Loading...
HomeMy WebLinkAboutAPPROVED, Design PressuresProperty Information Owner:Kimberly Peterson Address:5710 Winter Garden Parkway Fort Pierce, FL 34951 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:30 ft. Mean Roof Height:20 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 37 50 20 35.0 -46.5 2 End 37 50 20 35.0 -46.5 3 End 37 50 20 35.0 -46.5 4 End 37 38 20 35.6 -47.6 5 End 37 50 20 35.0 -46.5 6 End 46 24 20 35.6 -47.6 7 End 37 50 20 35.0 -46.5 8 End 37 50 20 35.0 -46.5 9 End 37 50 20 35.0 -46.5 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1