0 Ox 0 VIFx 16.6 115.0 SO BEDROOM 2 h 2413 127 103 1.000 6.0 Ox0 VIFx 25.0 135.0 st3 BEDROOM 3 h 2555 135 86 1.000 6.0 Ox0 VIFx 25.7 135.0 st3 BEDROOM4-A c 2834 81 129 1.000 6.0 Ox0 VIFx 12.2 115.0 st1 CAFE h 1207 64 50 1.000 4.0 Ox0 VIFx 30.3 135.0 st3 DINING ROOM h 2305 122 65 1.000 5.0 Ox0 VIFx 4.5 95.0 FAMILY ROOM c 5688 195 258 1.000 8.0 Ox0 VIFx 28.6 115.0 st2 KITCHEN c 3466 13 157 1.000 6.0 Ox0 VIFx 11.7 115.0 st1 LAUNDRY c 1633 4 74 1.000 4.0 Ox0 VIFx 13.4 150.0 st1 M.TOILET--A h 1438 76 .23 1.000 4.0 Ox0 VIFx 44.8 135.0 st4 MASTER BATH c 2130 68 97 1.000 5.0 Ox 0 VIFx 38.1 135.0 st4' MASTER BEDROOM-A h 2409 127 110 1.000 6.0 Ox.O VIFx 35.3 115.0 st2 MASTER BEDROOM-B h 2409 127 110 1.000 6.0 Ox0 VIFx 37.2 115.0 st2 OFFICE-A h 27.10 143 . 71 1.000 6.0 Ox0 VIFx 42.2 135.0 st4 wic 1 h 733 39 11 1.000 4.0 Ox0 VIFx 42.1 135.0 st4 WIC z c 86 2 4 1.000 4.0 Ox0 VIFx 33.2 115.0 st2 Boldlitalic values have been manually overridden �I IItSOft° 2017-Feb-09 14:20:10 W 9 Right-Suite®Universal 2017 17.0.08 RSU08101 Page 1 14CC'A E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm). FR (fpm) (in) (in) Material Trunk st3 Peak AVF 364 265 1.000 824 9.0 0 x 0 VinlFlx st1 st1 Peak AVF 501 652 1.000 830 12.0 0 x 0 VinlFlx st4 Peak AVF 326 202 1.000 738 9.0 0 x 0 VinlFlx st2 st2 Peak AVF 778 683 1.000 727 14.0 0 x 0 VinIFIX TableReturn Branch Detail Grill Htg CIg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 ox0 1400 1400 0 0 0 0 Ox 0 VIFx ^C wri 9 htsoft9 2017-Feb-0914:20:10 Right-Suite®Universal 2017 17.0.08 RSU08101 Page 2 A'Ck E:\Documnets\Wrightsoft HVAC\DIAZ RESIDENCE.rup Calc=MJ8 Front Door faces: N