Certification for Design Load Compliance
Project Name:
Mr., Mrs Sepe
Project Address: Lot 876 ; V S
R-2, SF Vb
Permit#: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed,signed,and sealed by the design professional of record.
• Submit(2)copies for residential, (3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family) €E�
o Residential AdditionP .0-1 -
,
1
o Any accessory structure requiring a building permit) ''°
- ---- _ Ir
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 16 Supplements using ASCE 7-10
2. Structure Designed as(check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B C X D
4. Design Wind Velocity 164 mph X ASD LRFD End Zone Width: 5 ft
5. Mean Roof Height 12' ft Roof Pitch: 3 :12 Parapet: 0 ft
6. Components &Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan opening):
N/A N/A N/A 75.08 90.51 N/A
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony: N/A PSF
N/A N/A N/A N/A N/A
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
I
8. Were Shear Walls Consi ered For Struc ure? Yes X Not Applicable Explain Why Not:
re
Existing structu tullt under Standard Building Code, siding replacement only
9. Is A Continuous Load Path Provided? Yes Not Applicable Explain Why Not:
Existing structure built under—Sfandar-dBullding Code, siding replacement only
10. Design Soil Bearing Pressure: N/A _PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans &specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified;: O F Pto John M. Foster AR0008511
•• ��, F�70 `®� Print Name Cert#&Co. Cert Auth.
John M. Foster -Architect