HomeMy WebLinkAboutInsulation Installation Certificate02/06/2015 15:28 7724626443 SLC INSPECTIONS PAGE 01/01
f
Planning &Development Services
Building & Code Regulation Department - _-
i 2300 Virginia Ave
Fort pierce, FL 34982 l/�139;n. : �®
772-462-2165 Fax 462-6443 --N
Name: I a)6&j
Permit #: 09 — (
Lot: Z - Block:
3
INSULATION INSTALLA-aON CERTIFICATE
Address: V6 IOO t-
Subdivision: !ZA?- roA CscsN-rJ?-`y' f:! -rn-TC—'S
The undersigned hereby certifies that insulation as been G S ��U t the above described property as follows:
1. Exterior CBS walls have been insulated with .C.:........•...:.?k... () Spray on cellulose
which thickness, according to the manufacturer: Fi-Foil, () Fiberglass blankets
(Density N/A) will yield an "R" value of 4.1. () Aluminum Foil
0ther3j9 3c)4zb
Exterior frame wall have been Insulated with kNIR! .....
To a thickness of 6.25 inches, which thickness, according to
the manufacturer, Certain Teed, (Density N/A) will yield an
1IR" value of 19.
2. Ceilings - Level - have been insulated with .. Q115-1tr_..._. •.
to a thickness of 10.0 inches, which thickness, according to
the manuf�r, Certain Teed, (Density N/A) will yield an
"R" value, f 3d.
Ceilings - Cathedral - have been insulated with ...................
to a thickness of 10.0 inches, which thickness, according to
the manufacturer, Certain Teed, Density (N/A) will yield an
"R" value of 90.
3. Interior knee walls have been insulated with A,' �Af�F.....
to a thickness of 16.0 inches, which thickness, according to
the manufacturer, Certain Teed, (Density N/A) will yield an
"R" value of 30,
( ) Spray on cellulose
MFlberglass blankets
/() Aluminum Foil
() Other
Fiberglass blanker
�) Fiberglass loose till
() Aluminum Poll
() Other Cellulose SAB
() Fiberglass blankets
()Fiberglass loose fill
() Aluminum Foil
() Other Cellulose SAB
Fiberglass blankets
Polyurethane
() Spray on cellulose
() Other
4. Garage partition vialts of nditioned living areas have been blankets
insulated with .....J�l�it.................................................... �Hberglass
Spray on cellulose
to a thickness of 6.25 inches, which thickness, according to the () Polyurethane
manufacturer, Certain Teed, (Density N/A) will yield an () Other
"R" value of 19.
MULTI -FAMILY, RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating different tenants shall be insulated as
follows - Frame/Metal stud walls R-11 (Min); CBS or Concrete walls R-3 (Min) by Energy Code requirements. See Energy Code
Rev.1/87, paragraph 903.2(b), on pages 9-17, latest edition. These "minimum levels of insulation" are not Included the Energy
Calculations, but shall be installed in the field.
NOTE: Densities of sprayed on, loose fill, or any other composed -on site Insulation shall bete PCF (lb/tl:3) average of three (3)
"DRY SAMPLES" of actual Installation.
Print Name of Insulatio Contractor
Z09
'Pertification Nu
Notary Public
°�Mr • , BARBRA A. GOOpMM
* * MYCOM1111SSION # FF 101341
EXPIRES: March 12, 2018
'or Ki%t' Braided Thro Budget Nokry' e;ke$
Date
of Msu),Alon Contractor