HomeMy WebLinkAboutProduct Approval; Metal RoofingL/ EVALUATION REPORT OF UNION CORRUGATING COMPANY `26 GA. ADVANTAGE-LOK II' FLORIDA PRODUCT APPROVAL FL 7271.5-R2 ROOFING METAL=ROOFING Prepared For: Union Corrugating Company P. O. Box 229 Fayetteville, NC 28302 Telephone: (910) 483-0479 Fax: (910) 483-8897 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) Report No. C1805-13 Date: 11.30.11 ,%%1111111!! SocKkIN�q�"i,,� E N No.62240 �a STATE OF P4O�SOO „�... o. .... FL 7271.5-R2 C1805-13 11.30.11 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: Advantage-Lok II Panel Panel Description: Max. 16" wide coverage with 1" high ribs Materials: Minimum 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min 15/32" thick plywood for new and existing constructions. Designed and installed as per FBC 2010. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. at plywood field and edges Underlayment: Minimum underlayment as per FBC 2010 Section 1507.4.5 Slope: 1/2:12 or greater in accordance with FBC 2010 Section 1507.4.2 Design Uplift Pressure: 59.4 psf @ fastener spacing of 6" o.c. in 15/32" thick plywood (Factor of Safety = 2) 97.5 psf @ fastener spacing of 6" o.c. in 15/32" thick plywood with 3/16" diameter bead sealant in panel seam 107.9 psf @ fastener spacing of 4" o.c. in 19/32" thick plywood with 3/16" diameter bead sealant in panel seam Panel Attachment: At panel seam #10-12 x 1" long A -point pancake head screws At panel ends 49-15 x 1.5" wood screw with washer — 4 per panel width At panel sides #9-15 x 1.5" wood screw with washer. @ 12" o.c. Seam Sealant: Sikaflex-201 Sealant Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2010 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2010 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2010 Section 1505 and current FL 7271.5-R2 r C 1805-13 11.30.11 Page 3 of 3 approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T185-06, Reporting Date 7/25/06 PANEL FASTENER SEE DETAIL 1 & 2 PANEL OVERLAP SPACING PER ALLOWABLE ROOF PANEL I —THIS SHEET WIND LOAD TABLE n u n V V 8d x 2.5" LONG RING SHANK NAIL u UNDERLAYMENT SHALL BE INSTALLED OR #8 x 2" LONG WOOD SCREWS AS PER MANUFACTURER'S INSTALLATION SPACED ® 6" O.C. IN THE FIELD & GUIDELINES AT PLYWOOD EDGES MIN 26 GA. PANEL UNDERLAYMENT MIN 26 GA. PANEL UNDERLAYMENT MIN. LA_ WVVU KAPICK/JVIJ1/ TRUSS AT MAX. 24' O.C. TYPICAL PANEL INSTALLATION X—SECTION #10-12 X 1" PAN HEAD WOOD FASTENER PLYWOOD q DETAIL 1 15/32" THICK (MIN.) FIELD ZONE SIKAFLEX 201 SEALANT 3/16" BEAD #10-12 AN HEAD WOOD FASTENER PLYWOOD (SEE PRESSURE DETAIL 2 TABLE FOR THICKNESS) PERIMETER & CORNER ZONE ALLOWABLE UPLIFT PRESSURE ZONE PANEL SIDELAP MINIMUM SEAM PRESSURE FASTENER PLYWOOD SEALANT (pSF) SPACING THICKNESS DIAMETER ALONG RIB FIELD 6" 15/32" NONE 59.4 PERIMETER 6" 15/32" 3/16" 97.5 & CORNER 1 PERIMETER 4" 19/32" 3/16" 107.9 & CORNER U o M Z �Nm F I-nc� Q �ZN f=S ZLjM K Y_,00 J v ui�to z o} u GENERAL NOTES: BEEN DESIGNED IN ACCORDANCE WITH THE 9� 1. ARCHITECTURAL ROOF PANEL HAS FLORIDA BUILDING CODE (FBC). 2. ALL ROOF PANELS ARE SHALL BE 26 GA. EFFECTIVE COVERING WIDTH OFy NR OF PANEL = 16". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 8 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN 4 WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE. a 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA o BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM z� REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 4Z 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS �a REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS: 1 OF 1