Loading...
HomeMy WebLinkAboutBuilding PermitALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 05/22/2017 Permit Number: 4 CQi.! N33'yyt' `' Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMIT APPLICATION FOR: Gas piping PROPOSED IMPROVEMENT LOCATION: Address: 9619 Enclave Circle, Port St Lucie, FL Legal Description: Enclave at the reserve lot 16 (or 3449-2247) Property Tax ID #: 3322-800-0019-000-0 Site Plan Name: Mayrides Residence Project Name: Mayrides Residence Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WORK: Underground line to generator and connection. Lot No.16 Block No. CONSTRUCTION INFORMATION: Additional work to be nertormed under this permit — check all apply: In �HVAC Gas Tank ZGas Piping _ Shutters ❑ Windows/Doors Electric ❑ Plumbing 11 Sprinklers 11 Generator F]Roof Roof pitch Total Sq. Ft of Construction: Cost of Construction: $ 1,137.06 S Ft. of First Floor: Utilities: Sewer F]Septic Building Height: OWNER/LESSEE: CONTRACTOR: NameTom Mayrides Name: Jonathan Hurd Address:9619 Enclave Cir Company: Ferrellgas LP City: Port St Lucie State:FL Zip Code: 34986 Fax: Phone No. (772) 335-3838 Address: 3232 SE Dixie Hwy City: Stuart State: FL Zip Code: 34997 Fax: (772) 287-3456 Phone No. (772) 287-4330 E-Mail: bob@villadelta.com Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail: katrinabelanger@ferrellgas.com State or County License: 01237 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable Name: MORTGAGE COMPANY: _ Not Applicable Name: Address: Address: City: State: Zip: Phone: City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: BONDING COMPANY: _Not Applicable Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recordinl? vour Notice of Commencement. n A A /I t'/l I / /1N44 /// P4­114 s Signature of wner/Lessee/Contractor as Agent for Owner I Signature ofgontractor/License Holddr STATE OF FLORIDA A� n STATE OF FLORIDA A' COUNTY OF I" l►�FT� ICI COUNTY OF Ml}�TI1� The forgq.ng instrument was acknowledged before me this ;� day of MAN/ 20 (Tby (Name of person acknowledging ) ture of Notary Public-QState of Personally Known __X_ OR Produced Identification Type of Identification Produced Commission No. �9/ J (Seal) The forgoing instrument was acknowledged before me thisA;NJday of HkV 120 1_7 by ion( AVnl 4R6 (Name of person acknowledging ) IV &VA 4 "t&m" (Sig4ature of Notary Public tate of FI ida ) Personally Known OR Produced Identification Type of Identification Produced r Commission No. 4 G C9 I I (Seal) MELISSAS.V MELISSAS.V01 INY MY COMMISSION # 00 091751 •; • �* MY COMMISSION # GG 091751 Revised 07/ 15/2 EXwIft FV* 202tkd kn Omded ThhruEXPIu202 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER _ REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE Z INITIALS 10 BOARD OF COUNTY COMMISSIONERS TANK SIZE GAS PIPING SCHEMATIC [A2J [L4] L1J [1_3] fL5 L2] 1[L6J [Al] [A3] TANK SIZE: 520 GALS. APPLICANCE — TYPE/SIZE Al �'oAtiaMi A2 A3 A4 A5 A6 PIPING LENGTH & SIZE PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division [A4J [A6J [L81 [L12] L7] L11 [L10] [A5] 60, 000 BTU BTU L1 Q/S FT. 31v INCH DIA. L2 FT. 3 c INCH DIA. L3 FT. INCH DIA. L4 FT. INCH DIA. L5 FT. INCH DIA. L6 FT. INCH DIA. L7 FT. INCH DIA. L8 FT. INCH DIA. L9 FT. INCH DIA. L10 FT. INCH DIA. L11 FT. INCH DIA. L12 FT. INCH DIA. Revised 7/22/14 BTU BTU BTU BTU TH ZE PLANS AND ALL PROPOSED WCtiid ARE SUBJECT TO ANY COP.RCCTIONS `REQUIRED BY FIELD fN%PECTOFZS TI4RT MAY BE NECESSARY IN OAD2M TO CUIPLY WITH ALL APPLIC ME COOE3. (PIPE SIZE WAS TAKEN FROM THE 2014 FBC FUEL GAS CODE — TABLE 402 ( )) Website- www.stlucieco.aov 2300 Virginia Avenue - Fort Pierce, FL. 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578 7 /_' V 31. L14CIP 00 TY BUILDINQ DIVISION REVIEWED FOR COMPLIAN REVIEWED BY DATE Q < — — PLANS Aft PifRy1IT MUST BE KEPT ON &OB OR NO INSPECTION WILL BE MADE C el Tarantift"-' INDUSTRIES INC. LV4403TR 3TR * L 44 k Rego First Stage Regulators First Stage Regulators, High Pressure Domestic Provides accurate first stage regulation in two -stage bulk tank systems. Reduces tank pressure to an intermediate pressure of 5 to 10 PSIG. Also used to supply high pressure burners for applications like industrial furnaces or boilers. Domestic LP -gas installations, also incorporated in multiple cylinder installations. PART INLET NUMBER CONNECTION OUTLET CONNECTION ORIFICE SIZE FACTORY DELIVERED PRESSURE INTEGRAL ADJUSTMENT RANGE RELIEF VALVE INCLUDED VAPOR CAPACITY BTU/HR.PROPANE LV3403TR 1W F. NPT 1/2" F.NPT 1/4" 11 9-13 Yes 1,500,000 LV4403TR4 1/2" F. NPT 1/2" F. NPT 114" 10 5-10 Yes 21500,000* LV4403SR9 1/2"F. NPT 1/2" F. NPT 114" - - 5 1-5 yes '2,500,000* LV4403TR9 F. POL 112" F. NPT 1/4" 10 5-10 Yes 2,500,000* LV4403SR96 F. POL 3/4'',F. NPT 114" -5 1-5 Yes 2,500,700* LV4403TR96 F. POL 3/4" F. NPT 114" 10 5-10 Yes 2,500,000` LV3403TRV9 1/4" F. NPT 1/2" F. NPT 1I4" 10 Yes .. 1,500,000** niyllul rnan we ieywaiur setting ano oenvery pressure zu 1 rower tnan the setting. ' ` Vent at 9 o'clock. <.., Rego Law Pressure Second Stage Regulators Second Stage Regulators Low Pressure, Domestic .>. Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 11" WC. Ideal for medium commercial installations, multiple cylinder installations and normal domestic loads. Backmount Design Mounts directly to house line piping. Eliminates need for union joints and elbows and qLV4403B Lvs503B mounting brackets. Quick and easy to install. PART NUMBER INLET CONNECTION OUTLET CONNECTION ORIFICE SIZE FACTORY DELIVERED PRESSURE ADJUSTMENT RANGE VENT POSITION VAPOR CAPACITY BTU/HR. PROPANE LV440384 112" F. NPT 112" F. NPT #28 Drill 11" WC at 10 PSIG Inlet 9" to 13" WC Over Inlet 935,000 LV4403B46 112" F. NPT 3/4" F NPT 128 Drill 11" WC at 10 PSIG Inlet 9" to 13" WC Over Inlet 935,000 LV4403B46R* 112" F. NPT 3/4" F. NPT #28 Drill 11" WC at 10 PSIG Inlet 9" to 13" WC Over Inlet 935,000 LV44031366 3/4" F. NPT 3/4" F. NPT #28 Drill 11" WC at 10 PSIG Inlet 9" to 13" WC Over Inlet 935,000 LV4403866R* 3/4" F. NPT 3/4" F. NPT #28 Drill 11" WC at 10 PSIG Inlet 9" to 13" WC Over Inlet 935,000 LV5503134 1/2" F. NPT 3/4" F. NPT 1/4" 11" WC at 10 PSIG Inlet 9" to 13" WC Over Inlet 1,600,000 LV5503B6 3/4" F. NPT 3/4" F. NPT 114" 11" WC at 10 PSIG Inlet' '9" to 13" WC Over Inlet 1,600,000 LV5503138 3/4" F NPT 1" F. NPT 9/32 11" WC at 10 PSIG Inlet 9" to 13" WC Over Inlet 2,300,000 LV4403B66RA** 3/4" F. NPT 3/4" F. NPT '3/16" 11" WC at 10 PSIG Inlet '9" to 13" WC Over Inlet 1,000,000 LV4403666R- AB** 3/4" F. NPT 3/4" F. NPT 3/16" 11" WC at 10 PSIG Inlet 9" to 13" WC Over Inlet 1,000,000 LV340364 1/2" F. NPT 1/2" F. NPT 1/4" 11" WCat10PSIG Inlet - - uacKmount uesign -- 5iaemount design RegO Low Pressure Second Stage Tobacco Barn Regulator~ Especially developed for drying barns in the tobacco industry. The LV5503G4 regulator will supply a steady and constant flow of fuel to as many as 12 to 20 burners throughout the barn. LV5503G4 UL PART NUMBER INLET CONNECTION OUTLET CONNECTION ORIFICE SIZE FACTORY DELIVERED PRESSURE ADJUSTMENT RANGE VENT POSITION VAPOR CAPACITY BTU/ HR. PROPANE LV5503G4 1/2" F. NPT 3/4" F. NPT 1/4" 15" WC at 15 PSI Inlet 8"-18" WC Over Inlet 1,750,000 iviaxinium truw is uaseu un tD rate imet ano is - VVU delivery pressure. i 58-94 LIQUEFIED PETROLEUM GAS CODE Table 15.1(o) Polyethylene Plastic Pipe Sizing Between First -Stage and Second -Stage Regulators: Nominal Outside Diameter (IPS) Gas: Undiluted Propane Inlet Pressure: 10.0 psi Pressure Drop: 1.0 psi Specific Gravity: 1.52 Plastic Pipe �i in. s/s in. 1 in. 11/4 in. 1 % in. 2 in. Length SDR 9.33 SDR 11.0 SDR 11.00 SDR 10.00 SDR 11.00 SDR 11.00 (ft) (0.660) (0.860) (1.077) (1.328) (1.554) (1.943) 30 2143 4292 77744 13416 20260 36402 40 1835 3673 6628 11482 17340 31155 50 1626 3256 5874 10176 15368 27612 60 1473 2950 5322 9220 .13924 25019 70 1355 2714 4896 8483 12810 23017 80 1261 2525 4555 7891 11918 21413 90 1183 2369 4274 7404 11182 20091 100 1117 2238 4037 6994 10562 18978 125 990 1983 3578 6199 9361 16820 150 897 1797 3242 5616 8482 15240 175 826 1653 2983 5167 7803 14020 200 778 1539 2775 4807 7259 13043 225 721 1443 2603 4510 6811 12238 250 681 1363 2459 4260 6434 11560 275 646 1294 2336 4046 6111 10979 ' 300 617 1235 2228 3860 5830 10474 350 567 1136 2050 3551 5363 9636 400 528 1057 1907 3304 4989 8965 450 495 992 1789 3100 4681 8411 500 468 937 1690 2928 4422 7945 600 424 849 1531 2653 4007 7199 700 390 781 1409 2441 3686 6623 800 363 726 1311 2271 3429 6161 900 340 682 1230 2131 3217 5781 1000 322 644 1162 2012 3039 5461 1500 258 517 933 1616 2441 4385 2000 221 443 798 1383 2089 3753 IPS• Iron pipe size. SDR: Standard dimension ratio. Notes: (1) Capacities are in 1000 Btu/hr. (2) Dimensions in parentheses are inside diameter.