Loading...
HomeMy WebLinkAboutHOFFMAN SPECSY 20/22/24 kW INCLUDES: • True PowerT" Electrical Technology • Two-line multilingual digital LCD Evolution"" controller (Eng I ish/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor • Standard Wi-Fi° connectivity • System status & maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a structure.` 'Must be located away from doors, windows, and fresh airintakes and in accordance with local codes, hd ps. //assets, swri. org/library/Directory0flistedProducts/ Constructionlndustry/973_DoC 204_13204-01-0i Rev9.pdf FEATURES GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007038-1, G007039-13 G007038-3, G007 - . Aluminum - Bisque) - 20 kW 60 Hz G007042-2, G007043-2, G00704 - G007043-�Mmi m - Bisque) - 22 kW 60 Hz G007209-0, G007210-0 uminum - Bisque) - 24 kW 60 Hz us or LISTED Note: CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are EfL or UL certitied in the USA only. O INNOVATIVE ENGINE DESIGN &RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac Force engine engine lineup offers added peace of mind and reliability for when it's needed el& It provides optimized FAST RESPONSE to changing load conditions and MAXI - the most. The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine. Digital voltage regulation at ±1 %. O TRUE POWERTM ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network farm produce less than 5%Total Harmonic Distortion for utility quality power. This provides parts and service know-how for the entire unit, from the engine to the smali- aliows confident operation of sensitive electronic equipment and micro -chip based est electronic component. appliances, such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK° CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link WI-Fi allows users to monitor generator status from any - where in the world using a smartphoneI tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. O PWRVIEW'" TRANSFER SWITCH: The Generac PWRview Automatic Transfer Switch integrates the PWRview energy monitor to provide real-time energy con- ' sumption data that can help lower a homes electricity bill. Using a convenient mobile app, homeowners can access energy usage and alert information while under utility power or generator power. The PWRview energy monitor is a simple to use and low cost tool which helps save money over the life of the generator. Included with model G007210-0. i' 9 f t i i t � i � i � GENERAL® 20/22/24 kW Features and Benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smal ler, light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1 %prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. PWRview Transfer Switch (if applicable) • PWRview energy monitor • Ability to view real-time energy consumption data • PWRview mobile app Energy usage at -a -glance. Better understand the home's energy profile. Access daily energy intelligence and insights. Evolution'" Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65%dropout, 80%pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. i 7 1 1 1 GENERAC® 20/22/24 kW Features and Benefits unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. Installation System • 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity (VVi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. r , i GENERAL® 20/22/24 kW Specifications Generator Model G0070381 13007042-2 121007038�3 G00704IN G00720H G007039A 13007043-2 13007039�3 G00704N G007210-0 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Bated.maximum conttnaous power capacity O P} - — ` 20,000 Watts22 006=4Ya8s` 0 000 Walls 22 Q(t0 Watts`, 24 �l0 Watts system Nate: Fuel pipe must cos. For BTU content, i Two-line plain text i for lull load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7 in water celumn (0.87-1.74 kPa) for NG,10-12 in water co umn ts/hr x 2500 (LP) or fta/hr x 1000 (NG). for Megajoule content, multiply m3/hr x 93.15 (LPj or m3/hr x 37.26 (NG). LCD Simple user interface for ease of operation. Rutomatc.sta[ionutiliV.bilwe W6ekty Bi weekly orfvi lysetectableexerciser., Start with starter control, unit stays on. If utility fails, transfer to load takes place. AulomaUcYoltageAegulatiotwithOvetandUndefYoltageProtection _ ;_ ; _ �_ __LL—, Standard _ �; __� ___ _ Under Frequency/Overload/Stepper Overcurrent Protection _ —Standard _ _ a, dnr iin i nw nil PrecvuaJHinh Oil Temnerature Shutdown Standard Common external fault capability aranuaru __ "Sound levels are taken from the front of the generator Sound levels taken from oiher sides of the generator may 6e higher depending on installation parameters. Rahng definitions Standby:: Appliable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (AII ratings in accordance vdth &55514, IS03046 and DIN6271). 'Maximum Idlovolt amps and current are subject fo and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approbmately 3.5% for each 1,000 ft (304.8 m) above sea level; and also vriil decrease approximately 1%for each 10 °F (6 °C) above 60 °F (i6 °C). GENERAC® 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features Model G007039-1, G007039-3 (20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. _ T 0007043 2 G007043 3 (22 kW� _'No of poles=_ 2 • Up to eight additional large (240 VAC) loads can be managed when used in conjunction Current rating (amps) LL _ — 200 v with Smart Management Modules (SMMs), _Voltagara(ing (VAC)i20%240 1 _ • Electrically operated, mechanically -held contacts for fast, clean connections. Ulility voltage monitor (fixed)' • Rated for all classes of load,100% equipment rated, both inductive and resistive. Pick-up 80% -Dropout 65% • 2-pole, 250 VAC contactors.Retumtailkity Aiiproz 13ses • Service equipment rated, dual coil design. Exercises bi-weekly for 5 minutes Standard • Rated for both aluminum and copper conductors. ETLorM! � Standard Enclosure type NEMANL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Chreaki rpmteeted:_ w v _2201 vircwr_ • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM - #6 *Function of Evolution controller Dimensions Exercise can be set to weekly, bi-weekly, or monthly 200 Amps 120/240, is Open Transition Service Rated Height Width H1 H2 Wi W2 Depth in 26.8 30A 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 PWRview Automatic Transfer Switch Features • Integrated PWRview monitor provides real-time energy usage data through PWRview app. • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Heavy duty Generac Contactor is an ETL recognized device. Dimensions 200 Amps 120/240,19 Open Transition Service Rated Height Width H1 H2 Wi W2 Depth in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 Model 0007210.0 Current rating (amps) _ 200 VoOage ratiriq (VACS _ _v 4 y � _ 1201240 iff � _ : Utility voltage monitor (fixed)* Pick-up 80% Dropout 65% Exercises bi-weekly for 5 minutes* Standard EfL orllLiis[ed 5tannddard Enclosure type NEMA 3R 2Crzcuttbreakerproiected � - �200ff _ - _ Lug range - 250 MCM - #6 *Function of Evolution controller Exercise can be set to weekly, bi-weekly, or monthly GENERAC 20/22/24 kW Available Accessories Model UPC G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 G007209-0 696471071511 G007210-0 696471078220 'tzl Dimensions & UPCs LEFT SIDE VIEW FROM VIEW Dimensions shorm are appropmate. See insallaiion manual for e><act dimensions. DO NOT USETHESE DIMENSIONS FOR INSTALLATION PURPOSES. 6enerac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2020 Generac Power Systems, Inc. All dghls reserved. All specifications are subject to change without notice. Part No, A0000937814 Rev. 8 07/30/2020