Product Aooroval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance .Method
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
http://www.floridabuilding-org/pr/pr_apP-
FL15353
New
2010
Validated
;• . r— ---711
MI, Windows and�_D_oots
650 West Market Street
Gratz, PA 17030
(717) 365-3300 Ext 2560
bsitlinger@miwd.com
Brent Sitlinger
bsitlinger@miwd.com
Windows
MuNions
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Luis R Lomas, PE
PE-62514
Architectural Testing, Inc.
12/31/2015
Steven M. Urich, PE
Validation Checklist - Hardcopy Received
FLIS353 RO COI FLCOI•odf
5/1/2012
Flotida Building Code Online
r
Certified By
Page 2 of 5
Sections from the Code
1715.5.5
Product Approval Method Method 2 Option B
Date Submitted 03/16/2012
Date Validated 04/23/2012
Summary of Products
Model, Number or Name
Description
5650 Self Stack
Horizontal Aluminum Mullion
FAved
Installation Instructions
FL15353 kO I1 SECT5650 Self Stack Sill 08-01457.Ddr
use in HVHZ: No
use outside HVHZ: Yes
Ver Luis Lom , PE
-62514pstant:
Yes
ted by: d P Yes
Design Pressure: N/A "
Other: Max single window size: 52-1/8' x 84 . Max
Evaluation Reports
FL15353 RO AE Evaluation SECT5650 Horizontal
mullion span: 104-1/4".
512081.pdf
Created by Independent Third Party: Yes
205353 2x 57A64"
Horizontal Aluminum Mullion
Installation Instructions
FL15353 RO II SECT5764 Horizontal OS-01448.pdf
Limits of Use
Approved for use in HVHZ: No
A robed for useroutside HVHZ: Yes
Verified By: Luis R Lomas, PE PE-62514
Third Party: Yes
mpg starer es
Created by Independent
,Res
Design Pressure: N/A
Evaluation Reports
FL15353 RO AE Evaluation SECT5764 Horizontal
Other: Max single window size: 52-1/8" x 84". Max
mullion span: 52-1/8".
512072.odf
Created by Independent Third Party: Yes
15353.3 5764
Vertical Aluminum Mullion
Limits of Use
Installation Instructions
FL15353 RO II SECT5764 Vertical 08-01439.pdf
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Impact Resistant: Yes
Design Pressure: N/A
Evaluation Reports
FL15353 RO AE Evaluation SECT5764 Vertical
Other: Max single window size: 52-1/8" x 84". Max
512063.pdf'
mullion span: 83"
Created by Independent Third Party: Yes
Horizontal Aluminum Mullion
15353.4 5765
Limits of Use
Installation Instructions
RO II SECT5765 Horizontal 08-01449.pdf
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
IFL15353
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Impact Resistant: Yes
Design Pressure: N/A
Evalluation Reports
FL15353 RO AE 512073.odf
Other: Max single window size: 52-1/8" x 84". Max
Created by Independent Third Party: Yes
mullion span: 104-1/4"'
15353.5 15765
Vertical Aluminum Mullion
Installation Instructions
FL15353 RO II SECT5765 Vertical 08-01440.odf
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Impact Resistant: Yes
Design Pressure: N/A
Evaluation Reports
FL15353 RO AE Evaluation SECT5765 Vertical
Other: Max single window size: 52-1/8" x 84". Max
mullion span: 83"
512064.pdf
Created by Independent Third Party: Yes
i
15353.6 5766A
Limits of Use
Ivertical Aluminum Mullion
lInstaillation Instructions
http://www.floridabuilding.org/p
5/1/2012
Florida Building Code Online
Page 3 of 5
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
other: Max single window size: 52-1/8" x 84"
nullion span: 83".
1.5353.7 15767
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Max single window size: 52-1/8" x 84"
mullion span: 104-1/4".
Max IFL15353 RO II SECT5766A Vertical 08-01441.1)df
Verified By: -Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL15353 RO AE Evaluation SECT5766A Vertical
Created by Independent Third Party: Yes
Horizontal Aluminum Mullion
Installation Instructions
FL15353 RO II SECT5767 Horizontal 08-01450.odf
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
Max FL15353 RO AE Evaluation SECT5767 Horizontal
1.5353.8 ICM-18514
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Max single window size: 52-1/8" x 84". Max
mullion length - 83".
5353.9
18520
_imits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Max single window size - 52-1/8" x 84"
mullion span - 104-1/4"
L5353.10 ICM-18523
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Max single window size - 52-1/8" x 84"
mullion span - 104-1/4''.
Created by Independent Third Pa : Yes
✓ertical Aluminum Mullion
Installation Instructions
FL15353 RO II CM-18514 Vertical 08-01442.odf
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes `
Evaluation Reports
FL15353 RO AE Evaluation CM-18514 Vertical
Created by Independent Third
Horizontal Aluminum Mullion
Installation Instructions
FL15353 RO II CM-18520 Horizontal 08-01451.2df
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
Max FL15353 RO AE Evaluation CM-18520 Horizontal
Created by Independent Third Party: Yes
Aluminum Mullion
Installation Instructions
FL15353 RO II CM-18523 Self Stack Sill 08-01452.odf
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
Max FL15353 RO AE Evaluation CM-18523 Horizontal
L5353.11 1CM-18531
emits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistants Yes
Design Pressure: N/A
other: Max single window size: 52-1/8" x 84".-Max
mullion span - 83"
L5353.12 ICM-18532
.imits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Max single window size - 52-1/8" x 84"
mullion span - 104-1/4"
Created by Independent Third Party: Yes
Aluminum Mullion
Installation Instructions
FL15353 RO II CM-18531 Vertical 08-01443.odf
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
evaluation Reports
FL15353 RO AE Evaluation CM-i8531 Vertical
Created by Independent Third Party: Yes
Horizontal Aluminum Mullion
installation Instructions
FL15353 RO II CM-18532 Horizontal 08-Oi453.odf
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
Max FL15353 RO AE Evaluation CM-18532 Horizontal
Created by Independent Third Party: Yes
15353.13 CM-18533 Vertical Aluminum Mullion
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15353 RO II CM-18533 Vertical 08-01444.pdf
http://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtH8572gvdWISXrzuhnF,tBQFZP... 5/1/2012
Florida. Building Code Online
Page 4 of 5
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Max single window size: 52-1/8" x 84". Max
nullion span: 83"
�5353.14 ICM-18534
.1mits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: NIA
Other: Max single window size: 52-1/8" x 84". Max
nullion span: 104-1/4".
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL15353 RO AE Evaluation CM-18533 Vertical
Third Party: Yes
Aluminum Mullion
Installation Instructions
FL15353 RO II CM-18534 Horizontal 08-01454.pdf
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL15353 RO AE Evaluation CM-18534 Horizontal
Created by Independent Third Party: Yes
15353.15 M-1926 fHorizontal Aluminum Mullion IV
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Max single window size: 52-1/8" x 84". Max
Tiullion span: 104-1/4"
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Max single window size: 52-1/8" x 84". Max
nullion span: 83"
5353.17 M-1948
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Max single window size: 52-1/8" x 84". Max
rnuilinn span: 83"
1.5353.18 IM-2302
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
impact Resistant: Yes
Design Pressure: N/A
Other: Max single window size: 52-1/8" x 84". Max
mullion span: 104-1/4".
.imits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant Yes
Design Pressure: N/A
Outer: Max single window size: 52-1/8" x 84". Max
nullion scan: 83"
Installation Instructions
FL15353 RO II M-1926 Horizontal 08-01455.pdf
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL15353 RO AE Evaluation M-1926 Horizontal
Created by Independent Third Party: Yes
Mullion
Installation Instructions
FL15353 RO II M-1926 Vertical 08-01445.pdf
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
Created by Independent Third Party: Yes
fertical Aluminum Mullion
rnstailation Instructions
FL15353 RO II M-1948 Vertical 08-01446.3df
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
iorizontal Aluminum Mullion
Installation Instructions
FL15353 RO II M-2302 Horizontal 08-01456.pdf
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL15353 RO AE Evaluation M-2302 Horizontal
Created by Independent Third Party: Yes
iertical Aluminum Mullion
Installation instructions
FL15353 RO II M-2302 Vertical 08-01447.pdf
Verified By: Luis R Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
Created by Independent Third
Back Next
Contact Us :: 1940 North Monroe Street Tallahassee EL 32399 Phone• 850-487-1824
http://Www.floridabuilding.orglprlpr_app dtl.aspx?param=wGEVXQwtDgtH8572gvdWlSXrzuhnEtBQFZp... 5/1/2012
11
L. Roberto Lomas P.E. Engineering Evaluation Report
1432 Woodford Rd.
Lewisville, NC 27023
336-945-9695
diomas@ldomaspe.com
Manufacturer. MI Windows and Doors, Inc.
650 West Market St
Gratz, Pennsylvania 17030
Product Line: CM-18531 - Vertical Mullion
Report No.: 612067
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Community Affairs for Statewide Acceptance per Rule 9N-3.005 method 1(d). The product listed herein complies with
requirements of the Florida Building Code, Building section 1715.5.5 7
Supponrng Technical Documentation:
1. Approval document: drawing number 08-01443, titled CM-18531 - Vertical Mullion, prepared, signed and
sealed by Luis Roberto Lomas P.E
2. Mullion analysis report No. 512067-1 prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: refer to design pressure charts in approval document.
Maximum single window unit size: 52 1/8° x 84°
Window units attached to mullion must have their own separate approval.
• This product is not rated to be used in the HVHZ.
This product is impact resistant and does not require impact protection in Wind -Rome Debris Regions, up to
Wind Zone 3.
• Design pressure of mulled units shall be controlled by the lesser design pressure of the assembly
components; mullion or individual units.
• All windows attached to mullion must be manufactured by MI Windows and Doors, Inc.
Installation:
Mullion must be installed in strict accordance with installation instructions document 08-01443.
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other
entity involved in the approval process of the listed product(s).
1 of 1
0
4 o =�9�;%�
AT F
���'�'F•:�Z OR10P.W��
0?����
Luis R. Lomas, P.E.
FL No.: 62514
03/07/2012