FL# FL14317-R7
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Boral Roofing/MonierLifetile
Address/Phone/Email 7575 Irvine Center Drive
Suite 100
Irvine,CA 92618
(602)269-2288 Ext8320
thomas.jemmett@boral.com
Authorized Signature Thomas 3emmett
BoralRoofingUSAQuality@boral.com
Technical Representative Adrian Cooper THESE
PU,i aS AND ALL PROPOSED WORK
Address/Phone/Email 135 NW 20th Street Boca Raton,FL 33431 ASne yl 1SECT TO ANY COPREC NONI J
acoopeer@minlerlifetile.com �=�tuIP�LD BY FIELD INSPECTORS THAT
�v1.kf aE'NIECESSARY IN ORDER TO
Quality Assurance Representative C li`l�t•�WITH ALL APRIvABLE 00DES.
� Address/Phone/Email L
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
0 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J. M. Nieminen
the Evaluation Report CONCH FASTENERS OR ATTACHMENTS
Florida License PE-59166
Quality Assurance Entity UL LLC R`HE ed
IB eTY OF THE
Quality Assurance Contract Expiration Date 10/13/2017 r�tae E19
validated By John W. Knezevich,PE WNWOR
ID Validation Checklist-Hardcopy Received
Certificate of Independence FL14317 R7 COI 2015 01 COI Nieminen.odf
F
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
FRSA/TRI,(April.24.1?a.44=12--- - " --- 2012.
TAS 103 ---- 1995—
------ ------ ----
- UL1897 2004
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsbCUITKel20... 9/29/2017
FILE
CO
t
TRINITY ERA
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Laboratory Report;refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop Boral Roof Underlayments are follows. Table 1 pertains to use of each listed
underlayment by-itself beneath the stated roof covers. Refer to the installation instructions and Table 2 for two-ply
underlayment options.
R00F COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate
Shingles &Shingles
Boral TileSeal 50"T Yes Yes No Yes Yes Yes
(battens only)
Boral TileSeal"T Yes Yes Yes Yes Yes Yes
(See 5.5.1)
GatorSeal Yes Yes No No Yes Yes
(battens only)
StormSentry Yes Yes No No Yes Yes
5.5.1 "Foam-On Tile" is limited to use of the following unless tensile adhesion /long term aging data from an accredited
testing laboratory is provided.
Underlayment Tile Adhesives
3M'"'2-Component Foam Roof Tile Adhesive AH-160(FL6332)
eoral TileSeal"T
3M-,Roof Tile Adhesive RTA-1(FL6276)
Dow TILE BOND'"Roof Tile Adhesive(FL717)
Convenience Products'Touch'n Sea)StormBond Roof Tile Adhesive(FL14506)
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Citadel Plus,Boral TileSeal 50HT,Boral TileSeal"T,StormSentry or GatorSeal:
➢ Plywood(unprimed or primed with ASTM D41 primer).
Boral TileSeal"T:
➢ OSB primed with ASTM D41 primer,
5.6.2 Wind Resistance of Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
prescriptively addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum Design
Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate
passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRI
April 2012(04-12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
5.6.2.1 Maximum Design Pressure=-105 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Ply: (Optional)Citadel Plus,self-adhered
Underlayment: Boral TileSeal"T,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1X"ring shank
nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
Exterior Research and Design,I.I.C. Evaluation Report M35710.12.10-118
Certificate of Authorization#9503 F1.14317-117
Revision 8:07/01/2015
Page 3 of 6
TRINITY ERD
5.6.2.2 Maximum Design Pressure=-202.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: ASTM D41 to the plywood deck
Base Ply: (Optional)Citadel Plus,self-adhered
Underlayment: Boral TileSeal"T,self-adhered,and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank
nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
5.6.3 Bond to Base Laver Underlayment:
Citadel Plus,Boral TileSeal 50"T,Boral TileSeal"T or GatorSeal: - COPY
➢ ASTM D226,Type II felt;Citadel Plus.
StormSentry:
➢ ASTM D226,Type II felt;Citadel Plus. r ,. LE
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1 or as tested in accordance with FBC Section
1504.3.1.
I 5.6.4 Bond to Other Substrate Types:
Citadel Plus,Boral TileSeal 50"T,Boral TileSeal"T,StormSentry or GatorSeal:
➢ ASTM D41 primed metal(e.g.,flashing metal,valley metal,etc).
Boral TileSeal"T:
➢ Huber Zip Deck(unprimed or primed with ASTM D41 primer);Dens Deck Prime.
Note:For installation under mechanically attached prepared roof coverings,insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval.
5.7 Exposure Limitations:
5.7.1 GatorSeal shall not be left exposed for longer than 30-days after installation,prior to placement of final roof cover.
5.7.2 StormSentry shall not be left exposed for longer than 90-days after installation,prior to placement of final roof cover.
5.7.3 Alcazar, Boral TileSeal 50"T and Boral TileSeal"T shall not be left exposed for longer than 180-days after installation,
prior to placement of final roof cover.
5.7.4 Citadel Plus,for use as a base-layer in a two-ply underlayment system,shall not be left exposed for longer than 180-
days after installation,prior to placement of subsequent underlayment layer.
6. INSTALLATION:
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Install self-adhering underlayment when ambient and surface temperatures are minimum 40°F and rising.
6.4 Citadel Plus:
6.4.1 Citadel Plus is limited to use as a base or mid-layer in multi-ply underlayment systems beneath Boral TileSeal 50"T,
Boral TileSeal HT GatorSeal or StormSentry.
6.4.2 Slope limitations are those associated with the top-layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by''/<-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a
weighted roller.
Boral recommends fastening of the top edge of the sheet to the deck with roofing nails, nails & tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses minimum 2 inches(horizontal lap)and minimum 4"end(vertical)laps.
Install final underlayment layer atop Citadel Plus per 'direct-to-deck' instructions for Boral TileSeal 50"T, Boral
TileSeal"T,GatorSeal or StormSentry.
I
Exterior Research and Design,I.I.C. Evaluation Report M35710.12.10-118
Certificate of Authorization#9503 FL14317-R7
Revision 8:07/01/2015
Page 4 of 6
TRINITY j ERD
6.4.4 To Base Sheet:
Install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.4.3 and when used as part of a multi-ply system.
Install Citadel Plus as a mid-ply in accordance with Boral Roofing published installation instructions and Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct-to-deck' instructions for Boral TileSeal 50HT, Boral
TileSealHT,GatorSeal or StormSentry.
6_5 Boral TileSeal 50HT:
6.5.1 Install Boral TileSeal SOHT in compliance with manufacturer's published installation instructions and the requirements
1
for ASTM D1470 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50HT on roof pitches less than 2:12.
6.5.3 Non-Tile Applications,Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
j extending over by''/<-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a
weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses the width of the black-selvedge area,minimum 3-inch.
Seal under end(vertical)laps using approved mastic,or use Joined and Folded Seam or Inverted Sheet Seam method
detailed in Boral Roofing published installation instructions.
6.5.4 Non-Tile Applications.to Base Sheet:
Install ASTM D226,Type II felt in accordance with Code requirements.
Install Boral TileSeal 50HT in accordance with Boral Roofing published installation instructions and Section 6.5.3,except
end(vertical)laps,described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in
contact with the fabric top surface,rolling the interface into place with a weighted roller.
6.5.5 Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Battens must be used for all tile installations atop Boral TileSeal 50HT. Boral Roofing's Elevated Batten System'" or
counter battens are required for roof pitches of 2%:12 to less than 4:12.
6.6 GatorSeal and StormSentry:
6.6.1 Install GatorSeal and StormSentry in compliance with manufacturer's published installation instructions and the
requirements for ASTM D1470 underlayments in FBC Sections 1507 for the type of prepared roof covering to be
installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12. Do not use StormSentry on roof pitches less than %:12 while
ensuring there is no possibility for ponding water on the surface of StormSentry.
6.6.3 Non-Tile applications,Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by'%-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a
lweighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses the width of the black-selvedge area,minimum 3-Inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self-adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller,or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
15-11
Exterior Research and Design, I.C.I. LF
COPY'
Evaluation Report M35730.12.30-R8
Certiflcate oJAuthariration#9503 FL14317-117
Revision 8:07/01/2015
Page 5 of 6
w
F LE7CO3nTNI"1"Y ERD
6.6.4 Non-Tile Applications.to Base Sheet:
Install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.4.
Install GatorSeal or StormSentry over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing
published installation instructions and Section 6.6.3 except end(vertical)laps,described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self-adhering bituminous underside is in
contact with the granular top surface,rolling the interface into place with a weighted roller.
6.6.5 Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Battens must be used for all tile installations atop GatorSeal.
j6_7 Boral TileSeal"T:
6.7.1 Install Boral TileSeal HT in compliance with manufacturer's published installation instructions and the requirements for
ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TileSeal HT on roof pitches less than 2:12.
6.7.3 Non-Tile Applications.Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,extending over by''/<-inch.Fold
the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed
rubberized asphalt onto the deck,pressing firmly into place. Roll into place with a weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses the width of the black-selvedge area,minimum 3-inch.
Seal under end (vertical)laps using approved mastic,or use Joined and Folded Seam or Inverted Sheet Seam method
detailed in Boral Roofing published installation instructions.
6.7.4 Non-Tile Applications.to Base Sheet:
Install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.4.
Install Boral TileSeal HT in accordance with Boral Roofing published installation instructions and Section 6.7.3, except
end(vertical)laps,described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in
contact with the fabric top surface,rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Battens must be used for all tile installations atop Boral TileSeal HT with roof pitches of 2%to less than 3:12. Boral
Roofing's Elevated Batten System or counter battens are required.
Approved foam adhesive may be used for roof slopes 2:12 and greater.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC.—QUA9625;(414)248-6409;Karen.buchmann@us.ul.com
-END OF EVALUATION REPORT-