Energy Calculation Form & Manual J's
i FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method i i Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Ci�y,State,Zip: FT.PIERCE, FL, Permit Number: Owner: VA 4n% 0Q_,s Jurisdiction: Del sign Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. igle w construction or existing New(From Plans) 9. Wall Types(1432.0 sqft.) Insulation Area 2. family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1224.00 ft2 i b.Frame-Wood,Adjacent R=11.0 208.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. C umber of Bedrooms 3 d.N/A R= ft2 1 10.Ceiling Types (1753.0 sqft.) Insulation Area 5. isI this a worst case? Yes a.Under Attic(Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade(ft2) 1753 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(151.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 325 a� U-Factor: Sgl,U=0.54 111.36 ft2 SHGC: SHGC=0.25 b U-Factor: Sgl, U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency J SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00 c U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: A ea Weighted Average Overhang Depth: 2.850 ft. Aia.Electric Cap:40 gallons Weighted Average SHGC: 0.250 14.Hot water systems Es. Floor Types (1753.0 sqft.) Insulation Area EF:0.970 a Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b N/A R= ft2 None ci N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 53.74 PASS Total Baseline Loads: 53.87 1 hereby certify that the plans and specifications covered by Review of the plans and O�T%E STATE this l calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance o a�P with the Florida Energy Code. PREPAR Y: rxoak�' Before construction is completed c DATE: '� this building will be inspected for compliance with Section 653.908 * `I I hereby certify that this building, as designed, is in compliance Florida Statutes. with,the Florida Energy Code. G'OD WE OWNER(P�C�EN& BUILDING OFFICIAL: DATE: ` DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. is 11.0 C �� 7/6/2017 2:44 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: WYNNE THE WINDSOR Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low I BLOCKS Number Name Area Volume Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 11 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes M.BATH 61 488 No 0 1 Yes Yes Yes LAUDRY 36 288 No 0 1 No Yes Yes BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes li KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 0 HALL 25 200 No 0 1 No Yes Yes 1 FOYER 92 736 No 0 1 Yes Yes Yes �12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 ---- 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab-On-Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 ---- 0 1 0 5 Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 _--- 0 1 0 7/6/2017 2:44 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 i I FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ____ 0 1 0 I 7 Slab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 __-_ 0 1 0 8 Slab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 ____ 0 1 0 9 Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 _--- 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 _--- 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ___ 0 1 0 I ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1847 ft2 292 ft2 Light 0.6 No 0.9 No 0 18.4 I ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC i 1 Full attic Vented 150 1753 ft2 N N I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood I WALLS i Adjacent Space Cavity Width Height Sheathing Framing Solar Below R-1/able Et In Et In Amm _ soro 1 NE=>W Exterior Concrete Block-Ext IndMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 2 SW=>E Exterior Concrete Block-Ext IndMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 3 NW=>S Exterior Concrete Block-Ext InsMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 NE=>W Exterior Concrete Block-Ext InsMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 i I I i 7/6/2017 2:44 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 I FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ornt 10 Wall T=ele Et In Et In Area RA/aIlle Fraction AhSnr A rarie% 5 NE=>W Exterior Concrete Block-Ext InsuM.BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 6 NE=>W Exterior Concrete Block-Ext InfiffDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 7 SW=>E Exterior Concrete Block-Ext InQlNING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0 8 NW=>S Exterior Concrete Block-Ext InEdNING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 9 SW=>E Exterior Concrete Block-Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0 10 NE=>W Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 13 NE=>W Exterior Concrete Block-Ext InglEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 14 SW=>E Exterior Concrete Block-Ext InQEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 15 N=>SW Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.5 0 I DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2 I WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang Vj # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 I INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 i I 7/6/2017 2:44 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 I HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None I SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz I DUCTS ---Supply---- ----Return-- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ftZ Attic 95 ftZ Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Pro gramable Thermostat:Y Ceiling Fans: CoolingJan Feb [ ]Mar Apr Ma X Jun X Jul Au JXJ Se Oct Nov H Dec Heatin Jan Feb [X]Mar Apr f j MaY Jun 4 Jul �xj AuSep f Oct Nov Dec Ve�tin Jan Feb X Mar [X A r [ Ma [ Jun [ Jul Aug Se [X Oct H Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Coo ing(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Coo ing(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Hewing(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I I 7/6/2017 2:44 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 I FORM R405-2014 J TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City,State,Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design,Location: FL,Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. 1Ioors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. (Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. arrow Cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be airtight, IC rated, and sealed to the drywall. ,Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 7162017 2:45 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FO i RM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1224.00 ftz b.Frame-Wood,Adjacent R=11.0 208.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. N comber of Bedrooms 3 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a. Under Attic(Vented) R=30.0 1753.00 ftz 6. Conditioned floor area(ftz) 1753 b.N/A R= ftz 7. Windows- Description Area ° R= ft z a. U-Factor: Sgl, U=0.54 111.36 ftz 11.Ducts R ftz a.Sup:Attic, Ret:Attic,AH:Attic 6 325 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ftz SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ftz a. Electric EF:0.97 z C..N/A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �ZNESTgT Construction through the above energy saving features which will be installed (or exceeded) yy� _ Fo in this �ome before final inspection. Otherwise, a new EPL Display Card will be completed yk�',�''�� ='�',�.� 'P�n based on installed Code compliant features. Builder Signature: Date: O -Aq Address of New Home: City/FL Zip. * 9 �* �� � ^�J�+� w16'�v� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "*i abet required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/6/2017 2:45 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 I Project Summary Job:: -�- wrightsoft Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM. Project Inf• • For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: Design • • Weather Fort Pierce, FL, US Winter Design-Conditions. Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible.Cooling Equipment Load Sizing Structure 18467 Btuh Structure 17655 Btuh Ducts 6190 Btuh Ducts 9340 Btuh Central vent(0 cfm). 0 Btuh Central vent(0 cfm) 0 Btuh Humnone idification 0 Btuh Blower e): 0 Btuh. Piping 0 Btuh Equipment load 24657 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25645 Btuh . Method Simplified Latent Cooling.Equipment Load Sizing . Construction quality Average Fireplaces 0 Structure 2453 Btuh Ducts 2554 Btuh Central vent(0 cfm) 0. Btuh Heatingg . cooling: (none). . . Area(ftz) 1753 1753 Equipment'latent load 5007 Btuh Volume(ft3) 14741 14741 Air changes/.hour 0.38. 0.20 Equipment total load 30652 Btuh Equiv.AVF.(cfm) 93 49 Req. total capacity at 0.70.SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 470F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual air flow 1160 cfm Actual.air flow 1160. cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point 34 OF Backup: Input=7 kW, Output=23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th"i01� 'C�,0+.F��� - wrightsoit" Right-Suite®Universal 2017 17.0.14 RSU08101 2017=Apr-10 17:Paage 8 ...k Calcs\Dacuments\WYNNE-THE WINDSOR-REVISED.rup Calc=MJS Front Door faces: N I -r -wrightsoft° Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Bqposed wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 280.0. ft 5 Room area 1753.0 ftz 280.0 ftz Ty .Construction U-value Or HTM Area (ftz) . Load Area (ft-) Load number (Btuh/ftz-°F). (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Coot Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A46cs 0.143 ne _-4:00 ,2:55 488 448 1795 1141' 192 192 769 489 1Ac1om 1270 ne 35;56 70:43 7 0 247 488 0 0 0 U 1Ac1om'. 1270 ne 3556 70:43 16 0 581 1151 0'.". JO 0 0' 11 y✓ 13A-4ocs 0.143 se 4.00 42.55 64 41 65 105 0 0 O _ :0 I—D 11DO 0 390 se 10.92 11.31 23 23 248 257 0 0 0 0 W 13Aocs 0143 -sw 4A0 :2.55 437 396 1584 1007 56 -56 224 143 4A5.2om� 0 770':sw 21;56: 27,53 41 45 893 1140.:. 0 0 0 . ;.0 13A4ocs 0.143 nw 4.00 2.55 290 217 867 551 112 79 318 202 1A-c1om 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 . 4A5-2omd .0.770 nw 21.56 36.90 41 0, 880 1505 0 0 0 0 P, 12C-0sw 0 091 :. 255 1:28-• `:308 308: Z84 :.. 395 0 C 16A 30md 0.032 0.90 2.32 1763 1753 1571 4067 .280 280 251 650 F 22A tpl;i .. ' 0 989 27.69 ? 0:00 170 ,.: 153 4237 0':' .280:. . ' ;45 :'..'::1246 0 6 c)AED excursion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 Appliances/other 1000 0 0 Subtotal(lines 6 to 13) 18467 .17655 4779 3789 Less extemal load 0 0 0 0 Less transfer 0 0 Redistribution 0 0 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 34% 53% 6190 9340 34% 53% 1602 2005 Total room load 24657 26995 6380 5794 Air required(cfm) 1160 1160 3001 249 Calculations approved byACCA to meet all requirements of.Manual J 8th Ed. A wcightsoft- Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N Page 1 wrightsoft' Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS ,AOL.COM 1 Room name WIC M.BATH 2 Exposed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4. Room dimensions 7.0 x 6.0 ft 1.0 x. 61.0 ft 5 Room area 63.0 ft2 61.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh(ft2L-0F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Coal 6 A V. 13A4ocs "A'143 :.ne 400 2.56:• 0- 0 0 0 56 49 196 -125. 1A c10 n 1 270 'ne 3 . 70.43 0 0 Q 0' 70 247 488 1A c1om 1 270 .he 35:56 70.43. 0 0 . 0 0- 0 0 0 'a 1Ac1orii .. 1.270 ne 3556 45.24'. 0 0 0 ` 0 0.-. 11 V}! 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 --D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13AAomcs.. . 0143..sw 4.00 . 2:55 0 : . 0 0 0 0 0 0 :0 L=C 5-20 0:776 sw 21i56_ 27.53 0 0 0 0 0 0 0' 0 VI! 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0,770 -nw 21.56 _ 36.90 0 0 0 0 0 0 0 0 12C-0sw; 0. 0 -:0 0'..'.: 0 0 0. C 16A-30md 0.032 0.90 2.32 63 63 56 146 61 61 55 142 F. .. 22AApl>.i -.c. 0;9i39 •-: - 27.69 ',. 0.00.- .63 0 .0' :. . 0` . :61 .7'._ :194 0 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 j b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to.13) 56 141 817 764 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 34% 53% 19 751 34% 531/o 274 404 F1Total room load 75 216 1 1091 ' 1168 Air required(cfm) 4 9 511. 50 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .4C�P. wcightsoft RightS 2017-Apr-1017:19:28 uite®Universal 2017 17.0.14 RSU08101 Page 2 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N i -► -wrightsofr Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM- 1 Room name LAUDRY BEDROOM 2 2 E)iposed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4. Room dimensions 6.0 x 6.0 ft 15.0 x 120 ft 5 Room area 36.0 ft2 180.0 ft? Ty Construction U-value Or HTM Area (ft') Load Area (ftj Load number (Btuh/ft'°F) (BtuWft2) or .perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat. Cool 6 0 143 .ne `4.00 2:55 0 0 0: 0 96 80 319 263. 1A c1om. 1 270 'ne 35:56 .70.43 0 0 0 0 0 0 '.0 p 1A c1om 1 270 ne 35:56 70:43 0`. 0' 0. "0�. _ -16 0 S61 9151' 1A c1om 1 270 :.ne 35;56 : ::45:24 0 > 0 0. 0 0 0 11 T 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �D. 11130 0390. se 10.92. 11.31 0 0 0 0 0 0 0 0 V�! 13A-0ocs 0143::sw 4.00 2.55 -. 0 . . 0 b :. 0. 0 D 0 0 sw 21:56.: 27.53 0 0 . : 0. 0 0 0 0 U 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 II �G 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 2.95 1i28 0 p 0 p p. .. .;. .0 C 16A 30md 0.032 - 0.90 2.32 36 36 32 84 180 180 161 418 0989 .27 69 . . 0.00 L 36 . . 0 p.: 0: 180:. 12 332 p i 6 c)AED emursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Vines 6 to 13) 32 81 1609 1772 Less extemal load 0 0 0 0 Less transfer 0 0 Redistribution 6 14 0 0 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 53% 13 50 34% 53% 541 945 Total room load 2156 2730 51 145 Air required(cfm) 2 6 101 117 i Calculations approved bYACCA to meet all requirements of Manual J.8th Ed Aft, . w h eigts . Right-Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 G�A ...k CalcsXDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N Page 3 -r - wrgghtsoft°. Right-M)Worksheet Dat e` Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT PIERCE,FL 34946 Phone:772-466-6769 Fax 772-466-6796 Email:QUICKCALC5 AOL.COM 1 Room name DINING/GREAT ROOM KITCHEN 2 .=ad well 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool- 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft2 209.0 ft2: Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft'L'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter. (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat. Cool 6 13A-0acs< 0143 =ne 4,00 2-55 0 0 0 0 1Ac1om, 1270 rte 3556 7043 0 0 0 0:' 0 1Ac1om .1270 ne 3556 70:43 0 0 0 0 , 0 0 0 Q', 1Ac1om 1270 rie 3556 4524 0 0 0 0 0 0. 0 0 11 VN 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 I.-p_ 11130 0,390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A-46cs. 0143 sw 400 2;55 267 226 _ 903•.. 574 98 98 392 '249. 4A52om° >0.710 =sw" 21 56 27.53 41 , 22 893 1140;. 0 13A4ocs ' 0.143 nw 4.00 2.55 178 137 549 349 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 _nw 21.56 36.90 41 0 880 1505 0 0 0 0 P... 12C 0sw._ ,0.091 .: 2 55 " 1:28: 0. 0':. 0 0:'" 116 176. 295._.. 148' C . 16A-30md 0.032 - 0.90 Z32 588 588 527_ 1364 209 209 187 1485 1- Ft 22FMtpl .0989< 27.:69 ,,.,.0.00 588 50 1385 0'_. 209= 11 305, _ 'U A. 6 c)AED emursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a) Infiltration 1000 282 220 . 62 b) .Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 p Appliances/other 0 1000 Subtotal pines 6 to 1.3) 0136 6679 '1399 188D Less e#emal load p p .0 0 Less transfer 0 0 0 0 " Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 1 34% 53%1 2058 - 3541 340/o 53%1 4691 995 Total room load 8200 10234 1867 2875 Air required(cfm) 386 440 88 124 Calculations approved byACCA to meet all requirements of Manual.J 8th Ed. A- w t rilghtsc3 - M17-Apr-10 17:19:28 Right-Suite®Universal 2017 17.0.14 RSU08101 Page-4. k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N f - wrightsoft° Right-J®Worksheet Job: Enure House Date:. By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34646 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS a[AOL.COM 1 Room name BATH HALL 2 .E)cposed wall 5.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool. 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 . ft 5 Room area 50.0 ft, 25.0 ft' Ty - Construction LI-value Or HTM Area (ftz) Load Area (ft') Load number (Btuh/ftz'F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S. Heat Cool 6 13Aflocs 0143 .ne 4;00 2;55 ', 40 40:"-: :160 102 -0-- 0 0 0 1Ac1om 127.0 'he 3556 70.1 0 0 0 0 0 0 0 0. 1A c1om' 1 270 ne 35 56 70.43 0 0 0 0 0 0 0 0' 1A c1orn 1.270 '.rie 35 56 45:24 0 . 0 0 - 0' 0 11 V�/ 13A4ocs 0.143 se 4.00 Z55 0 0 0 0 0 0 0 0 L-D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A-0ois. . . ...0.148-sw 4.00 255 . 0 0 0. 0 0- 0 0 0 .; 4A5 tom 0:770':sw 21.56; 27.53 0 0 . 0 0 0 - 0' 0 ".:0 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 �--G 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 II-I --GGG 4A5-2omd. 0.770.nw-- 21.56 36.90 0 0 0 0. 0 0 0 0. P. 12C-0sw4 :0.091 2 55 1:28:: 0 0 0 0 0: €0 0 r 0. C 16A 30md 0.032 - 0.90 2.32 50 50 45 116 25 25 22 58 F r 22A tpl>.s. -0:989.:._. 27 69 .:.. 0:00 -50 '.: 5''. :'._138;.. 0 25- 0 : p `r 0 L , 6 c)AFD exursion -8 -2 Envelope loss/gain 343 210 22 r% 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 p Appliances/other 0 0 0 p Subtotal(lines 6 to 13) 433 235 22 56 Less e)demal load 0 0 0 0 Less transfer 0 0 Redistribution 6 14 0 0 14 Subtotal 439 249 -� -% 0 0 15 Duct loads 34% 53% 147 132 340 53% 0 0 Total room load 586 381 Air required(cfm) 28 16 .0 p i Calculations approved byACCA to meet all requirements of Manual J 8th Ed c "F�F- wrigi tsoft- 2017-Apr-10 17:19:28 CAA Right-Suite®Universal 2017 17.0.14 RSUD8101 Page 5 .k CalcslDocum ents\WYNNE-THE WINDSOR-REVISED.rup Cale=MJ8 Front Door faces: N - wrightsofta Right-M Worksheet Job: Entire House Date` By: QUICK CALCS, INC: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name FOYER BEDROOM 3 2 Exposed wall 9.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 . Room dimensions 1.0 x 92.0 ft ' 13.0. x. 1&0 ft 5 Room area 92.0 ftz 169.0 ftz- Ty Construction U-value Or HTM Area (ft-) Load Area (ft2) Load number (Btuhlftz--'F) (Btuh/ftz) or .perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat. Cool 6 13A4ocs '0143 _ne „400 255 :._ ' 0 0 O f 0% 104 88 351 223, 1A�1om- 1270 ne 3556 70.43 0 0 0 0: 0 0 0 0 1Ac1om 1270 ,ne 3556 70.43 0 0 0 0 <D .0 0 0, 1A clom`- 1.270 ne 35.56 4524 0. 0 0 0 16 i0 581 .739 11 W 13A-4ocs 0.143 se 4.00" 2.55 64 41 165 105 0 0 0 0 -p 11D0 0 390 se 10.92 11.31 _ 23 23 248. 257 0 0 0 0 % - 13A4tocs - 0143 sw 4.00. 2.55: 8_ 8. 32 20 - 8 - - S;. 32 20. 1 r: 4A5-20m-... 0.770�.:..sw 21 56. 27.53 - .0 0 - 0._ - 0 0 .0- - 0 -0. yJ 13A11ocs 0.143 nw 4.00 Z55 0 0 0 0 0 0 0 0 L_GG 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A572omd 0 770 nw, 21.56 36.90 0 0 0 0. 0 0 0 0 P a 12c-1 0 061`°:- 2 5$ -128:. 88 88 ". 224 113 -',104 104 265 433 C 16A-30md. 0.032 - 0.90 2.32 92 92 82 213 169 169 151 392 F 22A tpl> 0 989:c- 270 0:00 "92 9 . <. 249 O r 169 14 6 c)AED excursion -25 -52 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(Iines 6 to 13) 1163 730 2020 1527 Less external load 0 0 0 0 Less transfer 0 0 1 Redistribution 0 0 0 0 0 0 14 Subtotal 1 2020 1527 15 Duct loads 34% 53% 390 386 34% 53% 677 808 Total room load 156 1116 2697 2335 Air required(cfm) 73 48 127 100 Calculations approved byACCA to meet all requirements of.Manual.J 8th Ed. P. wrightsoft- 2017-Apr-1017:19:28 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 6 , k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup. Calc=MJ8. Front Door faces: N I 1 � , I + - wlrightlsoft� Duct System Summary Date: Entire House By. QUICK CALCS,INC. j 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCWOL.COM I For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available:static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/100ft Actual air flow 1160 .cfm 1160 cfm Total effective length(TEL) 183 ft SupplyBranch Detail Table Design Htg Clg Design Diam_ H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (In) (in) Matl. Ln(ft) Ln(ft) Trunk BATH h 586 28 16 0.372 4.0 Ox 0 VIFx ' 19.5 115.0 st1 BEDROOM 2 c 2730 101 117 0.384 7.0 Ox0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 OxO VIFx 26.8 115.0 st1 DINING/GREAT ROOM c 3411 129 147 0.292 7.0 Ox 0 VIFx' 36.5 135.0 st2 DINING/GREAT ROOM-B C 3411 129 147 0.371 7.0 Ox 0 VIFx 19.91 115.0 stl DINING/GREAT ROOM-C.C 3411 129 147 0.276 7.0 Ox 0 V1Fx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 0x0 VIFx 7.0. 95.0 KITCHEN C 2875 88 124 0.366 6.0 Ox 0 VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 ox0 VIFx 19.9 115.0 st1 M.BATH h 1091 51 50 0.282 6.0 Ox 0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273' 6.0 Ox 0 VIFx 48.4 135.0 st2 MASTER BEDROOM-A h 3190 150 124 0.284 6.0 Ox 0 VIFx 40.9 135.0 st2 WIC c 216 1 41. 9 0.292 4.0 Ox0 1 VIFx 1 36.0 1 135.0 st2 Supply TrunDetail . • - Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (In) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx I wri htsoft6 2017-Apr-1017:19:29 1 9 - Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 Axk ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Caic=MJ8 Front Door faces: N I Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk. rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx I i i' I I I wri htsofta 2017-Apr-1017:19.29 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ...k CalcsWocuments\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N i r