FL# FL7804-R9
Application Type Revision
OCT 0 5 2017
Code Version 2014
PER:IAI'r lNG
Application Status Approved
St. Lucie County, FL
Comments
Archived
Product Manufacturer Entegra Roof Tile,Inc.
Address Phone Email 1289 NE 9th Avenue
Okeechobee,FL 34972
(863)467-0042 Ext12-28
tjohnson@rooftile.com
Authorized Signature Terry Johnson
tjohnson@rooftile.com
Technical Representative Jim Deyarmond
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee,FL 34972
(863)467-0042
]Deyarmond@rooftile.com
Quality Assurance Representative Terry Johnson
Address/Phone/Email 819 South Federal Hwy Suite 300
Stuart,FL 34994
(800)586-7663
tjohnson@rooftile.com
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies,LLC
Quality Assurance Contract Expiration Date 11/04/2017
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL7804 R9 COI 2016 01 COI Nieminen.pdf
hops:/(www.floridabuilding.org/pr/pr_app dtl.aspXtparam=wGEVXQwtDquovOJOH1%2bAMgs179%2bkb9MWKigi8oylmr8%3d Pa 3
Florida Building Code Online 4/25117,2:30 PM
Referenced Standard and Year(of Standard) Standard Year
ASTM C1492 2003
FRSA/TRI April 2012 2012
SSTD 11 1997
TAS 100 1995
TAS 101 1995
TAS 102 1995
TAS 102(A) 1995
TAS 112 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/19/2016
Date Validated 04/20/2016
Date Pending FBC Approval 04/24/2016
Date Approved 06/08/2016
Summary of Products
FL# Model,Number or Name Description
7804.1 Entegra Concrete Roof Tiles(HVHZ Concrete Roof Tile
jurisdictions)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL7804 R9 11 2016 04 FINAL ER ENTEGRA FL7804-
Approved for use outside HVHZ:No R9 HVHZ.odf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Use.Refer to ER Evaluation Reports
Section 6 for Installation. FL7804 R2_AE 2016 Q4__FINAL ER ENTEGRA FL7804-
R9—HVHZ.odf
Created by Independent Third Party:Yes
7804.2 Entegra Concrete Roof Tiles(non- Concrete Roof Tile
HVHZ jurisdictions)
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL7804 U 11 2016 04 FINAL ER ENTEGRA FL7804-
Approved for use outside HVHZ:Yes R9 NON-HVHZ.odf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Use.Refer to ER Evaluation Reports
Section 6 for Installation. FL7804 R9 AE 2016 QA__FINAL ER ENTEGRAFL7804-
R9 NON-HVHZ.odf
Created by Independent Third Party:Yes
Back next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Go2yriaht 2007-2013 State of Florida.::Privaw Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emells provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
https://www.floridabuilding.org/pr/pr_app dti.aspxC?param=wGEVXQwtDquovOjOHI%2bAMgsl7g%2bkb9MWKlgi8oylmrS%Sd Page 2 of 3
I
Florida Building Code Online 4/25117,2:30 PM
i supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please dick here.
Product Approval Accepts:
Credit Card
Safe
https://www.flaridabuilding.orgipr/pr_app dtl.aspx?param=wGEVXQwtDquovOJOHI%2bAMgsl79%2bkb9MWKigigoyimrS%3d Page 3 of 3
I
i
i
/~"'• EXTERIOR RESEARCH&DESIGN,I.I.C.
Certlffcate of Authorization#9503
TRINITY I ERD 353 CHRISTIA STREETOXFORD,,UNIT#13 CT 6478
I PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
rm= Entegra Roof Tile,LLC Evaluation Report E39310.11.11-1-R3
r.NM-G RA 1289 NE 9th Avenue FL7804-119
R O O F T I L E Okeechobee,FL 34972 Date of Issuance:11/02/2011
Revision 3:04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
(HVHZ)sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles(HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words '?rinityI ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
li
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by: R�IR�t,tln,,,,�—
: The facsimile seals appearing was authorizedb Robert Nleminen,
Robertl.M.Nieminen,P.E. ;o•.,F; ;`�;� .T e y
4,�FS• • P.E on OE/18J2016.This does no[serve as an electronlsa8yzlgned
Florida Registration No.59166,Florida DCA ANE1983 ; 0 �tssis•' document.Signed,seated hardcoples ham been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitvlERD nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
I
I
ERD
TRINITY
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Category:
Product
i g ry: Roofing
Sub-Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and limitations/ Conditions of Use set forth
herein.
2. STANDARDS:
Section Property Standard Year
1523.6.5.2 Physical Properties TAS 112 1995
1523.6.5.2 Wind Driven Rain TAS 100 1995
1523.6.5.2.2 Static Uplift Resistance TAS 101 1995
1523.6.5.2.3 Static Uplift Resistance TAS 102 1995
1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) TAS 101 P39740.02.12 02/21/2012
ATL(TST3782) Physical Properties RT0624.05-14 07/03/2014
ATL(TST3782) Physical Properties RT0624.04-14 07/07/2014
ATL(TST3782) Physical Properties RT1210.02-15 12/17/2015
ATL(TST3782) Physical Properties RT1230.03-15 12/17/2015
ATL M 3782) Physical Properties RT1103.01-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.02-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.03-15 11/07/2015
ATL(TST 3782) Physical Properties RT1303.04-15 11/07/2015
ATL(TST 3782) Physical Properties RT3103.05-15 11/07/2015
Miami-Dade(CER1592) HVHZ Compliance 14-0416.12 12/27/2014
Miami-Dade(CER1592) HVHZ Compliance 15-0722.04 11/05/2015
Miami-Dade(CER1592) HVHZ Compliance 16-0112.06 02/25/2016
Miami-Dade(CER1592) HVHZ Compliance 16-0112.07 02/25/2016
Miami-Dade(CER1592) HVHZ Compliance 16-0112.08 02/25/2016
Tile Roof Institute TAS 100,TAS 101,102,102(A) Membership Confirmation Current
PRI(QUA9110) Quality Assurance Inspection Report 11/04/2015
Exterior Research and Design,U.C. Evaluation Report E39330.11.11-1-83
Certifloate of Authorization#9503 FL7804-119
Revision 3:04/18/2016
Page 2 of 9
I
�l
I
TRINITY ERD
4. PRODUCT DESCRIPTION:
4.1 BERMUDA FLAT,PLANTA�FLAT nd HORIZON FLAT are TAS 112,Type 3a(flat-profile)concrete roof tiles.
i- 16' —i
10'
Y
j- --16.
-f
10,
Y
Bermuda Flat .
�3
lantation Flat
13"
Horizon Flat
Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-113
Certificate of Authorization#9503 FL7804-119
Revision 3:0411812016
Page 3 of 9
I
TRINITY J ERD
i
4.2 BEIJA HIGH"S"are TAS 112,Type la(interlocking,high-profile)concrete roof tiles.
i
1 t3 4"
y
Bella High"S"
4.3 ESTATE"S"and HACIENDA are TAS 112,Type lb(interlocking,low-profile)concrete roof tiles.
Nail Holes
•
Ih:I/z.,
Estate"S"
a
Gy
Hacienda
Exterior Research and Design,I.I.C. Evaluation Report E3933011.11-1-R3
Certlflcate ofAuthorkation#9503 FL7804-119
Revision 3:04/18/2016
Page 4 of 9
I
i
I
` TRINITY j ERD
4.4 GALENA SPANISH"S"and REGAL are TA5112,Type 2a(non-interlocking,high-profile)concrete roof tiles.
17"
10"
Galena Spanish"S"
J
Gyp
13 V4'•
Regal
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or other jurisdictions adopting FBC HVHZ
requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC Section 1516 or current Approved Roofing
Materials Directory for fire rating of this product.
5.4 Reference is made to FBC Section 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112,Appendix`A'. Such testing shall be submitted to Trinity I ERD for review.
5.6 Minimum underlayment shall comply with the RAS 118,RAS 119 or RAS 120,as applicable. Underlayment
products shall hold Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in
HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R3
Certiftale opauthori:atton N9503 FL7804-R9
Revision 3:04/18/2016
Page 5 of 9
I
I
' I z
TRINITY I ERD
6. INSTALLATION:
I
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120,as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment-Based System' in
accordance with RAS 127-11 using the data outlined herein.
TABLE3i ODYNAMICI1ntfLTIPLIERS
Tile Batten Application Direct-Deck Application
Bermuda Flat 0.189 0.205
Plantation Fla 0.267 onh
Horizon Fiat 0.305 0.330
Bella High"S" 0.349 0.378
Estate"S" 0.267 0.289
Hacienda 0.267 0.289
Galena Spanish"S" N/A 0.235
Regal 0.287 0.311
3
TABLE2 RESTORING.MOMEN'f=DUETdGRAVIiY �Illa{FTLBF) s v
_,.:�_E..s ._v..,» .._.._ ..-_3.... ,. .._;a..K .._
Roof Slope(0)
Tile 2:12<0<3:12 3:12<0<4:12 4:12<0<5:12 5:12<0<6:12 6:12<0<7:12 0>7:12
Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
Bermuda Flat 5.22 6A3 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83
antation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 6.44 7.32 6.26 7.04
Horizon 7.60 8.32 7.52 8.24 7A1 8.12 7.26 7.95 7.09 7.76 6.89 7.55
Bella High"S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13
Estate"S" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14
Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22
Galena Spanish"S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57
Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.61
Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R3
Certftute of Authod:atlon#9503 - FL7804-119
Revision 3:04/18/2016
Page 6 of 9
I
I
I
I
TRINITY i ERD
� �3aBt�3A �;Trac�fnn�t�t�slsr�ntca<°�xPR�ss�oas�►aulonn�nn' mF°(Fs�.e�)
u,. `lFltlfAOILE ',)1IMCtAtlttllA7 iACuYSTEMS .: _
Fastener Direct Deck Direct-Deck
(min.i5/32" (min.19/32'
Tile Type # Sae Shank Clip plywood) plywood) Battens
Nail One(1) 10d Smooth or Screw N/A 7.3 9.8 4.9
Nail Two(2) 10d Smooth or Screw N/A 14.0 18.8 7.4
Nail One(1) 10d Smooth or Screw Eave 19.0 19.0 22.1
Nail One(1) 10d Smooth or Screw Field 24.3 24.3 24.2
Bermuda Flat, Nail Two(2) 10d Smooth or Screw Eave 31.9 31.9 32.2
n tation t or Nail Two(2) 10d Smooth or Screw Field 35.5 35.5 34.8
Honzon Nail Two(2) 10d Ring N/A 30.9 38.1 17.2
Nail' Two(2)' 1Od' Ring' N/A 50.3' 65.5' 48.3'
Screw One(1) #8 N/A N/A 30.8 30.8 18.2
Screw Two 2) N/A N/A 51.7 .7 24.4
Installation with a 4 inc the headlap and fasteners located min.2Y inch from head of tile.
TABt>31 �2 #1TiaCfiMEt�iTESISraNCXPRESSIAS`1�Mt)fliF[�T MF(fi'LAF�
Size(inch) Weight(g)
To To
Tile Application Adhesive Substrate To Tile Substrate To Tile Mf(ft-lbf)
TILE BOND"' 1 x 6 1 x 6 -11 -11 40.6
Inter-
Touch'n Seal'StormBond 1.25 x 30 1.25 x 8 -8.3 -10.2 73.2
Bermuda Flat, Dependent ICP Adhesives Polyset RTA-1; "5"long -4.5" -9 -5 51.8
Plantation Flat or cross-bond oblong across head
Horizon ICP Adhesives Polyset AH-160 4 x 4 2 x 4 -16 -8 42.8
2 x 7 N/A "30 N/A 50.9
Independent ICP Adhesives Polyset AH-160 2 x 30 N/A -45 N/A 91.9
ABLE36-� Si. PE, XPAE55ED 51�(lt1�MENT�MF Ff LBF. '
x LOW PtttF1EE,(�LES�NIE�HpNttJI11YAaCl3EdYSTENI$ _
_
Fastener Direct-Deck Direct-Deck
(min.15/32" (min.39/32"
Tile Type # Sae Shank Clip plywood) plywood) Battens
Nail One(1)' 10d Smooth or Screw N/A 8.8' 11.8' 4.1'
Nail Two(2) 10d Smooth or Screw N/A 16.4 219 7.1
Nail One(1)' 30d Smooth or Screw Eave 19.0' 19.0' 22.1'
Nall One(1)' 10d Smooth or Screw Field 24.3' 24.3' 24.2'
Nail Two(2) 10d Smooth or5crew Eave 31.9 31.9 32.2
Nail Two(2) 10d Smooth or Screw Field 35.5 35.5 34.8
Estate"5"or Hacienda Nail Two(2) 10d Ring N/A 27.8 37.4 28.8
Nail' Two(2)' 10d' Ring' N/A 43.0' 67.5' 50.9,
Screw One(1)' #8 N/A N/A 25.8' 25.8' 22.9'
Screw Two(2) #8 N/A N/A 47.1 47.1 49.1
'Installation with a 4-inch tile headlap and fasteners located min.2%-inch from head of tile.
'For one(1)fastener installations,utilize hole that is approximately 4Y..-inch from the interlocking edge.
Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R3
Cerdflcate of AuthoHzorlon#9503 FL7804-R9
Revision 3:04/18/2016
Page 7 of 9
i
i
I
i
I
I
I
I
I
yr\� I -w."
�TRINITY I ERD
F s 'fAi3lE3B ATiACLMEN1RE517A�GEf(PRESSED/�S�7UIDWlf�i 7F{f7-fBF t r-
,��"
Size(inch) Weight(g)
To To
Tile Application Adhesive Substrate I To Tile Substrate To Tile Mf(ft-lbf)
TILE BOND' 1 x 6 1 x 6 -11 -11 43.8
Touch'n Seal'"StormBond 1.25 x 10 0.75 x 30 -8.4 -5.1 41.8
Inter-
Dependent ICP Adhesives Polyset RTA-1; -S"long -4.5 across _6 -5 44.0
cross-bond oblong head
Estate"S"or Hacienda ICP Adhesives Polyset AH-160 4 x 4 2 x 4 -16 "8 49.9
ICP Adhesives Polyset AH-160 2 x 7 N/A -30 N/A 36.5
Independent 2 x 10 N/A "54 N/A 60A
Mortar Per RAS 120 and Product Approval of Mortar Mfgr 20.6
_ CE ExRRESSED 95 A�11IONfENT MF{F!�ft�}: i
� y � HIGH.Pitf3FlLEF'flLES„MECHA1,�iCALLYAI7ACNEDSYS'[EiViS .,�.„,,,�' _ # v A
Fastener Direct-Deck Direct-Deck
(min.15/32" (min.19/32"
Tile Type # Size Shank Clip plywood) plywood) Battens
Nail One(1) 10d Smooth or Screw N/A 5.1 6.8 2.8
Nail Two(2) lod Smooth or Screw N/A 6.9 9.2 7.3
Nail One(1) SOd Smooth or Screw Feld 23.1 23.1 19.0
Nail One(1) 1Od Smooth or Screw Eave 29.3 29.3 24.0
o Nail Two(2) 30d Smooth or Screw Field 27.6 27.6 38.6
Spanish"5"or
Bella High" ;Regal Galena Nail Two(2) 10d Smooth or Screw Eave 38.1 38.1 41.8
Nail Two(2) 10d Ring N/A 28.6 41.2 19A
Nail' Two(2)' 10d' Ring' N/A 1 33.11 48.1' 50.91
Screw One(1) #8 N/A N/A 20.7 20.7 18.1
Screw Two(2) #8 N/A N/A 43.2 43.2 29.8
1 installation with a 4-inch tile headlap and fasteners located min.2Y:-inch from head of tile.
yTABLi 3C2 A73ACF>~f�IEN?BfSLSTAN1E3tPRES$EdASAMDMENi 7ViF�FTi�F) L
__.. AR
Size iSirSf�Ms
Size(Inch) Weight(g)
To To
Tile Application Adhesive Substrate To Tile Substrate To Tile Mf(ft-lbf)
TILE BOND' 1 x 6 Ix 10 `11 -22 48.1
Touch'n Seal'"StormBond 1.25 x 10 0.75 x 8 -8.4 `3.9 51.6
Inter-
Dependent ICP Adhesives Polyset RTA-1; two(2)"6" -10"across _12 each -15 36.2
Bella High"S",Galena cross-bond long oblong head
Spanish"S"or Regal ICP Adhesives Polyset AH-160 4 x 4 2 x 4 -16 -8 30.1
2 x 7 N/A `30 N/A 485
Independent ICP Adhesives Polyset AH-160 2 x 10 N/A -63 N/A 93.5
Mortar Per RA5120 and Product Approval of Mortar Mfgr 24.5
Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R3
Certificate cf AuthoAcation#9503 FL7804-119
Revision 3:04/18/2016
Page 8 of 9
I
i
i
I
i
i
I
i
f
I
F)o
TRINITY I ERD
4
I
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo,as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
E N T E Ei� R R
Labeling:Bermuda Flat,Plantation Flat,Estate"S",Bella High"S",Galena Spanish"S"
and/or
H nson
Labeling:Horizon Flat,Hacienda,Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant Profiles
Okeechobee,FL Bermuda Flat,Plantation Fiat,Estate"S",Bella High"S",Galena Spanish"S"
Ft.Myers,FL Horizon Flat,Hacienda
Deerfield Beach,FL Horizon Flat,Hacienda,Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies,LLC.—QUA9110;(813)621-5777
-END OF EVALUATION REPORT—
Exterior Research and Design,U.C. Evaluation Report E39310.11M-1-R3
Certiflmte ofAuthorizatlon 09503 FL7804-R9