Loading...
HomeMy WebLinkAboutAPPROVED, Design PressuresProperty Information Owner:John Fox Address:205 Holly Avenue Port Saint Lucie, FL 34952 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:40 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 53 38 7 32.7 -43.4 2 End 53 38 7 32.7 -43.4 3 End 37 38 7 33.5 -44.8 4 End 37 38 7 33.5 -44.8 5 End 53 38 7 32.7 -43.4 6 End 53 38 7 32.7 -43.4 7 End 37 38 7 33.5 -44.8 8 End 26 26 7 33.5 -44.8 9 End 74 38 7 32.0 -41.9 10 End 53 50 7 32.2 -42.2 11 End 53 38 7 32.7 -43.4 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1