Boral Roofing Evaluation Report M35710.12.10-R8
'i 7575 Irvine Center Drive FL14317-117
a
Ij Suite 100 Date of Issuance:12/21/2010
Irvine CA.92618 o Revision 8:07/01/2015
,l SCOPE:
ilk
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
Ii construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
4 herein have been evaluated for compliance with the 5th Edition(2014) Florida Building Code sections noted herein.
jl!f DESCRIPTION: Boral Roof Underlayments
t
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
jc CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
'(I ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
i' advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
7�.'. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
;( distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
VpPrepared by:
sl; - ... `s•QS�pSC.��J/(�O. �" I I I-I � 7� ,fa'
i l•n 1'� ,�, ��?j)(`) Ul�lkll I �I �� �•'P The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M. Nieminen;{P.E. %s�,'� 4 .`' P.E.on 07/01/2015.This does not serve as an electronically signed
I Florida Registration No.59166,-F'lorida DCA�`NE1983�m ,11 '�'"'���„""
document.Signed,sealed hardcopies have been transmitted to the
r'• Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity]ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
Il, which the evaluation reports are being issued.
1 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
i.
li. product.
�I 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof,is/was used for permitting or design guidance unless retained
' specifically for that purpose.
j;
r,
THESE PLANS AND ALL PROPOSED WORK
ARE SUaJFCT TO M°1 rc���1FG�lAN
°i. RFOUIRED I7f MID Ir1-"-��`f��,
MAY K NRCC 3WU I'fF IN)>3`rhi-n-Ci�,lo
L.,
;I
l
I
1�
;I
END
TRINI1Y I
j, ROOFING COMPONENT EVALUATION:
i ,
II 1. SCOPE:
•� Product Category: Roofing
Sub-Category: Underlayment
r Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance with the
Ef following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject
to the Installation Requirements and Limitations/Conditions of Use set forth herein.
of 2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift UL 1897 2004
I 1507.2.4,1507.2.8,1507.2.9.2,1507.4.5.1, Physical Properties ASTM D1970 2009
1507.4.5.2,1507.5.3,1507.5.3.2,1507.6.3,
I 1507.6.3.2,1507.7.3,1507.7.3.2
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
' Enti Examination Reference Date
ERD(TST6049) Wind Uplift T6460.06.07-R1 10/09/2007
I" ERD(TST6049) Physical Properties T33190.08.30 08/06/2010
ERD(TST 6049) Physical Properties M33180.08.10 10/09/2010
ERD(TST6049) Wind Uplift T37610.07.11 07/29/2011
ERD(TST 6049) Physical Properties B40380.08.12 08/28/2012
gy ERD(TST 6049) Physical Properties C41420.09.12-2 09/11/2012
ERD(TST 6049) Physical Properties 1341940.09.12 09/13/2012
)� ERD(TST 6049) Physical Properties B47390.07.14-1 07/31/2014
f ERD(TST 6049) Physical Properties 1347390.09.14 09/04/2014
.�.; PRI(TST 5878) Physical Properties NEI-006-02-01 04/01/2002
PRI(TST 5878) Physical Properties NEI-034-02-02 03/23/2006
i. PRI(TST 5878) Physical Properties NEI-045-02-01 08/08/2007
t PRI(TST 5878) Physical Properties NEI-053-02-01 05/01/2008
PRI(TST 5878) Physical Properties NEI-070-02-01 08/12/2009
1i PRI(TST 5878) Physical Properties NEI-031-02-02:REV 10.27.10 10/27/2010
3
g� PRI(TST 5878) y Physical Properties NEI-029-02-01REV:11.03.10 12/03/2010
c" PRI(TST 5878) Physical Properties NEI-046-02-01REV 12/17/2010
PRI(TST 5878) Physical Properties NEI-034-02-02/MLT-015-02-01 01/29/2013
tt!. PRI(TST 5878) Wind Uplift BORR-001-02-01 03/17/2015
PRI(TST 5878) Wind Uplift BO RR-005-02-01 06/24/2015
UL,LLC.(QUA 9625) Quality Assurance Service Confirmation,R14610 Exp.12/10/2017
l' UL,LLC.(QUA 9625) Quality Assurance Cross-Listing Confirmation,R16744 09/04/2013
UL,LLC.(QUA 9625) Quality Assurance Service Confirmation,R16744 Exp.10/13/2017
4. PRODUCT DESCRIPTION:
!I
4.1 Self-Adhering Underlavments:
4.1.1 Boral TileSeal® SO"T is a nominal 50-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof
underlayment.
i,
I.
4.1.2 Boral TileSeal® HT is a nominal 60-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof
underlayment.
4.1.3 GatorSeal®is a nominal 55-mil thick,granular-surfaced,fiberglass reinforced,self-adhering SBS modified bitumen roof
€€€ underlayment.
4.1.4 StormSentryTM is a nominal 120-mil thick,mineral-surfaced,fiberglass reinforced,self-adhering SBS modified bitumen
roof underlayment.
4.1.5 Citadel® Plus is a nominal 48-mil thick, fabric-surfaced, fiberglass reinforced, self-adhering SBS modified bitumen
roofing underlayment for use as a base-layer in two-ply underlayment systems.
f(E
C
( Exterior Research and Design,I.I.C. Evaluation Report M35710.12.10-118
j Certificate ofAuthorization#9503 FL14317-R7
t,.
Revision 8:07/01/2015
Page 2 of 6
I S.
k.
I,
�t -
I'5 QOTRRINITYIERD
IIi
{r' 5.6.2.2 Maximum Design Pressure=-202.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
' Primer: ASTM Q41 to the plywood deck
Base Ply: (Optional)Citadel Plus,self-adhered
Underlayment: Boral TileSeal"T,self-adhered,and back-nailed within the selvedge-edge side laps using 12 ga.x 1X"ring shank
nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
"R 5.6.3 Bond to Base Laver Underlayment:
I!' Citadel Plus,Boral TileSeal 50"T,Boral TileSeal"T or GatorSeal:
`4 ➢ ASTM D226,Type 11 felt;Citadel Plus.
StormSentry:
r,
! ➢ ASTM D226,Type II felt;Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
Ip i, codified requirements. For installations under foam-on,tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1 or as tested in accordance with FBC Section
1504.3.1.
5.6.4 Bond to Other Substrate Types:
Citadel Plus,Boral TileSeal 50"T,Boral TileSeal"r,StormSentry or GatorSeal:
➢ ASTM D41 primed metal(e.g.,flashing metal,valley metal,etc).
Boral TileSeal"r:
➢ Huber Zip Deck(unprimed or primed with ASTM D41 primer);Dens Deck Prime.
Note:For installation under mechanically attached prepared roof coverings,insulation shall be attached per minimum
j requirements of the prepared roof covering manufacturer's Product Approval.
3" a
5.7 Exposure Limitations:
5.7.1 GatorSeal shall not be left exposed for longer than 30-days after installation,prior to placement of final roof cover.
5.7.2 StormSentry shall not be left exposed for longer than 90-days after installation,prior to placement of final roof cover.
5.7.3 Alcazar, Boral TileSeal 50"T and Boral TileSeal"T shall not be left exposed for longer than 180 days after installation,
prior to placement of final roof cover.
4
5.7.4 Citadel Plus,for use as a base-layer in a two-ply underlayment system,shall not be left exposed for longer than 180-
days after installation,prior to placement of subsequent underlayment layer.
6. INSTALLATION:
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris priorto application,and prime the substrate(if applicable).
6.3 Install self-adhering underlayment when ambient and surface temperatures are minimum 40°F and rising.
6.4 Citadel Plus:
6.4.1 Citadel Plus is limited to use as a base or mid-layer in multi-ply underlayment systems beneath Boral TileSeal 50"r,
Boral TileSeal"T,GatorSeal or StormSentry.
6.4.2 Slope limitations are those associated with the top-layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by''/<-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a
weighted roller.
Boral recommends fastening of the top edge of the sheet to the deck with roofing nails, nails &tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses minimum 2 inches(horizontal lap)and minimum 4"end(vertical)laps.
Install final underlayment,layer atop Citadel Plus per 'direct-to-deck' instructions for Boral TileSeal 50"T, Boral
TileSeal"T,GatorSeal or StormSentry.
Exterior Research and Design,I.I.C. Evaluation Report M35710.12.10-R8
Certificate of Authorization#9503 F1.14317-117
Revision 8:01/01/2015
Page 4 of 6
a
'I5
i
�I
'\JTRINITY ERD
d. 6.4.4 To Base Sheet:
Install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral
fi! Roofing published installation instructions and Section 6.4.3 and when used as part of a multi-ply system.
Install Citadel Plus as a mid-ply in accordance with Boral Roofing published installation instructions and Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct-to-deck' instructions for Boral TileSeal 50"T, Boral
TileSeal"T,GatorSeal or StormSentry.
6_5 Boral TileSeal 50"T:
6.5.1 Install Boral TileSeal 50"T in compliance with manufacturer's published installation instructions and the requirements
for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed.
l' 6.5.2 Do not use Boral TileSeal 50"T on roof pitches less than 2:12.
'It
IIr4- 6.5.3 Non-Tile Applications.Direct to Deck:
l r,.
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by%-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a
weighted roller.
!i Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
Ij•' greater. Overlap successive courses the width of the black-selvedge area,minimum 3-inch.
Seal under end (vertical) laps using approved mastic,or use Joined and Folded Seam or Inverted Sheet Seam method
It detailed in Boral Roofing published installation instructions.
6.5.4 Non-Tile Applications,to Base Sheet:
'331 Install ASTM D226,Type II felt in accordance with Code requirements.
}i Install Boral TileSeal 50"T in accordance with Boral Roofing published installation instructions and Section 6.5.3,except
end(vertical)laps,described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in
contact with the fabric top surface,rolling the interface into place with a weighted roller.
6.5.5 Tile Applications:
V: Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
i'. above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage
g g p and/or damage to the
underlayment.
E'+ Battens must be used for all tile installations atop Boral TileSeal 50"T. Boral Roofing's Elevated Batten System'" or
counter battens are required for roof pitches of 2%:12 to less than 4:12.
6_6 GatorSeal and StormSentry:
6.6.1 Install GatorSeal and StormSentry in compliance with manufacturer's published installation instructions and the
requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be
installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12. Do not use StormSentry on roof pitches less than X:12 while
ensuring there is no possibility for ondin water on the surface of StormSentry.
g P Y P g
r•
6.6.3 Non-Tile applications.Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by%-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a
weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses the width of the black-selvedge area,minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self-adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller,or using the Inverted Sheet Seam detailed in Boral Roofing,published installation instructions.
Exterior Research and Design,LLC. Evaluation Report M35710.12.10-R8
Certificate of Authorization#9503 FL14317-117
Revision 8:07/01/2015
Page 5 of 6
'I.
'n
I ��
i
1;.
II11 _
W.
TRINITY ERD
k 6.6.4 Non-Tile Applications,to Base Sheet:
Install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.4.
l•:
Install GatorSeal or StormSentry over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing
published installation instructions and Section 6.6.3 except end(vertical)laps,described below.
1? Apply SBS Mastic under all side (vertical) laps or any other laps where the self-adhering bituminous underside is in
.( contact with the granular top surface,rolling the interface into place with a weighted roller.
I' 6.6.5 Tile Applications:
`y Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or'damage to the
underlayment.
Battens must be used for all tile installations atop GatorSeal.
� 6_7 Boral TileSeal"T:
¢Ia 6.7.1 Install Boral TileSeal HT in compliance with manufacturer's published installation instructions and the requirements for
1;
I, ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed.
"! 6.7.2 Do not use Boral TileSeal HT on roof pitches less than 2:12.
6.7.3 Non-Tile Applications.Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
4
i' manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,extending over by''/<-inch.Fold
the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed
L
rubberized asphalt onto thg deck,pressing firmly into place. Roll into place with a weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses the width of the black-selvedge area,minimum 3-inch.
l Seal under end (vertical)laps using approved mastic,or use Joined and Folded Seam or Inverted Sheet Seam method
I` detailed in Boral Roofing published installation instructions.
6.7.4 Non-Tile Applications,to Base Sheet:
? Install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.4.
Install Boral TileSeal HT in accordance with Boral Roofing published installation instructions and Section 6.7.3, except
end(vertical)laps,described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in
contact with the fabric top surface,rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
j;• underlayment.
I" Battens must be used for all tile installations atop Boral TileSeal HT with roof pitches of 2'/=to less than 3:12. Boral
{ Roofing's Elevated Batten System or counter battens are required.
Approved foam adhesive may be used for roof slopes 2:12 and greater.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the nam4d QA entity for information on plants covered under Rule 61G20-3 QA requirements.
[ 9. QUALITY ASSURANCE ENTITY:
�'- UL,LLC.—QUA9625;(414)248-6409;Karen.buchmann@us.ul.com
-END OF EVALUATION REPORT-
!4
r Exterior Research and Design,I.I.C. Evaluation Report M35710.12.10-118
Certificate of Authorization#9503 FL14317-R7
1 Revision 8:07/01/2015
Page 6 of 6
i
A%
I; ti
r;
is
�i
JB&B Engineering,Consultants, LLC
` 5203 Silver Charm Terrace
Wesley Chapel, FL 33544
I" Phone: 813-545-1323
Email: TSullivaneng(c�g mail.com
Florida Certificate of Authorization#30903
Product Evaluation Report(111)
i` (FL#21388.1)
,1
i Dynamic 1.0" Nail Strip 24 gage Galvalume
Non-HVHZ
7j
i' 1.0 Product Manufacturer: Dynamic Metals, LLC
'.p
3j 3201 SE Dominica Terrace
Stuart, FL,34997
{' 2.0 Code edition: Florida Building Code 5th edition (2014)-Building Volume-Non-HVHZ
Sections 1504.3.2 and 1504.7
3.0 Evaluation Method: Engineering Evaluation (method 1 D) in accordance with 61G20-3.005 F.A.C.
ks
4.0 Product Category: Roofing
4.1 Product Sub-Category: Metal Roofing
,.. 5.0 Product Description:
5.1-General Description: Dynamic 1.0" nailstrip 24 gage steel non structural roof deck
5.2 Fy= 50 ksi
5.3 Panel Thickness:. 20 Gage (0.0276") minimum coated thickness
5.4 Corrosion Resistance to comply with.Florida Building Code 5.th ed. (2014), section 1507.4.3
f;
5.5 Width: 15" maximum coverage
5.6 Rib Height: 1.0" major rib height @ 15"o.c:
6.0 Panel Fastener:#1,0 x V pancake head fastener through the nail strip 6"from ends and 6"o.c.with
an integral malelfemale integral snaplock with adhesive. Corrosion resistance per Florida Building Code
51h edition (2014), sections 1506.6 and 1507.4.4
6.1 Substrate Description: 1 layer of 30#organic felt paper or other underlayment compliant
with FBC chapter 15 over minimum 7/16" OSB (or 15/32"4-ply APA plywood) over 2x SYP rafters
spaced no more.than 24" o.c. Substrate must meet all applicable requirements and be designed
with the Florida.Building Code 51h edition (2014)
6.2 Design Uplift Pressures:
Field Installation 412.0 psf/2=206.0 psf(Fasteners spaced 6",o.c.And 6"from ends) Ap
7.0 Code Testing Performance Requirements:
a
7.1 UL 580-06-Test for Uplift Resistance of Roof Assemblies
7.2 UL 1897-04-Uplift Test for Roof Covering Systems J
8.0 Performance Test Results Summary:
j 8.1.Architectural Testing, Inc.West Palm Beach, FL(TST 1527), Report#G1195.06-450-44
,. 8.1.1 Signed/Sealed by Charles Anderson, P.E. on October 21st, 2016
8.1.2 UL580-06/UL 1897-04 Field Installation (-412.0,0 psf)
9.0 Installation Instructions:
t 9.1 Per manufacturer's installation instructions,and fastening patterns described herein
Pa 1 2
1,
2:
y�
JB&B Engineering Consultants, LLC
5203 Silver Charm Terrace
' Wesley Chapel, FL 33544
Phone: 813-545-1323
N!
Email:TSullivanengCaD-'gmail.com
Florida Certificate of Authorization#30903
Ir;
10.0 Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined
using Chapter 16 of the Florida Building Code 2014 for roof cladding wind loads. These component wind
loads for roof cladding are compared to the allowable design pressures listed herein. The, design
11; professional shall select the the appropriate erection details to reference in his drawings for proper fastener
attachment to hislher structure and analyze the panel fasteners for puNout and pullover: Support framing
must be in compliance with Florida Building. Code 2014 chapter 22 for steel, chapter 23 for wood and
it chapter 1.6 for structural loading.
r
1 11.0 Limits and Conditions of Use:
l4 11.1 Maximum allowabie.design pressures listed in this report
s 11.2 Fire classification has not been.considered and is outside the scope of this report
11.3 Panels were not evaluated structurally to resist shear diaphragm, axial, transverse or
ri
racking loads
{ 11.4 Alternate conditions not specifically addressed by this approval shall be designed by a
registered Florida Professional Engineer or Architect
11.5 The structural adequacy of the substrate bearing the wind loads superimposed by this
1, product are the responsibility of others
11.6 Underlayment shall comply with the Florida Building Code 51''edition (2014)
a 11.7 Minimum slope shall comply with the Florida Building Code 51'edition (2014, including
1. section 1507.4.2 and in.accordance-with the manufacturers recommendations. For
k slopes less than 3:12, lap sealant must be used in the panel side laps
12.0 QualityAssurance Entity: The manufacturer has established compliance of roof panel products in
tY: p p " .
accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality
s assurance program audited by an approved quality assurance agency.
13.0 Certificate of Independence: Pursuant to the requirements of 61G20-3 F.A.C, I hereby certify that
this Florida Professional Engineer, performing this evaluation, does not have nor will acquire an interest in
any company manufacturing or distributing products for which the report is being issued.This is also to
certify that this Florida Professional Engineer, does not have,nor will acquire a financial interest in any
V
other entity involved in the approval process of this product.
ir. 14.0 Certification: In the professional opinion of this evaluating engineer the aforementioned product,
meets the require mmjapp Florida Building Code 2014(5th edition), specifically sections 1504.3.2 and
1504.7 for use 4 opgV` 3e& utilized within the limits of use noted herein.
cEN
No 5535fi °
® • � TZ o
° 4
Thom s D. ts'°" R°°° G��°
FL PE#553 8°a �1V,�1—
1:
t 2 2
Ott:
,JB&B ENGINEERING, I,LC
CONSULTING ENGINEERS
r, DYNAMIC .METALS, LL.0 5203 Szlvcr Charzri.Terraoc
ii 3201 SE Dominica Torraco }YesLey'CNayel,,;FL.33544
Stuart, FtorWA 34997 Pliono (813)645=1323
(' Email TSulWidneny®gmndL 0'bm_
9,
FL;Cart-Eftcatc of`Authartzat4on 490905
4t
�p.
{
r
Drawing
i
rl
s.
Panel PrA1e.
r I
ky
Wood Beck: 0 V
i
't �d
{, F li)� r
— 'I0XT,
t'andip Spray
,
I :
MAXIMUM-DESIGN UPLIFT .PRESSURE=206.0 PSF
ANCHORS TO BE SPACED 6" FROM,ENDS,:&
� ._:. `>�` �f S:" •.'f`'per '
.'. e' ° ► n Client:Nae:DYNAMIC,METALS, LLD m
Project Name.DYNAMIC NAIL 1.0" STRIP 44 go STEEL.
T E O �.y�T
THOM LUV OMpud FLORIDA BUILDING CODE 5TH ED, project Addrasss FLORIDA PRODUCT-APPROVAL
5� J�B NO.:21-6-1062 DATE,'10n29-2016
®P � NAt_