Loading...
HomeMy WebLinkAboutBuilding PermitALL APPLIC BLE 1 FO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: -I J L -11= • Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial PERMIT APPLICATION FOR: Fuel PROPOSED IMPROVEMENT LOCATION: / Address: /l/ fn/ i.✓r�t %rS �,.�.r�/i 1� 4( Legal Description: Em MAY 18 2017 PERiVIITT1N,G St. Lucie COUnly, FL Residential Property Tax ID #: 114 Z Z - '91y ^ O 01 7 - 02Q- 7 Lot No. Site Plan Name: Project Name: Setbacks Front Back: Right Side: Left Side: Block No. DETAILED DESCRIPTION OF WORK: I w,n %rAt �xs���'' k 4 ?c,SUi.► boo r!5p. / e.,Ov 4oA% ksf <d�► r�'�%+.'F'S%�/ie O� Azit-6e kc) dv, /p do-­4—�.L4 IrAe -rl>-t rW) �U c,,J r "� u �✓�./ i"..v../_� /zit h✓=t "�c �_ /�►Cv jt� ✓ ' �'f 4f C. �le—( �c CONSTRUCTION INFORMATION: Additional work to be nerformed under E1HVAC this permit - check ®Gas Piping all � apply: Shutters Windows/Doors Gas Tank 11 Electric ❑ Plumbing Sprinklers 1:1 Generator Roof Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ ,i..��. Utilities: Sewer _Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name 3C)A& sh%� ✓ Name: Larry Licastri Company: Amerigas Address: i' City: 1? �Df2. A Fe%.1 A0 -* State:.A4 17 Zip Code: ` '930?- Fax: Phone No. 9? 7 U-6 Address: 3301 Oleander Ave City: Fort Pierce State: FL Zip Code: 34982 Fax: 772-465-8448 Phone No. 772-633-0740 E-Mail: Fill in fee simple Title Holder on next page (if different from the Owner listed above) E-Mail: Bdan.Pearl@amedgas.com State or County License: 02707/28579 If value of construction is $2500 or more, a RECORDED Notice of Commencement is requires. �UPPL�MENTAL G131��TRUCTI�� L�E-�V �41lI1 IN�OI��At'T�QN�= _ � -- OESIGNER ENGINEER: Not Applicable MORTGAGE COMPANY: lot Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: ,_,Not Applicable BONDING COMPANY: .—Aot Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDViT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for Efomre 5nn ents to your property. A Notice of Commencement must be recorded and posted on the jobsite fir�ection. If you intend to obtain finan ' , c suit I lender or an attorney before ee rk r rprordine vour Notice of Commen ent Lessee STATE OPR COUNTY OF NO The forgoing instrument was acknowledged before me this IL day of AA Cks4 20_A by &"U (/1 a* (Name of perso cknowledgin ) (Signature of Notary Public- State of Florida ) Personally Known Y OR Produced Identification Type of Identification Produce AMBERL DIA7 Commission No. :(3091POMMISSION a FF9 EXPIRES February 01, REVIEWS FRONT ZONING SUPERVISOR COUNTER REVIEW REVIEW DATE RECEIVED DATE COMPLETED STATE OF-FLORIDA COUNTY OF S 11_ Lucti The forgoing instrument was acknowledged before me this _�D day of 10 20S7 by caAri (Name of person knowledging 611 W C" (Signature of Notary Public- State o orida ) Personally Known Lwe of Identification Prodl MY COMMISSION 0 FF956 S February 01, 20 PLANS REVIEW I VEGETATION EVI WS REVIEW LE I MANGROVE • 0 BOARD OF + ("re I I PLANNING 8r DEVELOPMENT COUNTY SERVICES DEPARTMENT COMMISSIONERS Building and Code Regulation Division GAS PIPING SCHEMATIC [A2] [A4] [A6] [L4] [L8] [L12] TANK L1 L3 L5 L7 L9 L11 SIZE L7 from Pool L2] [L6] heater HP line [1_10] [Al] [A3] [A5] 12017 a P :JIITTI�JG Luce TANK SIZE: 250 GALS. C;or:nty, FL APPLICANCE - TYPE/SIZE Al Pool Heater (exsting) 400,000 BTU A2 Tank less water heater (new) 199,000 BTU A3 Fire Place (exsting) 38,000 BTU A4 BBQ (exsting) 45,000 BTU A5 Tank less water heater (new) 199,000 BTU A6 Stove (new) 48,0000 BTU PIPING LENGTH & SIZE L150 FT. 3/4 HP INCH DIA. L25 FT. 3/4 LP INCH DIA. L35 FT. 1/2 LP INCH DIA. L420 FT. 1/2 HP INCH DIA. L570 FT. 1/2 LP INCH DIA. L62 FT. 1/2 LP INCH DIA. L7100 FT. 3/4 HP INCH DIA. L83 FT. 1/2 LP INCH DIA. L945 FT. 1/2 HP INCH DIA. L103 FT. 3/4 LP INCH DIA. L1130 FT. 1/2 LP INCH DIA. L123 FT. 1/2 LP INCH DIA. Revised 7/22/14 (PIPE SIZE WAS TAKEN FROM THE 2014 FBC FUEL GAS CODE — TABLE 402 S - i.1 `I I v ST. LUCIE COUNTY BUILDING DIVISION REVIEWED ��//� FOR COMPLI��E REVIEWED BY ��1 DATE b l�� PLANS A1413 PERMIT MUST BE KEPT ON JOB OR NO INSPECTION NIL! BE MADE Website: www.stiucieco.gov 2300 Virginia Avenue - Fort Pierce, FL. 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578 Copyrigh! 2t)15 Na[ionel lira Prolection Association (NFPA). Licensed, by agreement, for individual use and download on March 3, 2010ANER1GAS for designated user BRIAN PEARL. No other reproduction or transmjsSK any form d without written permisson of NFPA. For inquires or to report unapoOzed �cl ficensing@*a.org. r Chapter 15 • Pipe and Tubing Sizing Tables MAY 1 8 2017 PEFi:,M TIWG Si. Lu--ic- CCuntY, FI- 2014 LP -Gas Code Handbook TABLE 15.1(0) Polyeth'viene Plastic Pipe Sung Between First -Stage and Second -Stage Regulators: Nominal Outside Diameter (1P$ Gas: Undiluted Propane Filet Pressure: 10.0 psi Pressure Drop: 1.0 psi Speriic Gravity: 1.52 Plastic Pipe r12 in. -X4 in. 1 in. P14 in. 1'/ in. 2 in. Length SDR 9.33 SDR 11.0 SDR 11pt1 SDR 10.00 OR 11.00 SDR 11.00 (ft) (0.660) (0.860) (1.M (1.328) (1.554) (1.943) 30 2143 4292 7744 13416 20260 36402 40 1835 3673 6628 11482 17340 31155 50 1626 3256 5874 10176 15368 27612 60 1473 2950 5322 9220 13924 25019 70 1355 2714 4896 8483 12810 23017 90 1261 2525 4555 7891 11919 21413 90 1183 2369 4274 7404 11182 20091 100 1117 2238 4037 6994 10562 18978 125 990 1983 3578 6199 9361 16820 150 897 1797 3242 5616 8482 15?40 175 826 1653 2983 5167 7803 14020 200 778 1539 2775 4807 7259 13043 225 721 1443 2603 4510 6811 12238 250 681 1363 2459 4260 6434 11560 275 646 1294 2336 4046 6111 10979 300 617 1235 2228 3960 5830 10474 350 567 1136 2050 3551 5363 9636 400 528 1057 1907 3.104 4989 8965 450 495 992 1789 3100 4681 8411 500 468 937 1690 2928 4422 7945 600 424 849 1531 2653 4007 7199 700 390 781 1409 2441 3686 6623 800 363 726 1311 2271 3429 6161 900 340 682 1230 2131 3217 5781 1000 322 644 1162 2012 3039 5461 1500 258 517 933 1616 2441 4385 2000 221 443 798 1383 2089 3753 1PS: Iron pipe size. SDR: Standard dimension ratio. Notes: (I) Capacities the in 1000 Btu/hr. (2) Dimensions in parentheses are inside diameter. f V Copyright 2014 National Fire Protection Association (NFPA). Licenj1d, by agreement, for individual use and download on December 4, 2014 to��11 ERIGAS PROPANE for designated user JESSICA BOOTH. No other reproduction or transmission in any O rmitted without written permission of NFPA. For inquires or to report uW.zed use, contact licensing@ryfpa.org. PIPE AND TUBING SIZING TABLES 58-91 Table 15.1(f) Pipe Sizing Between First -Stage and Table 15.1(g) Copper Tube Sizing Between Second -Stage Second -Stage Regulators: Outside Diameter Copper Tubing, Regulator and Appliance: Outside Diameter Copper Tubing, Type K Type K Gas: Undiluted Propane Inlet Pressure: 10.0 psi Pressure Drop: 1.0 psi Specific Gravity: 1.52 Tubing Length 3/a in. t/2 in. 5/8 in. 3/4 in. 7/8 in. (ft) 0.305 0.402 0.527 0.652 0.745 30 284 587 1193 2085 2959 40 243 502 1021 1785 2532 50 216 445 905 1582 2244 60 195 403 820 1433 2033 70 180 371 754 1319 1871 80 167 345 702 1227 1740 90 157 374 659 1151 1633 100 148 306 622 1087 1542 150 119 246 500 873 1239 200 102 210 428 747 1060 250 90 186 379 662 940 300 82 169 343 600 851 350 75 155 316 552 783 400 70 144 294 514 729 450 66 136 276 482 654 500 62 128 260 455 646 600 56 116 236 412 585 700 52 107 217 379 538 800 48 99 202 353 501 900 45 93 189 331 470 1000 43 88 179 313 444 1500 34 71 144 251 356 2000 29 60 123 215 305 Notes: (1) Capacities are in 1000 Btu/hr. (2) To convert to capacities at a gauge pressure of 5 psi setting with 10 percent (0.5 psi) pressure drop, multiply values by 0.606. To con- vert to capacities at a gauge pressure of 15 psi setting with 10 percent (1.5 psi) pressure drop, multiply values by 1.380. Gas: Undiluted Propane Inlet Pressure: 11 in. w.c. Pressure Drop: 0.5 in. Specific Gravity: 1.52 Tubing Length 3/6 in. 1/2 in. 3/a in. 3/4 in. 7/e in. (ft) 0.305 0.402 0.527 0.652 0.745 10 45 93 188 329 467 20 31 64 129 226 321 30 25 51 104 182 258 40 21 44 89 156 221 50 19 39 79 138 196 60 17 35 71 125 177 80 15 30 61 107 152 100 13 27 54 95 134 125 11 24 48 84 119 150 10 21 44 76 108 200 9 18 37 65 92 250 8 16 33 58 82 300 7 15 30 52 74 350 7 14 28 48 68 400 6 13 26 45 63 Note: Capacities are in 1000 Btu/hr. MAY ; 8 St. Lucie L �7' J' Fill, 2014 Edition 0