Loading...
HomeMy WebLinkAboutEvaluation Report; Swinging Exterior DoorR W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 February 24, 2012 RE: Florida Product Approval FL-5891 R1 Product Evaluation Reports and Dra yings_(F .,-5891.1� To Whom It May Concern: Affirmation of Conformance to the 2010 Florida Building Code The products referenced above in this Product Approval were previously approved and found in conformance to the 2007 Florida Building Code (FBC). In addition, RW Building Consultants and Lyndon F. Schmidt. P.E. have determined that these products are also found to be in conformance to the 2010 FBC. The Product Evaluation Report(s) and Installation Drawing(s) remain unchanged. ��`�t®o�s�utrrr F SCH04;/,,r�+rsi No 43409 t. t �® STATE OF Jette, Lyndon F. Schmidt, P.E. S%pAt. � FL No. 43409 a #418111111 0 RW Building Consultants, Inc. CA No. 9813 POL�� R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product Category Sub Category Manufacturer Product Name Therma Tru Corporation TO" x 6'8" Exterior Swinging Exterior Door - -- 118 Industrial Drive _ "Smooth Star" Doors Assemblies Edgerton, OH 43517 Fiberglass Single Door Phone 419.298.1740 Inswing / Outswin "Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. for Therma Tru Corporation based on, Rule Chapter No. 9N-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 2010 Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering. This product meets missile level "D" and excludes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.4 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-5891.2 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-5891.2 for size and design pressure limitations. Supporting Documents: 1. Test Report No. ETC 01-741-10700.0 CTLA 980W 2. Drawing No. No. FL-5891.2 3. Calculations Anchoring Test Standard TAS 202-94 SSTD 12-99 Prepared by RW Building Consultants, Inc. (CA #9813) Prepared by RW Building Consultants, Inc. (CA #9813) Testing Laboratory Signed by ETC Laboratories Wendell W. Haney, P.E. Certified Testing Laboratories Ramesh Patel, P.E. Siqned & Sealed by Lyndon F. Schmidt, P.E. Siqned & Sealed by Lyndon F. Schmidt, P.E. 4. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Therma Tru Corporation is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. Lyndon F. Schmidt, P.E. FL PE No. 43409 6/21/2012 PF 863 Sheet 1 of 1 THERMAITRU 0 THERMA TRU DOORS 1 1 B INDUSTRIAL DR., EDGERTON, ❑H 43B1 7 TEL. (419)298-1740 3r0 n y L 18rr "SMOOTH STAR" FIBERGLASS SINGLE DOOR INSWING / OUTSWING "IMPACT" GENERAL NOTES 1. This product has been evaluated and is in compliance with the 2007 Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as fisted and spaced as shown on details. Anchor embedment to base material shag be beyond wall dressing or stucco. 3. When used in areas requiring Wind bome debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering. This product meets missile level "D" and excludes Wind Zone 4 as defined In ASTM E1996. 4. For 2c stud framing construction, anchoring of these units shall be the same as that shown for 2c buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEET# DESCRIWION 1 Typical elevations, design pressures & general notes 2 Door panel details 3 Horizontal cross sections 4 Vertical cross sections 5 Buck and frame anchoring - 2X buck masonry construction 6 Frame anchoring - IX buck masonry construction 7 Bill of Materials & Components 37.59" MAX. O A. FRAME WIDTH 36.(V MAX. PANEL WIDTH 19 w 0 (99 m OVERALL �7�SfGN Plt�$SURE lP$� SWING FRl1ME f aHt�r�IsroN PostTlvrw rurGAxTrr<' INSWING 37.59" x 82.19" +67.0 -67.0 OUTSWING 37.59" x 80.69" +67.0 -67.0 ON yE tlM7 �N yyCC511 m I-J ZO v' i $ nzom `2 •• a r 0 OZ E o` - z '3 m9 o-o oo = o K fi U s— N.T.S. DWG. ar: AL auc. er WWH FL-5891.2 .r 1 OF 7 Q � m c 03 O o v N N ® ® ® o= m N ) � � 1.54" l � 0.811, N = zo ILLLLGJ o ` 1' s TCR mti n 0 O 5 o N 1n rn a 1.54"0.88"0 y 0 Tr-1 Y ' A P A m m 0 n. h . . . . . . . . . . . . . ... 0 N ri z Q ;u � 0 A N Z PPRODUCT: THERMA—TRU Documenta Pmparad By: UILDIN. CONSULTANTS, INC. rr o 1 t. FIBERGLASS DOOR .o. Box 230 Valrico FL 33595 IN c Phone No.: 513.559.9197 PART OR ASSEMBLY: D - y Could. ato d A ho fe C.rtda Board of Prole U- I Enginaera No. 9H73 I-4 N = co DOOR PANEL DETAILS NO DATE BY REVISIONS Wrrndall W. E No. 54159 ® 2O�H R.W. BUILDING CONSULTANTS INC. wa ->u W,l jrL oo %r­ovi-.o.uwy, rluuo *+ 1" MIN. FROM I" MIN. FROM m p —MASONRY EDGE MASONRY EDGE 3: (TYP.) (TYP.) nz a o m w� v � x ao n C ^ V 0 � O A 7 C) n ri CI 00 V O 0 De m r�T O 0 ER 0 0 AA ® ® ® AN D ww wN ww M ITI M O O nH H= 70 70 6nfA p 10 00 n O f== :a _ �o �? a CDX z M Z � ;v m 22 a W N O O c o V rn O N p 2-1 /2" MIN. FROM M2-1/2" MIN. FROM 00 .— MASONRY EDGE MASONRY EDGE Z (TYP.) (TYP.) O.'O O N ^ y � O O Z P .. n d � A I" MIN. FROM 1"MIN. FROM ` ? -.—MASONRY EDGE MASONRY EDGE —�► (TYP.) Q PRODUCT: THERMA—'TRU Documents Prepared By. �p UILDINC CONSULTAMS, INC. FIBERGLASS DOOR Box 230 valrtco FL 33595 IW zD t/l .0. Phone No.: 813.659.9197 00 =• r0 a ? N y Florida Board of Profee tonal Engineers Certificate Of uNoriz on No. 8813 PART OR ASSEMBLY: Iv �' s r °�° HORIZONTAL CROSS SECTION S'/- O$ NO DATE BY REVISIONS wendoll W. n P.E. No. 54155 0 2008 R.W. BUILDING CONSULTANTS IND• I" MIN. FROM 1" MIN. FROM -MASONRYEDGE MASONRY EDGE m \ () (TYP.) ) 2-1 IT MIN. FROM 2-1/2" MIN. FROM o m m - - MASONRY EDGE MASONRY EDGE -�► �' 11m (TYP.) (TYP.) ° H E a a. oom e•� a a ' "•� � it z 0 x Z 0 9mm?i K i� IL umo A C w u C \ 7 PT777777T,t� o-rrrr�rr�7x, v INTERIOR EXTERIOR �o c F INTERIOR EXTERIORS m� y �1 VERTICAL CROSS SECTION /"21 VERTICAL CROSS SECTION W� d 4 Inswing configuration 4 Shown w/1 X sub -buck substituting o concrete screws for wood screws per of Section 1714.5.4.2 of the FBC o INTERIOR 3 VERTICAL CROSS SECTION 4 Inswing configuration EXTERIOR INTERIOR o. M4/2318 C ® VERTICAL CROSS SECTION D 4 Outswing configuration CNK Ery' WWH 3, DRAWING NO.: O FL-5891.2 c SHEET 4 OF 7 n — — 0 a `Q D nP• HEAD 8 MASONRY JAMBS OPENING SEE NOTE 1 to X u■T W 1 2X BUCK—\ � p BUCK ANCHORING STRIKE JAMB MASONRY OPENING FRAM 2X BUC NOTES: 1. 114" Elco Concrete screws anchoring 2x buck require a minimum 1"clearance to masonry edges, a 1-114" minimum embedment and a minimum 4" clearance to adjacent concrete screws. Substitution of equal concrete screws from a different supplier may have different edge distance and center distance requirements. Concrete screw locations at the corners may be adjusted to maintain the minimum edge distance to mortarjoints. If Concrete screw locations noted as "MAX. ON CENTER" must be adjusted to maintain the minimum edge distance to mortarjoints, additional Concrete screws may be required to ensure the maximum on center dimension is not exceeded. FRAME ANCHORING Masonry 2X buck construction HINGE DETAIL r� U Z 0 W W Z z c,=z HINGE JAMB LATCH 8 DEADSOLT DETAIL sY: AL m ar: WWH 3 NNG NO.: tt FL-5891.2 0 0 7 5 OF ] N ai 6" O zo bo Cq m MASONRY OPENING ® FRAME J < w TYP. HEAD & JAMBS $ z w f SEE NOTE 1 — O . pro 1X BUCK - STRIKE JAMB FRAME ANCHORING HINGE JAMB Masonry 1 X buck construction NOTES: SEE NOTE I 1/4" ITW concrete screws anchoring frame and/or sill require a minimum 2-1/2" clearance to masonry edges, a 1-1/4" minimum embedment and a minimum 3" clearance to adjacent concrete screws. Substitution of equal concrete screws from a different supplier may have different edge distance and center distance requirements. Concrete screw locations at the comers may be adjusted to maintain the minimum edge distance to mortar joints. If Concrete screw locations noted as "MAX. ON CENTER" must be adjusted to maintain the minimum edge distance to mortar joints, additional Concrete screws may be required to ensure the maximum on center dimension is not exceeded. 2. 3/16"ITW concrete screws anchoring frame and/or sill require a minimum 2-5/8" clearance to masonry edges, a 1-1/4" minimum embedment and a minimum 2-1/4" clearance to adjacent concrete screws unless otherwise noted by concrete screw manufacturer. LATCH 8 DEADBOLT DETAIL HINGE DETAIL SEE NOTE 2 SEE NOTE 2 M N.T.S. BY. AL BY.- WWH NONG NO.: F1-5891.2 i T 6 OF % k BILL OF MATERIALS ITEM DESCRIPTION MATERIAL A 1 X BUCK SG >= 0.55 WOOD B 2X BUCK SG >= 0.55 WOOD C MAX. 1 /4" SHIM SPACE WOOD D 1/4" X 2-3/4'PFH ELCO CONCRETE SCREW STEEL E MASONRY - 3,192 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE G 3/16" X 3-1/4" PFH ITW CONCRETE SCREW STEEL H 1 /4" x 3-1 /4" PFH ITW CONCRETE SCREW STEEL J 1/4" X 3-3/4" PFH ITW CONCRETE SCREW STEEL K #8 X 2-1/2" PFH WOOD SCREW STEEL L #10 X 2" PFH WOOD SCREW STEEL 7 SHORT REACH COMPRESSION WEATHER-STRIP THERMA-TRU FOAM 8 LONG REACH COMPRESSION WEATHER-STRIP THERMA-TRU FOAM 9 4" X 4" HINGE .097' THK. THERMA-TRU STEEL 10 #10 X 3/4" PFH WOOD SCREW HINGE TO FRAME STEEL 17 KWIKSET TITAN 700 SERIES PASSAGE LOCK STEEL 18 LOW PROFILE OUTSWING BUMP FACE THRESHOLD THERMA-TRU .050" WALL AL. ALUM./WOOD 19 HEADER JAMB 4.656" X 1.25" THERMA-TRU, PINE WOOD 20 SIDE JAMB 4.656" X 1.25" THERMA-TRU WOOD 21 KWIKSET TITAN 700 SERIES DEADBOLT STEEL 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT PLATE STEEL 32 DOOR BOTTOM SWEEP PVC 33 SELF ADJUSTING INSWING SADDLE THRESHOLD .45" WALL AL. - .080" WALL VINYL ALUM.COMP. 40 FIBERGLASS DOOR PANEL - SMOOTH STAR 41 FC/SS DOOR SKIN .070" MIN. THK. FIBERGLASS BY THERMA-TRU WITH YIELD STRENGTH Fy (MIN.) = 6,000 PSI SMC 42 TOP RAIL COMPOSITE 43 LATCH STILE LVL WOOD 44 HINGE STILE WOOD 45 BOTTOM RAIL COMPOSITE 46 POLYURETHANE FOAM CORE - BASF 1.9 LBS. DENSITY FOAM 47 LOCK BLOCK REINFORCEMENT WOOD � mem Z (1�n �— 4.56" y� GG 3 A T J 00 q O N>Y N d N — Z p m S- �i a dCC I 5 o= oa E m c .26 3 9 �gorg a da m�° o HEAD 8 SIDE ; 19 20 Jamb v° ^' or R K iiU I c 0 � �!uj 0 c m m WU a 00 I � 4.6Z' j o m (. 1 LOW PROFILE OUTSWING BUMP FACE a a 5.75" ►{ o I 1 �ZSElF ADJUSTING SADDLE THRESHOLD owc. er: AL air. er: 1WH FL-5891.2 T 7 of 7