HomeMy WebLinkAboutProduct Approval (2)' Florida Building Code Online 611117,8:38 AM
BCIS Home I Login User Registration J Hot Topics Submit Surcharge J Stats&Facts J Publications FBC Staff J 8CIS Site Map J Unks I`Search.J
Florda #14
Mt` n Product Approval
10 USER:Public User
too
Product Approval Menu>Product or Application Search>Application List>Application Detail 1 `�0`
FL# FL6332-R7 \`��
Application Type Revision
Code Version 2014
Application Status Approved
Comments RECEIVED
Archived
OCT 0 5 2017
Product Manufacturer ICP Adhesives&Sealants,Inc. PERMj"NG
Address/Phone/Email 12505 NW 44th Street
Coral Springs,FL 33065 St.Lucie Courity,FL
(888)774-1099 Ext201
bagne@icpadhesives.com
Authorized Signature Brett Agne
bagne@icpadhesives.com
Technical Representative Brett Agne
Address/Phone/Email 12505 NW 44th Street
Coral Springs, FL 33605
(888) 774-1099 Ext203
bagne@mmm.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roof Tile Adhesives
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
1, Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 06/05/2018
Validated By John W.Knezevich,PE
4! Validation Checklist-Hardcopy Received
Certificate of Independence FL6332 R7 OI 2016 01 COI Ni minen. df
Referenced Standard and Year(of Standard) Standard Year
ASTM E108 2007
i
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquanCtKft6f%2fM%2b3ax6XpXuollc9c9GFU6k%3d Page 1 of 2
Florida Building Code Online 611/17,8:38 AM
SSTD 11 1997
Equivalence of Product Standards
Certified By
i
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/17/2016
Date Validated 06/17/2016
Date Pending FBC Approval 06/20/2016
Date Approved 08/17/2016
Summary of Products
FL# Model,Number or Name Description
6332.1 ICP Adhesives Polyset AH-160 Dual component expanding polyurethane roof tile adhesive
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL6332 R7 IL2016 06 FINAL ER ICP AH160 FL6332-
Approved for use outside HVHZ:Yes R7.Ddf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:+n/a/-178 Created by Independent Third Party:Yes
Other: 1.)The design pressure limitation in this application Evaluation Reports
refers to hip and ridge tiles in one configuration. Refer to FL6332 R7 AE_2016 06 FINAL ER ICP AH160 FL6332-
Table 2 of ER for all hip and ridge the limitations.2.)Field R7.Ddf
tiles are designed based on overturning moment resistance. Created by Independent Third Party:Yes
Refer to Table 1 of ER for field the limitations.3.)Refer to ER
Sections 5 for other Limitations of Use.
Bact< tVext
Contact Us::2601 Blair Stone Road.Tallahassee Fl.32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact B50.487.1395."Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 4S5,F.S.,please click here.
Product Approval Accepts:
10
® h
Credit Card
Safe
https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquanCtKft6f%2fM*/2b3ax6XpXuollc9c9GFU6k%3d Page 2 of 2
i
Florida Building Code Online 611/17,8:38 AM
•r e - -
BCIS Home Log In { User Registration { Hot Topics ! Submit Surcharge i Stats&Facts { Publications { FBC Staff ; BCIS Site Map { unks { Search {
Florida
Product Approval
USER:Public User
Product Approval Menu>Product or Application Search>Application List
Search Criteria Refine Search
Code Version 2014 FL# 6332
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model, Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-Ap lications
FL# Type Manufacturer Validated By Status
FL6332-R7 Revision ICP Adhesives&Sealants,Inc. John W. Knezevich,PE Approved
History Category:Roofing (954)772-6224
Subcategory:Roof Tile Adhesives
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
I
i
https://www.floridabuilding.org/pr/pr_app_Ist.aspx Page 1 of 1
I
i
Y.
{ EXTERIOR RESEARCH&DESIGN,I.I.C.
Certfcote ofAuthorizatlon#9503
v TRINITYI 353 CHRISTIAN STREET,UNIT 13
ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
ICP Adhesives and Sealants,Inc. Evaluation Report 02768.03.06-R7
12505 NW 44th Street FL6332-117
Coral Springs,FL 33065 Date of Issuance:08/08/20DS
Revision 7:06/16/2016
SCOPE:
This Evaluation Report is Issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with
the 5th Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: ICP Adhesives Polyset®AH-160
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
�_ The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M.Nieminen,P.E. %�T�s o°s;r P.E on06/16/2016.This doesnotswe0anelectroNmRyslgned
Florida Registration No.59166,Florida DCAANE1983 i.._,{4i`nNi�`�* document.Signed,scaled hardcopies have been transmitted tothe
Product Approval Administratorand to the named dient
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research&Design,I.I.C.d/b/a Trinity ERD does not have,nor does it intend to acquire or will it acquire,a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, I.I.C. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither TrinityI ERD nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
I
I
TRINITY J ERD
ROOFING COMPONENT EVALUATION:
1. SCOPES
Product Category: Roofing
Sub-Category: Roof Tile Adhesives
Compliance Statement: ICP Adhesives Polysee AH-160, as produced by ICP Adhesives and Sealants, Inc., has
demonstrated compliance with the Florida Building Code through testing in accordance with the Standards set forth
herein. Compliance Is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Sections Property Standard Year
1505.1 External Fire Classification ASTM E108 2007
1711.2.1 Wind SSTD 11 1997
3. REFERENCES:
Entity Examination Reference Date
ERD(TST 6049) SSTD 11 P39740.02.12 02/20/2012
ERD(TST 6049) SSTD 11 P39740.11.13-R1 01/02/2015
ICC-ES(EVL2396) 2012 IBC Compliance ESR-1709 12/01/2014
ITS(TST 1585) ASTM E108 101646522SAT-001 Rev.1 12/23/2014
Miami-Dade(CER 1592) HVHZ compliance 16-0315.01 04/07/2016
PRI(TST 5878) SSTD 11 ECM-001-02-01 09/21/2001
PRI(TST 5878) SSTD 11 PFI-006-02-01 05/09/2005
PRI(TST 5878) SSTD 11 PFI-006-02-02 05/09/2005
PRI(TST 5878) TAS 101 PFI-007-02-01 10/11/2005
PRI(TST 5878) SSTD 11 PFI-008-02-04 02/21/2006
PRI(TST 5878) SSTD 11 PFI-009-02-03 02/21/2006
PRI(TST 5878) SSTD 11 TGRI-001-02-03 10/30/2006
PRI(TST 5878) SSTD 11 TGRI-001-02-03 10/30/2006
PRI(TST 5878) SSTD 11 PFPI-010-02-01 12/07/2006
PRI(TST 5878) SSTD 11 PFPI-DII-02-01 12/07/2006
PRI(T5T 5878) SSTD 11 PFPI-012-02-01 12/07/2006
PRI(TST 5878) SSTD 11 PFPI-013-02-01 12/07/2006
PRI(TST 5878) SSTD 11 PFPI-014-02-01 12/07/2006
PRI(TST 5878) TAS 101 ECM-003-02-01 06/13/2008
PRI(TST 5878) TAS 101 ECM-004-02-01 06/13/2008
PRI(TST 5878) TAS 101 ECM-005-02-01 06/13/2008
PRI(TST 5878) TAS SOS ECM-006-02-01 06/13/2008
PRI(TST 5878) TAS 101 ECM-007-02-01 06/13/2008
PRI(TST 5878) TA5101 ECM-008-02-01 06/13/2008
UL LLC(QUA 9625) Quality Assurance Service Confirmation Exp.06/05/2018
4. PRODUCT DESCRIPTION:
4.1 ICP Adhesives Polyset®AH-160 is a two-component expanding polyurethane roof tile adhesive that is mixed
and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are
available in refillable tanks or disposable cylinders(ICP Adhesives ProPacko 30&100).
I
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen,P.E.are,in anyway,the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
Exterior Research and Design,I.I.C. Evaluation Report 02768.03.06-R7
Certiftate of Authorization#9503 F1.6332-117
Revision 7;06/16/2016
Page 2 of 9
i
1'RININ J ERD
5.3 Concrete and clay tiles having a current Florida Statewide Product Approval or approved on a local-level by
the AHJ, adhered using ICP Adhesives Polyset® AH-160, maintain their respective roof fire classifications.
Refer to FBC 1505.2,Exception 2.
5.4 ICP Adhesives Polyset®AH-160 can be used with flat,low and high profile tiles or any rigid,discontinuous roof
assembly having a current Florida Statewide Product Approval or approved on a local-level by the AHJ.
5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide
Product Approval or approved on a local-level by the AHJ for use with ICP Adhesives Polyset®AH-160.
5.6 Field tiles using ICP Adhesives Polyset®AH-160 are limited to projects having an Aerodynamic Uplift Moment
(Ma),determined in accordance with FBC 1609.5.3 or Tables 2A and 2B of FRSA/TRI April 2012 (04-12), not
greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and
Sealants,Inc.published installation instructions for Adhesive Paddy Placement details.
t "AR
e s s - u r7a.z -u -7• „fax� -�} <
7AaLt iFit3a Tees IN iCP ADRE;IYES POLYSiE�'AH 160 a
r �- r "'r,�.-- ._, ALLOWABLEDVERTURNIflG MOMEHi,PERFORMANDTA ,�.�as , _
'` Y Z�ai axof3 rrwvaor umrophvo�voarr(s l oam,No+1uaus nr7rucEmr'xr 3, "�. .�' •,
., ? 4yro1�2trtrmoFsv�7r�garivAhpuFowxlxram[pFrmcnr,(nvo3wo�Puc `
Tile — - Allowable
Adhesive Paddy Placement Overturning
Type Profile Moment(ft-lbf)
Independent;Single Paddy,Medium(2x7-inch,-30 gram) 60
concrete Clay Flat Independent,Single Paddy,Large(WO-inch,-45 gram) 112
Interdependent;Two Paddy(44-inch on underlayment,2x4-inch at the overlap) 54
Independent;Single Paddy,Medium(2x7-inch,-30 gram) 39
Concrete
te Medium
Clay Low/ Independent,Single Paddy,Large(2x10-inch,-54 gram) 67
Interdependent,Two Paddy(4x4-inch on underlayment,2x4-inch at tile overlap) 58
Clay High Independent;Single Paddy,Large(WO-inch,-45 gram) 134
Independent;Single Paddy,Medium(2x7-inch,-30 gram) 65
Concrete Clay High Independent;Single Paddy,Large(WO-inch,-63 gram) 109
Interdependent;Two Paddy(4x4-inch an underlayment,2x4-Inch at file overlap) 40
Clay Barrel 2x10-Inch x-35 gram for pans;2 @ WO-inch x-17 gram for cap 147
Concrete Barrel 2x10-inch x-35 gram for pans;2 @ WO-Inch x^17 gram for cap 107
ClayCap atop 2x Independent:Continuous Paddy stringer P y("34 gram/ft) 135
Concrete Cap atop 2x stringer Independent:Continuous Paddy(-34 gram/ft) 116
Clay Cap atop 2x Interdependent: 105
stringer Head:One(1)#10 x 2W screw;Overlap:1 x 6 inch(-10.5 gram)
Concrete Cap atop 2x Interdependent: 76
stringer Head:One(1)#10 x 2%"screw;Overlap:1 x 6 inch("10.5 gram)
5.6.1 Data in Table 1 relates to installation over a'30/90'underlayment system,as detailed in the FRSA/TRI April
2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product
Approval and/or approved on a local-level by the AHJ specifically for use with ICP Adhesives Polyset®AH-160.
5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with
ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or TAS 101. For the
interdependent two-paddy method,an additional 2-to-1 margin above that specified in SSTD 11 or TAS 101
shall be applied in determiningthe'allowable overturning moment'.
Exterior Research and Design,I.I.C. Evaluation Report02768.03.06-R7
CertlJlcote ofAuthorimtion#9503 FL6332-R7
Revision 7:06/16/2016
Page 3 of 9
I
i
i
I
TRINITY I ERA
5.7 Hip and ridge tiles using ICP Adhesives Polyset®AH-160 are limited to projects having hip/ridge design pressure
requirements,determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the
following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive
Paddy Placement details.
r @';s �°7 'i
TABLE 2 (�iP&RIDGE.�T1u31N 1C P 71DAf51VEsP�otYSET�
�'�d �"�.."'.�.�
's,-� .x ,,, _ �+s ALLOWABLEUPLIFrRE515TANCEPERFa�iMANCEDATA+� gf a `
t ^.sb �� y�.4"'r... � T3'>+.'3 "-� x�y�.SS""'a-2,,•3.:r_s' roy-..$�i�.-F'�!�
2'rO1fMARGINOPSAFEJYNIR YAPPUEDFORINOEP�D (COhmflUoUSPADDY1 PlAf NEJ1}�p �y yyt
Allowable
Tile Substrate Attachment Method Design Pressure
(Psf)
Clay 2x PT ridge board Independent:Continuous Paddy(-34 gram/ft) 116
Concrete 2x PT ridge board Independent:Continuous Paddy(—34 gram/ft) 107
Clay 2x PT ridge board Interdependent:Head:One(1)#10 x 2W screw; 90
Overlap:I x 6 Inch("10.5 gram)
Concrete 2x PT ridge board Interdependent:Head:One(1)#10 x 2Y2"screw; 56
Overlap:1 x 6 inch(-10.5 gram)
Clay or Hip&Ridge Channel Metal(FL5374):
Independent:Continuous Paddy("34 gram/ft) 169
Concrete galvanized only
Clay or Trim Lock-(FL5374): aluminum, Independent:Continuous Paddy(^34 gram/ft) 173
Concrete galvanized,Galvalume 0 or stainless steel
Clay or Trim Lock'"Plus(FL5374): aluminum,
Concrete galvanized,Galvalume®or stainless steel Independent:Continuous Paddy(�34 gram/ft) 178
Clay Top Notch(FL8095) Independent:Continuous Paddy 32 gram/ft) 125
Concrete Top Notch(FL8095) Independent:Continuous Paddy("32 gram/ft) 146
6. INSTALLATION:
6.1 ICP Adhesives Polyset®AH-160 and the tile roof assembly shall be installed in accordance with FRSA/TRI April
2012(04-12)and ICP Adhesives and Sealants,Inc.published installation instructions,subject to the limitations
outlined in Section 5.
6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012(04-12).
Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product
Approval.
6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP
Adhesives and Sealants,Inc.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
8. MANUFACTURING PLANTS:
Tomball,TX
9. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;Karen.buch ma n nCcDus.ul.com
Exterior Research and Design,I.I.C. Evaluation Report 02768.03.06-R7
Certificate of Authorimtron NS03 FL6332-R7
Revision 7:06/16/2016
Page 4 of 9
I
I
TRINITY J ERD
10. PADDY PLACEMENT DETAILS(FROM ICP ADHESIVES AND SEALANTS,INC.PUBLISHED LITERATURE):
10.1 Independent,Medium Paddy:
Nail through plastic cement Paddy(Beneath Tile)
(when required) Nall through plastic cement
(when required)
Underlayment ° ° Paddy(Beneath Tile)
Underlayment
7
i i� 2m.
Battens optional ° / 2In.
Eave Course '
o Battens optional
Pasch
2 in
Eave Closure
Eave Closure Eave Course Fascia
Flat/Low Profile Tile Medium Profile Tile
Nail through Plastic c
(when required) Paddy(Beneath Tile)
IUndedayment
71n 21n.
Battens optional
a mot_
7
� Eave Course Fascia
Weephole
loin. 2 in. Eave closure
Dr(pedge
High Profile Tile
Exterior Research and Design,I.I.C. Evaluation Report 02768.03.06-R7
CertiJtcate of Authorization 09503 FL6332-R7
Revision 7:06/16/2.016
Page 5 of 9
I
i
I
�f RlNITY ERD
10.2 Independent,Large Paddy:
Nail through plastic cement Paddy l8eneathTile)
(when required) Nall through plastic cement
(whenrequired)
Underlayment _____ ..Paddy(8eneathTlle)
o `
yndedayment
_ y
101n.
Battens optional ' '" 21n.svide�► `a
m
Eavo Course 8atterti optional
10 in. �' FAsda 10 in. 2 in.,
r 2 in
Eave closure
Eave Closure Eave Course Fascia
Flat/Low Profile Tile Medium Profile Tile
Nail through plastic cepe
(when required) Paddy(Beneath Tile)
IUnderiayment
10 in.x
2 in.wide
Battens _
optional
)L Eave Course Fascia
weephole
loin. tin, Eave closure
Drip edge
High Profile Tile
Exterior Research and Design,LLC. Evaluation Report 02768.03.06-R7
t:ertfricote of Authorization 119503 FL6332-R7
Revision 7:06/16/2016
Page 6 of 9
iI
i
TRINITY ERD
10.3 Interdependent,Two Paddy.,
Na)I through plastic cement Paddy(between tiles)
(when required) Nall through plastic cement Single paddy under tile
(when required)
Battens optional ° Pad dy(betweenties)
o Paddy(under tile)
I Single paddy Battens Paddy lunder tile)
W on top of t8e pt
o tonal
4x4in. x
Single padd Singlepaddy
under d on top of dieSingle � a
,.
on undeer adyrrm x 4 in.
�2x4in. � /
° Single paddy on
° underlayment
10 . 42 in Fascia 10 in. 2in.
Eave Closure Eave Closure
Eave Course Fascia
Flat/Low Profile Tile Medium Profile Tile
Nall through plastic ce a Single paddy undertile
(when required)
Paddy(between tiles)
Battens
optional Paddy(under tile)
♦ Single paddy
on underiayment
nµ 4 z 4 in.
Single 2x4in,
paddyon
top of tile
Eave Course Fascia
weephole
10 in. 2in.
Eave closure
A„ ,�' Drip edge
High Profile Tile
Exterior Research and Design,LLC. Evaluation Report02768.03.MR7
CertlJicote ofAuthorlratlon M9503 FL6332-R7
Revision 7:06/16/2016
Page 7 of 9
I
VT�JRINITYJERD
10.4 Two Piece Barrel(Cap&Pan)Tile:
1)131anenoughadheshntoachleve6Sto70stpin. Steep pitch applications
in contaawith the pan tile. (when requiredi
2)Tum Coven upside down.Plaee edheaivo
1121n.to i Indt In fmm outside edge o1 aWor We
Instep Cover Bio.
Enstno 20 to 25 sq.in.contactarea on
a-h side of cover Wa
IUndedaymant �' a
V jl f r � r A e
Sheathing
Eavedosur
(momrshown)
Weaphole Fasds Board
Removetop portion of the eave course cover tile.Abut to second course of
pan tiles.Ensure eave end of pan and covertlles are flush at ewe Rne.
Two Piece Barrel-High Profile Tile
I0�5 Hip and Ridge(independent placement):
r
A bead of1CP Po1ywtIDAH460 my be applied above the PEW To Beech WrAIS U&3,a bead of iCPPolyseIXAH-160 shay
tM,5whoe on both sides ofthe blphWgeboard or 9llbaed bee 5ed Aano Ute cen;cr of Oreh tiddge Uomd or gatvimzed ahV'iQt`drzeaeai cllCp rJlxtsaH.frOreetde r@si+smry
1iP arp.nl` 0, fin1—�hordeek aCL-ES t adores blrbgIird.
,I.w frame to provide%ti ambbc mc. frame.
Exterior Research and Design,LLC. Evaluation Report02768.03.06-R7
CerfUlcore clAuthorirotlon#9503 FL6332-R7
Revision 7:06/16/2016
Page 8 of 9
i
i
/
NO
��WORN
�Se s. 'L
�` '?`�� - r
-; $
Mll-
'1011�1 Will
d•k
gam "
R