Loading...
HomeMy WebLinkAboutIn-Place Density Test ReportUniversal Engineering S Sciences Company ��RNAT�ONP UES Project No: 3360.1800067.0000 Workorder No: 223048-3 Report Date: 01/26/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772.924.3580 In -Place Density Test Report Client: D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician: Sean Hayes 1430 Culver Drive, NE Date Tested: 01/25/2021 Palm Bay, FL 32907 Project: CMT CREEKSIDE Various Locations,Vero Beach, County, FL 32967 Area Tested: 3235 Trinity Cir, Lot 73 Material: Native Reference Datum: 0 = Top of Final Grade The tests below meet the 95 % minimum compaction requirement. Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Laboratory: ASTM D1557 Modified Proctor Maximum Optimum Field Dry Field Soil Pass Test Density Moisture Density Moisture Compaction or No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail 7 North Corner 0-1 ft 118.6 10.8 116.0 10.6 98 Pass 8 South Corner 0-1 ft 118.6 10.8 114.8 11.0 97 Pass 9 Center 0-1 ft 118.6 10.8 115.7 10.9 98 Pass Remarks: Permit2011.0191 Reviewed By GFA International, Inc Certificate of Authorization No. 4930 Digitally signed J o h n by John Kent Date: Ken t 2021.01.26 10:16:32-05'00' John Kent Senior Project Engineer STATE OF FLORIDA Professional Engineer No. 63218 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1