HomeMy WebLinkAboutAPPROVED FL 5V 26GA_12251/29/2021 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvFGYZsjrZFR%2bP9kYGhInRHUPuiAxDRkQtoa%2fGVEztq%2bg%3d%3d 1/2
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL17679-R6
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Drexel Metals, Inc.
Address/Phone/Email 204 Railroad Drive
Ivyland, PA 18974
(502) 303-1511
jshumate@drexmet.com
Authorized Signature Jason Shumate
jshumate@drexmet.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Zachary R. Priest
Florida License PE-74021
Quality Assurance Entity Architectural Testing, Inc., an Intertek Company
Quality Assurance Contract Expiration Date 12/31/2025
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL17679_R6_COI_DRX15002.6 2020 FBC Eval Metal Roofing HVHZ final.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM B 117 2016
ASTM G 155 2013
TAS 100 1995
TAS 110 2000
TAS 125 2003
Equivalence of Product Standards
Certified By
Sections from the Code
1/29/2021 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvFGYZsjrZFR%2bP9kYGhInRHUPuiAxDRkQtoa%2fGVEztq%2bg%3d%3d 2/2
Product Approval Method Method 1 Option D
Date Submitted 08/09/2020
Date Validated 08/10/2020
Date Pending FBC Approval 08/20/2020
Date Approved 10/13/2020
Summary of Products
FL #Model, Number or Name Description
17679.1 Drexel Metal Roofing Systems DMC 100NS, DMC 150SS, DMC 175S, DMC 200S, DMC 5V
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: +0/-180
Other: See evaluation report for limits of use.
Installation Instructions
FL17679_R6_II_DRX15002.6 2020 FBC Eval Metal Roofing
HVHZ final.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL17679_R6_AE_DRX15002.6 2020 FBC Eval Metal Roofing
HVHZ final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
a CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 1 of 4 Page 1 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020)
Manufacturer: DREXEL METALS, INC. Issued August 9, 2020
1234 Gardiner Lane
Louisville, KY 40213
(502) 716-7143
www.drexmet.com
Manufacturing: Drexel Metals Association of Regional Manufacturers (DM-ARM)
Quality Assurance: Architectural Testing, Inc., An Intertek Company (QUA1844)
SCOPE
Category: Roofing
Subcategory: Metal Roofing
Code Edition: Florida Building Code, 7th Edition (2020) High-Velocity Hurricane Zones (HVHZ)
Code Sections: 1518.9.1, 1523.1.1, 1523.6.5, 1523.6.5.2.4, 1523.6.5.2.4.1
Properties: Wind Resistance
REFERENCES
Entity Report No. Standard Year
Architectural Testing (TST1558) 56840.02-122-18 TAS 100 1995
Architectural Testing (TST1558) 56842.02-122-18 TAS 100 1995
Architectural Testing (TST1558) 58461.01-122-44 TAS 125 2003
Architectural Testing (TST1558) 58641.02-122-44 TAS 100 1995
Architectural Testing (TST1527) H3245.01-450-18 TAS 125 2003
Architectural Testing (TST1527) H3245.02-450-18 TAS 100 1995
Architectural Testing (TST1527) H9058.02-450-18 TAS 125 2003
Architectural Testing (TST1527) H9058.01-450-18 TAS 125 2003
Architectural Testing (TST1527) H9058.03-450-18 TAS 100 1995
Hurricane Test Laboratory (TST1527) 0287-0209-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0308-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0311-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0312-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0313-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0512-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0706-07 TAS 125 2003
PRI Construction Materials Technologies (TST5878) VLS-005-02-01 ASTM B 117
TAS 110
2016
2000
PRI Construction Materials Technologies (TST5878) VLS-004-02-01 ASTM G 155
TAS 110
2013
2000
PRI Construction Materials Technologies (TST5878) DMC-002-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) DMC-004-02-01 TAS 125 2003
PRI Construction Materials Technologies (TST5878) DMC-005-02-01 TAS 125 2003
PRI Construction Materials Technologies (TST5878) DMC-006-02-01 TAS 125 2003
PRI Construction Materials Technologies (TST5878) DMC-007-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) DMC-008-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) DMC-009-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) DMC-014-02-01 TAS 125 2003
PRI Construction Materials Technologies (TST5878) DMC-016-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) DMC-030-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) HTL-013-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) HTL-014-02-01 TAS 100 1995
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 2 of 4 Page 2 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
PRODUCT DESCRIPTION
DMC 100NS Profile: 1 in. snap lock seam; Max.16 in. coverage
Description: Non-structural, snap lock standing seam roof panel with integral perorated nail
strip
Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
DMC 150SS Profile: 1.5 in. mechanical seam; Max. 16 in. coverage
Description: Non-structural, mechanical lock standing seam roof panel
Material: Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 16 ksi; Shall
conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
DMC 175S Profile: 1.75 in. snap lock seam; Max. 18 in. coverage
Description: Non-structural, snap lock standing seam roof panel
Material: 0.032-inch (Fy = min. 24 ksi) or 0.040-inch (Fy = min. 20 ksi) Fluropon® coated
ASTM B209 aluminum; Shall conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90ASTM A792 or ASTM A653; Fy = min. 50 ksi; Shall conform with
FBC Section 1507.4.3
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 3 of 4 Page 3 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
DMC 200S Profile: 2 in. mechanical seam; Max. 16 in. coverage
Description: Non-structural, mechanical lock standing seam roof panel
Material: Min. 0.040 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 20 ksi; Shall
conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
DMC 5V Profile: 3/8 in. ribs; Min. 21 in., Max. 24 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 26 ga. Fluropon® coated ASTM A792 or ASTM A653 G90 ; Fy = min. 50 ksi;
Shall conform with FBC Section 1507.4.3
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 19 ksi; Shall
conform with FBC Section 1507.4.3
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. The roof deck and the roof deck attachment information are provided based on testing. FBC requirements
for the rational design of the roof deck, including the attachment, are not within the scope of this
evaluation.
3. Roof slope shall be 2:12 or greater.
4. Reroofing shall be in accordance with Section 1521.
5. Installation of the evaluated products shall comply with this report, RAS 133, and the manufacturer’s
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
6. All products listed in this report shall be manufactured under a qualit y assurance program in compliance with
Rule 61G20-3.
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 4 of 4 Page 4 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition (2020) High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted
by the named manufacturer.
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1)APPENDIX A – Installation (9 pages)
2)APPENDIX B – Approved Roof Systems (5 pages)
3)APPENDIX C – Design Wind Loads(3 pages)
2020.08.09
15:10:24
-04'00'
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 1 of 9 Page 1 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
INSTALLATION
Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Component Product Installation Detail
Fasteners
#9-15 HWH wood screw
with sealing washer Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion
resistant in accordance with FBC section 1507.4.4. #10-13 PH wood screw
#10-16 DP3 PH self-
drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be
corrosion resistant in accordance with FBC section 1507.4.4. #14-13 DP1 PH self-
drilling screw
Bearing Plates 18 ga. Bearing Plate
Clips
24 ga. DMC 150SS Clip
24 ga. SS in-seam clip
24 ga. DMC 150SS Fixed
Clip
24 ga. in-seam clip
Clips 22 ga. DMC 150SS Clip
22 ga. SS in-seam clip
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 2 of 9 Page 2 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Component Product Installation Detail
22 ga. DMC 150SS Fixed
Clip
22 ga. in-seam clip
DMC 150SS Butterfly
Clip
22 ga. base; 24 ga. butterfly in-seam clip
DMC 150SS Continuous
Butterfly Clip
22 ga. base; 24 ga. butterfly in-seam clip
Clips DMC 175S UL Clip
18 ga. in-seam clip
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 3 of 9 Page 3 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Component Product Installation Detail
lips (Cont’d)
DMC 200S Clip
22 ga. SS in-seam clip
DMC 200S Butterfly Clip
18 ga. base; 22 ga. butterfly in-seam clip; 4.5 in. length
DMC 200S Continuous
Butterfly Clip
18 ga. base; 22 ga. butterfly in-seam clip; 120 in. length; top slider 12 in. o.c.
Sealants Bostik 70-05A Shall be applied in continuous beads along the seam Bostik Chem-Calk 915
Fastening Details
Nomenclature Attachment
DMC 100NS Standard
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 4 of 9 Page 4 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 100NS Enhanced
DMC 150SS Continuous
Butterfly
DMC 150SS Butterfly
DMC 150SS Fixed - 90
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 5 of 9 Page 5 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 150SS Standard (Al)
DMC 150SS Fixed
Enhanced - 90
DMC 150SS Fixed
Enhanced - 180
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 6 of 9 Page 6 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 150SS Enhanced (Al)
DMC 175S #10 Standard
DMC 175S #14 Standard
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 7 of 9 Page 7 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 200S Butterfly
DMC 200S Butterfly (Steel)
Use 18 ga. bearing plate over polyisocyanurate insulation
DMC 200S Continuous
Butterfly (Steel)
Use 18 ga. bearing plate over polyisocyanurate insulation
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 8 of 9 Page 8 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 200S Fixed
DMC 200S Fixed
Enhanced
DMC 5V Standard
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 9 of 9 Page 9 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 5V #10 Standard
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX B
APPROVED ROOF SYSTEMS
The following notes shall be observed when using the assembly tables below.
1. Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1523.4.
2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system.
5. Underlayment shall be installed in accordance with FBC requirements. The minimum underlayment shall be ASTM D 226, Type II installed as described
in FBC Section 1518.2.1 with nails and tin caps per 1517.5.
6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy = min.40 ksi) Wide Rib Deck (Type WR)
conforming to ANSI/SDI-RD1.0 & FBC. In no case shall the panels be installed on less than two continuous spans, which are spaced a maximum 5 -ft o.c.
At minimum, the deck shall be attached with one (1) #12 x 1.5-inch HWH self-drilling screws at the bottom of each flute (maximum. 6-inch o.c. along the
support). At minimum, the deck side laps shall be fastened a maximum 6-inch o.c. with #12 x 1.5-inch HWH self-drilling screws.
7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 19/32-inch thick APA Span-Rated plywood
sheathing or wood plank at maximum 24-inch span for new construction. Existing construction shall be the minimum plywood sheathing or wood plank
thickness at maximum 24-inch span as stated in the approval tables on following pages . In no case shall the attachment be less than 8d ring shank nails
spaced 6-inch o.c.
Roof System Numbers and Definitions
100NS-W# DMC 100NS over Wood Deck (New or Existing)
150SS-W# DMC 150SS over Wood Deck (New or Existing)
175S-S# DMC 175S over Steel Deck (New or Existing)
175S-W# DMC 175S over Wood Deck (new or Existing)
200S-S# DMC 200S over Steel Deck (New or Existing)
200S-W# DMC 200S over Wood Deck (New or Existing)
5V-W# DMC 5V over Wood Deck (New or Existing)
Approved Systems for DMC 100NS over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
100NS-W1 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 100NS
Max. 16-inch wide DMC 100NS Standard attachment
with fasteners spaced 10.5 in. o.c. -97.5
100NS-W2 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 100NS
Max. 16-inch wide DMC 100NS Standard attachment
with fasteners spaced 5.25 in. o.c. -120
100NS-W3 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 100NS
Max. 16-inch wide DMC 100NS Enhanced attachment
with fasteners spaced 5.25 in. o.c. -135
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX B
Approved Systems for DMC 150SS over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
150SS-W1 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 0.032” Al DMC 150SS
Max. 16-inch wide
180° seam
DMC 150SS Standard (Al) attachment
with clips spaced 16 in. o.c. -90
150SS-W2 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide
90° seam
DMC 150SS Fixed - 90 attachment
with clips spaced 16 in. o.c. -90
150SS-W3 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide
180° seam
DMC 150SS Butterfly attachment
with clips spaced 16 in. o.c. -99.25
150SS-W4 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide
180° seam
DMC 150SS Continuous Butterfly attachment
with fasteners spaced 12 in. o.c. -114.25
150SS-W5 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide
Min. 90° seam
DMC 150SS Fixed Enhanced - 90 attachment
with clips spaced 12 in. o.c. -150
150SS-W6 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide
Min. 180° seam
DMC 150SS Fixed Enhanced - 180 attachment
with clips spaced 8 in. o.c. -165
150SS-W7 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 0.032” Al DMC 150SS
Max. 16-inch wide
180° seam
DMC 150SS Enhanced (Al) attachment
with clips spaced 8 in. o.c. -180
Approved Systems for DMC 175S over Steel Deck (New or Existing)
System
No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
175S-S1 Min. 22 ga.
Type B Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 0.040” Al DMC 175S
Max. 17.5-inch wide DMC 175S #14 Standard attachment
with clips spaced 18 in. o.c. -88
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX B
Approved Systems for DMC 175S over Steel Deck (New or Existing)
System
No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
175S-S2 Min. 22 ga.
Type B Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 0.040” Al DMC 175S
Max. 17.5-inch wide DMC 175S #14 Standard attachment
with clips spaced 12 in. o.c. -129.25
Approved Systems for DMC 175S over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
175S-W1 Min. 15/32
CDX plywood -
ASTM D 226, Type II roofing felt attached per
1518.2.1 with nails and tin caps per 1517.5
followed by Metshield High-Temp
Underlayment self-adhered to felt
0.032” Al DMC 175S
Max. 18-inch wide
DMC 175S #10 Standard attachment
with clips spaced 24 in. o.c. -74.75
175S-W2 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 24 ga. DMC 175S
Max. 18-inch wide DMC 175S #10 Standard attachment
with clips spaced 16 in. o.c. -84.25
175S-W3 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 0.040” Al DMC 175S
Max. 17.5-inch wide DMC 175S #10 Standard attachment
with clips spaced 18 in. o.c. -106.75
175S-W4 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 24 ga. DMC 175S
Max. 18-inch wide DMC 175S #10 Standard attachment
with clips spaced 8 in. o.c. -121.75
175S-W5 Min. 15/32
CDX plywood -
ASTM D 226, Type II roofing felt attached per
1518.2.1 with nails and tin caps per 1517.5
followed by Metshield High-Temp
Underlayment self-adhered to felt
0.032” Al DMC 175S
Max. 18-inch wide
DMC 175S #10 Standard attachment
with clips spaced 6 in. o.c. -131
Approved Systems for DMC 200S over Steel Deck (New or Existing)
System
No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
200S-S1 Min. 22 ga.
Type B Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Butterfly (Steel) attachment
with clips spaced 24 in. o.c. -88
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 4 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX B
Approved Systems for DMC 200S over Steel Deck (New or Existing)
System
No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
200S-S2 Min. 22 ga.
Type B Steel As required None As required per FBC 24 ga. DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Butterfly (Steel) attachment
with clips spaced 24 in. o.c. -91.75
200S-S3 Min. 22 ga.
Type B Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Continuous Butterfly (Steel)
attachment with clips spaced 12 in. o.c. -121.75
200S-S4 Min. 22 ga.
Type B Steel As required None As required per FBC 24 ga. DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Continuous Butterfly (Steel)
attachment with clips spaced 12 in. o.c. -151.75
Approved Systems for DMC 200S over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
200S-W1 Min. 19/32
CDX plywood OPTIONAL
Versashield Solo As required per
FBC
0.040” Al DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Fixed attachment
with clips spaced 16 in. o.c. -105
200S-W2 Min. 19/32
CDX plywood OPTIONAL
Versashield Solo As required per
FBC
0.040” Al DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Fixed Enhanced attachment
with clips spaced 8 in. o.c. -180
Approved Systems for DMC 5V over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
5V-W1 Min. 15/32
CDX plywood
OPTIONAL
Versashield Solo
ASTM D 226, Type II roofing felt attached
per 1518.2.1 with nails and tin caps per
1517.5 followed by Metshield High-Temp
Underlayment self-adhered to felt
0.032” Al DMC 5V
Min. 21-inch to
Max. 24-inch coverage
DMC 5V #10 Standard attachment
with #10-14 HWH wood screws with
sealing washers spaced 18 in. o.c.
-56
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 5 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX B
Approved Systems for DMC 5V over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
5V-W2 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 26 ga, DMC 5V
Min. 21-inch to
Max. 24-inch coverage
DMC 5V Standard attachment
with clips spaced 16 in. o.c. -60
5V-W3 Min. 15/32
CDX plywood
OPTIONAL
Versashield Solo
ASTM D 226, Type II roofing felt attached
per 1518.2.1 with nails and tin caps per
1517.5 followed by Metshield High-Temp
Underlayment self-adhered to felt
26 ga. DMC 5V
Min. 21-inch to
Max. 24-inch coverage
DMC 5V #10 Standard attachment
with #10-14 HWH wood screws with
sealing washers spaced 24 in. o.c.
-71
5V-W4 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 26 ga, DMC 5V
Min. 21-inch to
Max. 24-inch coverage
DMC 5V Standard attachment
with clips spaced 8 in. o.c. -121.75
5V-W5 Min. 15/32
CDX plywood
OPTIONAL
Versashield Solo
ASTM D 226, Type II roofing felt attached
per 1518.2.1 with nails and tin caps per
1517.5 followed by Metshield High-Temp
Underlayment self-adhered to felt
26 ga. DMC 5V or
0.032” Al DMC 5V
Min. 21-inch to
Max. 24-inch coverage
DMC 5V #10 Standard attachment
with #10-14 HWH wood screws with
sealing washers spaced 6 in. o.c.
-206
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX C
DESIGN WIND LOADS
The following tables provide design wind loads for components and cladding in accordance with Section 1620 of the FBC and ASCE 7-16 under the following
provisions:
1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1620 of the FBC.
2. Exposure C and D shall be as defined in section 1620 of the FBC.
3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
4. All calculations are based on an effective wind area of 10-ft2 or less.
5. Topographic factors such as escarpments or hills have been excluded from the analysis
6. Overhangs have been excluded from the analysis.
7. Wind directionality factor, Kd = 0.85
8. Design wind loads are calculated using Pasd = 0.6Pult.
9. Zone 2 is inclusive of Zone 2e, Zone 2n, and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
12. Zones 1, 2, and 3 shall be defined as shown below. Dimension “a” shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever
is smaller, but not less than either 4% of the least horizontal dimension or 3ft
Gable Hip
.
a a a
3 3 a
2 2 1
2 3
a 3
2
a
3
2
2 3
3
1 2
2 3
a a
a
a
a
3
3 2
2
1
1
2 2 1
a
2 2 1
3
3
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX C
Gable/Hip Roofs in Exposure C in Miami-Dade & Broward County (Roof slopes between 2:12 and 12:12)
Building Type Zone Mean Roof
Height (ft)
Basic Wind Speed (mph)
Risk Cat I Risk Cat I Risk Cat II Risk Cat II Risk Cat III, IV Risk Cat III,IV
156 165 170 175 180 186
Enclosed/
Partially Open
1
20 -62.3 -69.7 -74.0 -78.5 -83.0 -88.6
25 -65.1 -72.8 -77.3 -81.9 -86.7 -92.6
30 -67.9 -75.9 -80.6 -85.4 -90.4 -96.5
40 -72.0 -80.6 -85.6 -90.7 -95.9 -102.4
50 -75.5 -84.5 -89.7 -95.0 -100.5 -107.3
60 -78.3 -87.6 -93.0 -98.5 -104.2 -111.3
2
20 -90.9 -101.7 -108.0 -114.4 -121.1 -129.3
25 -95.0 -106.3 -112.8 -119.5 -126.5 -135.0
30 -99.0 -110.8 -117.6 -124.6 -131.8 -140.8
40 -105.1 -117.6 -124.8 -132.2 -139.9 -149.4
50 -110.1 -123.2 -130.8 -138.6 -146.6 -156.6
60 -114.2 -127.7 -135.6 -143.7 -152.0 -162.3
3
20 -108.1 -120.9 -128.4 -136.0 -143.9 -153.7
25 -112.9 -126.3 -134.1 -142.1 -150.3 -160.5
30 -117.7 -131.7 -139.8 -148.1 -156.7 -167.3
40 -124.9 -139.7 -148.3 -157.2 -166.3 -177.6
50 -130.9 -146.5 -155.5 -164.7 -174.3 -186.1
60 -135.7 -151.8 -161.2 -170.8 -180.7 -192.9
Partially
Enclosed
1
20 -72.9 -81.6 -86.6 -91.8 -97.1 -103.7
25 -76.2 -85.2 -90.4 -95.8 -101.4 -108.3
30 -79.4 -88.8 -94.3 -99.9 -105.7 -112.9
40 -84.3 -94.3 -100.1 -106.0 -112.2 -119.8
50 -88.3 -98.8 -104.9 -111.1 -117.6 -125.5
60 -91.6 -102.4 -108.7 -115.2 -121.9 -130.2
2
20 -101.5 -113.6 -120.6 -127.8 -135.2 -144.3
25 -106.0 -118.6 -125.9 -133.4 -141.2 -150.7
30 -110.5 -123.7 -131.3 -139.1 -147.2 -157.1
40 -117.3 -131.2 -139.3 -147.6 -156.2 -166.8
50 -123.0 -137.5 -146.0 -154.7 -163.7 -174.8
60 -127.5 -142.6 -151.4 -160.4 -169.7 -181.2
3
20 -118.7 -132.8 -140.9 -149.3 -158.0 -168.7
25 -124.0 -138.7 -147.2 -156.0 -165.0 -176.2
30 -129.2 -144.6 -153.5 -162.6 -172.0 -183.7
40 -137.1 -153.4 -162.9 -172.6 -182.6 -195.0
50 -143.7 -160.8 -170.7 -180.9 -191.4 -204.3
60 -149.0 -166.7 -177.0 -187.5 -198.4 -211.8
A CREEK
Technical Services, LLC
DRX15002.6 FL17679-R6 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX C
Gable/Hip Roofs in Exposure D in Miami-Dade & Broward County (Roof slopes between 2:12 and 12:12)
Building Type Zone Mean Roof
Height (ft)
Basic Wind Speed (mph)
Risk Cat I Risk Cat I Risk Cat II Risk Cat II Risk Cat III, IV Risk Cat III,IV
156 165 170 175 180 186
Enclosed/
Partially Open
1
20 -74.8 -83.7 -88.8 -94.1 -99.6 -106.3
25 -77.6 -86.8 -92.1 -97.6 -103.3 -110.3
30 -80.4 -89.9 -95.4 -101.1 -107.0 -114.2
40 -84.5 -94.5 -100.4 -106.3 -112.5 -120.1
50 -88.0 -98.4 -104.5 -110.7 -117.1 -125.1
60 -90.7 -101.5 -107.8 -114.2 -120.8 -129.0
2
20 -109.1 -122.1 -129.6 -137.3 -145.3 -155.1
25 -113.2 -126.6 -134.4 -142.4 -150.7 -160.9
30 -117.2 -131.1 -139.2 -147.5 -156.0 -166.6
40 -123.3 -137.9 -146.4 -155.1 -164.1 -175.2
50 -128.3 -143.6 -152.4 -161.5 -170.8 -182.4
60 -132.4 -148.1 -157.2 -166.6 -176.2 -188.2
3
20 -129.7 -145.1 -154.0 -163.2 -172.7 -184.4
25 -134.5 -150.5 -159.7 -169.3 -179.1 -191.2
30 -139.3 -155.9 -165.4 -175.3 -185.5 -198.1
40 -146.5 -163.9 -174.0 -184.4 -195.1 -208.3
50 -152.5 -170.6 -181.1 -192.0 -203.1 -216.8
60 -157.3 -176.0 -186.8 -198.0 -209.5 -223.7
Partially
Enclosed
1
20 -87.5 -97.9 -103.9 -110.1 -116.5 -124.4
25 -90.7 -101.5 -107.8 -114.2 -120.8 -129.0
30 -94.0 -105.1 -111.6 -118.3 -125.1 -133.6
40 -98.8 -110.6 -117.4 -124.4 -131.6 -140.5
50 -102.9 -115.1 -122.2 -129.5 -137.0 -146.3
60 -106.1 -118.7 -126.0 -133.6 -141.3 -150.9
2
20 -121.8 -136.3 -144.7 -153.3 -162.2 -173.2
25 -126.3 -141.3 -150.0 -159.0 -168.2 -179.6
30 -130.8 -146.4 -155.4 -164.7 -174.2 -186.0
40 -137.6 -154.0 -163.4 -173.2 -183.2 -195.6
50 -143.3 -160.3 -170.1 -180.3 -190.7 -203.6
60 -147.8 -165.3 -175.5 -186.0 -196.7 -210.1
3
20 -142.4 -159.3 -169.1 -179.2 -189.6 -202.5
25 -147.7 -165.2 -175.4 -185.8 -196.6 -210.0
30 -153.0 -171.1 -181.6 -192.5 -203.6 -217.4
40 -160.9 -180.0 -191.0 -202.4 -214.2 -228.7
50 -167.5 -187.3 -198.9 -210.7 -223.0 -238.1
60 -172.7 -193.2 -205.1 -217.4 -230.0 -245.6