Loading...
HomeMy WebLinkAbout01-19-2021 David Hoffman-Final01/28/2021 E-1 1 OF 3GENERATORADDITION RISERDIAGRAMNEW GENERATOR FOR:DAVID HOFFMAN1031 BRADLEY ST.FORT PIERCE, FL. 34982LOAD MANAGEMENT "LCM" LOAD SHED LOAD MANAGEMENT TECHNOLOGY ALLOWS THE LOAD CONTROL MODULE TO MONITOR GENERATOR PERFORMANCE AND ONLY SHED LOADS WHEN ABSOLUTELY NECESSARY BY MONITORING GENERATOR CURRENT AND FREQUENCY. BY ONLY SHEDDING THE NONESSENTIAL CIRCUITS, THE ESSENTIAL CIRCUITS ARE ALWAYS POWERED. LOADS ARE SHED THROUGH INTERRUPTION OF INDIVIDUAL CONTROL CIRCUITS (AHU/AC) AND POWER CIRCUITS (RANGE AND WATER HEATER). GENERAL NOTES: ·THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. ·THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 7TH EDITION (2020), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE NFPA 70 (2017). ·ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. ·THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 110.26. ·PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. ·ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. ·GROUNDING PER NEC ARTICLE 250. ·STANDBY SYSTEM INSTALLATION PER NEC ARTICLE 702, AND MANUFACTURER INSTALLATION INSTRUCTIONS. NTS 1 GENERATOR ADDITION RISER DIAGRAM DATEREVISIONMARKDATE: SHEET DATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 0001911SCOPE OF WORK: ·INSTALL 200AMP SE RATED ATS NEXT TO UTILITY METER CAN ON EXTERIOR WALL. ·RE-FEED INTERIOR PANEL FROM NEW ATS. SEPARATE NEUTRALS AND GROUNDS IN PANEL IF REQUIRED. ·INSTALL COLD WATER BOND FROM ATS TO NEAREST CU WATER PIPING. ·UTILIZE A PRE-FABRICATED GENERATOR PAD. ·PROVIDE AND INSTALL (1) 22kW GENERAC GENERATOR. ·PROVIDE AND INSTALL CONDUIT AND CONDUCTORS FROM ATS TO GENERATOR. ·PROVIDE (1) LOAD SHED DEVICE PER SIZING DATA THIS SHEET. ·NEW LP TANK TO BE PROVIDED AND INSTALLED BY FERRELLGAS UNDER A SEPARATE PERMIT. ·NO NEW BRANCH CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS SCOPE OF WORK. EXISTING 200 AMP METER CAN 120/240 1Ø NEW 200 AMP GENERAC SE RATED ATS 100AMP BREAKER EXISTING (2) 5/8" X 8' CU GROUND RODS EXISTING 200 AMP PANEL NEW GENERATOR: AIR COOLED GENERAC 22KW GRADE GENERAL NOTES: 1. 2. LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. DARK AND RED LINE WORK REPRESENT NEW EQUIPMENT, CONDUIT, AND WIRE. ATTICATTIC GRADE ELECTRICAL LEGEND: SURFACE MOUNT 120/240V, 1Ø, 3-WIRE PANELBOARD FLUSH MOUNT 120/240V, 1Ø, 3-WIRE PANELBOARD SURFACE MOUNT 277/480V, 3Ø, 4-WIRE PANELBOARD FLUSH MOUNT 277/480V, 3Ø, 4-WIRE PANELBOARD UTILITY METER CAN OR METER/MAIN COMBO UNIT GENERATOR AND GENERATOR PAD GAS STORAGE TANK SURFACE MOUNT AUTOMATIC TRANSFER SWITCH NON-FUSED DISCONNECT FUSED DISCONNECT 30AR NF 3R FRAME SIZE NEMA RATING NON FUSED 30AR 30AF 3R FRAME SIZE NEMA RATING FUSE SIZE CONDUIT AND WIRE SCHEDULE SYMBOL DESCRIPTION EXISTING 2"PVC UNDERGROUND SERVICE FEEDER EXISTING OVERHEAD SERVICE RISER, WEATHERHEAD, AND UTILITY FEEDERS EXISTING 1/2"PVC W/ (1) #4 BARE CU 2"PVC W/ (3) #4/0 THWN AL 2"PVC W/ (3) #4/0 THWN AL, (1) #6 THHN CU GROUND 1-1/4"PVC SLEEVE W/ GENERAC CABLE W/ (3) #3 THHN CU, (1) #8 THHN CU GROUND, (5) #14THHN CU 1-1/4"PVC W/ (3) #3 THHN CU, (1) #8 THHN CU GROUND 3/4"PVC W/ (7) #14 THHN CU 1/2"PVC W/ (1) #4 BARE CU A B C D E F G H I E D POINT OF NEW CONNECTION EXISTING WATER LINE F (EXISTING)B AC ALTERNATING CURRENT A/C AIR CONDITIONING AFG ABOVE FINISHED GRADE AL ALUMINUM (CONDUCTOR) AHU AIR HANDLING UNIT ATS AUTOMATIC TRANSFER SWITCH AMP AMPERE AFCI ARC FAULT CIRCUIT INTERRUPTER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE C CONDUIT CU COPPER (CONDUCTOR) COVB CITY OF VERO BEACH DC DIRECT CURRENT DISC DISCONNECT EXIST EXISTING FPL FLORIDA POWER & LIGHT G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER IRC INDIAN RIVER COUNTY KVA KILOVOLT AMPERE KW KILOWATT MC METAL CLAD CABLE MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANELBOARD MTS MANUAL TRANSFER SWITCH MSB MAIN SWITCHBOARD MLO MAIN LUGS ONLY NEC NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT NTS NOT TO SCALE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION NON-SE NON SERVICE ENTRANCE RATED PLCS PLACES (QUANTITY) PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT RMC RIGID METAL CONDUIT RTU ROOF TOP UNIT SE SERVICE ENTRANCE RATED TYP TYPICAL TEMP TEMPORARY TRANS, TX TRANSFORMER UG UNDERGROUND UL UNDERWRITERS LABORATORY UON UNLESS OTHERWISE NOTED V VOLT VA VOLT AMPERE W WATT XFMR TRANSFORMER ABBREVIATIONS: NATURAL GAS METER NOTE: NOT ALL CONDUIT AND WIRE SHOWN ON THIS SCHEDULE MAY PERTAIN TO THIS PROJECT. (SOME SYMBOLS SHOWN MAY NOT PERTAIN TO THIS PROJECT) INTERIOR EXTERIOR INTERIOR EXTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR FINISHED FLOOR CI GROUND ROD EXISTING PANEL IS BACK TO BACK FROM EXISTING METER/MAIN.F:\Generator Drawings\01-19-2021 David Hoffman\01-19-2021 David Hoffman.dwg, 1/28/2021 10:35:18 AM BRADLEY STREET CL MYRTLE DRIVECL10'-0" 3'-0" NEW GENERATOR AND PAD EXISTING UTILITY METER NEW ATS NEW 500 GAL. LP TANK (BY OTHERS) EXISTING PANEL COVERED PATIO WOOD DECK COVERED ENTRY CHAIN LINK FENCE (TYPICAL) PROPERTY LINE 100.00'PROPERTY LINE 39.28'PROPERTY LINE 92.06'PROPERTY LINE 124.91'PROPERTY LINE 117.00'SINGLE FAMILY RESIDENCE 1031 BRADLEY ST. FORT PIERCE, FL. 34982 DRIVEWAY WOOD SHED 01/28/2021 2 OF 3GENERATORSITE PLANDATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 00019111" = 10'-0" 1 GENERATOR SITE PLAN DATEREVISIONMARKDATE: SHEET N W S E E-2 0'2.5'5'10'20' SCALE: 1" = 10'-0"NEW GENERATOR FOR:DAVID HOFFMAN1031 BRADLEY ST.FORT PIERCE, FL. 34982F:\Generator Drawings\01-19-2021 David Hoffman\01-19-2021 David Hoffman.dwg, 1/28/2021 10:35:47 AM 01/28/2021 3 OF 3 DATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 0001911DATEREVISIONMARKDATE: SHEET E-3PRE-FABRICATEDGENERATORPAD DETAILNO SCALE 1 PRE-FABRICATED GENERATOR PAD DETAIL NEW GENERATOR FOR:DAVID HOFFMAN1031 BRADLEY ST.FORT PIERCE, FL. 34982F:\Generator Drawings\01-19-2021 David Hoffman\01-19-2021 David Hoffman.dwg, 1/28/2021 10:35:58 AM