Loading...
HomeMy WebLinkAboutProduct Approval; Mullions WindowsFlorida Building Code Online "ivr d 3 Dery � L`+i ne1rr Busines (al� r f se P o es Regulation off t DBPR N0IF ABoUT DBPR DBPR 0MS10AS CONTACT DBPAj BOS Home Log In User Registration Hat Topics Submit Surcharge Stats & Fads %P Product Approval USER: Public User Mw 11 s Product Aooroval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance .Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards http://www.floridabuilding-org/pr/pr_apP- FL15353 New 2010 Validated ;• . r— ---711 MI, Windows and�_D_oots 650 West Market Street Gratz, PA 17030 (717) 365-3300 Ext 2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Windows MuNions Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Luis R Lomas, PE PE-62514 Architectural Testing, Inc. 12/31/2015 Steven M. Urich, PE Validation Checklist - Hardcopy Received FLIS353 RO COI FLCOI•odf 5/1/2012 Flotida Building Code Online r Certified By Page 2 of 5 Sections from the Code 1715.5.5 Product Approval Method Method 2 Option B Date Submitted 03/16/2012 Date Validated 04/23/2012 Summary of Products Model, Number or Name Description 5650 Self Stack Horizontal Aluminum Mullion FAved Installation Instructions FL15353 kO I1 SECT5650 Self Stack Sill 08-01457.Ddr use in HVHZ: No use outside HVHZ: Yes Ver Luis Lom , PE -62514pstant: Yes ted by: d P Yes Design Pressure: N/A " Other: Max single window size: 52-1/8' x 84 . Max Evaluation Reports FL15353 RO AE Evaluation SECT5650 Horizontal mullion span: 104-1/4". 512081.pdf Created by Independent Third Party: Yes 205353 2x 57A64" Horizontal Aluminum Mullion Installation Instructions FL15353 RO II SECT5764 Horizontal OS-01448.pdf Limits of Use Approved for use in HVHZ: No A robed for useroutside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Third Party: Yes mpg starer es Created by Independent ,Res Design Pressure: N/A Evaluation Reports FL15353 RO AE Evaluation SECT5764 Horizontal Other: Max single window size: 52-1/8" x 84". Max mullion span: 52-1/8". 512072.odf Created by Independent Third Party: Yes 15353.3 5764 Vertical Aluminum Mullion Limits of Use Installation Instructions FL15353 RO II SECT5764 Vertical 08-01439.pdf Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Impact Resistant: Yes Design Pressure: N/A Evaluation Reports FL15353 RO AE Evaluation SECT5764 Vertical Other: Max single window size: 52-1/8" x 84". Max 512063.pdf' mullion span: 83" Created by Independent Third Party: Yes Horizontal Aluminum Mullion 15353.4 5765 Limits of Use Installation Instructions RO II SECT5765 Horizontal 08-01449.pdf Approved for use in HVHZ: No Approved for use outside HVHZ: Yes IFL15353 Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Impact Resistant: Yes Design Pressure: N/A Evalluation Reports FL15353 RO AE 512073.odf Other: Max single window size: 52-1/8" x 84". Max Created by Independent Third Party: Yes mullion span: 104-1/4"' 15353.5 15765 Vertical Aluminum Mullion Installation Instructions FL15353 RO II SECT5765 Vertical 08-01440.odf Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Impact Resistant: Yes Design Pressure: N/A Evaluation Reports FL15353 RO AE Evaluation SECT5765 Vertical Other: Max single window size: 52-1/8" x 84". Max mullion span: 83" 512064.pdf Created by Independent Third Party: Yes i 15353.6 5766A Limits of Use Ivertical Aluminum Mullion lInstaillation Instructions http://www.floridabuilding.org/p 5/1/2012 Florida Building Code Online Page 3 of 5 Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A other: Max single window size: 52-1/8" x 84" nullion span: 83". 1.5353.7 15767 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84" mullion span: 104-1/4". Max IFL15353 RO II SECT5766A Vertical 08-01441.1)df Verified By: -Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL15353 RO AE Evaluation SECT5766A Vertical Created by Independent Third Party: Yes Horizontal Aluminum Mullion Installation Instructions FL15353 RO II SECT5767 Horizontal 08-01450.odf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports Max FL15353 RO AE Evaluation SECT5767 Horizontal 1.5353.8 ICM-18514 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max mullion length - 83". 5353.9 18520 _imits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size - 52-1/8" x 84" mullion span - 104-1/4" L5353.10 ICM-18523 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size - 52-1/8" x 84" mullion span - 104-1/4''. Created by Independent Third Pa : Yes ✓ertical Aluminum Mullion Installation Instructions FL15353 RO II CM-18514 Vertical 08-01442.odf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes ` Evaluation Reports FL15353 RO AE Evaluation CM-18514 Vertical Created by Independent Third Horizontal Aluminum Mullion Installation Instructions FL15353 RO II CM-18520 Horizontal 08-01451.2df Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports Max FL15353 RO AE Evaluation CM-18520 Horizontal Created by Independent Third Party: Yes Aluminum Mullion Installation Instructions FL15353 RO II CM-18523 Self Stack Sill 08-01452.odf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports Max FL15353 RO AE Evaluation CM-18523 Horizontal L5353.11 1CM-18531 emits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistants Yes Design Pressure: N/A other: Max single window size: 52-1/8" x 84".-Max mullion span - 83" L5353.12 ICM-18532 .imits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size - 52-1/8" x 84" mullion span - 104-1/4" Created by Independent Third Party: Yes Aluminum Mullion Installation Instructions FL15353 RO II CM-18531 Vertical 08-01443.odf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes evaluation Reports FL15353 RO AE Evaluation CM-i8531 Vertical Created by Independent Third Party: Yes Horizontal Aluminum Mullion installation Instructions FL15353 RO II CM-18532 Horizontal 08-Oi453.odf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports Max FL15353 RO AE Evaluation CM-18532 Horizontal Created by Independent Third Party: Yes 15353.13 CM-18533 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 RO II CM-18533 Vertical 08-01444.pdf http://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtH8572gvdWISXrzuhnF,tBQFZP... 5/1/2012 Florida. Building Code Online Page 4 of 5 Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max nullion span: 83" �5353.14 ICM-18534 .1mits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: NIA Other: Max single window size: 52-1/8" x 84". Max nullion span: 104-1/4". Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL15353 RO AE Evaluation CM-18533 Vertical Third Party: Yes Aluminum Mullion Installation Instructions FL15353 RO II CM-18534 Horizontal 08-01454.pdf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL15353 RO AE Evaluation CM-18534 Horizontal Created by Independent Third Party: Yes 15353.15 M-1926 fHorizontal Aluminum Mullion IV Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max Tiullion span: 104-1/4" Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max nullion span: 83" 5353.17 M-1948 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max rnuilinn span: 83" 1.5353.18 IM-2302 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes impact Resistant: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max mullion span: 104-1/4". .imits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant Yes Design Pressure: N/A Outer: Max single window size: 52-1/8" x 84". Max nullion scan: 83" Installation Instructions FL15353 RO II M-1926 Horizontal 08-01455.pdf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL15353 RO AE Evaluation M-1926 Horizontal Created by Independent Third Party: Yes Mullion Installation Instructions FL15353 RO II M-1926 Vertical 08-01445.pdf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: Yes fertical Aluminum Mullion rnstailation Instructions FL15353 RO II M-1948 Vertical 08-01446.3df Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports iorizontal Aluminum Mullion Installation Instructions FL15353 RO II M-2302 Horizontal 08-01456.pdf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL15353 RO AE Evaluation M-2302 Horizontal Created by Independent Third Party: Yes iertical Aluminum Mullion Installation instructions FL15353 RO II M-2302 Vertical 08-01447.pdf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Back Next Contact Us :: 1940 North Monroe Street Tallahassee EL 32399 Phone• 850-487-1824 http://Www.floridabuilding.orglprlpr_app dtl.aspx?param=wGEVXQwtDgtH8572gvdWlSXrzuhnEtBQFZp... 5/1/2012 11 L. Roberto Lomas P.E. Engineering Evaluation Report 1432 Woodford Rd. Lewisville, NC 27023 336-945-9695 diomas@ldomaspe.com Manufacturer. MI Windows and Doors, Inc. 650 West Market St Gratz, Pennsylvania 17030 Product Line: CM-18531 - Vertical Mullion Report No.: 612067 Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Community Affairs for Statewide Acceptance per Rule 9N-3.005 method 1(d). The product listed herein complies with requirements of the Florida Building Code, Building section 1715.5.5 7 Supponrng Technical Documentation: 1. Approval document: drawing number 08-01443, titled CM-18531 - Vertical Mullion, prepared, signed and sealed by Luis Roberto Lomas P.E 2. Mullion analysis report No. 512067-1 prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: refer to design pressure charts in approval document. Maximum single window unit size: 52 1/8° x 84° Window units attached to mullion must have their own separate approval. • This product is not rated to be used in the HVHZ. This product is impact resistant and does not require impact protection in Wind -Rome Debris Regions, up to Wind Zone 3. • Design pressure of mulled units shall be controlled by the lesser design pressure of the assembly components; mullion or individual units. • All windows attached to mullion must be manufactured by MI Windows and Doors, Inc. Installation: Mullion must be installed in strict accordance with installation instructions document 08-01443. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). 1 of 1 0 4 o =�9�;%� AT F ���'�'F•:�Z OR10P.W�� 0?���� Luis R. Lomas, P.E. FL No.: 62514 03/07/2012