Loading...
HomeMy WebLinkAboutEngineering Planning&Development Services Department �. File Copy t �-. Building&Code Regulations Division q�2300VirginiaAvenue,FortPierce,FL34982—(772)462-1553io#�2,toa-� Ce REVIEWED FORrtification for Design Load Compliance �®®E CQ�pLI��C� Project Name: SGD REPLACEMENT . LU CIE COUNTY Project Address; 11000&OCEAN DR,.4-C W B O C Q ql 1�// / Permit: Occupancy Type: B Construction Type: V INSTRUCTIONS FOR USE: •This certification must be completed,signed,and sealed by the design professional of record. i •Submit(2)copies for residential,(3)copies for commercial with all permit applications invohring the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. *Note:Form not required for interior renovations.provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contactthe#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED:(complete all that apply) 1.DESIGN CODE:Florida Building Code 2020 7th Edition with 20 ,Supplements using ASCE 7-16 2.Structure Designed-as(check one): X Enclosed _Partially Enclosed Open 3.Risk Category: 1 X II 111 IV Exposure Category: _B C X D 4.Des' n Wind Velocity 170 mph 132 ASD N/A LRFD End Zone Width: 5 ft S.Mean Roof Height: 30 ft Roof Pitch: N/A :12 Parapet: N/A ft 6.Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 151MRH,clearly label on all plan openings): Zone 1: 29'9 Zone 2, 29.9 Zone 3: 29.9 Zone 4: 51.9 Zone 5: 51.9 Garage: 49.2 -82.7 -122.3 -56.3 -69.5 -64.1 7.Design Loads:Floor: N/A PSF Roof/Dead: N/A PSF RooffLive: N/A Balcony:_ N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF/CONCENTRATED S.Were i Shear Walls Considered For Structure? X Yes_Not Applicable Explain Why Not: 9.Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10.Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: i I certdy that,to the best of my knowledge and belief,the attached plans&specifications have been designed to comply with;he applicable structural portions of the building codes currently adopted and enforced by St.Lucie Count>��h�also 5ertify at structural eleme ep1 on these plans provide adequate resistance to the design foKce;spec�ad YY >.y / ,�11b�9 I � .F � 1�71✓'��tF�3 l� i { r Frf Y Paul Welch P.E. 29945 / 5115 Print Name Cert#&Co.CertAuth. iLr, $w Paul Welch Inc. 21 Siynatuee, 6te;an; 1984 S.W.Biltmore St.Suite#114 Port St.Lucie,FL Company Name&Address SCCf UVform V#UAU`12 Revisiid'3/1S/11-�JS� d , k 1 . o ,r, Saint Lucie County Building Department Product Approval Submittal Affidavit Permit# Building Address:11000 S.OCEAN DR. Contractor:TBD Opening Schedule:Swing dobrs,Overhead Doors,Sliding Doors, Fixed Glass,Windows&Skylights Opening ID FL or NOA Product Model# Manufacturer Glass Attachment Method Type,Size,Spacing& Building Product # Description Embedment (DISTANCE FROM CORNER/ Design Design DISTANCE O.C.) Pressure Pressure SGD 20-0429.09 SGD SGD 770 PGT IMPACT 1/4"X 1 3/8"MIN.EMBD.TC'S @ ALL +51,,6/-56 +/-60 FACTORY HOLES Product Model# Manufacturer Attachment Method Type,Size, Building Product Spacing,Embedment&Stiffener etc. Design Design Pressure lPressure Hurricane Panels N/A I have reviewed the above product approval information and approve it. Name:Paul Welch P.E. Certification Number:29945 ALL GLAZED EXTERIOR OPENINGS SHALL BE IMPACT RESISTANT. lPAu4.yVE�CH INC. MECH-El -CIVIL ENG. 1984 BILTMORE ST-#114 PmlectName: SGDREPLACEMEIla ✓. � 1� ° , PORT SAINT LUCIE,FL 34984 rl �� PAUL WELCH P.E. ' FLA REQ NO.29945 I Project Address: ll000 s.taCElaiU DR.4-r-